Mark Rickman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mark Rickman has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Dominic Thewlis
University of Adelaide
7 shared publications - Lucian Bogdan Solomon
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
5 shared publications - Simon Thwaites
Centre for Orthopaedic and Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, Australia
3 shared publications - Arjun Sivakumar
Centre for Orthopaedic & Trauma Research, The University of Adelaide, South Australia, Australia
2 shared publications - John Matthew Abrahams
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
2 shared publications - Stuart Adam Callary
Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
2 shared publications
Latest Publications
- Open Access
- 23 May 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 170, 112169
Hip biomechanics in early recovery following fixation of intertrochanteric fractures: Results from a randomised controlled trial
- 23 May 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 170, 112169
Open AccessHip biomechanics in early recovery following fixation of intertrochanteric fractures: Results from a randomised controlled trial
- Open Access
- 2 November 2023
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 50 (2) , 619
Publisher Correction: The absence of reporting standards and a lack of objective, performance-based outcomes following intramedullary nailing of tibial shaft fractures: findings from a scoping review into 179 articles
- 2 November 2023
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 50 (2) , 619
Open AccessPublisher Correction: The absence of reporting standards and a lack of objective, performance-based outcomes following intramedullary nailing of tibial shaft fractures: findings from a scoping review into 179 articles
- Open Access
- 9 August 2023
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 50 (1) , 59-70
The absence of reporting standards and a lack of objective, performance-based outcomes following intramedullary nailing of tibial shaft fractures: findings from a scoping review into 179 articles
Purpose: This scoping review was conducted to summarise the outcome tools reported in the assessment of tibial shaft fractures treated with intramedullary (IM) nailing, with a key focus on knee pain and function, and performance-based outcomes. Methods: PubMed and Embase databases were searched on May 31, 2023. All study designs and populations were included, including ex vivo studies without fracture. Studies with only open or intra-articular fractures, or other fracture fixation, were excluded. Reported outcome tools and pertinent study characteristics were extracted and summarised. Results: Of 488 articles identified, 179 met the inclusion criteria. For in vivo studies (n = 152), there were 13,705 fractures; the IM nailing approach not described for 30% of these. There were 133 unique patient outcomes, with a binary assessment of knee pain (29% of studies) and Lysholm score (21%) most common. Only 10/152 (7%) in vivo studies included an objective, performance-based measure of knee function. Fracture union was most frequent (52%) of 81 different clinical outcomes. For ex vivo studies (n = 29), there were 408 tibias included, with nail insertion location most prevalent (66% of studies) of 34 reported outcomes. Conclusion: The heterogeneity of outcome tools reported limits comparison between studies and the most commonly reported patient outcomes may not be the most appropriate. Future studies should report the IM nailing approach and consider capturing both patient-reported and performance-based outcomes to help inform surgical decision making.
- 9 August 2023
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 50 (1) , 59-70
Open AccessThe absence of reporting standards and a lack of objective, performance-based outcomes following intramedullary nailing of tibial shaft fractures: findings from a scoping review into 179 articles
Purpose: This scoping review was conducted to summarise the outcome tools reported in the assessment of tibial shaft fractures treated with intramedullary (IM) nailing, with a key focus on knee pain and function, and performance-based outcomes. Methods: PubMed and Embase databases were searched on May 31, 2023. All study designs and populations were included, including ex vivo studies without fracture. Studies with only open or intra-articular fractures, or other fracture fixation, were excluded. Reported outcome tools and pertinent study characteristics were extracted and summarised. Results: Of 488 articles identified, 179 met the inclusion criteria. For in vivo studies (n = 152), there were 13,705 fractures; the IM nailing approach not described for 30% of these. There were 133 unique patient outcomes, with a binary assessment of knee pain (29% of studies) and Lysholm score (21%) most common. Only 10/152 (7%) in vivo studies included an objective, performance-based measure of knee function. Fracture union was most frequent (52%) of 81 different clinical outcomes. For ex vivo studies (n = 29), there were 408 tibias included, with nail insertion location most prevalent (66% of studies) of 34 reported outcomes. Conclusion: The heterogeneity of outcome tools reported limits comparison between studies and the most commonly reported patient outcomes may not be the most appropriate. Future studies should report the IM nailing approach and consider capturing both patient-reported and performance-based outcomes to help inform surgical decision making.
