KPKarin. R. Pillunat

Karin. R. Pillunat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karin. R. Pillunat has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Lutz E. Pillunat

    Department of Ophthalmology, Medical Faculty Carl Gustav Carus, Technical University, Dresden, Germany

    21 shared publications
  • Eberhard Spoerl

    Tech Univ, Dept Ophthalmol, Med Fac Carl Gustav Carus, Fetscherstr, Dresden, Germany

    8 shared publications
  • Robert Herber

    Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Dresden, Germany

    6 shared publications
  • Carolin S. Jasper

    Department of Ophthalmology, Medical Faculty Carl Gustav Carus, Technische Universität, Fetscherstrasse 74, 01307 Dresden, Germany

    5 shared publications
  • Robert Herber

    Department of Ophthalmology, Univ. Hospital Carl Gustav Carus, TU Dresden, Dresden, Germany

    4 shared publications
  • Cosima Hermann

    Department of Ophthalmology, Medical Faculty Carl Gustav Carus, Technische Universität, Dresden, Germany

    3 shared publications

Latest Publications

  • Open Access

    Effectiveness and safety of VISULAS® green selective laser trabeculoplasty: 12 months retrospective data

    by Karin R. Pillunat, Florian T. A. Kretz, Stefan Koinzer, Philipp Müller, Lutz E. Pillunat, Karsten Klabe

    To report the safety and effectiveness of selective laser trabeculoplasty (SLT) using the SLT mode of the VISULAS® green laser in patients with primary open-angle glaucoma (POAG). Twelve months results are presented. Retrospective extension in 4 German centers of an initially prospective interventional multicenter 3-month clinical investigation using the VISULAS® green SLT (Carl Zeiss Meditec AG, Jena, Germany) in patients with POAG who either needed treatment escalation or commenced treatment and had an IOP ≥ 17mmHg at baseline, with no previous glaucoma or other ocular surgery. Non-overlapping laser spots (100) were applied in a single session to 360° of the trabecular meshwork (TM). Glaucoma medications were not changed up to the 3-month visit. From 3 to 12 months, patients were managed according to routine standard of care. Outcome measures included IOP reduction, further glaucoma interventions, and adverse events from baseline to month 12. 25 eyes of 25 POAG patients (mean age 65.8 ± 8.5; modified intention to treat – mITT –group) were included in the extension study. Six eyes (24%) underwent additional glaucoma treatment or changed glaucoma therapy; the remaining 19 eyes (76%) had stable glaucoma therapy (SGT group) with no further glaucoma intervention or change in glaucoma medications (mean number of preoperative glaucoma medications: 2.3 ± 1.34). In the SGT group, mean baseline IOP (mmHg) was reduced from 20.0 ± 2.11 at baseline to 17.4 ± 3.25 and 16.2 ± 1.83 at 6 to 12 months, respectively (p < 0.0001): 52.6% had ≥ 20% IOP reduction at 12 months. Potential device- or procedure-related adverse events were mild to moderate and resolved without sequelae. SLT performed with the VISULAS® green laser reduced IOP in eyes with POAG up to 12 months with no relevant safety issues. The results are comparable to other reported SLT studies.

  • Early Results of PRESERFLO TM MicroShunt for Primary Open-angle Glaucoma in Caucasian Patients

    by Karin R. Pillunat, Robert Dr. Rer. Medic. Herber, Melanie Jamke, Carolin S. Jasper, Maike A. Haase, Anna S. Manseck, Lutz E. Pillunat

    Precis: The PRESERFLO MicroShunt effectively lowered intraocular pressure in primary high and normal pressure open-angle glaucoma. Purpose: To evaluate the efficacy and safety of the PRESERFLOTM MicroShunt in patients with primary open-angle glaucoma (POAG) and the two variants high (HPG) and normal pressure glaucoma (NPG) after one year. Methods: Single-center prospective interventional case series consecutively including eyes of White/European patients with POAG, who received the PRESERFLOTM MicroShunt as a primary and stand-alone glaucoma intervention. Primary outcome measures: change in mean 24-h IOP (mdIOP, mean of 6 measurements), peak IOP, IOP fluctuations, anti-glaucoma medications, and success rates. Secondary outcome measures: visual acuity, visual fields, complications, surgical interventions, and adverse events. Results: Forty-two eyes of 42 POAG patients, 29 in the HPG and 13 in the NPG group, were analyzed after 1-year follow-ups. Median [Q25, Q75] mdIOP (mmHg) dropped by 30% from 16.5 [13.7-27.3] to 12.8 [10.2-14.5] in the HPG and by 40% from 14.3 [13.3-16.0] to 9.5 [8.3-11.1] in the NPG group, with a median postoperative medication use of 0 [0-0] in both groups. At one year, 92.5% of eyes were medication-free versus 0% preoperatively. The reduction of mdIOP (P=1.0), peak IOP (P=0.932), IOP fluctuations (P=0.142) and the rate of interventions (P=0.298) were not statistically significantly different between the HPG and NPG group. None of the patients experienced severe adverse events or loss of vision. Conclusions: Effective and safe intraocular pressure lowering was observed one year following MicroShunt implantation for primary HPG and NPG in white patients of European descent.


