Arnold Janssens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arnold Janssens has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Jelle Laverge
Ghent University
9 shared publications - Marc Delghust
Ghent University Belgium
9 shared publications - Marijke Steeman
Ghent University
3 shared publications - Stijn Van de Putte
Building Physics Research Group, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41 B4, 9000 Ghent, Belgium
3 shared publications - Elisa Van Kenhove
Ghent University
2 shared publications - Lien De Backer
Ghent University
2 shared publications
Latest Publications
- 16 February 2025
- Published by Elsevier in Building and Environment
- Vol. 274
Evaluation of environmental and indoor air quality in new and renovated social housing units in Chile
- 16 February 2025
- Published by Elsevier in Building and Environment
- Vol. 274
Evaluation of environmental and indoor air quality in new and renovated social housing units in Chile
- Open Access
- 1 January 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 252
The Building Energy Performance Gap in Multifamily Buildings: A Detailed Case Study Analysis of the Energy Demand and Collective Heating System
The building energy performance gap, resulting from a discrepancy between the actual energy use and theoretical calculations, remains a persistent issue in building design. This study examines the energy performance of three multifamily buildings with a collective heating system powered by gas boilers and solar collectors: two that underwent deep renovation and one newly built. An extensive on-site monitoring system provides detailed data on both the heating demand and the final energy use. To ensure comparability, the total energy use of each unit is normalised using the energy signature method. The findings show the large spread of actual energy demands due to a wide variation in user profiles. The majority of dwellings have an actual energy use that is significantly higher than calculated, which is largely attributable to space heating. The gap is further exacerbated by substantial heat losses within the building’s heating system and by limited gains from the solar collectors, indicating discrepancies between design models and operational realities. To bridge this gap, there is a need for rigorous commissioning processes, at least during the initial operation phase start-up and ideally continuously. This can ensure more effective utilisation of renewable energy sources and reduce energy inefficiencies.
- 1 January 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 252
Open AccessThe Building Energy Performance Gap in Multifamily Buildings: A Detailed Case Study Analysis of the Energy Demand and Collective Heating System
The building energy performance gap, resulting from a discrepancy between the actual energy use and theoretical calculations, remains a persistent issue in building design. This study examines the energy performance of three multifamily buildings with a collective heating system powered by gas boilers and solar collectors: two that underwent deep renovation and one newly built. An extensive on-site monitoring system provides detailed data on both the heating demand and the final energy use. To ensure comparability, the total energy use of each unit is normalised using the energy signature method. The findings show the large spread of actual energy demands due to a wide variation in user profiles. The majority of dwellings have an actual energy use that is significantly higher than calculated, which is largely attributable to space heating. The gap is further exacerbated by substantial heat losses within the building’s heating system and by limited gains from the solar collectors, indicating discrepancies between design models and operational realities. To bridge this gap, there is a need for rigorous commissioning processes, at least during the initial operation phase start-up and ideally continuously. This can ensure more effective utilisation of renewable energy sources and reduce energy inefficiencies.
