Nimrod Blank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nimrod Blank has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Theodore Schreiber
Wayne State University, School of Medicine Detroit Medical Center, Detroit Heart Hospital Detroit Michigan
6 shared publicationsAmir Kaki
Wayne State University, School of Medicine Detroit Medical Center, Detroit Heart Hospital Detroit Michigan
4 shared publicationsSimon Dixon
Department of Cardiology, Beaumont Hospital, Royal Oak, Michigan
3 shared publicationsTamam Mohamad
Wayne State University, School of Medicine Detroit Medical Center, Detroit Heart Hospital Detroit Michigan
3 shared publicationsAkshay Khandelwal
Department of Cardiology, Henry Ford Hospital, Detroit, Michigan
2 shared publicationsCindy L. Grines
Zucker School of Medicine at Hofstra Northwell Health Northshore University Hospital Manhasset New York
2 shared publications
Latest Publications
- 19 November 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (6) , 969-977
Access and closure management of large bore femoral arterial access
Femoral and radial artery access continue to be the standard of care for percutaneous coronary interventions. Cardiac catheterization has progressed to encompass a wide range of diagnostic and interventional procedures including coronary, peripheral, endovascular, and structural heart disease interventions. Despite advanced technology to make these procedures safe, bleeding, and vascular complications continue to be a substantial source of morbidity, especially in patients undergoing large‐bore access procedures. New variations of percutaneous devices have reduced complications associated with these procedures. However, safe vascular access with effective hemostasis requires special techniques which have not been well described in the literature. Large‐bore femoral artery access is feasible, safe, and associated with low complication rates when a protocol is implemented. Wayne State University, Detroit Medical Center Heart Hospital is a tertiary care, high‐volume center for endovascular, structural heart and complex high risk indicated procedures with more 150 procedures involving mechanical circulatory support (MCS) devices per year. In this manuscript, we describe our approach to femoral artery large‐bore sheath insertion and management. Our protocol includes proper identification of the puncture site, device selection, insertion, assessment of limb perfusion while on prolong MCS support, and hemostasis techniques after sheath removal.
- 19 November 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (6) , 969-977
Access and closure management of large bore femoral arterial access
Femoral and radial artery access continue to be the standard of care for percutaneous coronary interventions. Cardiac catheterization has progressed to encompass a wide range of diagnostic and interventional procedures including coronary, peripheral, endovascular, and structural heart disease interventions. Despite advanced technology to make these procedures safe, bleeding, and vascular complications continue to be a substantial source of morbidity, especially in patients undergoing large‐bore access procedures. New variations of percutaneous devices have reduced complications associated with these procedures. However, safe vascular access with effective hemostasis requires special techniques which have not been well described in the literature. Large‐bore femoral artery access is feasible, safe, and associated with low complication rates when a protocol is implemented. Wayne State University, Detroit Medical Center Heart Hospital is a tertiary care, high‐volume center for endovascular, structural heart and complex high risk indicated procedures with more 150 procedures involving mechanical circulatory support (MCS) devices per year. In this manuscript, we describe our approach to femoral artery large‐bore sheath insertion and management. Our protocol includes proper identification of the puncture site, device selection, insertion, assessment of limb perfusion while on prolong MCS support, and hemostasis techniques after sheath removal.
- 7 March 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (4) , 518-524
Mechanical circulatory support for acute right ventricular failure in the setting of pulmonary embolism
Background: Right ventricular (RV) failure due to pulmonary embolism (PE) increases morbidity and mortality and contributes to prolonged hospital length of stay and higher costs of care. RV mechanical circulatory support (MCS) including Impella RP devices have been increasingly used in hemodynamically compromised PE patients who are refractory to intravascular volume expansion and inotropic therapy. However, effectiveness and safety of Impella RP, in hemodynamically unstable PE patients is unknown.Methods: We included consecutive patients who presented to Detroit Medical Center between November 3, 2015 and October 2, 2017 with acute PE and had evidence of hemodynamic compromise indicating Impella RP.Results: Total of five cases were identified. All patients met the shock definition due to massive or submassive PE and therefore received Impella RP on admission. Cardiac index was improved from mean of 1.69/min/m2, (0.88‐2.15 L/min/m2), to 2.5 L/min/m2 (range 1.88‐3.4), after 24 h of treatment. Similarly, mean heart rate reduced to 92 beats per minute (79‐105), and mean systolic blood pressure increased to 140 mmHg (115‐179). No significant changes were found in renal function, hemoglobin and platelets level during device use. One patient experienced hemoglobin drop from 13.7 to 7.3 g/dL but did not require blood transfusion. All patients survived to discharge.Conclusion: In patients with PE and RV shock, Impella RP device resulted in immediate hemodynamic benefit with reversal of shock and favorable survival to discharge.
- 7 March 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (4) , 518-524
Mechanical circulatory support for acute right ventricular failure in the setting of pulmonary embolism
Background: Right ventricular (RV) failure due to pulmonary embolism (PE) increases morbidity and mortality and contributes to prolonged hospital length of stay and higher costs of care. RV mechanical circulatory support (MCS) including Impella RP devices have been increasingly used in hemodynamically compromised PE patients who are refractory to intravascular volume expansion and inotropic therapy. However, effectiveness and safety of Impella RP, in hemodynamically unstable PE patients is unknown.Methods: We included consecutive patients who presented to Detroit Medical Center between November 3, 2015 and October 2, 2017 with acute PE and had evidence of hemodynamic compromise indicating Impella RP.Results: Total of five cases were identified. All patients met the shock definition due to massive or submassive PE and therefore received Impella RP on admission. Cardiac index was improved from mean of 1.69/min/m2, (0.88‐2.15 L/min/m2), to 2.5 L/min/m2 (range 1.88‐3.4), after 24 h of treatment. Similarly, mean heart rate reduced to 92 beats per minute (79‐105), and mean systolic blood pressure increased to 140 mmHg (115‐179). No significant changes were found in renal function, hemoglobin and platelets level during device use. One patient experienced hemoglobin drop from 13.7 to 7.3 g/dL but did not require blood transfusion. All patients survived to discharge.Conclusion: In patients with PE and RV shock, Impella RP device resulted in immediate hemodynamic benefit with reversal of shock and favorable survival to discharge.