  • Open Access

    The retinal venous pressure at different levels of airway pressure measured with a new method

    by Johanna L. Baumgärtner, Richard Stodtmeister, René Mauer, Lutz E. Pillunat, Karin R. Pillunat

    Purpose: This study is to investigate the increase in retinal venous pressure (RVP) induced by a stepwise increase in airway pressure (AirP) using the new IOPstim method, which is designed to artificially increase the intraocular pressure (IOP) and thus to stimulate vascular pulsation. Methods: Twenty-eight healthy subjects were examined in the left eye. The RVP was measured at baseline and at four different levels of AirP (10, 20, 30, and 40 mmHg) using the new IOPstim method: a half balloon of 8 mm diameter is inflated laterally to the cornea under observation of the central retinal vein. As soon as the vein pulsates at a certain AirP level, the IOP is measured with a commercially available tonometer, which then corresponds to the RVP. Results: Spontaneous venous pulsation was observed in all study participants. The mean RVP values at baseline and at the AirP levels of 10, 20, 30, and 40 mmHg were 17.6 ± 2.8 mmHg; 20.1 ± 3.0 mmHg; 22.1 ± 3.5 mmHg; 24.3 ± 3.7 mmHg, and 26.6 ± 4.2 mmHg, respectively. The mean RVP values of each AirP level were statistically significantly different from each other in pairwise comparison. In a linear mixed model, the effect of AirP on RVP was highly significant (p < 0.001). In the model, a 10-mmHg increase in AirP resulted in a linear increase in RVP of 2.2 mmHg. Conclusion: An increase in AirP was accompanied by a linear increase in RVP. The influence of AirP on RVP, and thus on retinal perfusion pressure during the Valsalva maneuver, is less than was assumed based on previous studies in which contact lens dynamometry was used.

  • Open Access

    Measurement of the retinal venous pressure with a new instrument in patients with primary open angle glaucoma

    by Richard Stodtmeister, Aline Menzel, Anna Klimova, Robert Herber, Karin. R. Pillunat, Lutz E. Pillunat

    Purpose: To compare the results of retinal venous pressure (RVP) measurement performed with contact lens dynamometry (CLD) and with the new IOPstim. Methods: In this cross-sectional study, we included 36 patients with primary open angle glaucoma with a median age (Q25; Q75) of 74 (64; 77) years (m/f = 18/18), baseline intraocular pressure (IOP): 13.9 (12.2; 15.1) mmHg. Median mean defect: − 5.8 (− 11.9; − 2.6) db. Principle of the IOPstim: an empty balloon with a diameter of 8 mm is positioned on the eye, laterally of the limbus. Under observation of the central retinal vein (CRV), the examiner inflates the balloon. As soon as the CRV starts pulsation, the inflation is stopped and the IOP is measured, equaling the RVP at this moment. In the CLD, the pulsation of the CRV is observed with a contact lens. The RVP is calculated from the attachment force applied when pulsation appears. Course of examinations: Three single measurements of RVP in quick succession with both methods. The sequence of the two methods was randomized. The means of the three RVP measurements were compared. Results: Pressures in mmHg. RVP: IOPstim: 19.4 ± 5.4 (mean ± SD), CLD: 20.3 ± 5.9. Range of three single measurements: IOPstim: 2.9 ± 1.5, CLD: 2.2 ± 1.1. The differences were RVPIOPstim − RVPCLD = − 0.94 ± 1.15, and approximately normally distributed. Bland–Altman analysis: only one data point was 0.5 mmHg higher than the upper line of agreement. The confidence interval of this line was 0.65 mmHg. Concordance correlation coefficient according to Lin (CCC): 0.96. Intraclass correlation coefficient: both methods, 0.94. Conclusion: In both methods, the range of the single measurements may be taken as a sign of good reliability, the CCC of 0.96 as a sign of a very good agreement. At the mean, the IOPstim RVP values were 1 mmHg lower than those obtained with the CLD. This difference may be due to the different directions of the prevailing force vectors induced by the instruments. The IOPstim seems applicable in glaucoma diagnostics.


