Masakazu Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masakazu Ito has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Yasuhiro Hayashi
Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555, Japan
11 shared publications Kosuke Kurokawa
AES Center; Tokyo Institute of Technology; 2-12-1 Ookayama, Meguro-ku Tokyo 152-8550 Japan
8 shared publications- Ryuto Shigenobu
University of Fukui
7 shared publications - Akiko Takahashi
Faculty of Basic and Generic Researches, University of Fukui, Fukui 910-8507, Japan
5 shared publications Jun Yoshinaga
Advanced Collaborative Research Organization for Smart Society, Waseda University, Tokyo, Japan
5 shared publicationsKeiichi Komoto
4 shared publications
Latest Publications
- 1 May 2026
- Published by Springer Nature
- p. 361-373
Influence of Dynamic Pricing on Bottom-Up Household Technology Selection with Heat Pump Water Heater
- 1 May 2026
- Published by Springer Nature
- p. 361-373
Influence of Dynamic Pricing on Bottom-Up Household Technology Selection with Heat Pump Water Heater
- Open Access
An Adaptive Fairness-Based PV Curtailment Strategy: Simulation and Experimental Validation
The rapid growth of PV generation in the distribution grid has necessitated PV curtailment to prevent overvoltage violations, and this has raised fairness issues as some are curtailed disproportionately to others. This paper proposes an adaptive PV curtailment scheme that balances fairness with energy sales using a Curtailment Index (CI) employed to reallocate curtailed energy between PV systems. The CI-based approach dynamically adapts each inverter’s output in real time to provide voltage compliance while ensuring that no individual PV system experiences an overburden of curtailment. The method is evaluated through MATLAB simulations on a three-PV test distribution network and validated experimentally on the PAGLIA ORBA solar microgrid, where its performance is compared to equal-curtailment and unfair strategies. The findings indicate that the adaptive method helps integrate high PV penetration more equitably and efficiently, ensuring stable grid operation while minimizing financial losses for PV owners.
Open AccessAn Adaptive Fairness-Based PV Curtailment Strategy: Simulation and Experimental Validation
The rapid growth of PV generation in the distribution grid has necessitated PV curtailment to prevent overvoltage violations, and this has raised fairness issues as some are curtailed disproportionately to others. This paper proposes an adaptive PV curtailment scheme that balances fairness with energy sales using a Curtailment Index (CI) employed to reallocate curtailed energy between PV systems. The CI-based approach dynamically adapts each inverter’s output in real time to provide voltage compliance while ensuring that no individual PV system experiences an overburden of curtailment. The method is evaluated through MATLAB simulations on a three-PV test distribution network and validated experimentally on the PAGLIA ORBA solar microgrid, where its performance is compared to equal-curtailment and unfair strategies. The findings indicate that the adaptive method helps integrate high PV penetration more equitably and efficiently, ensuring stable grid operation while minimizing financial losses for PV owners.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-93
Comprehensive Data-Driven Framework for Statistical Transient Stability Analysis in Variable Inertia Power Systems Enabled by High-Throughput Simulation
The integration of renewable energy reduces electrical power system inertia, increasing vulnerability to disturbances. Conventional transient stability analysis suffers from event selectivity limitations. Hence, predetermined “worst case” scenarios overlook the risk associated with critical vulnerability patterns. This paper demonstrates that high-throughput simulation can systematically explore the entire contingency pattern to identify essential clusters of vulnerability. The automated framework reduces simulation time by 85 % while enabling statistical analysis across different inertia levels ($2 ~\mathrm{s}, 8 ~\mathrm{s}$, 16s) and disturbance magnitudes ($250-1000 \text{MW}$) using the IEEJ EAST 10-machine system. The RoCoF and Nadir results reveal distinct spatial vulnerability clustering, with buses 18, 19, 20, 36, 37, and 47 consistently exhibiting the highest impacts regardless of operating conditions. These topology-dependent vulnerability patterns require comprehensive rather than selective analysis for practical power system security assessment.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-93
Comprehensive Data-Driven Framework for Statistical Transient Stability Analysis in Variable Inertia Power Systems Enabled by High-Throughput Simulation
The integration of renewable energy reduces electrical power system inertia, increasing vulnerability to disturbances. Conventional transient stability analysis suffers from event selectivity limitations. Hence, predetermined “worst case” scenarios overlook the risk associated with critical vulnerability patterns. This paper demonstrates that high-throughput simulation can systematically explore the entire contingency pattern to identify essential clusters of vulnerability. The automated framework reduces simulation time by 85 % while enabling statistical analysis across different inertia levels ($2 ~\mathrm{s}, 8 ~\mathrm{s}$, 16s) and disturbance magnitudes ($250-1000 \text{MW}$) using the IEEJ EAST 10-machine system. The RoCoF and Nadir results reveal distinct spatial vulnerability clustering, with buses 18, 19, 20, 36, 37, and 47 consistently exhibiting the highest impacts regardless of operating conditions. These topology-dependent vulnerability patterns require comprehensive rather than selective analysis for practical power system security assessment.
