STSimoni Triantafyllidou

Simoni Triantafyllidou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simoni Triantafyllidou has a total of 58 co-authors. Here are the top co-authors by number of shared publications:

  • Darren A. Lytle

    Office of Research and Development (ORD), U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, Ohio 45268, United States

    7 shared publications
  • Marc Edwards

    7 shared publications
  • Marc A. Edwards

    Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States

    5 shared publications
  • Casey Formal

    U.S. Environmental Protect Agency, Region 5, Groundwater and Drinking Water Branch, 77 W. Jackson Blvd., Chicago, IL, United States

    3 shared publications
  • Christy Muhlen

    U.S. Environmental Protect Agency, Office of Research and Development, Drinking Water Management Branch, Center for Environmental Solutions & Emergency Response, Water Infrastructure Division, 26 W. Martin Luther King Dr., Cincinnati, OH 45268, United States

    3 shared publications
  • Evelyne Doré

    NSERC Industrial Chair on Drinking Water, Department of Civil, Mining and Geological Engineering, Polytechnique Montréal, Montréal, QC, Canada

    3 shared publications

Latest Publications

  • Open Access

    Review of historical plumbing codes for lead service line inventories in the United States

    by Christina Devine, Luis Garcia-Bakarich, William Platten, Krista Jajeh, Simoni Triantafyllidou

    Inventorying and replacing lead service lines (LSLs) is a national priority in the United States (US), with records review conducted as a first step. Among other records, historical plumbing codes can provide cutoff dates for LSL allowance in the US. This work identified and reviewed historical national plumbing codes for mention of lead for drinking water pipe and found that lead pipe was permissible for service lines by the Basic Plumbing Code until 1978, the Uniform Plumbing Code until 1988, and the Southern Standard Plumbing Code until 1977/78. Overall, identifying pertinent code titles over time and obtaining them was challenging because those records were not readily available. Once obtained, interpreting the code language also proved challenging. Terminology initially reflected sanitary systems before drinking water systems were incorporated, and code editions through the years reorganized the content and specific mentions of lead in service lines within text. This review focused on model plumbing codes, which are then adopted at the state or local level, typically with modifications that also need to be understood. Two practical examples of service line inventory development were also summarized. These examples highlighted placing different emphasis on plumbing code review.


  • Lead in synthetic and municipal drinking water varies by field versus laboratory analysis

    by Simoni Triantafyllidou, Lauren Wasserstrom, James Nelson, Dawn Webb, Casey Formal, Evelyne Doré, Darren Lytle


  • A literature review of bench top and pilot lead corrosion assessment studies

    by Christina Devine, Simoni Triantafyllidou

    Bench top and pilot lead corrosion studies are gaining more interest, considering revisions and upcoming improvements to the Lead and Copper Rule. This literature review identified studies ranging from simpler month(s)‐long bench top dump‐and‐fill stagnant water tests (coupon tests/standing pipe tests) to more complicated year(s)‐long intermittent flow pilot studies (recirculating pipe loops/once through pipe rigs). With increasing complexity in design and operation, studies more closely approximated real plumbing conditions (e.g., by incorporating harvested lead pipes and intermittent flow regimes) at increased cost, footprint, and duration. Comparison of bench top and pilot designs (in terms of lead test piece age/dimensions/configuration/replicates, study duration, sample collection, and other factors) can assist drinking water utilities, consultants, academics, and others to select a design that matches their needs and constraints. No matter the choice, surrogate systems cannot replace actual system water testing and are best complemented by other corrosion assessment tools.


  • Open Access

    A holistic approach to lead pipe scale analysis: Importance, methodology, and limitations

    by Stephen M. Harmon, Jennifer Tully, Michael K. DeSantis, Michael R. Schock, Simoni Triantafyllidou, Darren A. Lytle

    With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described. Primary methods include the following: optical microscopy, powder X‐ray diffraction, inductively coupled plasma spectroscopy, X‐ray fluorescence, scanning electron microscopy with energy dispersive spectroscopy, combustion and coulometric analyses of C and S, and X‐ray absorption spectroscopy. Examples of associated pitfalls and ways to avoid them are provided, including pipe excavation/transport, sample preparation, analysis, and data interpretation. Illustrative examples are presented of practical scale analysis questions that could be answered by combinations of pipe scale analyses.


