SRSebastien Racinais

Sebastien Racinais

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastien Racinais has a total of 400 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • International Expert Consensus on Warm-Up Protocols for Athletes: A Delphi Study

    by Daniel Boullosa, Marina Gil-Calvo, Anthi Xenofondos, Dimitris A. Patikas, Anthony J. Blazevich, José Afonso, Irineu Loturco, David Behm, Kai Xu, Nicolas Babault, et al.

    Purpose : To present the first international consensus on warm-up in sport. Methods : Twenty-three experts from 12 countries worldwide participated in a 3-round Delphi process, including an online open asynchronous discussion. A total of 122 initial statements were evaluated across 4 domains: (1) definitions and nomenclature; (2) objectives and structure; (3) exercises, performance enhancement, and mechanisms; and (4) health and injury prevention. Results : Consensus (≥80% agreement) was achieved for 72 statements (60%). The panel defined the warm-up as a structured and purposeful preparatory intervention aimed at optimizing physiological responses and readiness in both training and competitive settings with a combination of both active and passive strategies. Experts identified a 3-layer model comprising general and specific exercises and conditioning activities, with the latter being voluntary contractions of sufficient volume and intensity to induce postactivation performance enhancement. Athletes’ readiness and fatigue can be monitored during warm-up protocols with different tools. The comprehensiveness of a warm-up protocol is a key factor associated with its effectiveness. Warm-ups were recognized as context- and sport-dependent, integrating diverse goals depending on the sport’s contextual factors and individual characteristics. While inclusion of some type of exercises in the warm-up may reduce long-term injury risk, as in other periods of the training session, there is no support for acute injury protection. Conclusion : This consensus confirms that warm-ups are structured, multifactorial interventions integrating active and passive components to enhance readiness for training and competition. This framework serves to inform research design and effective evidence-informed warm-up strategies across sports disciplines.


  • No differences between cold and hot water immersion for neuromuscular recovery, sprint mechanics and delayed onset muscle soreness after a simulated football game

    by David Bandiera, Hervé Di Domenico, Pierre Samozino, Sébastien Racinais, Thomas Rupp

    Football players typically cover approximately 10 km during a match, interspersed with frequent transitions between low-to-moderate and high-intensity efforts (Bengtsson et al., 2013). From a techn...

  • Open Access

    Expert consensus on passive heating interventions to promote skeletal muscle strength and mass: a delphi study

    by Elisa Lemos, Ian B. Stewart, Patrick Rodrigues, Shawnda A. Morrison, Lee Wharton, Christopher J. Tyler, Stephen S. Cheung, Sebastian Racinais, Ralph J. F. H. Gordon, Alex Lloyd, et al.

    Purpose: Passive heating has emerged as a potential non‑exercise method to support muscle strength and mass, but its application is limited by inconsistent protocols and unclear dosage and safety guidelines. This study used a Delphi methodology to establish expert consensus on key parameters for passive heating interventions targeting neuromuscular and muscle morphology outcomes. Methods: An international panel of academic experts (≥ 3 peer‑reviewed publications in passive heating and neuromuscular function) completed a two‑round Delphi process. Round 1 gathered open‑ended responses on passive heating strategies, intervention targets, and safety. In Round 2, experts ranked the importance of generated statements. Consensus was defined as ≥ 70% ranking a statement as either first or second in importance. Results: Eleven experts completed Round 1 and ten in Round 2. From 177 qualitative responses, 130 statements were evaluated, with 11 reaching consensus (80–100% agreement; interquartile range = 0–1). Hot‑water immersion was prioritised as the most optimal passive heating modality. Experts agreed on targeting muscle temperatures of 39–40 °C, ~ 60-minute session durations, and once‑daily exposure as key intervention parameters. Strong consensus was also reached for monitoring core temperature and cardiovascular strain (e.g., heart rate, blood pressure) to ensure participant safety. No consensus was reached on a single target population or the total intervention duration. Conclusion: This Delphi study provides a consensus‑based framework outlining key parameters and safety considerations for passive heating interventions. These findings do not establish efficacy but identify priority variables to inform future experimental research and cautious translation into applied and clinical contexts.


