Gianmario Schierano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gianmario Schierano has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
Giulio Preti
Department of Biomedical Sciences and Human Oncology, Section of Prosthetic Dentistry, School of Dentistry, University of Turin, Turin, Italy
9 shared publications- Stefano Carossa
Oral Surgery Unit, Dentistry Section, Department of Surgical Sciences, University of Turin, Dental School, Turin, Italy
9 shared publications - Francesco Bassi
Univ Torino, Dept Surg Sci, Turin, Italy
8 shared publications Carlo Manzella
Tutor, Surgical Science Department, Prosthodontic Section, Dental School C.I.R, University of Turin, Italy
7 shared publications- Cristina Bignardi
Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10129 Torino, Italy
6 shared publications - Domenico Baldi
Department of Surgical Sciences (DISC), Division of Prosthetic Dentistry, University of Genoa, Largo R. Benzi 10, 16132 Genoa, Italy
6 shared publications
Latest Publications
- Open Access
- 8 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 33
Efficiency and Risk Assessment of Dental Bridge Removal Tools on Implant Abutments
This study evaluated the efficiency and potential risks associated with three clinical tools for removing cement-retained implant-supported prostheses: Magnetic Mallet, sliding hammer, and Coronaflex. The tests consisted of: cementation of three-unit bridge models onto titanium abutments with different geometries using Zinc Oxide non-eugenol or Zinc Phosphate cement. Seven different geometries of three-unit bridges were tested; therefore, a total of 7 bridges × 2 luting agents × 3 tools were combined in a full factorial analysis. Five test replicates were performed for each combination, resulting in a total of 5 × 7 × 2 × 3 = 210 retrieval tests. The 70 tests regarding the Coronaflex were taken from a previously conducted experiment on the topic, using the same dental bridge models and the same experimental conditions. Efficiency was assessed by the percentage of successful removals and the maximum force recorded with a piezoelectric load cell. For temporary cementations, the sliding hammer achieved the highest retrieval rate, while the Magnetic Mallet demonstrated comparable efficiency with lower forces. Coronaflex showed lower success rates and higher forces than Magnetic Mallet. For permanent cementations, most bridges were not removable, and attempts with the sliding hammer occasionally resulted in abutment screw damage. Within the limitations of this study, the Magnetic Mallet appears to be an effective option for removing bridges cemented with temporary cement, potentially in combination with a sliding hammer for highly retentive geometries. Zinc phosphate cement should be avoided when retrievability is desired, except for abutments with very low retention capability.
- 8 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 33
Open AccessEfficiency and Risk Assessment of Dental Bridge Removal Tools on Implant Abutments
This study evaluated the efficiency and potential risks associated with three clinical tools for removing cement-retained implant-supported prostheses: Magnetic Mallet, sliding hammer, and Coronaflex. The tests consisted of: cementation of three-unit bridge models onto titanium abutments with different geometries using Zinc Oxide non-eugenol or Zinc Phosphate cement. Seven different geometries of three-unit bridges were tested; therefore, a total of 7 bridges × 2 luting agents × 3 tools were combined in a full factorial analysis. Five test replicates were performed for each combination, resulting in a total of 5 × 7 × 2 × 3 = 210 retrieval tests. The 70 tests regarding the Coronaflex were taken from a previously conducted experiment on the topic, using the same dental bridge models and the same experimental conditions. Efficiency was assessed by the percentage of successful removals and the maximum force recorded with a piezoelectric load cell. For temporary cementations, the sliding hammer achieved the highest retrieval rate, while the Magnetic Mallet demonstrated comparable efficiency with lower forces. Coronaflex showed lower success rates and higher forces than Magnetic Mallet. For permanent cementations, most bridges were not removable, and attempts with the sliding hammer occasionally resulted in abutment screw damage. Within the limitations of this study, the Magnetic Mallet appears to be an effective option for removing bridges cemented with temporary cement, potentially in combination with a sliding hammer for highly retentive geometries. Zinc phosphate cement should be avoided when retrievability is desired, except for abutments with very low retention capability.
