Eun-Soo Jung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Eun-Soo Jung has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Soo-Young Lee
KAIST (Korea, Republic of)
2 shared publications- Soo-Young Lee
The School of Electrical Engineering Korea Advanced Institute of Science and Technology Daejeon Korea
2 shared publications Bo-Kyeong Kim
Korea Advanced Institute of Science and Technology
1 shared publicationDong-Gun Lee
School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
1 shared publication- Eunjoo Jeon
Principal Data Scientist, Samsung SDS Seoul South Korea
1 shared publication - HyeongGwan Son
Technology Research, Samsung SDS, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 March 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (3) , e17037
A Lightweight Deep Learning Model for Fast Electrocardiographic Beats Classification With a Wearable Cardiac Monitor: Development and Validation Study
Background: Electrocardiographic (ECG) monitors have been widely used for diagnosing cardiac arrhythmias for decades. However, accurate analysis of ECG signals is difficult and time-consuming work because large amounts of beats need to be inspected. In order to enhance ECG beat classification, machine learning and deep learning methods have been studied. However, existing studies have limitations in model rigidity, model complexity, and inference speed. Objective: To classify ECG beats effectively and efficiently, we propose a baseline model with recurrent neural networks (RNNs). Furthermore, we also propose a lightweight model with fused RNN for speeding up the prediction time on central processing units (CPUs). Methods: We used 48 ECGs from the MIT-BIH (Massachusetts Institute of Technology-Beth Israel Hospital) Arrhythmia Database, and 76 ECGs were collected with S-Patch devices developed by Samsung SDS. We developed both baseline and lightweight models on the MXNet framework. We trained both models on graphics processing units and measured both models’ inference times on CPUs. Results: Our models achieved overall beat classification accuracies of 99.72% for the baseline model with RNN and 99.80% for the lightweight model with fused RNN. Moreover, our lightweight model reduced the inference time on CPUs without any loss of accuracy. The inference time for the lightweight model for 24-hour ECGs was 3 minutes, which is 5 times faster than the baseline model. Conclusions: Both our baseline and lightweight models achieved cardiologist-level accuracies. Furthermore, our lightweight model is competitive on CPU-based wearable hardware.
- 12 March 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (3) , e17037
Open AccessA Lightweight Deep Learning Model for Fast Electrocardiographic Beats Classification With a Wearable Cardiac Monitor: Development and Validation Study
Background: Electrocardiographic (ECG) monitors have been widely used for diagnosing cardiac arrhythmias for decades. However, accurate analysis of ECG signals is difficult and time-consuming work because large amounts of beats need to be inspected. In order to enhance ECG beat classification, machine learning and deep learning methods have been studied. However, existing studies have limitations in model rigidity, model complexity, and inference speed. Objective: To classify ECG beats effectively and efficiently, we propose a baseline model with recurrent neural networks (RNNs). Furthermore, we also propose a lightweight model with fused RNN for speeding up the prediction time on central processing units (CPUs). Methods: We used 48 ECGs from the MIT-BIH (Massachusetts Institute of Technology-Beth Israel Hospital) Arrhythmia Database, and 76 ECGs were collected with S-Patch devices developed by Samsung SDS. We developed both baseline and lightweight models on the MXNet framework. We trained both models on graphics processing units and measured both models’ inference times on CPUs. Results: Our models achieved overall beat classification accuracies of 99.72% for the baseline model with RNN and 99.80% for the lightweight model with fused RNN. Moreover, our lightweight model reduced the inference time on CPUs without any loss of accuracy. The inference time for the lightweight model for 24-hour ECGs was 3 minutes, which is 5 times faster than the baseline model. Conclusions: Both our baseline and lightweight models achieved cardiologist-level accuracies. Furthermore, our lightweight model is competitive on CPU-based wearable hardware.