  • What do thermal indices lack to help predict heat-related risk in elite Athletics?

    by David Bandiera, Frédéric Garrandes, Jan Kowalski, Paolo Emilio Adami, Sebastien Racinais, Andreas Matzarakis, Yannis P Pitsiladis, Antonio Tessitore, Stéphane Bermon

    Objectives: This study aimed to characterise the frequency of exertional heat stroke (EHS), did-not-finish (DNF) and medical encounter (MED) outcomes in elite Athletics competitions, and to evaluate their association with environmental, individual and race-related variables. Particular attention was given to the wet bulb globe temperature (WBGT), a thermal index widely used by international federations to estimate athlete heat strain. Methods: Data were collected from 4938 athletes of both sexes participating in 80 World Athletics races held between 2019 and 2024 in five disciplines: long distance track events, marathon, racewalking, cross-country and trail-running. Spearman rank coefficient correlations, Pearson χ 2 tests and negative binomial (NB) regressions were used to explore associations between outcomes (EHS, DNF, MED) and environmental, individual and race-related variables. The predictive ability of these variables was assessed using leave-one-out cross-validation to identify the best-performing univariable and multivariable models. Results: EHS frequency was 8/1000 on average and 16/1000 when the WBGT was above 28.0°C, independent of sex (p=0.297) or discipline (p=0.980). DNF and MED were higher in marathon, racewalking and trail-running than shorter disciplines (p<0.001). Among variables, the mean radiant temperature showed the strongest univariable association with EHS (R²=0.11, p<0.001), while WBGT association was weaker (R²=0.04, p=0.018). Predictive accuracy was limited, with the best model having an error of 0.5±0.7 EHS per race. Conclusion: The risk of EHS is particularly high during elite endurance events in Athletics. While EHS was greater with higher WBGT and radiant temperatures, neither provided sufficient predictive accuracy for heat-related risk in elite endurance athletes. Future models should consider other factors such as heat acclimatisation and recent illness to enhance predictive ability.


  • Open Access

    Impact of heat exposure during immobilization‐induced de‐training and re‐training on aerobic capacity and haemoglobin mass

    by Scott Cocking, Nathan Townsend, Mariem Labidi, Khouloud Mtibaa, Marine Alhammoud, Nada Nasir, Nelda Nader, Karim Khalladi, Claire Tourny, Abdulaziz Farooq, et al.

    The aim of this work was to assess the effect of heat exposure on cardiorespiratory and haematological responses during de‐training and re‐training. Nineteen men (33.8 ± 2.7 years; 182 ± 5.7 cm, 84.4 ± 9.3 kg) completed 4 weeks of pre‐training followed by heat exposure (HEAT; n  = 9) or control (CON; n = 10). Both groups then de‐trained for 2 weeks with lower‐limb immobilization followed by 2 weeks of re‐training. Cardiorespiratory fitness and total haemoglobin mass (Hb mass ) were measured at baseline (BASE), prior to (IMMO pre ) and following (IMMO post ) immobilization and after a ‘return‐to‐sport’ (RTS post ) training phase. Compared with IMMO pre , at the gas exchange threshold (GET) was reduced ( d  = −0.53; P  < 0.005) at IMMO post , whereas maximal oxygen uptake () did not change significantly ( d  = 0.14; P = 0.07). The reduction in GET was more pronounced for HEAT than CON ( d  = −0.77; P = 0.001). At IMMO post , GET and peak power output were lower than IMMO pre ( d  = −1.4, P  < 0.005 and d  = 0.43, P  = 0.01, respectively), however there was no difference between groups. At RTS post , the at GET increased again in both groups yet remained lower than IMMO pre although the reduction in HEAT ( d  = −0.42; P = 0.43) was less than CON ( d  = −0.8; P  = 0.05). At RTS post , HEAT fully recovered GET power losses compared to IMMO post ( d  = 1.1; P  = 0.001), while CON only showed a trivial change ( d  = 0.07; P  = 0.1). No significant changes were observed in Hb mass , haematocrit or plasma volume throughout the study ( P ≥ 0.763). Heat exposure did not attenuate a decline in cardiorespiratory fitness during immobilization‐induced de‐training, but could potentiate its recovery upon re‐commencement of training.

