MAMichelle de Medeiros Aires

Michelle de Medeiros Aires

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michelle de Medeiros Aires has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A comparative investigation of plasma nitriding and oxy-nitriding treatment on cells and bacterial interaction on titanium surfaces

    by M.M. Aires, M. Naeem, R.F. Melo-Silveira, A.J. Macedo, I.V. de Souza, H.A.O. Rocha, R.R.M. de Sousa, C.ALves Júnior


  • Investigating potential, current, and voltage in the deposition of calcium phosphate-based films using plasma electrolytic oxidation

    by Anderson Wagner Alves de Menezes, Ana Maria Félix Libório, Bruna Teixeira Costa, Luciano Lucas Fernandes Lima, Michelle de Medeiros Aires, Rômulo Ribeiro Magalhães de Sousa, Thércio Henrique de Carvalho Costa, Igor Oliveira Nascimento, Tharsia Cristiany de Carvalho Costa, Michelle Cequeira Feitor

  • Open Access

    Novel Synthesis of Zinc Oxide on Cotton Fabric by Cathodic Cage Plasma Deposition for Photocatalytic and Antibacterial Performance

    by Rayane Saory Medeiros dos Santos, Muhammad Naeem, Anderson Lucas da Silva, Michelle De Medeiros Aires, Rômulo R. Magalhães de Sousa, Thércio Henrique de Carvalho Costa, Hugo Alexandre Oliveira Rocha, Maria Celeste Nunes De Melo, Michelle Cequeira Feitor

    Cotton fabrics with zinc oxide (ZnO) coating are of significant interest due to their excellent antibacterial performance. Thus, they are widely in demand in the textile industry due to their medical and hygienic properties. However, conventional techniques used to deposit ZnO on fabric require long processing times in deposition, complex and expensive equipment, and multiple steps for deposition, such as a separate process for nanoparticle synthesis and subsequent deposition on fabric. In this study, we proposed a new method for the deposition of ZnO on fabric, using cathodic cage plasma deposition (CCPD), which is commonly used for coating deposition on conductor materials and is not widely used for fabric due to the temperature sensitivity of the fabric. The effect of gas composition, including argon and a hydrogen–argon mixture, on the properties of ZnO deposition is investigated. The deposited samples are characterized by XRD, SEM, EDS, photocatalytic, and antibacterial performance against Staphylococcus aureus and Pseudomonas aeruginosa bacteria. It is observed that ZnO-deposited cotton fabric exhibits excellent photocatalytic degradation of methylene blue and antibacterial performance, specifically when a hydrogen–argon mixture is used in CCPD. The results demonstrate that CCPD can be used effectively for ZnO deposition on cotton fabric; this system is already used in industrial-scale applications and is thus expected to be of significant interest to garment manufacturers and hospitals.


  • Effect of plasma‐nitrided titanium surfaces on the differentiation of pre‐osteoblastic cells

    by Carlos Eduardo B. Moura, Moacir F. Queiroz Neto, Janine Karla F. S. Braz, Michelle de Medeiros Aires, Naisandra B. Silva Farias, Carlos Augusto G. Barboza, Geraldo B. Cavalcanti Júnior, Hugo Alexandre O. Rocha, Clodomiro Alves Junior

    A titanium surface nitrided by plasma contains nitrogen ions that guarantee resistance to corrosion and biocompatibility. Despite this, no descriptions concerning the influence of the expression of cell adhesion proteins and their influence on osteogenic cell differentiation are available. Thus, the present study aimed to assess the response of murine pre‐osteoblastic cells (MC3T3‐E1) cultured on nitrided titanium surfaces. Pre‐osteoblastic cells were grown on polished titanium discs, used as controls, and on previously characterized plasma‐nitrided titanium discs. Cells from both groups were submitted to the MTT cell viability test. The expressions of α5, α2, and β1 integrin were assessed by flow cytometry and immunofluorescence, while osteocalcin expression was assessed by flow cytometry. The nitrided surface presented higher α2 and β1 integrin expressions, as well as osteocalcin expression, when compared to the polished surface, with no alterations in cell viability. These findings seem to suggest that the plasma nitriding treatment produces a titanium surface with the potential for effective in vitro osseointegration.