- Open Access
- 26 May 2022
- Published by Springer Nature in Pilot and Feasibility Studies
- Vol. 8 (1) , 1-13
Investigating and defining outcomes of suprapatellar versus infrapatellar intramedullary nailing of tibial shaft fractures: a protocol for a pilot randomised controlled trial
Background: Anterior knee pain is often reported following intramedullary nailing of tibial shaft fractures. The aetiology remains unclear, but the surgical approach may play an important role. To date, no biomechanically validated method exists to assess patient outcomes specific to anterior knee pain in this cohort. The central aims of this study are to (1) evaluate the feasibility of a full-scale randomised controlled trial (RCT) investigating the influence of surgical approach on intramedullary nailing of tibial shaft fractures (suprapatellar versus infrapatellar nailing), (2) explore differences in clinical outcomes between the approaches, and (3) explore the development of a biomechanically validated methodology for assessing post-operative anterior knee pain and knee function specific to intramedullary nailing of tibial shaft fractures. Methods: This pilot study will follow a prospective randomised controlled design at the Royal Adelaide Hospital and The Queen Elizabeth Hospital (South Australia). This study aims to recruit 60 patients between 18 and 60 years old who will be randomly assigned to either the suprapatellar or infrapatellar approach following a decision for intramedullary surgical fixation by the treating surgeon. All nails in this study will be Stryker T2 Alpha nails. Patients will undergo standard radiograph, magnetic resonance imaging, and clinical assessments in-line with their standard operative care, and complete a number of patient-reported and performance-based outcome measures. Performance-based outcome measures will be assessed utilising three-dimensional motion capture techniques. Follow-up time points are 3, 6, 12, and 18 months. Feasibility outcomes include ability to meet enrolment and retention metrics, compliance with all questionnaires and assessment procedures, and the occurrence of any adverse events. The primary clinical outcome is the incidence of anterior knee pain at 12 months after surgery. Discussion: This study will establish the feasibility and inform the design of a large-scale RCT. Evaluation of all clinical data and patient outcomes will lead to the development of a new tool for assessing patient outcomes in this cohort. Limitations of the study include an unpredictable enrolment rate and loss to follow-up, small sample size, and the unknown ability of three-dimensional motion analysis to pick up the effects of anterior knee pain after tibial nailing. Trial registration: This trial was prospectively registered on the 7 February 2020 on ANZCTR, ACTRN12620000109909.
- 26 May 2022
- Published by Springer Nature in Pilot and Feasibility Studies
- Vol. 8 (1) , 1-13
Open AccessInvestigating and defining outcomes of suprapatellar versus infrapatellar intramedullary nailing of tibial shaft fractures: a protocol for a pilot randomised controlled trial
Background: Anterior knee pain is often reported following intramedullary nailing of tibial shaft fractures. The aetiology remains unclear, but the surgical approach may play an important role. To date, no biomechanically validated method exists to assess patient outcomes specific to anterior knee pain in this cohort. The central aims of this study are to (1) evaluate the feasibility of a full-scale randomised controlled trial (RCT) investigating the influence of surgical approach on intramedullary nailing of tibial shaft fractures (suprapatellar versus infrapatellar nailing), (2) explore differences in clinical outcomes between the approaches, and (3) explore the development of a biomechanically validated methodology for assessing post-operative anterior knee pain and knee function specific to intramedullary nailing of tibial shaft fractures. Methods: This pilot study will follow a prospective randomised controlled design at the Royal Adelaide Hospital and The Queen Elizabeth Hospital (South Australia). This study aims to recruit 60 patients between 18 and 60 years old who will be randomly assigned to either the suprapatellar or infrapatellar approach following a decision for intramedullary surgical fixation by the treating surgeon. All nails in this study will be Stryker T2 Alpha nails. Patients will undergo standard radiograph, magnetic resonance imaging, and clinical assessments in-line with their standard operative care, and complete a number of patient-reported and performance-based outcome measures. Performance-based outcome measures will be assessed utilising three-dimensional motion capture techniques. Follow-up time points are 3, 6, 12, and 18 months. Feasibility outcomes include ability to meet enrolment and retention metrics, compliance with all questionnaires and assessment procedures, and the occurrence of any adverse events. The primary clinical outcome is the incidence of anterior knee pain at 12 months after surgery. Discussion: This study will establish the feasibility and inform the design of a large-scale RCT. Evaluation of all clinical data and patient outcomes will lead to the development of a new tool for assessing patient outcomes in this cohort. Limitations of the study include an unpredictable enrolment rate and loss to follow-up, small sample size, and the unknown ability of three-dimensional motion analysis to pick up the effects of anterior knee pain after tibial nailing. Trial registration: This trial was prospectively registered on the 7 February 2020 on ANZCTR, ACTRN12620000109909.