  • Open Access

    PRESERFLO ™ MicroShunt versus trabeculectomy: 1-year results on efficacy and safety

    by Melanie Jamke, Robert Herber, Maike A. Haase, Carolin S. Jasper, Lutz E. Pillunat, Karin R. Pillunat

    Purpose: To compare the efficacy and safety of the PRESERFLO™ MicroShunt versus trabeculectomy in patients with primary open-angle glaucoma (POAG) after one year. Patients and methods: Institutional prospective interventional cohort study comparing eyes with POAG, which had received the PRESERFLO™ MicroShunt versus trabeculectomy. The MicroShunt group was matched with the trabeculectomy group for age, known duration of disease, and number and classes of intraocular pressure (IOP) lowering medications to have similar conjunctival conditions. The study is part of the Dresden Glaucoma and Treatment Study, using a uniform study design, with the same inclusion and exclusion criteria, follow-ups and standardized definitions of success and failure for both procedures. Primary outcome measures: mean diurnal IOP (mdIOP, mean of 6 measurements), peak IOP, and IOP fluctuations. Secondary outcome measures: success rates, number of IOP lowering medications, visual acuity, visual fields, complications, surgical interventions, and adverse events. Results: Sixty eyes of 60 patients, 30 in each group, were analyzed after 1-year follow-ups. Median [Q25, Q75] mdIOP (mmHg) dropped from 16.2 [13.8–21.5] to 10.5 [8.9–13.5] in the MicroShunt and from 17.6 [15.6–24.0] to 11.1 [9.5–12.3] in the trabeculectomy group, both without glaucoma medications. Reduction of mdIOP (P = .596), peak IOP (P = .702), and IOP fluctuations (P = .528) was not statistically significantly different between groups. The rate of interventions was statistically significantly higher in the trabeculectomy group, especially in the early postoperative period (P = .018). None of the patients experienced severe adverse events. Conclusion: Both procedures are equally effective and safe in lowering mdIOP, peak IOP and IOP fluctuations in patients with POAG, one year after surgery. Clinical trial registration: NCT02959242.


  • Open Access

    Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients

    by Lisa Ramm, Robert Herber, Georg Lorenz, Carolin S Jasper, Lutz E Pillunat, Karin R Pillunat

    Purpose: To characterize differences in corneal biomechanics in high (HPG) and normal pressure (NPG) primary open-angle glaucoma, and its association to disease severity. Methods: Corneal biomechanical properties were measured using the Ocular Response Analyzer (ORA) and the dynamic Scheimpflug-Analyzer Corvis ST (CST). Disease severity was functionally assessed by automated perimetry (Humphrey field analyzer) and structurally with the Heidelberg Retina Tomograph. To avoid a possible falsification by intraocular pressure, central corneal thickness and age, which strongly influence ORA and CST measurements, group matching was performed. Linear mixed models and generalized estimating equations were used to consider inter-eye correlation. Results: Following group matching, 60 eyes of 38 HPG and 103 eyes of 60 NPG patients were included. ORA measurement revealed a higher CRF in HPG than in NPG (P < 0.001). Additionally, the CST parameter integrated radius (P < 0.001) was significantly different between HPG and NPG. The parameter SSI (P < 0.001) representing corneal stiffness was higher in HPG than in NPG. Furthermore, regression analysis revealed associations between biomechanical parameters and indicators of disease severity. In HPG, SSI correlated to RNFL thickness. In NPG, dependencies between biomechanical readings and rim area, MD, and PSD were shown. Conclusion: Significant differences in corneal biomechanical properties were detectable between HPG and NPG patients which might indicate different pathophysiological mechanisms underlying in both entities. Moreover, biomechanical parameters correlated to functional and structural indices of diseases severity. A reduced corneal deformation measured by dynamic methods was associated to advanced glaucomatous damage.