- Open Access
- 1 January 2026
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 56
Influence of torque-curve dynamics on initial bone remodeling around dental implants: a multicenter prospective study
Stacchi C, et al. J Periodontal Implant Sci. 2026 ;56:e42. https://doi.org/10.5051/jpis.2601980099
- 1 January 2026
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 56
Open AccessInfluence of torque-curve dynamics on initial bone remodeling around dental implants: a multicenter prospective study
Stacchi C, et al. J Periodontal Implant Sci. 2026 ;56:e42. https://doi.org/10.5051/jpis.2601980099
- Open Access
- 7 August 2025
- Published by Wiley in Journal of Periodontal Research
- Vol. 61 (3) , 256-272
Prevalence and Risk Indicators of Peri‐Implant Diseases and Buccal Soft‐Tissue Dehiscence: A Cross‐Sectional Study From a University‐Based Cohort
Aim: To assess the prevalence of peri‐implant diseases and buccal peri‐implant soft‐tissue dehiscence (PISTD) and to identify the associated risk indicators. Methods: Patients previously rehabilitated with implant‐supported rehabilitations at the University of Turin Dental School were specifically recalled with a registry‐based approach for this cross‐sectional study. Data collection included medical and dental history, full‐mouth clinical examination, and periapical radiographs. Moderate/severe peri‐implantitis was diagnosed based on bone loss (direct criterion, when available) or bone level (indirect criterion) ≥ 2 mm and the presence of bleeding/suppuration. PISTD was defined as mucosal dehiscence on the buccal aspect of at least one implant site. Multilevel, multivariable logistic regression models were applied to identify factors associated with moderate/severe peri‐implantitis and buccal PISTD. Results: Of the 397 patients contacted, 146 were included (mean age 61.1 ± 14.5 years; current smokers 34.3%; stage III‐IV periodontitis 65.1%) with a total of 511 dental implants (mean function time: 13.3 years [2–31]). Implant survival rate was 96.5%. Moderate/severe peri‐implantitis was detected in 56.8% of patients and 34.7% of implants. Prevalence of buccal PISTD was 54.1% and 40.5%, respectively. Protective indicators for moderate/severe peri‐implantitis included supportive peri‐implant care > twice a year (OR = 0.16; 95% CI: 0.03–0.95), > 2 mm of keratinized tissue height (OR = 0.44; 95% CI: 0.21–0.95), and correct mesio‐distal implant positioning (OR = 0.54; 95% CI: 0.32–0.94). Risk indicators included stage III–IV periodontitis (OR = 2.82; 95% CI: 1.30–6.15), function time ≥ 10 years (OR = 3.02; 95% CI: 1.55–5.89), bisphosphonate use during follow‐up (OR = 5.96; 95% CI: 1.33–26.66), and presence of a cantilever (OR = 5.51; 95% CI: 1.56–19.38). For PISTD, protective indicators were mandibular location (OR = 0.45; 95% CI: 0.25–0.81), thick buccal soft‐tissue phenotype (OR = 0.18; 95% CI: 0.08–0.42), and > 2 mm of keratinized tissue height (OR = 0.05; 95% CI: 0.02–0.15). Risk indicators included peri‐implantitis (OR = 2.21; 95% CI: 1.25–3.91), use of intermediate abutments (OR = 4.92; 95% CI: 1.92–12.58), and proximity to adjacent implants (OR = 3.35; 95% CI: 1.50–7.48) or edentulous spaces (OR = 3.38; 95% CI: 1.51–7.54). Conclusion: In this long‐term, university‐based cohort, peri‐implant diseases and PISTD were highly prevalent. Multiple patient‐ and implant‐level factors emerged as significant risk or protective indicators. Despite the widespread occurrence of peri‐implant diseases, long‐term implant survival remained high, challenging current diagnostic thresholds and underscoring the need for refined, progression‐based definitions.
