Olivia Kalmanson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olivia Kalmanson has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Samuel P. Gubbels
Department of Otolaryngology–Head and Neck Surgery, The University of Colorado School of Medicine, Aurora
3 shared publications- Carol A. Foster
Department of Otolaryngology, University of Colorado Anschutz School of Medicine, Aurora, CO 80045, USA
2 shared publications Jennifer Drohosky
Department of Audiology Children's Hospital Colorado Aurora Colorado USA
2 shared publications- Kenny H. Chan
Department of Otolaryngology University of Colorado School of Medicine Aurora Colorado USA
2 shared publications Laura Greaver
Department of Audiology Children's Hospital Colorado Aurora Colorado USA
2 shared publications- Nathan D. Cass
Department of Otolaryngology University of Kentucky Lexington Kentucky USA
2 shared publications
Latest Publications
- 16 November 2026
- Published by Wiley in The Laryngoscope
In Response to Unilateral Sensorineural Hearing Loss in Children: Natural History and Clinical Characteristics
- 16 November 2026
- Published by Wiley in The Laryngoscope
In Response to Unilateral Sensorineural Hearing Loss in Children: Natural History and Clinical Characteristics
- 6 May 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (10) , 3914-3922
Unilateral Sensorineural Hearing Loss in Children: Natural History and Clinical Characteristics
Objective: Characterize hearing outcomes and etiologies of congenital and postnatal unilateral sensorineural hearing loss (SNHL).Methods: Reviewed charts of children with unilateral SNHL, 2003–2019. Primary outcomes were changes in pure tone average (PTA) of affected and contralateral ears. Patients who failed a newborn hearing screen (NBHS) were considered ‘congenital’ onset, those who passed “postnatal,” and those without “unknown.” Demographics, infectious/genetic workup, audiograms, imaging, and hearing aid use were collected.Results: A total of 1264 charts reviewed, 476 subjects included: 156 congenital, 252 postnatal, and 68 unknown onset. The mean (SD) of the first PTA was 53.8(29.4) dB for affected and 10.6(5.8) dB for unaffected ears. Thirty‐nine percent followed up > 5 years. Change in PTA over time was 3.0(14.5) dB for affected and −1.7(7.4) dB for unaffected ears. The congenital subgroup had poorer hearing in the affected ear at the first audiogram (p < 0.0001) and was more likely to have progressive hearing loss (p = 0.0040) than the postnatal subgroup. Imaging in 296 patients revealed ipsilateral abnormalities in 26.6% of CTs and 39.6% of MRIs. Absent/hypoplastic cochlear nerve was the most common abnormal and was associated with poorer hearing than those with normal nerves (p < 0.0001). Enlarged vestibular aqueduct was not associated with progression of hearing loss.Conclusion: Hearing in both the affected and contralateral ears remained stable after the first audiogram in > 80% of patients. Patients with congenital loss had poorer hearing at diagnosis and were more likely to have progression than those with postnatal loss. MRI was more sensitive than CT in detecting an anatomic cause of SNHL, and absent/hypoplastic cochlear nerve was the most common finding.Level of Evidence: 4.
