    Leveraging the revised International System of Units: torque from the fundamental constants

    by Zane Comden, Stephan Schlamminger, Frank Seifert, Kumar Arumugam, Chandra B Shahi, David B Newell, Leon S Chao

    Calibration of tools designed to apply known torques, such as torque wrenches and torque screwdrivers, requires a chain of traceable standards to the definition of the kilogram and meter derived from the revised International System of Units (SI) via physical mass and length artifact standards. We present a detailed description and experimental verification of a device which utilizes the Kibble principle to directly realize torques up to 1 N m. The second generation Electronic NIST Torque Realizer (ENTR_v2) can calibrate industrial torque tools to 0.1 % accuracy or better ultimately traceable to the fixed value of the Planck constant within the revised SI through electrical traceability chains, severing ties to the traditional physical transfer standard artifacts of length and mass.


  • Open Access

    Thoughts on the Kibble–Robinson theory

    by Lorenz Keck, Kumar Arumugam, Leon Chao, Zane Comden, Frank Seifert, David Newell, Darine Haddad, Stephan Schlamminger

    We revisit the Kibble–Robinson theory, first proposed in 2014 by Kibble and Robinson. This theory significantly simplifies the construction and operation of Kibble balances. We conducted a theoretical investigation of the theory’s assumptions, using a corner cube as the optical target in the interferometer for velocity measurement. We find that it is advantageous to build a mechanism whose output has minimal rotation and horizontal motion. For balances with relative uncertainty targets below 1 × 10 − 6 , the mass pan and the optical target should be suspended from a common gimbal so they have the same vertical velocity and no rotation. In this case, the measurement bias due to Abbe offset is minimized, and the bias due to corner loading is repeatable.


  • Open Access

    Flexures for Kibble balances: minimizing the effects of anelastic relaxation

    by Lorenz Keck, Stephan Schlamminger, René Theska, Frank Seifert, Darine Haddad

    We studied the anelastic aftereffect of a flexure being used in a Kibble balance, where the flexure is subjected to a large excursion in velocity mode after which a high-precision force comparison is performed. We investigated the effect of a constant and a sinusoidal excursion on the force comparison. We explored theoretically and experimentally a simple erasing procedure, i.e. bending the flexure in the opposite direction for a given amplitude and time. We found that the erasing procedure reduced the time-dependent force by about 30%. The investigation was performed with an analytical model and verified experimentally with our new Kibble balance at the National Institute of Standards and Technology employing flexures made from precipitation-hardened Copper Beryllium alloy C17200. Our experimental determination of the modulus defect of the flexure yields 1.2 × 10 − 4 . This result is about a factor of two higher than previously reported from experiments. We additionally found a static shift of the flexure’s internal equilibrium after a change in the stress and strain state. These static shifts, although measurable, are small and deemed uncritical for our Kibble balance application at present. During this investigation, we discovered magic flexures that promise to have very little anelastic relaxation. In these magic flexures, the mechanism causing anelastic relaxation is compensated for by properly shaping and loading a flexure with a non-constant cross-section in the region of bending.


  • Open Access

    Preliminary characterization of anelastic effects in the flexure mechanism for a new Kibble balance at NIST

    by Lorenz Keck, Frank Seifert, David Newell, René Theska, Darine Haddad

    A new Kibble balance is being built at the National Institute of Standards and Technology (NIST). For the first time in one of the highly accurate versions of this type of balance, a single passive flexure mechanism is used for both modes of operation: the weighing mode and the velocity mode. The mechanism is at the core of the new balance design as it represents a paradigm shift for NIST away from using knife edge-based balance mechanisms, which exhibit hysteresis in the measurement procedure of the weighing mode. Mechanical hysteresis may be a limiting factor in the performance of highly accurate Kibble balances approaching single digit nanonewton repeatability on a nominal 100 g mass, as targeted in this work. Flexure-based mechanisms are known to have very good static hysteresis when used as a null detector. However, for larger and especially longer lasting deformations, flexures are known to exhibit anelastic drift. We seek to characterize, and ideally compensate for, this anelastic behavior after deflections during the velocity mode to enable a 10 − 8 accurate Kibble balance-measurement on a nominal 100 g mass artifact with a single flexure-based balance mechanism. A measurement of the anelastic after-effect after static excitation hints that the apparatus produced a result for anelastic relaxation comparable to previously published work. Furthermore, a series of oscillatory displacements similar to those occurring in a velocity mode of a Kibble balance measurement are imposed upon the flexure mechanism and show a significant anelastic relaxation torque resulting in multiple micronewton of force relaxation. The amplitude of this force relaxation could be reduced by counterbending the flexures before performing a force measurement.


