Evangelos I. Sakellariou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Evangelos I. Sakellariou has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Petros J. Axaopoulos
Department of Mechanical Engineering, University of West Attica, Campus II, Thivon 250, 12 241 Aegaleo, Greece
5 shared publications - Kosmas A. Kavadias
Soft Energy & Environmental Protection Laboratory, Mechanical Engineering Department, University of West Attica, 250 Thivon & P.Ralli Str., 12241 Athens, Greece
3 shared publications Petros Axaopoulos
3 shared publications- Bill Vaneck Bot
Laboratory of Energy, Materials, Modelling and Methods, Higher National Polytechnic School, University of Douala, Douala P.O. Box 2701, Cameroon
2 shared publications - Ioannis E. Sarris
Department of Mechanical Engineering, University of West Attica, Athens, Greece
2 shared publications - Andrew John Wright
De Montfort University
1 shared publication
Latest Publications
- 5 December 2025
- Published by Elsevier in Solar Energy
- Vol. 304
Experimental performance of a PVT collector during nocturnal operation
- 5 December 2025
- Published by Elsevier in Solar Energy
- Vol. 304
Experimental performance of a PVT collector during nocturnal operation
- 8 June 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 75
Probabilistic economic evaluation of the most prevalent in Greek market space heating systems
- 8 June 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 75
Probabilistic economic evaluation of the most prevalent in Greek market space heating systems
- Open Access
First Law Comparison of a Forced-Circulation Solar Water Heating System with an Identical Thermosyphon
The main categories of solar water heating systems (SWHSs) are the thermosyphon and the forced circulation (FC). This paper presents an experiment carried out with the aim to compare the energy performance of the FC with a thermosyphon SHWS. Identical SWHSs were installed side by side at the University of West Attica in Athens, Greece. Domestic hot water load was applied to both systems via a microcontroller-based dispensing unit which mimics the demand profile. The trial period comprised the last two months of spring (April and May). For the first law assessment, two energy indicators were utilized: the solar fraction (SF) and the thermal efficiency of the system (ηth). On days with distinctive weather conditions, both systems obtained approximately equal SF and ηth values, without a specific preference between the ambient conditions and the type of SWHS. Regarding a four-day nonstop operation, the FC overperformed the thermosyphon system at both energy indicators. Namely, for the FC and the thermosyphon SWHS, the SF was calculated to be 0.62 and 0.48, and the ηth was 68.2% and 53.3%, respectively.
Open AccessFirst Law Comparison of a Forced-Circulation Solar Water Heating System with an Identical Thermosyphon
The main categories of solar water heating systems (SWHSs) are the thermosyphon and the forced circulation (FC). This paper presents an experiment carried out with the aim to compare the energy performance of the FC with a thermosyphon SHWS. Identical SWHSs were installed side by side at the University of West Attica in Athens, Greece. Domestic hot water load was applied to both systems via a microcontroller-based dispensing unit which mimics the demand profile. The trial period comprised the last two months of spring (April and May). For the first law assessment, two energy indicators were utilized: the solar fraction (SF) and the thermal efficiency of the system (ηth). On days with distinctive weather conditions, both systems obtained approximately equal SF and ηth values, without a specific preference between the ambient conditions and the type of SWHS. Regarding a four-day nonstop operation, the FC overperformed the thermosyphon system at both energy indicators. Namely, for the FC and the thermosyphon SWHS, the SF was calculated to be 0.62 and 0.48, and the ηth was 68.2% and 53.3%, respectively.
- Open Access
Energy Performance Evaluation of a Solar PVT Thermal Energy Storage System Based on Small Size Borefield
In this study, a PVT-based solar-assisted ground source heat pump (SAGSHP) system with a small size borefield as the long-term heat storage component was energetically evaluated. The mathematical model of the system was formulated in TRNSYS and three cities with distinctive climates were chosen: Athens (Greece); Melbourne (Australia); and Ottawa (Canada). The parametric analyses were carried out for 10 years by varying the number of the PVT collectors and the size of the earth energy bank (EEB). The evaluation of the systems was made via two energy indicators, and the heat flow across the EEB was analyzed. The under-consideration system was found capable of establishing self-sufficiency as regards the energy consumption (renewable power fraction RPF > 1) for all locations. Namely, for Athens, any system with more than four PVT collectors, and for Melbourne, any system with more than eight PVTs was found with an RPF higher than 1, regardless of the EEB size. For Ottawa, self-sufficiency can be achieved with PVT arrays larger than 12 collectors for small EEBs, and with eight collectors for larger EEBs. The storage capacity was found to be an important parameter for the energy performance of the system. In particular, it was determined that, as the storage capacity enlarges the RPF and the seasonal performance factor (SPF) of the system improves, mainly due to the reduction of the electricity consumed by the heat pump and the auxiliary heating. Moreover, a larger storage capacity facilitates solar heat production by enlarging the available heat storage volume and by maintaining the EEB at relatively low temperatures.