- Open Access
- 11 April 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Is unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe?
Rotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on the affected side for 6–8 weeks post operatively. We have been developing pelvic fixation standards to allow for unrestricted weight bearing immediately post operatively in type B rotationally unstable pelvic fractures. To assess for safety and efficacy of allowing unrestrictive weight bearing in this cohort of patients, we have clinically and radiologically monitored outcomes up to two years post operatively. Through retrospective review, two cohorts of patients with Tile Type B pelvic fractures were identified that were treated at the Royal Adelaide Hospital, South Australia. Patient demographics, injury classification, surgical fixation and weight bearing status post operatively was recorded. One cohort of patients was allowed to fully weight bear post operatively, whilst the other was treated with 6 weeks of restricted post op weight bearing. At clinical follow up, post-operative x-rays were assessed for loss of reduction, screw or plate breakage and reoperation. Between January 2018 and January 2021, 53 patients with rotationally unstable pelvic fractures that underwent surgical fixation were included in this study. One group of patents were allowed to immediately weight bear as tolerated (WBAT) post operatively (n = 28) and the other with restricted weightbearing (RWB) (n = 25). There was 1 re operation for failure of fixation in each group. Metalwork breakage was more common in the WBAT group than in the RWB group and this was seen only in APC fractures. This increase in metalwork failure was not associated with loss of reduction. With surgical fixation, Tile type B rotationally unstable pelvic fractures can be allowed immediate weight bearing post operatively. We found this to be safe and effective, employing surgical strategies to address both anterior and posterior injuries to allow immediate unrestricted weight bearing. Broken metalwork was more commonly seen in the WBAT group but this was not associated with loss of reduction or reoperation.
- 11 April 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Open AccessIs unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe?
Rotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on the affected side for 6–8 weeks post operatively. We have been developing pelvic fixation standards to allow for unrestricted weight bearing immediately post operatively in type B rotationally unstable pelvic fractures. To assess for safety and efficacy of allowing unrestrictive weight bearing in this cohort of patients, we have clinically and radiologically monitored outcomes up to two years post operatively. Through retrospective review, two cohorts of patients with Tile Type B pelvic fractures were identified that were treated at the Royal Adelaide Hospital, South Australia. Patient demographics, injury classification, surgical fixation and weight bearing status post operatively was recorded. One cohort of patients was allowed to fully weight bear post operatively, whilst the other was treated with 6 weeks of restricted post op weight bearing. At clinical follow up, post-operative x-rays were assessed for loss of reduction, screw or plate breakage and reoperation. Between January 2018 and January 2021, 53 patients with rotationally unstable pelvic fractures that underwent surgical fixation were included in this study. One group of patents were allowed to immediately weight bear as tolerated (WBAT) post operatively (n = 28) and the other with restricted weightbearing (RWB) (n = 25). There was 1 re operation for failure of fixation in each group. Metalwork breakage was more common in the WBAT group than in the RWB group and this was seen only in APC fractures. This increase in metalwork failure was not associated with loss of reduction. With surgical fixation, Tile type B rotationally unstable pelvic fractures can be allowed immediate weight bearing post operatively. We found this to be safe and effective, employing surgical strategies to address both anterior and posterior injuries to allow immediate unrestricted weight bearing. Broken metalwork was more commonly seen in the WBAT group but this was not associated with loss of reduction or reoperation.
- Open Access
- 24 October 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3411
Radiostereometric Analysis Allows Assessment of the Stability and Inducible Displacement of Pelvic Ring Disruptions during Healing: A Case Series
There is currently no accurate data on fracture displacement during the rehabilitation of pelvic ring injuries. This study investigated the use of radiostereometric analysis (RSA) in assessing the stability of C1 pelvic ring injuries stabilised with a posterior plate and an anterior external fixator. Six patients, instructed to weight-bear as tolerated after surgery, were reviewed at 2, 4, 6, 12, 26, 52 and 104 weeks. The external fixators were removed at 6 weeks. Outcomes, including the Iowa Pelvic Score (IPS), and complications were recorded. Fracture stability was assessed using measurements on plain radiographs and RSA. All patients progressed to full weight-bearing without support within 6 weeks. At 104 weeks, the IPS was excellent in four patients, good in one patient and fair in one patient. Plain radiographs showed that all fractures were well reduced, and no loss of reduction occurred over time. By contrast, RSA measurements identified displacement in all cases. The maximum three-dimensional (3D) displacement at any time point in each patient ranged from 2 to 10 mm. Two patients with the largest displacement over time had the lowest IPS. RSA also demonstrated displacements above the currently defined normal threshold through the ‘un-injured’ sacroiliac joint in the same two patients, suggesting a subtle C2 injury, missed at initial assessment. This study demonstrates the limitations of plain radiographs in assessing pelvic fracture stability and displacement during healing, and the potential of RSA to monitor more accurately the effects of stabilisation and weight-bearing on fracture stability.