- 6 May 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (10) , 3914-3922
Unilateral Sensorineural Hearing Loss in Children: Natural History and Clinical Characteristics
Objective: Characterize hearing outcomes and etiologies of congenital and postnatal unilateral sensorineural hearing loss (SNHL).Methods: Reviewed charts of children with unilateral SNHL, 2003–2019. Primary outcomes were changes in pure tone average (PTA) of affected and contralateral ears. Patients who failed a newborn hearing screen (NBHS) were considered ‘congenital’ onset, those who passed “postnatal,” and those without “unknown.” Demographics, infectious/genetic workup, audiograms, imaging, and hearing aid use were collected.Results: A total of 1264 charts reviewed, 476 subjects included: 156 congenital, 252 postnatal, and 68 unknown onset. The mean (SD) of the first PTA was 53.8(29.4) dB for affected and 10.6(5.8) dB for unaffected ears. Thirty‐nine percent followed up > 5 years. Change in PTA over time was 3.0(14.5) dB for affected and −1.7(7.4) dB for unaffected ears. The congenital subgroup had poorer hearing in the affected ear at the first audiogram (p < 0.0001) and was more likely to have progressive hearing loss (p = 0.0040) than the postnatal subgroup. Imaging in 296 patients revealed ipsilateral abnormalities in 26.6% of CTs and 39.6% of MRIs. Absent/hypoplastic cochlear nerve was the most common abnormal and was associated with poorer hearing than those with normal nerves (p < 0.0001). Enlarged vestibular aqueduct was not associated with progression of hearing loss.Conclusion: Hearing in both the affected and contralateral ears remained stable after the first audiogram in > 80% of patients. Patients with congenital loss had poorer hearing at diagnosis and were more likely to have progression than those with postnatal loss. MRI was more sensitive than CT in detecting an anatomic cause of SNHL, and absent/hypoplastic cochlear nerve was the most common finding.Level of Evidence: 4.
- Open Access
- 7 March 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (2) , 25
Epley’s Influence on Horizontal Canal BPPV Variants
Dr. Epley has been instrumental in defining the mechanisms and treatment of BPPV variants, including those of the horizontal canals. Cupulolithiasis is a horizontal canal BPPV variant usually defined as direction-changing apogeotropic nystagmus. In recent years, the favored cupulolithiasis mechanism of otoconia adhering persistently to the cupula has been called into question. Epley was the first to propose mechanistic theories which better match the most recent evidence. From the beginning, he has demonstrated mastery over the semicircular canal pathology and otoconial mechanics.
- 7 March 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (2) , 25
Open AccessEpley’s Influence on Horizontal Canal BPPV Variants
Dr. Epley has been instrumental in defining the mechanisms and treatment of BPPV variants, including those of the horizontal canals. Cupulolithiasis is a horizontal canal BPPV variant usually defined as direction-changing apogeotropic nystagmus. In recent years, the favored cupulolithiasis mechanism of otoconia adhering persistently to the cupula has been called into question. Epley was the first to propose mechanistic theories which better match the most recent evidence. From the beginning, he has demonstrated mastery over the semicircular canal pathology and otoconial mechanics.
- 16 July 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (8) , e595-e601
Factors Affecting Speech Discrimination After Vestibular Schwannoma Resection
Objective: Investigate the relationship between word recognition score (WRS) and pure tone average (PTA) after hearing preservation surgery for vestibular schwannomas (VS) as well as evaluate the consistency of hearing classification systems. Study Design: A retrospective chart review was performed. Setting: This study included patients from a single academic tertiary referral hospital. Patients: Patients with VS and serviceable hearing who underwent hearing preservation surgery 2014–2023. Patients excluded for neurofibromatosis 2 and lacking pre/postop audiograms. Intervention(s): All patients underwent resection of vestibular schwannoma. Main Outcome Measure(s): Pre/postop WRS, PTA, and AAO-HNS, Gardner-Robertson (GR), and WRS Class (WRSC) hearing classifications. Results: Seventy-five patients were included. Average preop and postop PTA and WRS were 26 ± 12 dB, 79 ± 39 dB, 92 ± 12%, and 33 ± 43%, respectively. Postop PTAs were distributed along the complete testable decibel range, while the postop WRS displayed a bimodal distribution, with WRS >50% or p = 0.005). With increasing Koos grades, intraop ABRs were significantly more likely to exhibit changes (p = 0.005). AAO-HNS and GR classified patients nearly identically, while the WRSC resulted in more class I and fewer class II. The cutoff of serviceable hearing was comparable across all classification systems. Conclusions: Effects on the brainstem component of Koos 3–4 tumors may particularly disturb speech processing. This effect seems amplified by surgical dissection. AAO-HNS, GR, and WRSC hearing classifications are comparable in describing serviceable hearing in vestibular schwannoma patients.