  • Occupational heat risk at the 2026 FIFA World Cup: implications for worker safety

    by Andrew Grundstein, Margaret Morrissey-Basler, Rebecca Stearns, Sebastien Racinais

    The 2026 FIFA World Cup will be held in 16 cities across the United States, Mexico, and Canada, exposing tens of thousands of workers to varying occupational heat stress in June–July. While prior research largely examined risks to players and spectators, this study evaluates heat exposure among the workforce. Using 30 years (1991–2020) of hourly meteorological data, we calculated wet-bulb globe temperatures (WBGTs) and assessed exceedance of National Institute for Occupational Safety and Health recommended exposure limits (REL) and recommended alert limits (RAL) across multiple activity levels and work/rest schedules. Results show inter-city variation. Hot, humid locations such as Houston, Miami, and Monterrey often reach maximum WBGTs near 31 °C, frequently exceeding safety thresholds, particularly for higher workloads and longer shifts. Cooler cities like Seattle and San Francisco usually have maximum WBGTs below 20 °C and remain under thresholds in typical conditions but face acute hazards during extreme events, such as the 2021 Pacific Northwest heat wave when WBGTs exceeded 32 °C. Shading reduces heat stress by lowering peak WBGTs by ∼2–3 °C and substantially decreasing RAL and REL exceedance frequencies. Acclimatization further influences risk, as lower RAL thresholds for unacclimatized workers result in more frequent and prolonged exceedances across all work intensities and rest schedules compared with acclimatized workers. These findings highlight the need for venue-specific heat management plans reflecting local climate, workload, and rest patterns. Given varied protections, FIFA and host cities should adopt evidence-based measures such as flexible scheduling, hydration and cooling access, and acclimatization protocols, along with contingency plans for rare extreme heat waves.


  • Validation of the iButton and Flex sensors for measuring skin temperature

    by David Bandiera, Jean de Bardonnèche, Philippe Janry, Sylvie Calas-Étienne, Jean-Christophe Aubin, Antonio Tessitore, Yannis Pitsiladis, Sébastien Racinais

    Purpose Skin temperature is a critical component of athletes’ heat strain during exercise in the heat. This study evaluated the innovative Flex sensor (BodyCap, Caen, France), allowing real-time measurements, against a data logger (iButton hygrochron DS1923, Analog Devices, Wilmington, USA), commonly used in sports science. Methods In a first study, the accuracies of iButton faces as well as the Flex sensor were tested on a constant-temperature Peltier module affixed to a brass plate. In a second study, concurrent skin temperature measurements were conducted with both sensors on eight participants cycling in hot conditions. Results Both faces of the iButton underestimated plate temperature, with the base (ME = mean error: 0.59 ± 0.25 °C at 30 °C, 1.62 ± 0.48 °C at 40 °C) being significantly more accurate than the top (ME: 1.14 ± 0.26 °C at 30 °C, 3.02 ± 0.71 °C at 40 °C, p < 0.001). The rate of temperature increase of the base was also higher than the top at 30 °C (1.97 ± 0.16 °C/min vs 1.49 ± 0.15 °C/min) and 40 °C (4.41 ± 0.46 °C/min vs 3.14 ± 0.16 °C/min, both p < 0.001). The Flex sensor underestimated plate temperature (ME: 1.31 ± 0.32 °C at 30 °C, 3.00 ± 0.84 °C at 40 °C), showing larger errors than the iButton base (p < 0.001). During exercise, the Flex sensor (36.91 ± 1.19 °C) measured higher skin temperature compared to the iButton (36.50 ± 1.15 °C), with an ME of -0.41 ± 0.55 °C. Conclusion In the absence of a gold standard, for scenarios where real-time monitoring is not required, using the iButton with its base applied to the skin is therefore recommended. To enhance the Flex sensor’s accuracy, implementing a calibration protocol before use is strongly suggested, enabling its full potential for real-time monitoring.


