Frank C. J. M. van Veggel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frank C. J. M. van Veggel has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
Noah J. J. Johnson
Department of Chemistry University of Victoria P.O. Box 3065 V8W 3V6 Victoria British Columbia Canada
9 shared publications- Reuven Gordon
University of Victoria
8 shared publications - Adriaan L. Frencken
Department of Chemistry, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada
7 shared publications Barbara Blasiak
Experimental Imaging Centre, University of Calgary, Calgary, Alberta T2N 4N1, Canada
7 shared publications- Boguslaw Tomanek
Institute of Nuclear Physics, Polish Academy of Sciences 4 , Radzikowskiego 152, 31-342 Kraków
6 shared publications Adriaan L. Frencken
Centre for Advanced Materials & Related Technologies (CAMTEC), University of Victoria 2 , Victoria, British Columbia V8W 2Y2, Canada
5 shared publications
Latest Publications
- Open Access
Utilizing T1- and T2-Specific Contrast Agents as “Two Colors” MRI Correlation
Magnetic resonance imaging (MRI) is widely used as a medical imaging technique due to its non-invasive nature, high spatial contrast, and virtually unlimited depth of penetration. Different modalities can be used for contrast in MRI, including T1 (spin–lattice) and T2 or T2 * (spin–spin) proton relaxation times, and specific contrast agents (CAs) have been developed that locally enhance the contrasts in MRI images. We present a method combining T1- and T2-specific CAs in a single imaging technique, referred to as correlation MRI. This technique allows different CAs to be used simultaneously to visualize contrast between multiple types of tissue in the same image when applied as targeted CAs. An obstacle for the quantitative use of correlation MRI is that T1 and T2 relaxivity changes generated by CAs are not independent of each other. Here, we measured relaxivities in mixtures with various concentrations of Cas, including Magnevist (Gd3+-based, primarily a T1 CA) and Feridex (Fe2+- and Fe3+-based, primarily a T2 CA), and compared them to theoretically predicted values. It was found that, at clinically relevant concentrations, relaxivities of the mixtures deviate from linearly added values. We finally propose a three-dimensional calibration curve to quantitatively determine the concentration in mixtures of CAs, based on the measured relaxivities.
Open AccessUtilizing T1- and T2-Specific Contrast Agents as “Two Colors” MRI Correlation
Magnetic resonance imaging (MRI) is widely used as a medical imaging technique due to its non-invasive nature, high spatial contrast, and virtually unlimited depth of penetration. Different modalities can be used for contrast in MRI, including T1 (spin–lattice) and T2 or T2 * (spin–spin) proton relaxation times, and specific contrast agents (CAs) have been developed that locally enhance the contrasts in MRI images. We present a method combining T1- and T2-specific CAs in a single imaging technique, referred to as correlation MRI. This technique allows different CAs to be used simultaneously to visualize contrast between multiple types of tissue in the same image when applied as targeted CAs. An obstacle for the quantitative use of correlation MRI is that T1 and T2 relaxivity changes generated by CAs are not independent of each other. Here, we measured relaxivities in mixtures with various concentrations of Cas, including Magnevist (Gd3+-based, primarily a T1 CA) and Feridex (Fe2+- and Fe3+-based, primarily a T2 CA), and compared them to theoretically predicted values. It was found that, at clinically relevant concentrations, relaxivities of the mixtures deviate from linearly added values. We finally propose a three-dimensional calibration curve to quantitatively determine the concentration in mixtures of CAs, based on the measured relaxivities.
- Open Access
- 13 March 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (4) , 1390-1395
Thermometric Analysis of Nanoaperture-Trapped Erbium-Containing Nanocrystals
Temperature changes in plasmonic traps can affect biomolecules and quantum emitters; therefore, several works have sought out the capability of measuring the local temperature. Those works used ionic nanopore currents, fluorescence emission variations, and fluorescence-based diffusion tracking to measure the temperature dependence of shaped nanoapertures in metal films. Here, we make use of a stable erbium-containing NaYF4 nanocrystal that gives local temperature dependence while trapped in the nanoaperture hot spot. Ratiometric analysis of the emission at different wavelengths gives local temperature variation. Since the gold film dominates the thermal characteristic, we find that films of thickness 70, 100, and 130 nm give 0.64, 0.37, and 0.25 K/mW temperature change with laser power. Therefore, using thicker films can be effective in reducing the heating when it is not desired.