- 7 August 2025
- Published by Wiley in Journal of Periodontal Research
- Vol. 61 (3) , 256-272
Open AccessPrevalence and Risk Indicators of Peri‐Implant Diseases and Buccal Soft‐Tissue Dehiscence: A Cross‐Sectional Study From a University‐Based Cohort
Aim: To assess the prevalence of peri‐implant diseases and buccal peri‐implant soft‐tissue dehiscence (PISTD) and to identify the associated risk indicators. Methods: Patients previously rehabilitated with implant‐supported rehabilitations at the University of Turin Dental School were specifically recalled with a registry‐based approach for this cross‐sectional study. Data collection included medical and dental history, full‐mouth clinical examination, and periapical radiographs. Moderate/severe peri‐implantitis was diagnosed based on bone loss (direct criterion, when available) or bone level (indirect criterion) ≥ 2 mm and the presence of bleeding/suppuration. PISTD was defined as mucosal dehiscence on the buccal aspect of at least one implant site. Multilevel, multivariable logistic regression models were applied to identify factors associated with moderate/severe peri‐implantitis and buccal PISTD. Results: Of the 397 patients contacted, 146 were included (mean age 61.1 ± 14.5 years; current smokers 34.3%; stage III‐IV periodontitis 65.1%) with a total of 511 dental implants (mean function time: 13.3 years [2–31]). Implant survival rate was 96.5%. Moderate/severe peri‐implantitis was detected in 56.8% of patients and 34.7% of implants. Prevalence of buccal PISTD was 54.1% and 40.5%, respectively. Protective indicators for moderate/severe peri‐implantitis included supportive peri‐implant care > twice a year (OR = 0.16; 95% CI: 0.03–0.95), > 2 mm of keratinized tissue height (OR = 0.44; 95% CI: 0.21–0.95), and correct mesio‐distal implant positioning (OR = 0.54; 95% CI: 0.32–0.94). Risk indicators included stage III–IV periodontitis (OR = 2.82; 95% CI: 1.30–6.15), function time ≥ 10 years (OR = 3.02; 95% CI: 1.55–5.89), bisphosphonate use during follow‐up (OR = 5.96; 95% CI: 1.33–26.66), and presence of a cantilever (OR = 5.51; 95% CI: 1.56–19.38). For PISTD, protective indicators were mandibular location (OR = 0.45; 95% CI: 0.25–0.81), thick buccal soft‐tissue phenotype (OR = 0.18; 95% CI: 0.08–0.42), and > 2 mm of keratinized tissue height (OR = 0.05; 95% CI: 0.02–0.15). Risk indicators included peri‐implantitis (OR = 2.21; 95% CI: 1.25–3.91), use of intermediate abutments (OR = 4.92; 95% CI: 1.92–12.58), and proximity to adjacent implants (OR = 3.35; 95% CI: 1.50–7.48) or edentulous spaces (OR = 3.38; 95% CI: 1.51–7.54). Conclusion: In this long‐term, university‐based cohort, peri‐implant diseases and PISTD were highly prevalent. Multiple patient‐ and implant‐level factors emerged as significant risk or protective indicators. Despite the widespread occurrence of peri‐implant diseases, long‐term implant survival remained high, challenging current diagnostic thresholds and underscoring the need for refined, progression‐based definitions.