  • Open Access

    The Design and Performance of an Electronic Torque Standard Directly Traceable to the Revised SI

    by Zane Comden, John Draganov, Stephan Schlamminger, Frank Seifert, Charles Waduwarage Perera, David B. Newell, Leon S. Chao

    The United States National Institute of Standards and Technology (NIST) has been developing a new device for primary standard realization of torque utilizing established traceability to quantum-electrical standards following the 2019 revision of the International System of Units (SI). This device, the Electronic NIST Torque Realizer (ENTR) is a device directly traceable to the quantum-electrical standards of the revised SI with the goal of outperforming current commercial torque transducer uncertainty levels, improving torque tool calibration at low torque ranges, and shortening the torque standards dissemination chain. This project’s goal is to create a device for torque calibrations with an operational range of 7 × 10 -4 Nm to 1Nm with an uncertainty at or below 0.1 %. We intend ENTR to be a possible replacement for present transfer standards used in the torque standards dissemination chain, easing the financial and logistical burdens of current torque standards dissemination systems.


  • Open Access

    Calculation of magnetic forces and torques on the Kibble coil

    by Stephan Schlamminger, Lorenz Keck, Frank Seifert, Leon S Chao, Darine Haddad, Shisong Li

    Analytically the force acting on a current-carrying coil in a magnetic field can be calculated in two ways. First, a line integral can be conducted along the coil’s wire, summing up the differential force contributions. Each contribution results from a cross-product of the corresponding differential line segment with the magnetic flux density at that location. Alternatively, the coil’s energy in the field is given as a product of three factors, the number of turns, the current, and the flux threading the coil. The energy can then be obtained by executing a surface integral over the coil’s open surface using the scalar product of the differential surface element with the magnetic flux density as its integrand. The force on the coil is the negative derivative of the energy with respect to the appropriate coordinate. For yoke-based Kibble balances, the latter method is much simpler since most of the flux is contained in the inner yoke of the magnet and can be written as a simple equation. Here, we use this method to provide simple equations and their results for finding the torques and forces that act on a coil in a yoke-based magnet system. We further introduce a straightforward method that allows the calculation of the position and orientation difference between the coil and the magnet from three measurements.


  • Open Access

    Design of an enhanced mechanism for a new Kibble balance directly traceable to the quantum SI

    by Lorenz Keck, Frank Seifert, David Newell, Stephan Schlamminger, René Theska, Darine Haddad

    The “Quantum Electro-Mechanical Metrology Suite” (QEMMS) is being designed and built at the National Institute of Standards and Technology. It includes a Kibble balance, a graphene quantum Hall resistance array and a Josephson voltage system, so that it is a new primary standard for the unit of mass, the kilogram, directly traceable to the International System of Units (SI) based on quantum constants. We are targeting a measurement range of 10 g to 200 g and optimize the design for a relative combined uncertainty of $2\times 10^{-8}$ 2 × 10 − 8 for masses of 100 g. QEMMS will be developed as an open hardware and software design. In this article, we focus on the design of an enhanced moving and weighing mechanism for the QEMMS based on flexure pivots.


  • Open Access

    Comparison of a 100-pF Capacitor With a 12 906-Ω Resistor Using a Digital Impedance Bridge

    by Mona Feige, Stephan Schlamminger, Andrew D. Koffman, Dean G. Jarrett, Shamith Payagala, Alireza Panna, Bryan C. Waltrip, Michael Berilla, Frank Seifert, Yicheng Wang

    We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.


  • Open Access

    Magnet System for the Quantum Electromechanical Metrology Suite

    by Rafael R. Marangoni, Darine Haddad, Frank Seifert, Leon S. Chao, David B. Newell, Stephan Schlamminger


  • Open Access

    The performance of the KIBB-g1 tabletop Kibble balance at NIST

    by Leon Chao, Frank Seifert, Darine Haddad, Jon R Pratt, David B Newell, Stephan Schlamminger

    A tabletop-sized Kibble balance (KIBB-g1) designed to directly realize mass at the gram-level range with uncertainties on the order of parts in 106 has been developed at the National Institute of Standards and Technology (NIST). The masses of a nominally 5 g and 1 g weight were determined with standard uncertainties of 9.0 g and 6.7 g, respectively. The corresponding relative uncertainties are and . The construction of the instrument, capabilities, and full uncertainty budgets are presented in this manuscript.