  • Titanium Surface Chemical Composition Interferes in the Pseudomonas aeruginosa Biofilm Formation

    by Antonio Nunes Filho, Michelle de Medeiros Aires, Danilo Cavalcante Braz, Ruth Hinrichs, Alexandre José Macedo, Clodomiro Alves Jr

    Bacterial adhesion on three different surfaces: untreated Ti, plasma nitriding, and plasma carbonitriding Ti substrates were investigated. The samples were placed in bacterial cultures of Pseudomonas aeruginosa to assess biofilm formation. The correlation between the amount of bacteria attached to the surface after a lapse of time with nanotopography and physicochemical properties was performed. TiN showed the highest capacity to avoid bacterial adhesion, while presenting intermediate roughness and wettability. Although the surface of TiCN had the highest surface roughness and low contact angle (high wettability), bacterial adhesion was intermediate on this sample. Untreated Ti, even though presenting a smooth surface and low wettability, had the highest tendency to form biofilms.


  • Open Access

    Minimizing Pseudomonas aeruginosa adhesion to titanium surfaces by a plasma nitriding process

    by Michelle de Medeiros Aires, Janine Treter, Antônio Nunes Filho, Igor Oliveira Nascimento, Alexandre José Macedo, Clodomiro Alves Júnior

    The research of the interaction between bacteria-surface has great importance for titanium biomedical applications once microorganisms offer risks because promoting implant loss. Therefore, study bacterial adhesion and colonization on titanium is interesting because are principal factors infections pathogeny on biomaterials. In this study, commercial grade II titanium was submitted to nitriding treatment to plasma at 2.2 mbar, using gas mixtures of 80% hydrogen (H2) and 20% nitrogen (N2) during 1 hour and 3 hour. The surfaces were physically and chemically characterized. In order to evaluate bacterial response, the surfaces were exposed to Pseudomonas aeruginosa. The titanium surface modified in nitriding plasma, although exposes a higher roughness as compared with untreated samples, exhibited lower bacterial growth. The nitrided sample for 3 hour exhibited the higher amount of TiN phase and the higher concentration of atomic nitrogen on surface and lower bacterial adhered count. These results were confirmed by scanning electron microscopy. Based on these results can be said to the thermochemical treatment of plasma nitriding on titanium samples results a significant reduction of adherence of Pseudomonas aeruginosa. It was found that the Ti surface nitrided offers significant reduction of bacterial adherence which prevent biofilm formation and offersing lower risk of infection and implant remotion.


  • Influence of Oxynitrided Surface in the Production of a Less Susceptible Titanium Surface to Skin-Borne Bacterial Adhesion

    by Michelle de Medeiros Aires, Janine Treter, Danilo Cavalcante Braz, Cristiano Krug, Alexandre José Macedo, Clodomiro Alves Júnior

    There is a growing quest for an ideal biomaterial that shows appropriate cellular response and is not susceptible to microbial adhesion. In this study, commercial grade II titanium was submitted to RF/DC plasma surface modification at 2.2 mbar, using gas mixtures of argon, nitrogen, and oxygen at proportions 4:1:2 and 4:1:3. The surfaces were physically and chemically characterized. In order to evaluate bacterial response, the surfaces were exposed to Staphylococcus epidermidis. Oxynitrided samples, although having a higher roughness as compared with untreated samples, exhibited lower bacterial growth. This observation is probably due to the formation of different crystalline phases of nitrides and oxides caused by plasma treatment. The surface with highest contact angle and highest surface tension showed lower bacterial adhesion. These results were confirmed by scanning electron microscopy. The role of nitrogen in reducing bacterial adhesion is clear when this material is compared with untreated titanium, on which only an oxide film is present.