- Open Access
- 28 January 2025
- Published by Wiley in Journal of Prosthodontics
Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs
Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.Materials and Methods: Two implant sites were prepared in the tibia of four minipigs. At the time of implant placement (T0), bone cortex thickness and Implant Stability Quotient (ISQ) were assessed. A bone specimen was collected from the tibia and used as the baseline for biomolecular analyses. X‐ray was taken after implant insertion. After 14 days (T14), a computed tomography (CT) scan of the tibias was conducted, and ISQ values were reassessed. Histological and biomolecular analyses were performed on bone sections containing the implant.Results: ISQ significantly increased from T0 to T14, in the absence of any correlation between the cortical thickness and ISQ. In two animals, CT showed a slight trabecular bone thickening adjacent to the implants and disorganized radiodense spots; in the other two, no trabecular osseodensification was evident. Newly formed bone was about 48% of the tissue around implants. At T14, an increase in osteogenic factors and a decrease in inflammatory molecules were observed.Conclusion: This study enhances understanding of the biological and clinical responses at bone implant sites following piezoelectric surgery. It highlights the relationship between the rise in certain osteogenic factors and new bone formation, as well as a potential association with increased ISQ.
- 28 January 2025
- Published by Wiley in Journal of Prosthodontics
Open AccessImplant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs
Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.Materials and Methods: Two implant sites were prepared in the tibia of four minipigs. At the time of implant placement (T0), bone cortex thickness and Implant Stability Quotient (ISQ) were assessed. A bone specimen was collected from the tibia and used as the baseline for biomolecular analyses. X‐ray was taken after implant insertion. After 14 days (T14), a computed tomography (CT) scan of the tibias was conducted, and ISQ values were reassessed. Histological and biomolecular analyses were performed on bone sections containing the implant.Results: ISQ significantly increased from T0 to T14, in the absence of any correlation between the cortical thickness and ISQ. In two animals, CT showed a slight trabecular bone thickening adjacent to the implants and disorganized radiodense spots; in the other two, no trabecular osseodensification was evident. Newly formed bone was about 48% of the tissue around implants. At T14, an increase in osteogenic factors and a decrease in inflammatory molecules were observed.Conclusion: This study enhances understanding of the biological and clinical responses at bone implant sites following piezoelectric surgery. It highlights the relationship between the rise in certain osteogenic factors and new bone formation, as well as a potential association with increased ISQ.
- Open Access
- 10 July 2024
- Published by Open Exploration Publishing in Exploration of Medicine
- Vol. 5, 492
Correction: Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill
Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.
- 10 July 2024
- Published by Open Exploration Publishing in Exploration of Medicine
- Vol. 5, 492
Open AccessCorrection: Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill
Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.
- 5 July 2024
- Published by Open Exploration Publishing in Exploration of Medicine
- p. 467-476
Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill
Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.
- 5 July 2024
- Published by Open Exploration Publishing in Exploration of Medicine
- p. 467-476
Influence of dental implant site preparation method on three aspects of the site: magnetodynamic mallet versus conventional drill
Aim: Magnetodynamic surgery has assumed increasing importance in recent years. The purpose of the present study was to compare in vitro, using dry porcine ribs, two methods of dental implant site preparation (conventional drill and magnetic mallet) on three aspects of the site. These were the difference between the diameter of the site and the diameter of the last drill used (an index of the accuracy of the preparation), the weight loss of the specimen on which the site was prepared (index of the bone loss in the site), and the change of temperature at the site (an index of the change to the material at the site). Methods: Eight preformed pork ribs were chosen for the study. Four implant preparations were made on each rib, two with Magnetic Mallet (Meta Ergonomica, Turbigo, Italy) and two with traditional drills. Each bone sample was weighed before and after implant site preparation in order to calculate the amount of bone lost during preparation. The diameter of preparations was analyzed with the aid of an optical microscope (MZ6, Leica, Wetzlar, Germany) connected to a dedicated measurement software. For the evaluation of the temperature, eight preparation sites were marked. In correspondence of each preparation site, on the opposite side of the rib, a hole was made for the thermocouple (HI 91530K, Hanna Instruments, Padova, Italy). During the preparations, the thermocouple was kept inserted inside the control hole to record the temperature variation. The results were analyzed using appropriate statistical methods, such as the Kolmogorov-Smirnoff test and the Wilcoxon test. Results: It was found that mallet drill provided significantly higher accuracy of preparation, lower amount of damage at the site, and less change to the porcine rib test material at the preparation site. Conclusions: A possible clinical implication of this finding is discussed.