  • The impact of sampling approach and daily water usage on lead levels measured at the tap

    by Darren A. Lytle, Casey Formal, Kelly Cahalan, Christy Muhlen, Simoni Triantafyllidou


  • Effectiveness of point-of-use and pitcher filters at removing lead phosphate nanoparticles from drinking water

    by Evelyne Doré, Casey Formal, Christy Muhlen, Daniel Williams, Stephen Harmon, Maily Pham, Simoni Triantafyllidou, Darren A. Lytle


  • Lead service line identification: A review of strategies and approaches

    by Kelsey Hensley, Valerie Bosscher, Simoni Triantafyllidou, Darren A. Lytle

    Lead service lines (LSLs) represent the greatest source of lead in drinking water. Identifying the locations of LSLs can be challenging, and recent service line (SL) material surveys in Michigan, Illinois, Wisconsin, and Indiana found that on average the materials making up 16% of SLs in these states are unknown and may be lead. Given the large number of possible LSLs in the United States, new and pending regulatory requirements, LSL replacement costs, associated lead exposure risks, and the public's desire to reduce lead exposure, there is a need to rapidly and cost‐effectively identify where LSLs are located, on public and private property. This review summarizes current industry LSL identification methods, including records screening, basic visual examination of indoor plumbing, water sampling, excavation, and predictive data analyses. A qualitative comparison of method cost, accuracy, disturbance, and other impacts is provided as a starting point for utilities that are developing a feasible approach for their specific needs/constraints. Lastly, an example stepwise approach to identify unknown SL materials is proposed.Article Impact Statement: This manuscript provides water systems with a review of techniques available to identify LSLs.


  • Open Access

    Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol

    by Simoni Triantafyllidou, Jonathan Burkhardt, Jennifer Tully, Kelly Cahalan, Michael DeSantis, Darren Lytle, Michael Schock


  • Synthesis and characterization of stable lead (II) orthophosphate nanoparticle suspensions

    by Darren A. Lytle, Casey Formal, Evelyne Doré, Christy Muhlen, Stephen Harmon, Daniel Williams, Simoni Triantafyllidou, Maily Pham

    There is great interest in producing nanoparticles for various applications. The objective of this work was to develop a procedure for reproducibly creating stable lead (Pb) phosphate nanoparticle aqueous suspensions. A stable 5 mg/L Pb-phosphate nanoparticle “stock” suspension was synthesized via chemical precipitation of Pb and orthophosphate in water at pH 7.5 with 4.4 mg soluble PO4/L and 7 mg C/L dissolved inorganic carbon. The stock suspension was subsequently diluted to produce stable 0.10 mg/L Pb “challenge” water suspensions without compromising the nanoparticle size, structure, mineralogy and solubility. Specifically, the hexagonal hydroxypyromorphite nanoparticles had an average diameter of 38 nm based on transmission electron microscopy analysis and an associated Pb solubility of 0.001 mg/L. The properties of the stock suspensions were not impacted by further dilutions, and the challenge water suspensions remained stable for 24 hours. In the context of drinking water, a protocol to produce such a stable Pb nanoparticle challenge water suspension would be very useful in evaluating Pb bioavailability, identifying Pb remediation strategies, and testing filter effectiveness to remove Pb from water.


  • Field analyzers for lead quantification in drinking water samples

    by Evelyne Doré, Darren A. Lytle, Lauren Wasserstrom, Jeff Swertfeger, Simoni Triantafyllidou

    Field analyzers for the measurement of lead in drinking water samples are gaining interest from states, water utilities and building managers as rapid, inexpensive and simple tools to quantify lead concentrations. This literature review compares data quality by field analyzers to established laboratory methods and provides practical information (e.g. costs, ease-of-use) on commercial lead analyzers that are based on: (1) Electrochemistry, (2) Colorimetry and (3) Fluorescence. Between and within these three general field analyzer categories, manufacturers specify a variety of protocols to prepare the samples, which differ from the standard acidification in laboratory methods. Review of the literature raised concerns that without adequate sample preparation, field analyzers may not always fully quantify the total lead concentration, including particulate lead, thereby resulting in underestimations. Nonetheless, field analyzers have been used to quickly obtain experimental results in the laboratory, or in the field when access to laboratory equipment was limited, expensive or otherwise impractical. Field analyzers were also successfully used to detect lead from service lines, by a water utility where lead was mostly in the dissolved form. Overall, intrinsic strengths and weaknesses of field analyzers are discussed, to better balance practical convenience and adequate data quality depending on the objective.