- 24 October 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3411
Open AccessRadiostereometric Analysis Allows Assessment of the Stability and Inducible Displacement of Pelvic Ring Disruptions during Healing: A Case Series
There is currently no accurate data on fracture displacement during the rehabilitation of pelvic ring injuries. This study investigated the use of radiostereometric analysis (RSA) in assessing the stability of C1 pelvic ring injuries stabilised with a posterior plate and an anterior external fixator. Six patients, instructed to weight-bear as tolerated after surgery, were reviewed at 2, 4, 6, 12, 26, 52 and 104 weeks. The external fixators were removed at 6 weeks. Outcomes, including the Iowa Pelvic Score (IPS), and complications were recorded. Fracture stability was assessed using measurements on plain radiographs and RSA. All patients progressed to full weight-bearing without support within 6 weeks. At 104 weeks, the IPS was excellent in four patients, good in one patient and fair in one patient. Plain radiographs showed that all fractures were well reduced, and no loss of reduction occurred over time. By contrast, RSA measurements identified displacement in all cases. The maximum three-dimensional (3D) displacement at any time point in each patient ranged from 2 to 10 mm. Two patients with the largest displacement over time had the lowest IPS. RSA also demonstrated displacements above the currently defined normal threshold through the ‘un-injured’ sacroiliac joint in the same two patients, suggesting a subtle C2 injury, missed at initial assessment. This study demonstrates the limitations of plain radiographs in assessing pelvic fracture stability and displacement during healing, and the potential of RSA to monitor more accurately the effects of stabilisation and weight-bearing on fracture stability.
- Open Access
Proximal Femoral Nail Unlocked versus Locked (ProFNUL): a protocol for a multicentre, parallel-armed randomised controlled trial for the effect of femoral nail mode of lag screw locking and screw configuration in the treatment of intertrochanteric femur fractures
Introduction Intertrochanteric fractures are common fragility injuries in the elderly. Surgical fixation using intramedullary devices are one of the widely used management options. To date, evidence demonstrating the effects of lag screw configuration and the mode of lag screw locking in these devices is lacking. The purpose of this study is to investigate whether the lag screw configuration (single vs integrated dual interlocking screw) and the mode of lag screw locking (static vs dynamic) of a femoral nail device result in differences in clinical and functional outcomes. Methods and analysis A multicentre, pragmatic, single-blinded randomised controlled trial (RCT) with a three-arm parallel group design is proposed. Nine-hundred patients with intertrochanteric fractures (A1 and A2 AO/OTA) will be randomised to fracture treatment using a Gamma3 nail (Stryker; proximally dynamic) or a Trigen Intertan nail (Smith & Nephew) in a dynamic or static lag screw configuration. The primary outcome measure consists of radiological evidence of construct failure within 6 months following surgery, with failure being defined as breakage of the femoral nail or distal locking screw, a change in tip-apex distance of more than 10 mm or lag screw cut-out through the femoral head. Secondary outcomes include surgical data (operation time, fluoroscopy time), complications (surgical site infection, reoperation, patient death), return to mobility and home circumstances, functional independence, function and pain. Patients who are able to walk independently with or without a mobility aid and are able to answer simple questions and follow instructions will be asked to participate in three dimensional gait analysis at 6 weeks and 6 months to assess hip biomechanics from this cohort. Additional secondary measures of gait speed, hip range of motion, joint contact and muscle forces and gross activity monitoring patterns will be obtained in this subgroup. Ethics and dissemination The Central Adelaide Local Health Network Human Research Ethics Committee has approved the protocol for this RCT (HREC/17/RAH/433). The results will be disseminated via peer-reviewed publications and presentations at relevant conferences. Trial registration number ACTRN12618001431213.