- Open Access
Roughness and SEM Analysis of Manual and Ultrasonic Instrumentation over Different Crown Materials for Dental Implants Restorations
The use of new prosthetic materials makes it necessary to establish adequate hygienic protocols. It was decided to make prosthetic crowns from four different materials: composite, lithium disilicate, metal ceramic, and zirconium, and to evaluate the effects on the surfaces of four different instruments through SEM and roughness analysis: manual steel curette, manual titanium curette, ultrasonic steel insert, and ultrasonic peek insert. Forty crowns were made, ten of each type of material. For each material, five crowns were manually instrumented with steel inserts (curette 11-12, PDT, Missoula, MT, USA) and titanium (Wingrove 3-4, PDT, Missoula, MT, USA) on the lingual and buccal surfaces, respectively, and the other five crowns were instrumented with an ultrasonic peek insert (ICS-IC1, Mectron, Carasco, Italy) on the buccal surface and steel (PS, EMS, Nyon, Switzerland) on the lingual surface. At this point, surface roughness analysis was carried out. The data were analyzed with a Kolmogorov–Smirnov test. Therefore, it was decided to conduct two analyses with a Kruskal–Wallis test and Bonferroni post hoc test. Then, the instrumented crowns were analyzed by SEM. The analysis of the data shows that the highest average roughness was within the composite group, while the best material appeared to be disilicate. Significant differences existed between the groups, between the materials, and between the different instruments (p-value < 0.05). In the qualitative analysis carried out by SEM, the classic steel insert eliminated the residues of golden finishing. The peek insert created alterations on all tested surfaces. The steel curette did not create particular problems, with the exception of zirconium, where it was possible to observe some scratch lines. Instrumentation with the titanium curette created deeper incisions than the steel curette in the composite and disilicate. The best results came from the ultrasonic steel insert, while the best material appeared to be disilicate.
Open AccessRoughness and SEM Analysis of Manual and Ultrasonic Instrumentation over Different Crown Materials for Dental Implants Restorations
The use of new prosthetic materials makes it necessary to establish adequate hygienic protocols. It was decided to make prosthetic crowns from four different materials: composite, lithium disilicate, metal ceramic, and zirconium, and to evaluate the effects on the surfaces of four different instruments through SEM and roughness analysis: manual steel curette, manual titanium curette, ultrasonic steel insert, and ultrasonic peek insert. Forty crowns were made, ten of each type of material. For each material, five crowns were manually instrumented with steel inserts (curette 11-12, PDT, Missoula, MT, USA) and titanium (Wingrove 3-4, PDT, Missoula, MT, USA) on the lingual and buccal surfaces, respectively, and the other five crowns were instrumented with an ultrasonic peek insert (ICS-IC1, Mectron, Carasco, Italy) on the buccal surface and steel (PS, EMS, Nyon, Switzerland) on the lingual surface. At this point, surface roughness analysis was carried out. The data were analyzed with a Kolmogorov–Smirnov test. Therefore, it was decided to conduct two analyses with a Kruskal–Wallis test and Bonferroni post hoc test. Then, the instrumented crowns were analyzed by SEM. The analysis of the data shows that the highest average roughness was within the composite group, while the best material appeared to be disilicate. Significant differences existed between the groups, between the materials, and between the different instruments (p-value < 0.05). In the qualitative analysis carried out by SEM, the classic steel insert eliminated the residues of golden finishing. The peek insert created alterations on all tested surfaces. The steel curette did not create particular problems, with the exception of zirconium, where it was possible to observe some scratch lines. Instrumentation with the titanium curette created deeper incisions than the steel curette in the composite and disilicate. The best results came from the ultrasonic steel insert, while the best material appeared to be disilicate.