- 23 December 2024
- Published by Springer Nature
- p. 459-464
Sustainable Renovation Scenarios Towards a Flexible Building Use of a University Campus
- 23 December 2024
- Published by Springer Nature
- p. 459-464
Sustainable Renovation Scenarios Towards a Flexible Building Use of a University Campus
- 6 December 2024
- Published by Springer Nature
- p. 97-103
Performance Analysis of the Collective Heating System in Three Multifamily Buildings Using in Situ Monitoring
- 6 December 2024
- Published by Springer Nature
- p. 97-103
Performance Analysis of the Collective Heating System in Three Multifamily Buildings Using in Situ Monitoring
- 27 June 2023
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (4) , 390-392
Guest editorial: Ventilation challenges in a changing world - Selected papers from the 42 nd AIVC Conference, 5–6 October 2022
- 27 June 2023
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (4) , 390-392
Guest editorial: Ventilation challenges in a changing world - Selected papers from the 42 nd AIVC Conference, 5–6 October 2022
- 31 August 2022
- Published by Taylor & Francis in Building Research & Information
- Vol. 51 (2) , 203-222
Large-scale statistical analysis and modelling of real and regulatory total energy use in existing single-family houses in Flanders
Large-scale statistical studies on the gap between the real and regulatory energy use in residential buildings in Europe have shown that the regulatory calculation overestimated the real energy use, inflated true energy savings and undermined national energy policy making. Using data from 122,680 Flemish existing single-family houses, this research builds further on existing studies by contributing results for Flanders. The study also examines to what extent available aggregated variables explain the real annual total building energy use using statistical linear models and addresses the problem of multicollinearity and the importance of bootstrapped confidence intervals for model quality control. The overestimation of the real total energy use (and potential energy savings) by the Flemish regulatory method is exceedingly large compared to studies from other EU countries. The Flemish labels prove very poor indicators of the real energy use. Statistical linear models explain up to 46.6% of all variability and indicate that a significant extent of multicollinearity had to be corrected. Half of the variability has been left unexplained and has to be attributed to variables that were not available and the fact that the data were insufficiently accurate. Future analysis will explore whether more complex models identify more evidence.
- 31 August 2022
- Published by Taylor & Francis in Building Research & Information
- Vol. 51 (2) , 203-222
Large-scale statistical analysis and modelling of real and regulatory total energy use in existing single-family houses in Flanders
Large-scale statistical studies on the gap between the real and regulatory energy use in residential buildings in Europe have shown that the regulatory calculation overestimated the real energy use, inflated true energy savings and undermined national energy policy making. Using data from 122,680 Flemish existing single-family houses, this research builds further on existing studies by contributing results for Flanders. The study also examines to what extent available aggregated variables explain the real annual total building energy use using statistical linear models and addresses the problem of multicollinearity and the importance of bootstrapped confidence intervals for model quality control. The overestimation of the real total energy use (and potential energy savings) by the Flemish regulatory method is exceedingly large compared to studies from other EU countries. The Flemish labels prove very poor indicators of the real energy use. Statistical linear models explain up to 46.6% of all variability and indicate that a significant extent of multicollinearity had to be corrected. Half of the variability has been left unexplained and has to be attributed to variables that were not available and the fact that the data were insufficiently accurate. Future analysis will explore whether more complex models identify more evidence.
- 24 June 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 366-382
Evaluation of the relationship between window use and physical environmental variables: consistency, seasonality and diversity
Most of the window use models developed for building energy simulations include physical environmental variables as drivers. Even though it is a common approach to include these variables, the validity of this approach can be questioned based on observations in the literature regarding the consistency and seasonality of the relationship between these variables and the window use. Additionally, it was questioned whether this approach could capture the inter-occupant diversity. To assess the extent of the uncertainties, modelling methods from the literature were applied to a case study. The results revealed that a large share of the variance in window use can be attributed to the season and the household-ID. This indicates that the window use varied across the year but was stable within one season, and that these behaviours differed significantly between households. Thus occupants interacted with windows according to seasonal habits, more so then according to momentaneous environmental conditions.
- 24 June 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 366-382
Evaluation of the relationship between window use and physical environmental variables: consistency, seasonality and diversity
Most of the window use models developed for building energy simulations include physical environmental variables as drivers. Even though it is a common approach to include these variables, the validity of this approach can be questioned based on observations in the literature regarding the consistency and seasonality of the relationship between these variables and the window use. Additionally, it was questioned whether this approach could capture the inter-occupant diversity. To assess the extent of the uncertainties, modelling methods from the literature were applied to a case study. The results revealed that a large share of the variance in window use can be attributed to the season and the household-ID. This indicates that the window use varied across the year but was stable within one season, and that these behaviours differed significantly between households. Thus occupants interacted with windows according to seasonal habits, more so then according to momentaneous environmental conditions.
