David C. Mackenzie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David C. Mackenzie has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Vicki E. Noble
Department of Emergency Medicine, University Hospital, Cleveland, OH, United States of America
7 shared publicationsAndrew S. Liteplo
Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA, United States of America
5 shared publicationsAlice F. Murray
Point-of-Care Ultrasound in Resource Limited Environments, Boston, MA, USA
2 shared publicationsAnthony J. Dean
Point-of-Care Ultrasound in Resource Limited Environments, Boston, MA, USA
2 shared publicationsJoshua S. Rempell
Department of Emergency Medicine, Brigham and Women's Hospital, Boston, MA, USA
2 shared publicationsOtto Liebmann
2 shared publications
Latest Publications
- 1 November 2021
- Published by The Institution of Structural Engineers in The Structural Engineer
- Vol. 99 (11) , 24-25
Safety matters: why experience and communication are key to managing risk
David MacKenzie discusses the importance of structural safety in the design and construction phase and ways in which risks can be mitigated.
- 1 November 2021
- Published by The Institution of Structural Engineers in The Structural Engineer
- Vol. 99 (11) , 24-25
Safety matters: why experience and communication are key to managing risk
David MacKenzie discusses the importance of structural safety in the design and construction phase and ways in which risks can be mitigated.
- 1 January 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (1) , 123-126
Test performance of point-of-care ultrasound for gastric content
- 1 January 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (1) , 123-126
Test performance of point-of-care ultrasound for gastric content
- Open Access
- 28 September 2018
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 5 (3) , 199-203
Dural sinus thrombosis identified by point-of-care ultrasound
Dural sinus thrombosis (DST), or cerebral venous thrombosis, is an uncommon cause of stroke. It has a variable presentation, and the symptoms and signs can be non-specific. The diagnosis of DST can be difficult to make and is often delayed or missed. Computed tomography venography or magnetic resonance venography are the typical imaging modalities used to diagnose DST. However, computed tomography venography and magnetic resonance venography both have limitation for emergency department patients. In this article, we report the use of point-of-care ultrasound to facilitate the diagnosis of DST.
- 28 September 2018
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 5 (3) , 199-203
Open AccessDural sinus thrombosis identified by point-of-care ultrasound
Dural sinus thrombosis (DST), or cerebral venous thrombosis, is an uncommon cause of stroke. It has a variable presentation, and the symptoms and signs can be non-specific. The diagnosis of DST can be difficult to make and is often delayed or missed. Computed tomography venography or magnetic resonance venography are the typical imaging modalities used to diagnose DST. However, computed tomography venography and magnetic resonance venography both have limitation for emergency department patients. In this article, we report the use of point-of-care ultrasound to facilitate the diagnosis of DST.
- 9 November 2017
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 37 (6) , 1397-1402
Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea
Objectives: Unstructured clinical assessments of dehydration in children are inaccurate. Point‐of‐care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh.Methods: Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%–9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration.Results: A total of 350 children (0–60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295–351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration.Conclusions: The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea.
- 9 November 2017
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 37 (6) , 1397-1402
Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea
Objectives: Unstructured clinical assessments of dehydration in children are inaccurate. Point‐of‐care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh.Methods: Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%–9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration.Results: A total of 350 children (0–60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295–351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration.Conclusions: The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea.
- Open Access
- 6 March 2017
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 4 (1) , 60-63
Spontaneous elbow hemarthrosis identified by point-of-care ultrasound
Traumatic or spontaneous hemarthroses are an important cause of joint effusions, and can complicate innate or acquired coagulopathies. The elbow is an unusual location for a spontaneous hemarthrosis; we describe a previously unreported case of warfarin-induced spontaneous elbow hemarthrosis, diagnosed by point-of-care ultrasound. On the basis of clinical and ultrasound findings arthrocentesis was deferred, and the patient was successfully treated with warfarin reversal and conservative care. Physical examination is unreliable for the detection of a joint effusion, and misdiagnosis and can lead to unnecessary investigation or resource use. Point-of-care ultrasound allows accurate, prompt, direct visualization of a joint effusion, and non-invasive confirmation of a hemarthrosis. Ultrasound can facilitate accurate diagnosis and characterization of joint effusions to improve the care of patients with coagulopathy.
- 6 March 2017
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 4 (1) , 60-63
Open AccessSpontaneous elbow hemarthrosis identified by point-of-care ultrasound
Traumatic or spontaneous hemarthroses are an important cause of joint effusions, and can complicate innate or acquired coagulopathies. The elbow is an unusual location for a spontaneous hemarthrosis; we describe a previously unreported case of warfarin-induced spontaneous elbow hemarthrosis, diagnosed by point-of-care ultrasound. On the basis of clinical and ultrasound findings arthrocentesis was deferred, and the patient was successfully treated with warfarin reversal and conservative care. Physical examination is unreliable for the detection of a joint effusion, and misdiagnosis and can lead to unnecessary investigation or resource use. Point-of-care ultrasound allows accurate, prompt, direct visualization of a joint effusion, and non-invasive confirmation of a hemarthrosis. Ultrasound can facilitate accurate diagnosis and characterization of joint effusions to improve the care of patients with coagulopathy.