- Open Access
Biomolecular, Histological, Clinical, and Radiological Analyses of Dental Implant Bone Sites Prepared Using Magnetic Mallet Technology: A Pilot Study in Animals
Background. A new instrumentation exploiting magneto-dynamic technology (mallet) proposed for implant site preparation was investigated. Methods. In the tibias of three minipigs, two sites were prepared by mallet and two by drill technique. Primary stability (ISQ) was detected after implant positioning (T0) and at 14 days (T14). X-rays and computed tomography were performed. At T14, bone samples were utilized for histological and biomolecular analyses. Results. In mallet sites, histological evaluations evidenced a significant increase in the newly formed bone, osteoblast number, and a smaller quantity of fibrous tissue. These results agree with the significant BMP-4 augmentation and the positive trend in other osteogenic factors (biological and radiological investigations). Major, albeit IL-10-controlled, inflammation was present. For both techniques, at T14 a significant ISQ increase was evidenced, but no significant difference was observed at T0 and T14 between the mallet and drill techniques. In mallet sites, lateral bone condensation was observed on computed tomography. Conclusions. Using biological, histological, clinical, and radiological analyses, this study first shows that the mallet technique is effective for implant site preparation. Based on its ability to cause osseocondensation and improve newly formed bone, mallet technology should be chosen in all clinical cases of poor bone quality.
Open AccessBiomolecular, Histological, Clinical, and Radiological Analyses of Dental Implant Bone Sites Prepared Using Magnetic Mallet Technology: A Pilot Study in Animals
Background. A new instrumentation exploiting magneto-dynamic technology (mallet) proposed for implant site preparation was investigated. Methods. In the tibias of three minipigs, two sites were prepared by mallet and two by drill technique. Primary stability (ISQ) was detected after implant positioning (T0) and at 14 days (T14). X-rays and computed tomography were performed. At T14, bone samples were utilized for histological and biomolecular analyses. Results. In mallet sites, histological evaluations evidenced a significant increase in the newly formed bone, osteoblast number, and a smaller quantity of fibrous tissue. These results agree with the significant BMP-4 augmentation and the positive trend in other osteogenic factors (biological and radiological investigations). Major, albeit IL-10-controlled, inflammation was present. For both techniques, at T14 a significant ISQ increase was evidenced, but no significant difference was observed at T0 and T14 between the mallet and drill techniques. In mallet sites, lateral bone condensation was observed on computed tomography. Conclusions. Using biological, histological, clinical, and radiological analyses, this study first shows that the mallet technique is effective for implant site preparation. Based on its ability to cause osseocondensation and improve newly formed bone, mallet technology should be chosen in all clinical cases of poor bone quality.
- Open Access
Role of rhBMP-7, Fibronectin, And Type I Collagen in Dental Implant Osseointegration Process: An Initial Pilot Study on Minipig Animals
Background: The biological factors involved in dental implant osseointegration need to be investigated to improve implant success. Methods: Twenty-four implants were inserted into the tibias of six minipigs. Bone samples were obtained at 7, 14, and 56 days. Biomolecular analyses evaluated mRNA of BMP-4, -7, Transforming Growth Factor-β2, Interleukin-1β, and Osteocalcin in sites treated with rhBMP-7, Type 1 Collagen, or Fibronectin (FN). Inflammation and osteogenesis were evaluated by histological analyses. Results: At 7 and 14 days, BMP-4 and BMP-7 increased in the sites prepared with rhBMP-7 and FN. BMP-7 remained greater at 56 days in rhBMP-7 and FN sites. BPM-4 at 7 and 14 days increased in Type 1 Collagen sites; BMP-7 increased from day 14. FN increased the TGF-β2 at all experimental times, whilst the rhBMP-7 only did so up to 7 days. IL-1β increased only in collagen-treated sites from 14 days. Osteocalcin was high in FN-treated sites. Neutrophilic granulocytes characterized the inflammatory infiltrate at 7 days, and mononuclear cells at 14 and 56 days. Conclusions: This initial pilot study, in a novel way, evidenced that Type 1 Collagen induced inflammation and did not stimulate bone production; conversely FN or rhBMP-7 showed neo-osteogenetic and anti-inflammatory properties when directly added into implant bone site.