- Open Access
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 19003
The Use of Solar Shading in a Nearly Zero-Energy Neighbourhood
The use of solar shading can have an important influence on the internal heat gains, especially in zero-energy buildings. However, the research in literature is almost uniquely focused on offices, while information on the use of solar shading in residential dwellings is lacking. Therefore, the solar shading behaviour of occupants of a nearly zero-energy social housing neighbourhood in Belgium is analysed. Data are gathered by solar shading logging with a building monitoring system, logbooks and cross-sectional surveys. In general, the solar shades were not often adjusted, with many of the solar shades either always opened or always closed. Clear seasonal influences were observed; however, the temperature and solar irradiance did not reveal a significant relationship with the use of the solar shading. This relationship could be biased by the fact that some of the occupants use the solar shades not to prevent solar heat gains but to darken the room in the evening (blinds). Since the shades are not often adjusted and are thus in the same position for a long time, the use is independent of the prevailing weather conditions. The position of the solar shades seems to be more influenced by the personal preference of the occupant than by external factors. Additional simulations, carried out with Modelica, showed that when the full capacity of the solar shades is used, the overheating can be decreased up to 29% in south oriented rooms. The possible negative impact on the heating demands can be neglected. This shows the necessity to correctly model the solar shading behaviour in residential buildings, especially in nearly zero-energy buildings, for which the cooling demands are increasingly important.
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 19003
Open AccessThe Use of Solar Shading in a Nearly Zero-Energy Neighbourhood
The use of solar shading can have an important influence on the internal heat gains, especially in zero-energy buildings. However, the research in literature is almost uniquely focused on offices, while information on the use of solar shading in residential dwellings is lacking. Therefore, the solar shading behaviour of occupants of a nearly zero-energy social housing neighbourhood in Belgium is analysed. Data are gathered by solar shading logging with a building monitoring system, logbooks and cross-sectional surveys. In general, the solar shades were not often adjusted, with many of the solar shades either always opened or always closed. Clear seasonal influences were observed; however, the temperature and solar irradiance did not reveal a significant relationship with the use of the solar shading. This relationship could be biased by the fact that some of the occupants use the solar shades not to prevent solar heat gains but to darken the room in the evening (blinds). Since the shades are not often adjusted and are thus in the same position for a long time, the use is independent of the prevailing weather conditions. The position of the solar shades seems to be more influenced by the personal preference of the occupant than by external factors. Additional simulations, carried out with Modelica, showed that when the full capacity of the solar shades is used, the overheating can be decreased up to 29% in south oriented rooms. The possible negative impact on the heating demands can be neglected. This shows the necessity to correctly model the solar shading behaviour in residential buildings, especially in nearly zero-energy buildings, for which the cooling demands are increasingly important.
- Open Access
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 22007
Comparison of the actual and theoretical energy use in nZEB renovations of multi-family buildings using in situ monitoring
Often there is a significant difference between the actually measured and theoretically calculated energy use. The deviation between the two can be a result of errors in design, construction or commissioning, due to the technical performance of building components and installations that don’t meet the design requirements. But equally, incorrect assumptions in the calculation can largely affect the results, for example the user influence that is simulated in a different way. This paper presents the analysis of data from an on-site monitoring system of two case study multi-family buildings that were deeply refurbished. It points out that the calculated energy use for space heating was largely underestimated, while there was an overestimation of the energy use for domestic hot water. The high indoor temperature and the low occupancy of the apartments were identified as the key parameters to explain this striking difference between the theoretical design and the actual situation.