- 16 July 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (8) , e595-e601
Factors Affecting Speech Discrimination After Vestibular Schwannoma Resection
Objective: Investigate the relationship between word recognition score (WRS) and pure tone average (PTA) after hearing preservation surgery for vestibular schwannomas (VS) as well as evaluate the consistency of hearing classification systems. Study Design: A retrospective chart review was performed. Setting: This study included patients from a single academic tertiary referral hospital. Patients: Patients with VS and serviceable hearing who underwent hearing preservation surgery 2014–2023. Patients excluded for neurofibromatosis 2 and lacking pre/postop audiograms. Intervention(s): All patients underwent resection of vestibular schwannoma. Main Outcome Measure(s): Pre/postop WRS, PTA, and AAO-HNS, Gardner-Robertson (GR), and WRS Class (WRSC) hearing classifications. Results: Seventy-five patients were included. Average preop and postop PTA and WRS were 26 ± 12 dB, 79 ± 39 dB, 92 ± 12%, and 33 ± 43%, respectively. Postop PTAs were distributed along the complete testable decibel range, while the postop WRS displayed a bimodal distribution, with WRS >50% or p = 0.005). With increasing Koos grades, intraop ABRs were significantly more likely to exhibit changes (p = 0.005). AAO-HNS and GR classified patients nearly identically, while the WRSC resulted in more class I and fewer class II. The cutoff of serviceable hearing was comparable across all classification systems. Conclusions: Effects on the brainstem component of Koos 3–4 tumors may particularly disturb speech processing. This effect seems amplified by surgical dissection. AAO-HNS, GR, and WRSC hearing classifications are comparable in describing serviceable hearing in vestibular schwannoma patients.
- 23 January 2024
- Published by Elsevier in Hearing Research
- Vol. 443, 108962
Nestin-expressing cells are mitotically active in the mammalian inner ear
- 23 January 2024
- Published by Elsevier in Hearing Research
- Vol. 443, 108962
Nestin-expressing cells are mitotically active in the mammalian inner ear
- 6 July 2023
- Published by Elsevier in American Journal of Otolaryngology
- Vol. 44 (6) , 103986
Pediatric cholesteatoma associated with congenital aural atresia and stenosis
- 6 July 2023
- Published by Elsevier in American Journal of Otolaryngology
- Vol. 44 (6) , 103986
Pediatric cholesteatoma associated with congenital aural atresia and stenosis
- Open Access
Rare Coding Variants in Patients with Non-Syndromic Vestibular Dysfunction
Vertigo due to vestibular dysfunction is rare in children. The elucidation of its etiology will improve clinical management and the quality of life of patients. Genes for vestibular dysfunction were previously identified in patients with both hearing loss and vertigo. This study aimed to identify rare, coding variants in children with peripheral vertigo but no hearing loss, and in patients with potentially overlapping phenotypes, namely, Meniere’s disease or idiopathic scoliosis. Rare variants were selected from the exome sequence data of 5 American children with vertigo, 226 Spanish patients with Meniere’s disease, and 38 European–American probands with scoliosis. In children with vertigo, 17 variants were found in 15 genes involved in migraine, musculoskeletal phenotypes, and vestibular development. Three genes, OTOP1, HMX3, and LAMA2, have knockout mouse models for vestibular dysfunction. Moreover, HMX3 and LAMA2 were expressed in human vestibular tissues. Rare variants within ECM1, OTOP1, and OTOP2 were each identified in three adult patients with Meniere’s disease. Additionally, an OTOP1 variant was identified in 11 adolescents with lateral semicircular canal asymmetry, 10 of whom have scoliosis. We hypothesize that peripheral vestibular dysfunction in children may be due to multiple rare variants within genes that are involved in the inner ear structure, migraine, and musculoskeletal disease.