  • Statistical Parametric Mapping Analysis of Muscle-Oxygenation Kinetics in Response to Repeated-Sprint Training in Hypoxia

    by Clint Hansen, Franck Brocherie, Sébastien Racinais, Nathan Townsend, Scott Cocking, Anthony Couderc, Julien Piscione, Olivier Girard

    Purpose: To examine the effect of repeated-sprint training in hypoxia (RSH) on oxygenation kinetics in the vastus lateralis muscle using statistical parametric mapping during repeated treadmill sprints in world-class female Rugby Sevens players. Methods: All players performed 4 repeated-sprint cycle-training sessions in either normobaric hypoxia (RSH, exercise, and interset rest at inspired oxygen fraction of 10.6% and 20.9%, respectively; n = 12) or normoxia (n = 11) during a 9-day training camp before international competition. Repeated-sprint ability (8 × 5-s treadmill sprints with 25-s recovery) was assessed preintervention and postintervention in normoxia only. Continuous assessment of tissue saturation index (TSI) in the vastus lateralis muscle was conducted using near-infrared spectroscopy. Results: There was a difference in TSI signal amplitude between conditions during the last second of the 5-second sprint phase and the first 3.7 seconds of the 25-second recovery phase. In the RSH group, TSI magnitude during the sprints and recovery phases was lower after compared with before the intervention (from 4.3 to 8.7 s; P < .001). The cumulated distance covered in sprints 1 to 8 significantly increased from preintervention to postintervention (pooled values: +1.9% [3.0]%; P = .019), regardless of the condition (P = .149). Conclusion: Statistical parametric mapping analysis revealed a noticeable change in TSI in the RSH group toward the end of both the active and the early recovery phase of a normoxic repeated-treadmill-sprints test, whereas no differences were detected in the normoxic group postintervention. Despite improvements in repeated-sprint ability in both groups, addition of severe hypoxia during repeated-sprint training did not yield further performance enhancement.

  • Open Access

    Muscle regeneration is improved by hot water immersion but unchanged by cold following a simulated musculoskeletal injury in humans

    by Valentin Dablainville, Adèle Mornas, Tom Normand‐Gravier, Maha Al‐Mulla, Emmanouil Papakostas, Bruno Olory, Theodorakys Marin Fermin, Frantzeska Zampeli, Nelda Nader, Marine Alhammoud, et al.

    Cryotherapy is a popular strategy for the treatment of skeletal muscle injuries. However, its effect on post‐injury human muscle regeneration remains unclear. In contrast, promising results recently emerged using heat therapy to facilitate recovery from muscle injury. This study aimed to examine the effect of three different thermal treatments on muscle recovery and regeneration following a simulated injury in humans. Thirty‐four participants underwent a muscle damage protocol induced by electrically stimulated eccentric contractions triggering regenerative processes following myofibre necrosis. Thereafter, participants were exposed to daily lower body water immersion for 10 days in cold (CWI, 15 min at 12°C), thermoneutral (TWI, 30 min at 32°C) or hot water immersion (HWI, 60 min at 42°C). Muscle biopsies were sampled before and at +5 (D5) and +11 (D11) days post‐damage. None of the water immersions differed in recovery of force‐generating capacity ( P = 0.108). HWI induced a lower perceived muscle pain than TWI ( P = 0.035) and lower levels of circulating creatine kinase ( P ≤ 0.012) and myoglobin ( P < 0.001) than TWI and CWI. Contrary to our hypothesis, CWI did not improve perceived muscle pain or reduce circulating markers of muscle damage ( P ≥ 0.207). Expression of heat shock proteins 27 and 70 was significantly increased in HWI ( P < 0.038) at D11 and appeared blunted using CWI. Furthermore, nuclear factor‐κB expression significantly increased in all conditions except HWI, while interleukin‐10 was upregulated only in HWI at D11 ( P = 0.014). In conclusion, our results support the use of HWI but not cold, to improve muscle regeneration following an injury. image Key points: Cryotherapy and heat therapy are popular strategies in the treatment of skeletal muscle injury; however, existing literature is equivocal, and their effects on human muscle regeneration remain unknown. We investigated the effect of three thermal treatments (cold water immersion (CWI): 15 min at 12°C; thermoneutral water immersion (TWI): 30 min at 32°C; or hot water immersion (HWI): 60 min at 42°C) performed daily for 10 days following electrically stimulated eccentric muscle damage inducing regenerative mechanisms. CWI did not improve chronic perceived muscle pain nor reduce circulating markers of muscle damage. HWI limited chronic perceived pain and circulating markers of muscle damage, potentially influenced inflammatory mechanisms, and increased the expression of heat shock proteins. HWI appears more beneficial than CWI in improving muscle regeneration after a muscle injury.