Open AccessProximal Femoral Nail Unlocked versus Locked (ProFNUL): a protocol for a multicentre, parallel-armed randomised controlled trial for the effect of femoral nail mode of lag screw locking and screw configuration in the treatment of intertrochanteric femur fractures
Introduction Intertrochanteric fractures are common fragility injuries in the elderly. Surgical fixation using intramedullary devices are one of the widely used management options. To date, evidence demonstrating the effects of lag screw configuration and the mode of lag screw locking in these devices is lacking. The purpose of this study is to investigate whether the lag screw configuration (single vs integrated dual interlocking screw) and the mode of lag screw locking (static vs dynamic) of a femoral nail device result in differences in clinical and functional outcomes. Methods and analysis A multicentre, pragmatic, single-blinded randomised controlled trial (RCT) with a three-arm parallel group design is proposed. Nine-hundred patients with intertrochanteric fractures (A1 and A2 AO/OTA) will be randomised to fracture treatment using a Gamma3 nail (Stryker; proximally dynamic) or a Trigen Intertan nail (Smith & Nephew) in a dynamic or static lag screw configuration. The primary outcome measure consists of radiological evidence of construct failure within 6 months following surgery, with failure being defined as breakage of the femoral nail or distal locking screw, a change in tip-apex distance of more than 10 mm or lag screw cut-out through the femoral head. Secondary outcomes include surgical data (operation time, fluoroscopy time), complications (surgical site infection, reoperation, patient death), return to mobility and home circumstances, functional independence, function and pain. Patients who are able to walk independently with or without a mobility aid and are able to answer simple questions and follow instructions will be asked to participate in three dimensional gait analysis at 6 weeks and 6 months to assess hip biomechanics from this cohort. Additional secondary measures of gait speed, hip range of motion, joint contact and muscle forces and gross activity monitoring patterns will be obtained in this subgroup. Ethics and dissemination The Central Adelaide Local Health Network Human Research Ethics Committee has approved the protocol for this RCT (HREC/17/RAH/433). The results will be disseminated via peer-reviewed publications and presentations at relevant conferences. Trial registration number ACTRN12618001431213.
- Open Access
- 26 February 2019
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 20 (1) , 1-6
Tibia plateau fracture mapping and its influence on fracture fixation
Tibial plateau fracture classifications are based on anteroposterior radiographs. Precontoured locking plates are commonly used to treat such fractures. The aims of this study are to: (1) describe tibial plateau fracture anatomy in the axial plane and (2) assess whether current plating systems allow screws to be placed suitably. A graphical tibial plateau template was developed. One hundred twenty-five tibial plateau fractures (four bilateral) were reviewed (80 men, 41 women; average age 45.5 years, range 21–77.7 years). The axial computed tomography (CT) slice 0.3–0.5 mm below the medial articular surface was reviewed in all cases. Fracture lines were drawn on the template. Four lateral locking plates were placed against a cadaveric adult tibia. Based on the projected screw directions, suitable fracture patterns were identified. Fractures were considered “suitable” if the screws passed 90 ± 22° to the fracture line. Two hundred sixty-one different fracture lines were identified. One hundred thirty-four fractures involved the lateral plateau; 96 were suitable for lateral plating. Ninety fractures involved the medial plateau, 82 were treatable using the various plate positions on medial-posterior aspect of the medial plateau. Thirty-seven fractures were bicondylar; 20 were treatable with a posteromedial plate. Tibial plateau fractures follow consistent patterns, with most lateral and medial plateau fracture lines being in the sagittal plane, although there is greater variation medially. Positioning of modern locking plates will deal effectively with 72 % of all lateral plateau fractures and 91 % of medial plateau fractures. Level 3.
- 26 February 2019
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 20 (1) , 1-6
Open AccessTibia plateau fracture mapping and its influence on fracture fixation
Tibial plateau fracture classifications are based on anteroposterior radiographs. Precontoured locking plates are commonly used to treat such fractures. The aims of this study are to: (1) describe tibial plateau fracture anatomy in the axial plane and (2) assess whether current plating systems allow screws to be placed suitably. A graphical tibial plateau template was developed. One hundred twenty-five tibial plateau fractures (four bilateral) were reviewed (80 men, 41 women; average age 45.5 years, range 21–77.7 years). The axial computed tomography (CT) slice 0.3–0.5 mm below the medial articular surface was reviewed in all cases. Fracture lines were drawn on the template. Four lateral locking plates were placed against a cadaveric adult tibia. Based on the projected screw directions, suitable fracture patterns were identified. Fractures were considered “suitable” if the screws passed 90 ± 22° to the fracture line. Two hundred sixty-one different fracture lines were identified. One hundred thirty-four fractures involved the lateral plateau; 96 were suitable for lateral plating. Ninety fractures involved the medial plateau, 82 were treatable using the various plate positions on medial-posterior aspect of the medial plateau. Thirty-seven fractures were bicondylar; 20 were treatable with a posteromedial plate. Tibial plateau fractures follow consistent patterns, with most lateral and medial plateau fracture lines being in the sagittal plane, although there is greater variation medially. Positioning of modern locking plates will deal effectively with 72 % of all lateral plateau fractures and 91 % of medial plateau fractures. Level 3.