Open AccessRole of rhBMP-7, Fibronectin, And Type I Collagen in Dental Implant Osseointegration Process: An Initial Pilot Study on Minipig Animals
Background: The biological factors involved in dental implant osseointegration need to be investigated to improve implant success. Methods: Twenty-four implants were inserted into the tibias of six minipigs. Bone samples were obtained at 7, 14, and 56 days. Biomolecular analyses evaluated mRNA of BMP-4, -7, Transforming Growth Factor-β2, Interleukin-1β, and Osteocalcin in sites treated with rhBMP-7, Type 1 Collagen, or Fibronectin (FN). Inflammation and osteogenesis were evaluated by histological analyses. Results: At 7 and 14 days, BMP-4 and BMP-7 increased in the sites prepared with rhBMP-7 and FN. BMP-7 remained greater at 56 days in rhBMP-7 and FN sites. BPM-4 at 7 and 14 days increased in Type 1 Collagen sites; BMP-7 increased from day 14. FN increased the TGF-β2 at all experimental times, whilst the rhBMP-7 only did so up to 7 days. IL-1β increased only in collagen-treated sites from 14 days. Osteocalcin was high in FN-treated sites. Neutrophilic granulocytes characterized the inflammatory infiltrate at 7 days, and mononuclear cells at 14 and 56 days. Conclusions: This initial pilot study, in a novel way, evidenced that Type 1 Collagen induced inflammation and did not stimulate bone production; conversely FN or rhBMP-7 showed neo-osteogenetic and anti-inflammatory properties when directly added into implant bone site.
- Open Access
In Vitro Simulation of Dental Implant Bridges Removal: Influence of Luting Agent and Abutments Geometry on Retrievability
Implant fixed dental prostheses are widely used for the treatment of edentulism, often preferred over the screw-retained ones. However, one of the main features of an implant-supported prosthesis is retrievability, which could be necessary in the case of implant complications. In this study, the retrievability of implant-fixed dental prostheses was investigated considering two of the main factors dental practitioners have to deal with: the abutments geometry and the luting agent. Impulsive forces were applied to dental bridge models to simulate crowns’ retrievability in clinical conditions. The number of impulses and the impulsive force delivered during each test were recorded and used as retrievability indexes. One-hundred-and-five tests were conducted on 21 combinations of bridges and luting agents, and a Kruskal-Wallis test was performed on the results. The abutment geometry significantly influenced the number of impulses needed for retrieval (p < 0.05), and a cement-dependent trend was observed as well. On the other hand, the forces measured during tests showed no clear correlation with bridge retrievability. The best retrievability was obtained with long, slightly tapered abutments and a temporary luting agent.
Open AccessIn Vitro Simulation of Dental Implant Bridges Removal: Influence of Luting Agent and Abutments Geometry on Retrievability
Implant fixed dental prostheses are widely used for the treatment of edentulism, often preferred over the screw-retained ones. However, one of the main features of an implant-supported prosthesis is retrievability, which could be necessary in the case of implant complications. In this study, the retrievability of implant-fixed dental prostheses was investigated considering two of the main factors dental practitioners have to deal with: the abutments geometry and the luting agent. Impulsive forces were applied to dental bridge models to simulate crowns’ retrievability in clinical conditions. The number of impulses and the impulsive force delivered during each test were recorded and used as retrievability indexes. One-hundred-and-five tests were conducted on 21 combinations of bridges and luting agents, and a Kruskal-Wallis test was performed on the results. The abutment geometry significantly influenced the number of impulses needed for retrieval (p < 0.05), and a cement-dependent trend was observed as well. On the other hand, the forces measured during tests showed no clear correlation with bridge retrievability. The best retrievability was obtained with long, slightly tapered abutments and a temporary luting agent.