  • Open Access

    Effectiveness and safety of VISULAS® green selective laser trabeculoplasty: a prospective, interventional multicenter clinical investigation

    by Karin R. Pillunat, Florian T. A. Kretz, Stefan Koinzer, Christoph Ehlken, Lutz E. Pillunat, Karsten Klabe

    Purpose To evaluate the effectiveness and safety of Selective Laser Trabeculoplasty (SLT) with the SLT mode of the VISULAS® green laser in patients with primary open-angle glaucoma (POAG). Methods This prospective, interventional multicenter clinical investigation included patients with POAG who either needed a treatment escalation because the individual intraocular pressure (IOP) target was not met or treatment initiation and had an IOP ≥ 17 mmHg at baseline in the study eye. The study was conducted in five research centers across Germany. Approximately 100 laser applications were delivered to 360° of the trabecular meshwork. Glaucoma medications were not modified during the 3-month follow-up to allow evaluation of the sole effect of VISULAS® green with SLT. Efficacy outcomes were postoperatively absolute and relative IOP changes at 1 and 3 months. Safety outcomes analyzed the rate of intra- and postoperative adverse events. Results Thirty-four eyes of 34 POAG patients were included. The overall mean number of preoperative glaucoma medications was 2.2 ± 1.4 in 29 treated eyes, 5 eyes were treatment naïve. Mean baseline IOP (mmHg) was 21.0 ± 2.69 and was reduced by − 3.53 ± 3.34 [95% CI − 4.61; − 2.45] and − 3.59 ± 3.41 [95% CI − 4.64; − 2.53] at the 1- and 3-month follow-up, respectively (p < 0.0001), with 48.5% of cases achieving a ≥ 20% IOP reduction at 3 months [95% CI = 30.8%; 66.5%]. The mean relative IOP reduction was − 16.4% and − 16.3% at 1 and 3 months, respectively (p < 0.0001). Potentially device- or procedure-related adverse events were mild to moderate and included 3 postoperative IOP-spikes and 6 reports regarding eye pain and discomfort. All were resolved without sequelae. Conclusions SLT performed with the VISULAS® green laser achieved clinically significant additional IOP reductions in medically treated as well as in treatment naïve eyes with POAG and there were no relevant safety issues. The results are comparable to other reported SLT studies.


  • Open Access

    Efficacy of selective laser trabeculoplasty on lowering intraocular pressure fluctuations and nocturnal peak intraocular pressure in treated primary open-angle glaucoma patients

    by Karin R. Pillunat, Greta A. Kocket, Robert Herber, Carolin S. Jasper, Janine Lenk, Lutz E. Pillunat

    Purpose: To investigate the efficacy of adjunctive selective laser trabeculoplasty (SLT) in reducing 24-h intraocular pressure (IOP) fluctuations and nocturnal IOP peaks. Methods: In this prospective interventional case series, 157 medically treated eyes of 157 patients with primary open-angle glaucoma (POAG) who were assigned SLT to further reduce IOP were consecutively included. Each patient had a complete glaucoma work-up and 24-h IOP monitoring (6 measurements, including one in the supine position) taken before and on average 6 months after SLT. The main outcome measures were the reduction of 24-h IOP fluctuations and nocturnal peak IOP. Secondary outcome measures were success rates, factors influencing the reduction of high 24-h IOP fluctuations and nocturnal peak IOP, complications, and severe adverse events. Results: Medicated mean 24-h IOP (mmHg) was statistically significantly reduced from 15.1 ± 2.6 to 13.8 ± 2.4 (P < 0.001) and IOP fluctuations from 6.5 ± 2.7 to 5.4 ± 2.6 (P < 0.001) 6 months after SLT. Ninety-four eyes (59.9%) initially had high IOP fluctuations (more than 5 mmHg). These were reduced from 8.1 ± 2.3 to 5.6 ± 2.7 at 6 months (P < 0.001). Fifty-two eyes (55.3%) had fluctuations below 5 mmHg post-SLT which was defined as success. Fifty-one patients (32.5%) had nocturnal IOP peaks. In these cases, nocturnal IOP was reduced by 19.2% from 20.1 ± 3.4 to 16.2 ± 3.3 mmHg at 6 months (P = 0.001). Conclusions: The current study demonstrates that adjunctive SLT not only reduces mean 24-h IOP in treated POAG patients, but also has an additional benefit in reducing IOP fluctuations and nocturnal peak IOP. Trial registration: Clinical trial registration: NCT02959242.