Open AccessEnergy Performance Evaluation of a Solar PVT Thermal Energy Storage System Based on Small Size Borefield
In this study, a PVT-based solar-assisted ground source heat pump (SAGSHP) system with a small size borefield as the long-term heat storage component was energetically evaluated. The mathematical model of the system was formulated in TRNSYS and three cities with distinctive climates were chosen: Athens (Greece); Melbourne (Australia); and Ottawa (Canada). The parametric analyses were carried out for 10 years by varying the number of the PVT collectors and the size of the earth energy bank (EEB). The evaluation of the systems was made via two energy indicators, and the heat flow across the EEB was analyzed. The under-consideration system was found capable of establishing self-sufficiency as regards the energy consumption (renewable power fraction RPF > 1) for all locations. Namely, for Athens, any system with more than four PVT collectors, and for Melbourne, any system with more than eight PVTs was found with an RPF higher than 1, regardless of the EEB size. For Ottawa, self-sufficiency can be achieved with PVT arrays larger than 12 collectors for small EEBs, and with eight collectors for larger EEBs. The storage capacity was found to be an important parameter for the energy performance of the system. In particular, it was determined that, as the storage capacity enlarges the RPF and the seasonal performance factor (SPF) of the system improves, mainly due to the reduction of the electricity consumed by the heat pump and the auxiliary heating. Moreover, a larger storage capacity facilitates solar heat production by enlarging the available heat storage volume and by maintaining the EEB at relatively low temperatures.
- Open Access
Improving the Electrical Efficiency of the PV Panel via Geothermal Heat Exchanger: Mathematical Model, Validation and Parametric Analysis
Silicon based photovoltaic modules (PV) are a wide spread technology and are used for small and large PV power stations. At the moment, the most efficient method which can be used to improve the annual electrical energy production of PVs is solar tracking systems. However, solar tracking systems increase substantially the initial cost of the investment and insert maintenance costs. During the last few decades, alternative improving methods have been investigated. These methods are based on the reduction of the PV cell temperature, which adversely affects the power production. In the present study, a system with water based photovoltaic-thermal (PVT) collector paired with geothermal heat exchanger (GHE) is compared on the electrical energy basis with a conventional PV system. As the first approach on the topic, the aim is to find out in which extent the PVT-GHE system improves the electrical energy generation by cooling down the PV cells and which parameters influence the most its energy performance. With this aim in mind, the model of the system with the PV, PVT, and GHE was formulated in TRNSYS and validated via experimental data. Meteorological data for Athens (Greece) were used and parametric analyses were conducted. The results showed that the PVT based system can increase the generated electricity from 0.61 to 5.5%. The flowrate, the size of the GHE and the number in-series connected PVTs are the parameters which influence the most the energy performance of the system.
Open AccessImproving the Electrical Efficiency of the PV Panel via Geothermal Heat Exchanger: Mathematical Model, Validation and Parametric Analysis
Silicon based photovoltaic modules (PV) are a wide spread technology and are used for small and large PV power stations. At the moment, the most efficient method which can be used to improve the annual electrical energy production of PVs is solar tracking systems. However, solar tracking systems increase substantially the initial cost of the investment and insert maintenance costs. During the last few decades, alternative improving methods have been investigated. These methods are based on the reduction of the PV cell temperature, which adversely affects the power production. In the present study, a system with water based photovoltaic-thermal (PVT) collector paired with geothermal heat exchanger (GHE) is compared on the electrical energy basis with a conventional PV system. As the first approach on the topic, the aim is to find out in which extent the PVT-GHE system improves the electrical energy generation by cooling down the PV cells and which parameters influence the most its energy performance. With this aim in mind, the model of the system with the PV, PVT, and GHE was formulated in TRNSYS and validated via experimental data. Meteorological data for Athens (Greece) were used and parametric analyses were conducted. The results showed that the PVT based system can increase the generated electricity from 0.61 to 5.5%. The flowrate, the size of the GHE and the number in-series connected PVTs are the parameters which influence the most the energy performance of the system.
- 1 November 2019
- Published by Elsevier in Solar Energy
- Vol. 193, 37-50
PVT based solar assisted ground source heat pump system: Modelling approach and sensitivity analyses
- 1 November 2019
- Published by Elsevier in Solar Energy
- Vol. 193, 37-50
PVT based solar assisted ground source heat pump system: Modelling approach and sensitivity analyses
- 1 November 2018
- Published by Elsevier in Solar Energy
- Vol. 174, 709-718
An experimentally validated, transient model for sheet and tube PVT collector
- 1 November 2018
- Published by Elsevier in Solar Energy
- Vol. 174, 709-718
An experimentally validated, transient model for sheet and tube PVT collector
- 1 October 2017
- Published by Elsevier in Solar Energy
- Vol. 155, 715-726
Simulation and experimental performance analysis of a modified PV panel to a PVT collector
- 1 October 2017
- Published by Elsevier in Solar Energy
- Vol. 155, 715-726
Simulation and experimental performance analysis of a modified PV panel to a PVT collector