Open AccessRare Coding Variants in Patients with Non-Syndromic Vestibular Dysfunction
Vertigo due to vestibular dysfunction is rare in children. The elucidation of its etiology will improve clinical management and the quality of life of patients. Genes for vestibular dysfunction were previously identified in patients with both hearing loss and vertigo. This study aimed to identify rare, coding variants in children with peripheral vertigo but no hearing loss, and in patients with potentially overlapping phenotypes, namely, Meniere’s disease or idiopathic scoliosis. Rare variants were selected from the exome sequence data of 5 American children with vertigo, 226 Spanish patients with Meniere’s disease, and 38 European–American probands with scoliosis. In children with vertigo, 17 variants were found in 15 genes involved in migraine, musculoskeletal phenotypes, and vestibular development. Three genes, OTOP1, HMX3, and LAMA2, have knockout mouse models for vestibular dysfunction. Moreover, HMX3 and LAMA2 were expressed in human vestibular tissues. Rare variants within ECM1, OTOP1, and OTOP2 were each identified in three adult patients with Meniere’s disease. Additionally, an OTOP1 variant was identified in 11 adolescents with lateral semicircular canal asymmetry, 10 of whom have scoliosis. We hypothesize that peripheral vestibular dysfunction in children may be due to multiple rare variants within genes that are involved in the inner ear structure, migraine, and musculoskeletal disease.
- 1 February 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (2) , e73-e80
Effect of Head Position and Magnetic Resonance Sequence on Cochlear Implant–Related Artifact Size and Internal Auditory Canal Visibility
Hypothesis: To assess whether cochlear implant (CI)–related magnetic resonance imaging (MRI) artifact and visibility of the internal auditory canal (IAC) can be improved with head positioning and select MRI sequences. Background: CI-related MRI artifact limits the use of CIs in otherwise good candidates because of the need for serial MRIs for monitoring of pathology. This most notably impacts patients with tumors of the cerebellopontine angle and IAC. Methods: Two cadaver heads were implanted with either a Med-El CONCERT (fixed magnet) or SYNCHRONY (rotating magnet) device. Each head was imaged in a 1.5T scanner in 11 different positions. The SYNCHRONY-implanted head was also imaged in a 3.0T scanner in seven positions. Artifact size and IAC visibility (graded on a Likert scale) were measured for each head position by a neuroradiologist. Results: The CONCERT CI produced significantly smaller artifact than the SYNCHRONY CI (effect size, 14.65 mm; p < 0.001). There was no significant difference between CI models in regard to IAC visibility. No head positions were statistically significantly better than neutral position for minimizing artifact size or IAC visibility, although some positions resulted in significantly larger artifact (effect sizes, 2.1–14.3 mm; p < 0.05) or significantly poorer IAC visibility (effect size, 1.4; p < 0.01). The T2 three-dimensional (CISS/FIESTA) sequence demonstrated significantly smaller artifact than T1 sequences, whereas T1 sequences demonstrated significantly better IAC visibility than T2 sequences. Conclusion: Head positioning and magnetic resonance sequence selection impact CI-related artifact size and IAC visibility.
- 1 February 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (2) , e73-e80
Effect of Head Position and Magnetic Resonance Sequence on Cochlear Implant–Related Artifact Size and Internal Auditory Canal Visibility
Hypothesis: To assess whether cochlear implant (CI)–related magnetic resonance imaging (MRI) artifact and visibility of the internal auditory canal (IAC) can be improved with head positioning and select MRI sequences. Background: CI-related MRI artifact limits the use of CIs in otherwise good candidates because of the need for serial MRIs for monitoring of pathology. This most notably impacts patients with tumors of the cerebellopontine angle and IAC. Methods: Two cadaver heads were implanted with either a Med-El CONCERT (fixed magnet) or SYNCHRONY (rotating magnet) device. Each head was imaged in a 1.5T scanner in 11 different positions. The SYNCHRONY-implanted head was also imaged in a 3.0T scanner in seven positions. Artifact size and IAC visibility (graded on a Likert scale) were measured for each head position by a neuroradiologist. Results: The CONCERT CI produced significantly smaller artifact than the SYNCHRONY CI (effect size, 14.65 mm; p < 0.001). There was no significant difference between CI models in regard to IAC visibility. No head positions were statistically significantly better than neutral position for minimizing artifact size or IAC visibility, although some positions resulted in significantly larger artifact (effect sizes, 2.1–14.3 mm; p < 0.05) or significantly poorer IAC visibility (effect size, 1.4; p < 0.01). The T2 three-dimensional (CISS/FIESTA) sequence demonstrated significantly smaller artifact than T1 sequences, whereas T1 sequences demonstrated significantly better IAC visibility than T2 sequences. Conclusion: Head positioning and magnetic resonance sequence selection impact CI-related artifact size and IAC visibility.