- Open Access
Enhancing Fairness and Efficiency in PV Energy Curtailment: The Role of East–West-Facing Bifacial Installations in Radial Distribution Networks
Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east–west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening), which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s fairness index, the Gini index, and the Curtailment index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
Open AccessEnhancing Fairness and Efficiency in PV Energy Curtailment: The Role of East–West-Facing Bifacial Installations in Radial Distribution Networks
Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east–west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening), which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s fairness index, the Gini index, and the Curtailment index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
- Open Access
- 5 May 2025
- Published by MDPI AG in Preprints.org
Enhancing Fairness and Efficiency in PV Energy Curtailment: The Role of East-West Facing Bifacial Installations in Radial Distribution Networks
Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east-west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening) which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s Fairness Index, Gini Index, and Curtailment Index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
- 5 May 2025
- Published by MDPI AG in Preprints.org
Open AccessEnhancing Fairness and Efficiency in PV Energy Curtailment: The Role of East-West Facing Bifacial Installations in Radial Distribution Networks
Electricity market reforms and decreasing technology costs have propelled residential solar PV growth leading distribution network operators to face operational challenges including reverse power flows and voltage regulation during peak solar generation. Traditional mono-facial south-facing PV systems concentrate production at midday when demand may be low, leading to high curtailment, especially for downstream households. This study proposes vertically installed east-west-facing bifacial PV systems (BiE and BiW), characterized by two energy peaks (morning and evening) which are better aligned with residential demand and alleviate grid constraints. Using load flow simulations, the performance of vertical bifacial configurations was compared against mono-facial systems across PV capacities from 1 to 20 kW. Fairness in curtailment was evaluated at 10 kW using Jain’s Fairness Index, Gini Index, and Curtailment Index. Simulation results show that BiE and BiW installations, especially at higher capacities, not only generate more energy but also are better at managing curtailment. At 10 kW, BiE and BiW increased bid energies by 815 kWh and 787 kWh, and reduced curtailed energy by 1566 kWh and 1499 kWh, respectively. These findings highlight the potential of bifacial PV installations in mitigating curtailment and improving fairness in energy distribution, supporting the demand for residential PV systems.
- Open Access
- 1 February 2025
- Published by Elsevier in Results in Engineering
- Vol. 25
Real-time simulation comparison of the impact of inertia on grid following and grid forming inverter IGBT lifetime
- 1 February 2025
- Published by Elsevier in Results in Engineering
- Vol. 25
Open AccessReal-time simulation comparison of the impact of inertia on grid following and grid forming inverter IGBT lifetime
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Determination Method of Optimal LFC Capacity for Massive PV Installation in Conditions of Ramp Down During a Sunny Day
High penetration of renewable energy (RE) has a challenge for power system stability such as demand/supply imbalance. Generally, load frequency control (LFC) is applied to power demand/supply balancing management. The required LFC capacity is known to be about 2 to 3% of the power systems when the PV systems are not included. However, there are no clear criteria for LFC capacity of massive PV installation conditions. Thus, this paper proposes a method to determine the optimal LFC capacity in accordance with the PV installation level. This method consists of modeling, scheduling, and simulation of the power demand. The modeling is based on the modified AGC model. The scheduling part makes a unit commitment with forecasting of PV output data. Finally, power system numerical simulation is executed with iterative calculation. The simulation results of the proposed method shows that the optimal LFC capacity has a linear relationship with the growth of PV installation capacity. The method also revealed the linear relationship of LFC capacity regarding the striction level of the frequency criteria. This result means that the required optimal LFC capacity can be calculated without complicated power system simulations when the amount of PV installed is known.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Determination Method of Optimal LFC Capacity for Massive PV Installation in Conditions of Ramp Down During a Sunny Day
High penetration of renewable energy (RE) has a challenge for power system stability such as demand/supply imbalance. Generally, load frequency control (LFC) is applied to power demand/supply balancing management. The required LFC capacity is known to be about 2 to 3% of the power systems when the PV systems are not included. However, there are no clear criteria for LFC capacity of massive PV installation conditions. Thus, this paper proposes a method to determine the optimal LFC capacity in accordance with the PV installation level. This method consists of modeling, scheduling, and simulation of the power demand. The modeling is based on the modified AGC model. The scheduling part makes a unit commitment with forecasting of PV output data. Finally, power system numerical simulation is executed with iterative calculation. The simulation results of the proposed method shows that the optimal LFC capacity has a linear relationship with the growth of PV installation capacity. The method also revealed the linear relationship of LFC capacity regarding the striction level of the frequency criteria. This result means that the required optimal LFC capacity can be calculated without complicated power system simulations when the amount of PV installed is known.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Comparative Study of GFM-grid and GFL-grid in Islanded Operation
