AAAbdulmonem Alshihri

Abdulmonem Alshihri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdulmonem Alshihri has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Larger Vertical Ridge Augmentation: A Retrospective Multicenter Comparative Analysis of Seven Surgical Techniques

    by Andreas Pabst, Abdulmonem Alshihri, Philipp Becker, Amely Hartmann, Diana Heimes, Eleni Kapogianni, Frank Kloss, Keyvan Sagheb, Markus Troeltzsch, Jochen Tunkel, et al.

    Background: Vertical alveolar ridge augmentation (ARA) > 3 mm is associated with increased surgical complexity and higher complication rates. Despite the availability of various ARA techniques and graft materials, robust comparative clinical data remain limited. This retrospective multicenter study aimed to evaluate and compare surgical and patient-relevant outcomes across seven established vertical ARA techniques. Methods: This retrospective multicenter study included 70 cases of vertical ARA > 3 mm using seven different techniques (10 cases each): an iliac crest graft (ICG), intraoral autogenous bone block (IBB), allogeneic bone block (ABB), CAD/CAM ABB, CAD/CAM titanium mesh (CAD/CAM TM), magnesium scaffold (MS), and the allogeneic shell technique (ST). The outcome parameters included harvesting and insertion time, bone gain (vertical and horizontal, after a minimum of one year), graft resorption (after one year), donor site morbidity, dehiscence rate, need for material removal, and biological and general financial costs. Results: Harvesting time significantly varied among the different ARA techniques (p = 0.0025), with the longest mean durations in ICGs (51.6 ± 5.8 min) and IBBs (36.5 ± 10.8 min), and no harvesting was required for the other techniques. Insertion times also significantly differed between the different ARA techniques (p < 0.0001) and were longest in IBBs (50.1 ± 7.5 min) and the ST (47.3 ± 13.9 min). ICGs achieved the highest vertical and horizontal bone gain (5.6 ± 0.4 mm), while ABBs and CAD/CAM ABBs showed the lowest (~3.0 mm). Resorption rates significantly differed between the different ARA techniques (p < 0.0001) and were highest for ICGs (25.9 ± 3.9%) and lowest for MSs (5.1 ± 1.5%). Donor site morbidity was 100% in ICGs and 50% in IBBs, with no morbidity in the other groups. Dehiscence rates were 10% in most techniques but 30% in CAD/CAM TMs. Removals were required in all techniques except MSs. Biological and financial costs were high for ICGs and CAD/CAM ABBs and low for MSs. Conclusions: Vertical ARA techniques significantly differ regarding harvesting and insertion time, bone gain, graft resorption, donor site morbidity, dehiscence rates, removals, and costs. While ICGs achieved the highest bone volume, less invasive techniques, such as CAD/CAM-based or resorbable scaffolds, reduced biological costs and complication risks. Technique selection should be individualized based on defects, patients, and reconstructive goals.


  • Open Access

    Translational Applications of Extracorporeal Shock Waves in Dental Medicine: A Literature Review

    by Abdulmonem Alshihri

    Extracorporeal shock wave therapy (ESWT) has been studied and applied extensively in medical practice for various applications including musculoskeletal, dermal, vascular, and cardiac indications. These indications have emerged from primary ESWT use in treating urolithiasis and cholelithiasis. Likewise, dental medicine has had its share of utilizing ESWT in various investigations. This review aimed to provide an up-to-date summary of ESWT use in preclinical and clinical dental medicine. There is growing interest in ESWT use stemming from its non-invasiveness, low cost, and safe qualities in addition to its proven regenerative biostimulating aspects. Targeted tissue and parameters of ESWT delivery continue to be an integral part of successful ESWT treatment to attain the clinical value of the anticipated dose’s effect.


  • Open Access

    An Assessment of the Influence of Dental Porcelain Slurry Preparation on Flexural Strength of Different Feldspathic Porcelains

    by Abdulmonem Alshihri, Nadin Al-Haj Husain, Kai Vogeler, Mutlu Özcan

    Chipping remains a big challenge during the clinical application of glass ceramics in dentistry. The fabrication procedure used affects the mechanical properties of dental feldspathic porcelain and is associated with technical failures. This study aimed to compare the effect of the use of manufacturers’ liquids versus H2O on the flexural strength of glass ceramics. Specimens (n = 120, n = 15 per group) (25 × 4 × 1.2 mm) were obtained using four porcelain powders (Creation CC, IPS InLine, Noritake EX-3, and Vita VM 13). Four groups were produced using porcelain powder and modeling liquid, and four groups using distilled water. The specimens were fired, sintered, and polished. Flexural strength was measured using a universal testing machine. Statistical analyses were conducted using post hoc Tukey’s, two-way ANOVA, and Weibull analysis. Flexural strength values (mean ± SD) of the ceramic-manufacturer’s liquid mixture ranged between 67.2 ± 10.2 and 85.8 ± 12.8 MPA (NR < VT < IV < CR), while flexural strength values of the ceramic–water mixture were between 72.2 ± 6.9 and 95.2 ± 12 MPA (CR < NR < VT < IV). While the choice of the ceramic type significantly affected flexural strength, the use of water vs. manufacturers’ liquid showed in almost all cases no significance. To achieve better flexural strength results, InLine should be used with distilled water mixtures, while all ceramic powders except for Noritake can be used with the manufacturer’s liquid mixtures.