- 13 March 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (4) , 1390-1395
Open AccessThermometric Analysis of Nanoaperture-Trapped Erbium-Containing Nanocrystals
Temperature changes in plasmonic traps can affect biomolecules and quantum emitters; therefore, several works have sought out the capability of measuring the local temperature. Those works used ionic nanopore currents, fluorescence emission variations, and fluorescence-based diffusion tracking to measure the temperature dependence of shaped nanoapertures in metal films. Here, we make use of a stable erbium-containing NaYF4 nanocrystal that gives local temperature dependence while trapped in the nanoaperture hot spot. Ratiometric analysis of the emission at different wavelengths gives local temperature variation. Since the gold film dominates the thermal characteristic, we find that films of thickness 70, 100, and 130 nm give 0.64, 0.37, and 0.25 K/mW temperature change with laser power. Therefore, using thicker films can be effective in reducing the heating when it is not desired.
- 6 March 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (11) , 13453-13465
X-ray-Sensitive Doped CaF2-Based MRI Contrast Agents for Local Radiation Dose Measurement
Ionizing radiation has become widely used in medicine, with application in diagnostic techniques, such as computed tomography (CT) and radiation therapy (RT), where X-rays are used to diagnose and treat tumors. The X-rays used in CT and, in particular, in RT can have harmful side effects; hence, an accurate determination of the delivered radiation dose is of utmost importance to minimize any damage to healthy tissues. For this, medical specialists mostly rely on theoretical predictions of the delivered dose or external measurements of the dose. To extend the practical use of ionizing radiation-based medical techniques, such as magnetic resonance imaging (MRI)-guided RT, a more precise measurement of the internal radiation dose internally is required. In this work, a novel approach is presented to measure dose in liquids for potential future in vivo applications. The strategy relies on MRI contrast agents (CAs) that provide a dose-sensitive signal. The demonstrated materials are (citrate-capped) CaF2 nanoparticles (NPs) doped with Eu3+ or Fe2+/Fe3+ ions. Free electrons generated by ionizing radiation allow the reduction of Eu3+, which produces a very small contrast in MRI, to Eu2+, which induces a strong contrast. Oxidative species generated by high-energy X-rays can be measured indirectly using Fe2+ because it oxidizes to Fe3+, increasing the contrast in MRI. Notably, in the results, a strong increase in the proton relaxation rates is observed for the Eu3+-doped NPs at 40 kV. At 6 MV, a significant increase in proton relaxation rates is observed using CaF2 NPs doped with Fe2+/Fe3+ after irradiation. The presented concept shows great promise for use in the clinic to measure in vivo local ionizing radiation dose, as these CAs can be intravenously injected in a saline solution.
- 6 March 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (11) , 13453-13465
X-ray-Sensitive Doped CaF2-Based MRI Contrast Agents for Local Radiation Dose Measurement
Ionizing radiation has become widely used in medicine, with application in diagnostic techniques, such as computed tomography (CT) and radiation therapy (RT), where X-rays are used to diagnose and treat tumors. The X-rays used in CT and, in particular, in RT can have harmful side effects; hence, an accurate determination of the delivered radiation dose is of utmost importance to minimize any damage to healthy tissues. For this, medical specialists mostly rely on theoretical predictions of the delivered dose or external measurements of the dose. To extend the practical use of ionizing radiation-based medical techniques, such as magnetic resonance imaging (MRI)-guided RT, a more precise measurement of the internal radiation dose internally is required. In this work, a novel approach is presented to measure dose in liquids for potential future in vivo applications. The strategy relies on MRI contrast agents (CAs) that provide a dose-sensitive signal. The demonstrated materials are (citrate-capped) CaF2 nanoparticles (NPs) doped with Eu3+ or Fe2+/Fe3+ ions. Free electrons generated by ionizing radiation allow the reduction of Eu3+, which produces a very small contrast in MRI, to Eu2+, which induces a strong contrast. Oxidative species generated by high-energy X-rays can be measured indirectly using Fe2+ because it oxidizes to Fe3+, increasing the contrast in MRI. Notably, in the results, a strong increase in the proton relaxation rates is observed for the Eu3+-doped NPs at 40 kV. At 6 MV, a significant increase in proton relaxation rates is observed using CaF2 NPs doped with Fe2+/Fe3+ after irradiation. The presented concept shows great promise for use in the clinic to measure in vivo local ionizing radiation dose, as these CAs can be intravenously injected in a saline solution.
- 5 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12649, 143-145
Nanoscale upconverter thermometers in a double-nanohole optical tweezer
Temperature measurement in plasmonic traps is important because biological molecules and quantum emitters are sensitive to temperature. While other works have used ion pore currents, fluorescence emission variation, and fluorescent diffusion tracking to measure the temperature dependence of shaped nanoapertures in metal films, here we make use of a stable erbium (Er) containing NaYF4 nanocrystals that gives local temperature dependence. The local temperature variation is determined by a ratiometric analysis of the emission at different wavelengths.