- Open Access
- 10 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Neural Correlates of Variations in Human Trust in Human-like Machines during Non-reciprocal Interactions
As intelligent machines have become widespread in various applications, it has become increasingly important to operate them efficiently. Monitoring human operators’ trust is required for productive interactions between humans and machines. However, neurocognitive understanding of human trust in machines is limited. In this study, we analysed human behaviours and electroencephalograms (EEGs) obtained during non-reciprocal human-machine interactions. Human subjects supervised their partner agents by monitoring and intervening in the agents’ actions in this non-reciprocal interaction, which reflected practical uses of autonomous or smart systems. Furthermore, we diversified the agents with external and internal human-like factors to understand the influence of anthropomorphism of machine agents. Agents’ internal human-likenesses were manifested in the way they conducted a task and affected subjects’ trust levels. From EEG analysis, we could define brain responses correlated with increase and decrease of trust. The effects of trust variations on brain responses were more pronounced with agents who were externally closer to humans and who elicited greater trust from the subjects. This research provides a theoretical basis for modelling human neural activities indicate trust in partner machines and can thereby contribute to the design of machines to promote efficient interactions with humans.
- 10 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessNeural Correlates of Variations in Human Trust in Human-like Machines during Non-reciprocal Interactions
As intelligent machines have become widespread in various applications, it has become increasingly important to operate them efficiently. Monitoring human operators’ trust is required for productive interactions between humans and machines. However, neurocognitive understanding of human trust in machines is limited. In this study, we analysed human behaviours and electroencephalograms (EEGs) obtained during non-reciprocal human-machine interactions. Human subjects supervised their partner agents by monitoring and intervening in the agents’ actions in this non-reciprocal interaction, which reflected practical uses of autonomous or smart systems. Furthermore, we diversified the agents with external and internal human-like factors to understand the influence of anthropomorphism of machine agents. Agents’ internal human-likenesses were manifested in the way they conducted a task and affected subjects’ trust levels. From EEG analysis, we could define brain responses correlated with increase and decrease of trust. The effects of trust variations on brain responses were more pronounced with agents who were externally closer to humans and who elicited greater trust from the subjects. This research provides a theoretical basis for modelling human neural activities indicate trust in partner machines and can thereby contribute to the design of machines to promote efficient interactions with humans.
- Open Access
- 3 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Temporally Robust Eye Movements through Task Priming and Self-referential Stimuli
Studies have demonstrated connections between eye movements and attention shifts. However, little is known about the general factors that contribute to the self-consistency of idiosyncratic scanpaths as a function of attention shifts over time. The present work repeatedly measured human eye movements at various time intervals that ranged from less than one hour to one year between recording sessions. With and without task context, subjects observed multiple images with multiple areas of interest, including their own sporadically interspersed facial images. As reactions to visual stimuli, the eye movements of individuals were compared within and between subjects. We compared scanpaths with dynamic time warping and identified subjects based on the comparisons. The results indicate that within-subject eye movement comparisons remain more similar than between-subject eye movement comparisons over time and that task context and self-referential stimuli contribute to the consistency of idiosyncrasies in attention shift patterns.
- 3 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Open AccessTemporally Robust Eye Movements through Task Priming and Self-referential Stimuli
Studies have demonstrated connections between eye movements and attention shifts. However, little is known about the general factors that contribute to the self-consistency of idiosyncratic scanpaths as a function of attention shifts over time. The present work repeatedly measured human eye movements at various time intervals that ranged from less than one hour to one year between recording sessions. With and without task context, subjects observed multiple images with multiple areas of interest, including their own sporadically interspersed facial images. As reactions to visual stimuli, the eye movements of individuals were compared within and between subjects. We compared scanpaths with dynamic time warping and identified subjects based on the comparisons. The results indicate that within-subject eye movement comparisons remain more similar than between-subject eye movement comparisons over time and that task context and self-referential stimuli contribute to the consistency of idiosyncrasies in attention shift patterns.
- 22 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9118, 91180M-91180M-6
User authentication systems based on brain finger-prints
- 22 May 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9118, 91180M-91180M-6
User authentication systems based on brain finger-prints
- 1 January 2012
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 560-567
Trust and Equity Theory in Prisoner’s Dilemma
- 1 January 2012
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 560-567
Trust and Equity Theory in Prisoner’s Dilemma