- 19 October 2016
- Published by Wiley in Tropical Medicine & International Health
- Vol. 21 (12) , 1531-1538
Intensive point‐of‐care ultrasound training with long‐term follow‐up in a cohort of Rwandan physicians
Objective: We delivered a point‐of‐care ultrasound training programme in a resource‐limited setting in Rwanda, and sought to determine participants' knowledge and skill retention. We also measured trainees' assessment of the usefulness of ultrasound in clinical practice.Methods: This was a prospective cohort study of 17 Rwandan physicians participating in a point‐of‐care ultrasound training programme. The follow‐up period was 1 year. Participants completed a 10‐day ultrasound course, with follow‐up training delivered over the subsequent 12 months. Trainee knowledge acquisition and skill retention were assessed via observed structured clinical examinations (OSCEs) administered at six points during the study, and an image‐based assessment completed at three points.Results: Trainees reported minimal structured ultrasound education and little confidence using point‐of‐care ultrasound before the training. Mean scores on the image‐based assessment increased from 36.9% (95% CI 32–41.8%) before the initial 10‐day training to 74.3% afterwards (95% CI 69.4–79.2; P < 0.001). The mean score on the initial OSCE after the introductory course was 81.7% (95% CI 78–85.4%). The mean OSCE performance at each subsequent evaluation was at least 75%, and the mean OSCE score at the 58‐week follow up was 84.9% (95% CI 80.9–88.9%).Conclusions: Physicians providing acute care in a resource‐limited setting demonstrated sustained improvement in their ultrasound knowledge and skill 1 year after completing a clinical ultrasound training programme. They also reported improvements in their ability to provide patient care and in job satisfaction.
- 19 October 2016
- Published by Wiley in Tropical Medicine & International Health
- Vol. 21 (12) , 1531-1538
Intensive point‐of‐care ultrasound training with long‐term follow‐up in a cohort of Rwandan physicians
Objective: We delivered a point‐of‐care ultrasound training programme in a resource‐limited setting in Rwanda, and sought to determine participants' knowledge and skill retention. We also measured trainees' assessment of the usefulness of ultrasound in clinical practice.Methods: This was a prospective cohort study of 17 Rwandan physicians participating in a point‐of‐care ultrasound training programme. The follow‐up period was 1 year. Participants completed a 10‐day ultrasound course, with follow‐up training delivered over the subsequent 12 months. Trainee knowledge acquisition and skill retention were assessed via observed structured clinical examinations (OSCEs) administered at six points during the study, and an image‐based assessment completed at three points.Results: Trainees reported minimal structured ultrasound education and little confidence using point‐of‐care ultrasound before the training. Mean scores on the image‐based assessment increased from 36.9% (95% CI 32–41.8%) before the initial 10‐day training to 74.3% afterwards (95% CI 69.4–79.2; P < 0.001). The mean score on the initial OSCE after the introductory course was 81.7% (95% CI 78–85.4%). The mean OSCE performance at each subsequent evaluation was at least 75%, and the mean OSCE score at the 58‐week follow up was 84.9% (95% CI 80.9–88.9%).Conclusions: Physicians providing acute care in a resource‐limited setting demonstrated sustained improvement in their ultrasound knowledge and skill 1 year after completing a clinical ultrasound training programme. They also reported improvements in their ability to provide patient care and in job satisfaction.
- 1 September 2015
- Published by Elsevier in Annals of Emergency Medicine
- Vol. 66 (3) , 277-282.e1
Carotid Flow Time Changes With Volume Status in Acute Blood Loss
- 1 September 2015
- Published by Elsevier in Annals of Emergency Medicine
- Vol. 66 (3) , 277-282.e1
Carotid Flow Time Changes With Volume Status in Acute Blood Loss
- 1 June 2015
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 48 (6) , 699-701
Aortoenteric Fistula Identified By Clinical Ultrasound
- 1 June 2015
- Published by Elsevier in The Journal of Emergency Medicine
- Vol. 48 (6) , 699-701
Aortoenteric Fistula Identified By Clinical Ultrasound
- Open Access
- 30 December 2014
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 1 (2) , 67-77
Assessing volume status and fluid responsiveness in the emergency department
Resuscitation with intravenous fluid can restore intravascular volume and improve stroke volume. However, in unstable patients, approximately 50% of fluid boluses fail to improve cardiac output as intended. Increasing evidence suggests that excess fluid may worsen patient outcomes. Clinical examination and vital signs are unreliable predictors of the response to a fluid challenge. We review the importance of fluid management in the critically ill, methods of evaluating volume status, and tools to predict fluid responsiveness.
- 30 December 2014
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 1 (2) , 67-77
Open AccessAssessing volume status and fluid responsiveness in the emergency department
Resuscitation with intravenous fluid can restore intravascular volume and improve stroke volume. However, in unstable patients, approximately 50% of fluid boluses fail to improve cardiac output as intended. Increasing evidence suggests that excess fluid may worsen patient outcomes. Clinical examination and vital signs are unreliable predictors of the response to a fluid challenge. We review the importance of fluid management in the critically ill, methods of evaluating volume status, and tools to predict fluid responsiveness.