- 5 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12649, 143-145
Nanoscale upconverter thermometers in a double-nanohole optical tweezer
Temperature measurement in plasmonic traps is important because biological molecules and quantum emitters are sensitive to temperature. While other works have used ion pore currents, fluorescence emission variation, and fluorescent diffusion tracking to measure the temperature dependence of shaped nanoapertures in metal films, here we make use of a stable erbium (Er) containing NaYF4 nanocrystals that gives local temperature dependence. The local temperature variation is determined by a ratiometric analysis of the emission at different wavelengths.
- Open Access
Contrast Enhancement in MRI Using Combined Double Action Contrast Agents and Image Post-Processing in the Breast Cancer Model
Gd- and Fe-based contrast agents reduce T1 and T2 relaxation times, respectively, are frequently used in MRI, providing improved cancer detection. Recently, contrast agents changing both T1/T2 times, based on core/shell nanoparticles, have been introduced. Although advantages of the T1/T2 agents were shown, MR image contrast of cancerous versus normal adjacent tissue induced by these agents has not yet been analyzed in detail as authors considered changes in cancer MR signal or signal-to-noise ratio after contrast injection rather than changes in signal differences between cancer and normal adjacent tissue. Furthermore, the potential advantages of T1/T2 contrast agents using image manipulation such as subtraction or addition have not been yet discussed in detail. Therefore, we performed theoretical calculations of MR signal in a tumor model using T1-weighted, T2-weighted, and combined images for T1-, T2-, and T1/T2-targeted contrast agents. The results from the tumor model are followed by in vivo experiments using core/shell NaDyF4/NaGdF4 nanoparticles as T1/T2 non-targeted contrast agent in the animal model of triple negative breast cancer. The results show that subtraction of T2-weighted from T1-weighted MR images provides additional increase in the tumor contrast: over two-fold in the tumor model and 12% in the in vivo experiment.
Open AccessContrast Enhancement in MRI Using Combined Double Action Contrast Agents and Image Post-Processing in the Breast Cancer Model
Gd- and Fe-based contrast agents reduce T1 and T2 relaxation times, respectively, are frequently used in MRI, providing improved cancer detection. Recently, contrast agents changing both T1/T2 times, based on core/shell nanoparticles, have been introduced. Although advantages of the T1/T2 agents were shown, MR image contrast of cancerous versus normal adjacent tissue induced by these agents has not yet been analyzed in detail as authors considered changes in cancer MR signal or signal-to-noise ratio after contrast injection rather than changes in signal differences between cancer and normal adjacent tissue. Furthermore, the potential advantages of T1/T2 contrast agents using image manipulation such as subtraction or addition have not been yet discussed in detail. Therefore, we performed theoretical calculations of MR signal in a tumor model using T1-weighted, T2-weighted, and combined images for T1-, T2-, and T1/T2-targeted contrast agents. The results from the tumor model are followed by in vivo experiments using core/shell NaDyF4/NaGdF4 nanoparticles as T1/T2 non-targeted contrast agent in the animal model of triple negative breast cancer. The results show that subtraction of T2-weighted from T1-weighted MR images provides additional increase in the tumor contrast: over two-fold in the tumor model and 12% in the in vivo experiment.