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 22007
Open AccessComparison of the actual and theoretical energy use in nZEB renovations of multi-family buildings using in situ monitoring
Often there is a significant difference between the actually measured and theoretically calculated energy use. The deviation between the two can be a result of errors in design, construction or commissioning, due to the technical performance of building components and installations that don’t meet the design requirements. But equally, incorrect assumptions in the calculation can largely affect the results, for example the user influence that is simulated in a different way. This paper presents the analysis of data from an on-site monitoring system of two case study multi-family buildings that were deeply refurbished. It points out that the calculated energy use for space heating was largely underestimated, while there was an overestimation of the energy use for domestic hot water. The high indoor temperature and the low occupancy of the apartments were identified as the key parameters to explain this striking difference between the theoretical design and the actual situation.
- 31 October 2019
- Published by SAGE Publications in Journal of Building Physics
- Vol. 43 (6) , 477-502
Implementation of rainwater infiltration measurements in hygrothermal modelling of non-insulated brick cavity walls
The watertightness of solid masonry walls is generally based on the concept of buffering and afterwards drying out the absorbed rainwater. In cavity walls, on the contrary, the air layer provides a capillary break between the inner and outer leafs allowing drainage of rainwater and preventing infiltration to the interior wall surface. For assessing moisture-related risks, heat, air and moisture models have proven to be a valuable tool, but in the case of cavity walls two problems arise: the degree of water infiltration into the cavity is unknown, and no consensus is available on the method that should be used to implement these infiltrations in a simulation. For example, for the existing buildings, it is worthwhile to investigate whether injecting cavity wall insulation induces an increase or decrease in moisture-related pathologies, in contrast to adopting a fixed performance criterion for assessment. However, to complete a thorough analysis of a brick cavity wall, it is first useful to review the hygrothermal behaviour of cavity walls as it has been previously described in the literature. As such, this article provides a summary of experimental water infiltration results for cavity walls as described in the literature, discusses experimental results of four test walls subjected to four test protocols and extracts from these results the water infiltration rate for implementation in heat, air and moisture models. Finally, several methods for implementing the infiltrations in heat, air and moisture simulations are presented and evaluated based on different damage criteria. In general, the new modelling approaches are considered to provide realistic results. Nonetheless, an in situ investigation on whether mortar bridges occur in the cavity due to poor workmanship remains crucial to understanding the hygrothermal response as mortar bridges are found to have a dominant impact on the risk of mould growth at the interior wall surface.
- 31 October 2019
- Published by SAGE Publications in Journal of Building Physics
- Vol. 43 (6) , 477-502
Implementation of rainwater infiltration measurements in hygrothermal modelling of non-insulated brick cavity walls
The watertightness of solid masonry walls is generally based on the concept of buffering and afterwards drying out the absorbed rainwater. In cavity walls, on the contrary, the air layer provides a capillary break between the inner and outer leafs allowing drainage of rainwater and preventing infiltration to the interior wall surface. For assessing moisture-related risks, heat, air and moisture models have proven to be a valuable tool, but in the case of cavity walls two problems arise: the degree of water infiltration into the cavity is unknown, and no consensus is available on the method that should be used to implement these infiltrations in a simulation. For example, for the existing buildings, it is worthwhile to investigate whether injecting cavity wall insulation induces an increase or decrease in moisture-related pathologies, in contrast to adopting a fixed performance criterion for assessment. However, to complete a thorough analysis of a brick cavity wall, it is first useful to review the hygrothermal behaviour of cavity walls as it has been previously described in the literature. As such, this article provides a summary of experimental water infiltration results for cavity walls as described in the literature, discusses experimental results of four test walls subjected to four test protocols and extracts from these results the water infiltration rate for implementation in heat, air and moisture models. Finally, several methods for implementing the infiltrations in heat, air and moisture simulations are presented and evaluated based on different damage criteria. In general, the new modelling approaches are considered to provide realistic results. Nonetheless, an in situ investigation on whether mortar bridges occur in the cavity due to poor workmanship remains crucial to understanding the hygrothermal response as mortar bridges are found to have a dominant impact on the risk of mould growth at the interior wall surface.