- Open Access
- 29 May 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-6
Outcomes and early revision rate after medial unicompartmental knee arthroplasty: prospective results from a non-designer single surgeon
This prospective study evaluates outcomes and reoperation rates for unicompartmental knee arthroplasty (UKA) from a single non-designer surgeon using relatively extended criteria of degenerative changes of grade 2 or above in either or both non-operated compartments. 187 consecutive medial mobile bearing UKA implants were included after history, clinical assessment and radiological evaluation. 91 patients had extended clinical outcomes. Post-operative assessment included functional scoring with the Oxford Knee Score (OKS) and radiographic review. Survivorship curves were constructed using the life-table method, with 95% confidence intervals calculated using Rothman’s equation. Separate endpoints were examined: revision for any reason and revision for confirmed loosening. The mean follow-up was 3.5 years. The pre-operative OKS improved from a mean of 21.2 to 38.9 (Mann-Whitney U Test, p = < 0.001). Twelve Patients required further operations including 9 revisions. No patients developed deep infection and no surviving implants were loose radiographically. Survivorship at 7 years with endpoints of re-operation, revision and aseptic loosening at surgery or radiographically was 88.4% (95% CI 79.6–93.7), 93.1% (95% CI 85.5–96.9) and 97.3% (95% CI 91.2–99.2) respectively. The presence of pre-operative mild contralateral tibiofemoral or any extent of patellofemoral joint degeneration was of no consequence. The indications for UKA are being expanded to include patients with greater deformity, more advanced disease in the patellofemoral joint and even certain features in the lateral compartment indicative of an anteromedial pattern of osteoarthritis (OA). However, much of the supporting literature remains available only from designer centres. This study represents a group of patients with what we believe to be wider indications, along with decisions to treat made on clinical grounds and radiographs alone. This study shows comparable clinical outcomes of UKA for extended indications from a high volume, high-usage non-designer unit.
- 29 May 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-6
Open AccessOutcomes and early revision rate after medial unicompartmental knee arthroplasty: prospective results from a non-designer single surgeon
This prospective study evaluates outcomes and reoperation rates for unicompartmental knee arthroplasty (UKA) from a single non-designer surgeon using relatively extended criteria of degenerative changes of grade 2 or above in either or both non-operated compartments. 187 consecutive medial mobile bearing UKA implants were included after history, clinical assessment and radiological evaluation. 91 patients had extended clinical outcomes. Post-operative assessment included functional scoring with the Oxford Knee Score (OKS) and radiographic review. Survivorship curves were constructed using the life-table method, with 95% confidence intervals calculated using Rothman’s equation. Separate endpoints were examined: revision for any reason and revision for confirmed loosening. The mean follow-up was 3.5 years. The pre-operative OKS improved from a mean of 21.2 to 38.9 (Mann-Whitney U Test, p = < 0.001). Twelve Patients required further operations including 9 revisions. No patients developed deep infection and no surviving implants were loose radiographically. Survivorship at 7 years with endpoints of re-operation, revision and aseptic loosening at surgery or radiographically was 88.4% (95% CI 79.6–93.7), 93.1% (95% CI 85.5–96.9) and 97.3% (95% CI 91.2–99.2) respectively. The presence of pre-operative mild contralateral tibiofemoral or any extent of patellofemoral joint degeneration was of no consequence. The indications for UKA are being expanded to include patients with greater deformity, more advanced disease in the patellofemoral joint and even certain features in the lateral compartment indicative of an anteromedial pattern of osteoarthritis (OA). However, much of the supporting literature remains available only from designer centres. This study represents a group of patients with what we believe to be wider indications, along with decisions to treat made on clinical grounds and radiographs alone. This study shows comparable clinical outcomes of UKA for extended indications from a high volume, high-usage non-designer unit.