- Open Access
Cupulolithiasis: A Critical Reappraisal
Objective: To review the history and pathophysiologic theories for cupulolithiasis and canalith jam in benign paroxysmal positional vertigo.Data Sources: PubMed, Google Scholar.Review Methods: Three PubMed and Google Scholar searches were performed, keywords: “cupulolithiasis,” “apogeotropic [and] benign,” and “canalith jam,” resulting in 187 unique full‐text articles in English or with English translation. Figures—Labyrinthine photographs were obtained of fresh utricles, ampullae, and cupulae of a 37‐day‐old mouse.Conclusions: Freely moving otoconial masses explain most cases (>98%) of benign paroxysmal positional vertigo. Evidence that otoconia adhere strongly or persistently to the cupula is lacking. Apogeotropic nystagmus in the horizontal canal form is often attributed to cupulolithiasis; however, periampullary canalithiasis explains self‐limited nystagmus, and reversible canalith jam explains prolonged apogeotropic nystagmus. Treatment‐resistant cases can be explained by entrapment of particles in the canals or ampullae, but persistent adherence to the cupula remains theoretical.Implications for Practice: Apogeotropic nystagmus is usually due to freely moving particles and should not be used in studies of horizontal canal benign paroxysmal positional vertigo as the sole method to define entrapment or cupulolithiasis. Caloric testing and imaging may help differentiate jam from cupulolithiasis. Treatment for apogeotropic benign paroxysmal positional vertigo should include maneuvers that rotate the head through 270° to fully clear the canal of mobile particles, using mastoid vibration or head shaking if entrapment is suspected. Canal plugging can be used for treatment failures.
Open AccessCupulolithiasis: A Critical Reappraisal
Objective: To review the history and pathophysiologic theories for cupulolithiasis and canalith jam in benign paroxysmal positional vertigo.Data Sources: PubMed, Google Scholar.Review Methods: Three PubMed and Google Scholar searches were performed, keywords: “cupulolithiasis,” “apogeotropic [and] benign,” and “canalith jam,” resulting in 187 unique full‐text articles in English or with English translation. Figures—Labyrinthine photographs were obtained of fresh utricles, ampullae, and cupulae of a 37‐day‐old mouse.Conclusions: Freely moving otoconial masses explain most cases (>98%) of benign paroxysmal positional vertigo. Evidence that otoconia adhere strongly or persistently to the cupula is lacking. Apogeotropic nystagmus in the horizontal canal form is often attributed to cupulolithiasis; however, periampullary canalithiasis explains self‐limited nystagmus, and reversible canalith jam explains prolonged apogeotropic nystagmus. Treatment‐resistant cases can be explained by entrapment of particles in the canals or ampullae, but persistent adherence to the cupula remains theoretical.Implications for Practice: Apogeotropic nystagmus is usually due to freely moving particles and should not be used in studies of horizontal canal benign paroxysmal positional vertigo as the sole method to define entrapment or cupulolithiasis. Caloric testing and imaging may help differentiate jam from cupulolithiasis. Treatment for apogeotropic benign paroxysmal positional vertigo should include maneuvers that rotate the head through 270° to fully clear the canal of mobile particles, using mastoid vibration or head shaking if entrapment is suspected. Canal plugging can be used for treatment failures.