- 16 September 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (38) , 16341-16348
The Internal Structure of Lanthanide-Doped Nanoparticles and the Effect of High-Temperature Annealing on Their Luminescent Properties
- 16 September 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (38) , 16341-16348
The Internal Structure of Lanthanide-Doped Nanoparticles and the Effect of High-Temperature Annealing on Their Luminescent Properties
- 19 January 2022
- Published by AIP Publishing in Chemical Physics Reviews
- Vol. 3 (1) , 011304
High-field magnetic resonance imaging: Challenges, advantages, and opportunities for novel contrast agents
There is a need for non-invasive diagnostic tools to detect and monitor the occurrence of diseases. Ideally, this can be done without resorting to ionizing radiation, especially when multiple rounds of imaging are required. Magnetic resonance imaging (MRI), a form of three-dimensional nuclear magnetic resonance, has become a common tool of choice for diagnosticians. Due to the low contrast difference between healthy and diseased tissue, contrast agents—magnetic species administered to the patient prior to imaging—are routinely used for contrast improvement. High-field (B0 4.7 T, 1H Larmor frequency 200 MHz) MRI offers advantages in terms of better signal-to-noise ratio, as well as improved spectral resolution for certain applications. New contrast agents are being developed for high-field MRI, the topic of this review. After discussing the purpose of contrast agents and the advantages and potential issues of high-field MRI, we discuss recent developments in the field of contrast agent design, synthesis, and applications, citing examples of high-field MRI-ready molecular contrast agents, as well as nanoparticulate contrast agents based on various inorganic materials (e.g., coordination polymers, transition metal oxides, or lanthanide halides). We will discuss how certain aspects (composition, shape, ligands) affect the contrasting abilities of these agents. Finally, we highlight recent developments in the promising field of multifunctional probes, wherein multiple imaging and/or therapeutic modalities are combined in a single species. As high-field MRI becomes more commonplace in the clinical setting, such new contrast agents are needed to provide optimized imaging. This will facilitate the clinician's task in resolving pathologies for more efficient diagnosis and patient treatment.- 19 January 2022
- Published by AIP Publishing in Chemical Physics Reviews
- Vol. 3 (1) , 011304
High-field magnetic resonance imaging: Challenges, advantages, and opportunities for novel contrast agents
There is a need for non-invasive diagnostic tools to detect and monitor the occurrence of diseases. Ideally, this can be done without resorting to ionizing radiation, especially when multiple rounds of imaging are required. Magnetic resonance imaging (MRI), a form of three-dimensional nuclear magnetic resonance, has become a common tool of choice for diagnosticians. Due to the low contrast difference between healthy and diseased tissue, contrast agents—magnetic species administered to the patient prior to imaging—are routinely used for contrast improvement. High-field (B0 4.7 T, 1H Larmor frequency 200 MHz) MRI offers advantages in terms of better signal-to-noise ratio, as well as improved spectral resolution for certain applications. New contrast agents are being developed for high-field MRI, the topic of this review. After discussing the purpose of contrast agents and the advantages and potential issues of high-field MRI, we discuss recent developments in the field of contrast agent design, synthesis, and applications, citing examples of high-field MRI-ready molecular contrast agents, as well as nanoparticulate contrast agents based on various inorganic materials (e.g., coordination polymers, transition metal oxides, or lanthanide halides). We will discuss how certain aspects (composition, shape, ligands) affect the contrasting abilities of these agents. Finally, we highlight recent developments in the promising field of multifunctional probes, wherein multiple imaging and/or therapeutic modalities are combined in a single species. As high-field MRI becomes more commonplace in the clinical setting, such new contrast agents are needed to provide optimized imaging. This will facilitate the clinician's task in resolving pathologies for more efficient diagnosis and patient treatment.- 14 May 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 154 (18) , 184204
Isolating and enhancing single-photon emitters for 1550 nm quantum light sources using double nanohole optical tweezers
Single-photon sources are required for quantum technologies and can be created from individual atoms and atom-like defects. Erbium ions produce single photons at low-loss fiber optic wavelengths, but they have low emission rates, making them challenging to isolate reliably. Here, we tune the size of gold double nanoholes (DNHs) to enhance the emission of single erbium emitters, achieving 50× enhancement over rectangular apertures previously demonstrated. This produces enough enhancement to show emission from single nanocrystals at wavelengths not seen in our previous work, i.e., 400 and 1550 nm. We observe discrete levels of emission for nanocrystals with low numbers of emitters and demonstrate isolating single emitters. We describe how the trapping time is proportional to the enhancement factor for a given DNH structure, giving us an independent way to measure the enhancement. This shows a promising path to achieving single emitter sources at 1550 nm.
- 14 May 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 154 (18) , 184204
Isolating and enhancing single-photon emitters for 1550 nm quantum light sources using double nanohole optical tweezers
Single-photon sources are required for quantum technologies and can be created from individual atoms and atom-like defects. Erbium ions produce single photons at low-loss fiber optic wavelengths, but they have low emission rates, making them challenging to isolate reliably. Here, we tune the size of gold double nanoholes (DNHs) to enhance the emission of single erbium emitters, achieving 50× enhancement over rectangular apertures previously demonstrated. This produces enough enhancement to show emission from single nanocrystals at wavelengths not seen in our previous work, i.e., 400 and 1550 nm. We observe discrete levels of emission for nanocrystals with low numbers of emitters and demonstrate isolating single emitters. We describe how the trapping time is proportional to the enhancement factor for a given DNH structure, giving us an independent way to measure the enhancement. This shows a promising path to achieving single emitter sources at 1550 nm.
- 2 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (2) , 1235-1242
Colloidally Stable Monodisperse Fe Nanoparticles as T2 Contrast Agents for High-Field Clinical and Preclinical Magnetic Resonance Imaging
- 2 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 4 (2) , 1235-1242
Colloidally Stable Monodisperse Fe Nanoparticles as T2 Contrast Agents for High-Field Clinical and Preclinical Magnetic Resonance Imaging