Global activity for a sustainable society has encouraged the transformation of the power system from synchronous generator-based generation to a massive integration of variable renewable energy (VRE) generation interfaced by power electronic converters. This transformation comes with stability concerns such as low-Nadir and a high rate of change of frequency (RoCoF). To increase the stability of grid-connected inverters, grid-following (GFL) and grid-forming inverter (GFM) control have been designed to behave like synchronous generators. However, for stable operations of grid forming and grid following inverters, inertia, damping, and frequency restoration control are necessary. This paper evaluates the comparison of the GFM grid and GFL grid in islanded operation. The control of the GFL and GFM grid is evaluated for a 100% integration of VRE through GFL and GFM based inverters. The simulation results show that the GFM-grid is more stable than the GFL-grid. The result also revealed that GFM can maintain a stable operation with 100% integration of VRE.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Comparative Study of GFM-grid and GFL-grid in Islanded Operation
Global activity for a sustainable society has encouraged the transformation of the power system from synchronous generator-based generation to a massive integration of variable renewable energy (VRE) generation interfaced by power electronic converters. This transformation comes with stability concerns such as low-Nadir and a high rate of change of frequency (RoCoF). To increase the stability of grid-connected inverters, grid-following (GFL) and grid-forming inverter (GFM) control have been designed to behave like synchronous generators. However, for stable operations of grid forming and grid following inverters, inertia, damping, and frequency restoration control are necessary. This paper evaluates the comparison of the GFM grid and GFL grid in islanded operation. The control of the GFL and GFM grid is evaluated for a 100% integration of VRE through GFL and GFM based inverters. The simulation results show that the GFM-grid is more stable than the GFL-grid. The result also revealed that GFM can maintain a stable operation with 100% integration of VRE.
- Open Access
- 1 March 2020
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 116
Multipurpose control and planning method for battery energy storage systems in distribution network with photovoltaic plant
- 1 March 2020
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 116
Open AccessMultipurpose control and planning method for battery energy storage systems in distribution network with photovoltaic plant
- Open Access
- 1 January 2019
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 9 (1) , 123-132
Scheduling method of wind power generation for electricity market using state-of-charge transition and forecast error
This study focuses on the trade of power from wind power plants (WPPs) at an electricity market. To trade power, operators should produce generation schedules for bids and then supply the same amount of energy as the schedules. However, power from WPPs tends to fluctuate, which complicates scheduling. This paper proposes three scheduling methods with an energy storage system (ESS) to solve this problem. The first method considers state-of-charge (SOC) transition to maintain the appropriate SOC and minimize the imbalance between supplied and scheduled energy. The second and third methods consider SOC transition and forecast errors. The second method uses a linear regression model to estimate forecast errors. The third method adopts a bagged trees model, which is a machine learning method, to directly estimate the adjusted forecast data considering errors. Five patterns of the rated power of the ESS are assumed, and these three methods are simulated on each power. In comparison with the basic method, whose schedules are the same as the forecast, the third method can reduce 84% of the imbalance from the schedules when the rated power of the ESS is the minimum. The proposed methods help develop further correct and practical scheduling methods.
- 1 January 2019
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 9 (1) , 123-132
Open AccessScheduling method of wind power generation for electricity market using state-of-charge transition and forecast error
This study focuses on the trade of power from wind power plants (WPPs) at an electricity market. To trade power, operators should produce generation schedules for bids and then supply the same amount of energy as the schedules. However, power from WPPs tends to fluctuate, which complicates scheduling. This paper proposes three scheduling methods with an energy storage system (ESS) to solve this problem. The first method considers state-of-charge (SOC) transition to maintain the appropriate SOC and minimize the imbalance between supplied and scheduled energy. The second and third methods consider SOC transition and forecast errors. The second method uses a linear regression model to estimate forecast errors. The third method adopts a bagged trees model, which is a machine learning method, to directly estimate the adjusted forecast data considering errors. Five patterns of the rated power of the ESS are assumed, and these three methods are simulated on each power. In comparison with the basic method, whose schedules are the same as the forecast, the third method can reduce 84% of the imbalance from the schedules when the rated power of the ESS is the minimum. The proposed methods help develop further correct and practical scheduling methods.