- 1 January 2018
- Published by Elsevier in Interventional Cardiology Clinics
- Vol. 7 (1) , 119-128
Mechanical Circulatory Support for High-Risk Pulmonary Embolism
- 1 January 2018
- Published by Elsevier in Interventional Cardiology Clinics
- Vol. 7 (1) , 119-128
Mechanical Circulatory Support for High-Risk Pulmonary Embolism
- 20 December 2017
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 91 (3) , 454-461
Feasibility of early mechanical circulatory support in acute myocardial infarction complicated by cardiogenic shock: The Detroit cardiogenic shock initiative
Objective: The ‘Detroit Cardiogenic Shock Initiative’ is a single‐arm, multicenter study to assess the feasibility of early mechanical circulatory support (MCS) in patients who present with acute myocardial infarction complicated by cardiogenic shock (AMICS) who undergo percutaneous coronary intervention.Methods: Between July 2016 and February 2017, 4 metro Detroit sites participated in the study. The centers agreed to treat patients with AMICS using a mutually agreed‐upon protocol emphasizing invasive hemodynamic monitoring and rapid initiation of MCS. Inclusion and exclusion criteria mimicked those from the ‘SHOCK’ trial with an additional exclusion criteria being use of intra‐aortic balloon pump counter pulsation prior to MCS.Results: A total of 41 consecutive patients were included. Patients had an average age of 65 ± 14 years, 71% were male and 59% of patients were admitted to the hospital in cardiogenic shock. Prior to receiving MCS, 93% of patients were on vasopressors or inotropes, 15% of patients had a witnessed out of hospital cardiac arrest, 27% of patients had an in‐hospital cardiac arrest, and 17% were under active cardiopulmonary resuscitation while MCS was being implanted. In accordance to the protocol recommendation, 66% of patients had a MCS device inserted prior to PCI. Right heart catheterization and hemodynamic monitoring was performed in 83% of patients. Door to support times averaged 83 ± 58 minutes and 71% of patients were able to reduce the levels of inotropes and vasopressors within the first 24‐hours of their index procedure. Pre‐procedure cardiac power output (CPO) was 0.57 W and post‐procedure CPO was 0.95 W, a 67% increase (p < 0.001). Survival to explant for the entire cohort was 85% a significant improvement from institutional historical controls (85% vs 51% p < 0.001) and survival to discharge was 76%.Conclusion: Centers who adopted a regional shock protocol emphasizing the delivery of early MCS with invasive hemodynamic monitoring can achieve rapid door to support times and can improve survival in patients who present with AMICS. Larger national studies will be needed to further validate this pilot feasibility study.
- 20 December 2017
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 91 (3) , 454-461
Feasibility of early mechanical circulatory support in acute myocardial infarction complicated by cardiogenic shock: The Detroit cardiogenic shock initiative
Objective: The ‘Detroit Cardiogenic Shock Initiative’ is a single‐arm, multicenter study to assess the feasibility of early mechanical circulatory support (MCS) in patients who present with acute myocardial infarction complicated by cardiogenic shock (AMICS) who undergo percutaneous coronary intervention.Methods: Between July 2016 and February 2017, 4 metro Detroit sites participated in the study. The centers agreed to treat patients with AMICS using a mutually agreed‐upon protocol emphasizing invasive hemodynamic monitoring and rapid initiation of MCS. Inclusion and exclusion criteria mimicked those from the ‘SHOCK’ trial with an additional exclusion criteria being use of intra‐aortic balloon pump counter pulsation prior to MCS.Results: A total of 41 consecutive patients were included. Patients had an average age of 65 ± 14 years, 71% were male and 59% of patients were admitted to the hospital in cardiogenic shock. Prior to receiving MCS, 93% of patients were on vasopressors or inotropes, 15% of patients had a witnessed out of hospital cardiac arrest, 27% of patients had an in‐hospital cardiac arrest, and 17% were under active cardiopulmonary resuscitation while MCS was being implanted. In accordance to the protocol recommendation, 66% of patients had a MCS device inserted prior to PCI. Right heart catheterization and hemodynamic monitoring was performed in 83% of patients. Door to support times averaged 83 ± 58 minutes and 71% of patients were able to reduce the levels of inotropes and vasopressors within the first 24‐hours of their index procedure. Pre‐procedure cardiac power output (CPO) was 0.57 W and post‐procedure CPO was 0.95 W, a 67% increase (p < 0.001). Survival to explant for the entire cohort was 85% a significant improvement from institutional historical controls (85% vs 51% p < 0.001) and survival to discharge was 76%.Conclusion: Centers who adopted a regional shock protocol emphasizing the delivery of early MCS with invasive hemodynamic monitoring can achieve rapid door to support times and can improve survival in patients who present with AMICS. Larger national studies will be needed to further validate this pilot feasibility study.
- 1 August 2017
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 23 (8) , S67-S68
Despite Higher Morbity and Mortality Risk Women Had Similar Outcomes and Improvement in Heart Failure as Men in Complex PCI with Impella Hemodynamic Support
- 1 August 2017
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 23 (8) , S67-S68
Despite Higher Morbity and Mortality Risk Women Had Similar Outcomes and Improvement in Heart Failure as Men in Complex PCI with Impella Hemodynamic Support