  • Influence of dental college funding and time established on the satisfaction of dental graduates with their undergraduate experience in Saudi Arabia

    by Abdulmonem Alshihri, Daliah M. Salem, Talal M. Alnassar, Nawal M. Alharbi, Hussain D. Alsayed, Christopher D. Lynch, Igor R. Blum, Nairn H.F. Wilson, Mohammed S. Aldossary


  • Open Access

    Adhesion of Resin-Resin and Resin–Lithium Disilicate Ceramic: A Methodological Assessment

    by Simon Guggenbühl, Abdulmonem Alshihri, Nadin Al-Haj Husain, Mutlu Özcan

    The aim of this study was to evaluate four test methods on the adhesion of resin composite to resin composite, and resin composite to glass ceramic. Resin composite specimens (N = 180, Quadrant Universal LC) were obtained and distributed randomly to test the adhesion of resin composite material and to ceramic materials (IPS e.max CAD) using one of the four following tests: (a) Macroshear SBT: (n = 30), (b) macrotensile TBT: (n = 30), (c) microshear µSBT: (n = 30) and (d) microtensile µTBT test (n = 6, composite-composite:216 sticks, ceramic-composite:216 sticks). Bonded specimens were stored for 24 h at 23 °C. Bond strength values were measured using a universal testing machine (1 mm/min), and failure types were analysed after debonding. Data were analysed using Univariate and Tukey’s, Bonneferroni post hoc test (α = 0.05). Two-parameter Weibull modulus, scale (m), and shape (0) were calculated. Test method and substrate type significantly affected the bond strength results, as well as their interaction term (p < 0.05). Resin composite to resin composite adhesion using SBT (24.4 ± 5)a, TBT (16.1 ± 4.4)b and µSBT (20.6 ± 7.4)a,b test methods presented significantly lower mean bond values (MPa), compared to µTBT (36.7 ± 8.9)b (p < 0.05). When testing adhesion of glass ceramics to resin composite, µSBT (6.6 ± 1)B showed the lowest and µTBT (24.8 ± 7)C,D the highest test values (MPa) (SBT (14.6 ± 5)A,D and TBT (19.9 ± 5)A,B) (p < 0.05). Resin composite adhesion to ceramic vs. resin composite did show significant difference for the test methods SBT and µTBT (resin composite (24.4 ± 5; 36.7 ± 9 MPa) vs. glass ceramic (14.6 ± 5; 25 ± 7 MPa)) (p > 0.05). Among substrate–test combinations, Weibull distribution presented the highest shape values for ceramic–resin in µSBT (7.6) and resin–resin in µSBT (5.7). Cohesive failures in resin–resin bond were most frequently observed in SBT (87%), followed by TBT (50%) and µSBT (50%), while mixed failures occurred mostly in ceramic–resin bonds in the SBT (100%), TBT (90%), and µSBT (90%) test types. According to Weibull modulus, failure types, and bond strength, µTBT tests might be more reliable for testing resin-based composites adhesion to resin, while µSBT might be more suitable for adhesion testing of resin-based composites to ceramic materials.


  • A nationwide survey assessing the satisfaction of dental colleges graduates with their undergraduate experience in Saudi Arabia

    by Abdulmonem A. Alshihri, Daliah M. Salem, Talal M. Alnassar, Nawal M. Alharbi, Christopher D. Lynch, Igor R. Blum, Nairn H.F. Wilson, Mohammed S. Aldossary


  • Open Access

    Platelet-Derived Growth Factor Stimulated Migration of Bone Marrow Mesenchymal Stem Cells into an Injectable Gelatin-Hydroxyphenyl Propionic Acid Matrix

    by Wanting Niu, Teck Chuan Lim, Abdulmonem Alshihri, Ravikumar Rajappa, Lishan Wang, Motoichi Kurisawa, Myron Spector

    Bone marrow mesenchymal stem cells (bMSCs) are responsible in the repair of injured tissue through differentiation into multiple cell types and secretion of paracrine factors, and thus have a broad application profile in tissue engineering/regenerative medicine, especially for the musculoskeletal system. The lesion due to injury or disease may be a closed irregular-shaped cavity deep within tissue necessitating an injectable biomaterial permissive of host (endogenous) cell migration, proliferation and differentiation. Gelatin-hydroxyphenyl propionic acid (Gtn-HPA) is a natural biopolymer hydrogel which is covalently cross-linked by horseradish peroxidase (HRP) and hydrogen peroxide (H2O2) in situ and can be delivered to the lesion by needle injection. Growth factors and cytokines can be directly incorporated into the gel or into nano- and micro-particles, which can be employed for sustained release of biomolecules while maintaining their bioactivity. In this study, we selected polyelectrolyte complex nanoparticles (PCNs) prepared with dextran sulfate and chitosan as the carrier for platelet-derived growth factor (PDGF)-BB and stromal cell-derived factor (SDF)-1α, which have been tested effectively in recruiting stem cells. Our in vitro results showed a high degree of viability of bMSCs through the process of Gtn-HPA covalent cross-linking gelation. The Gtn-HPA matrix was highly permissive of bMSC migration, proliferation, and differentiation. PDGF-BB (20 ng/mL) directly incorporated into the gel and, alternatively, released from PCNs stimulated bMSC migration and proliferation. There were only small differences in the results for the direct incorporation of PDGF into the gel compared with its release from PCNs, and for increased doses of the growth factor (200 ng/mL and 2 µg/mL). In contrast, SDF-1α elicited an increase in migration and proliferation only when released from PCNs; its effect on migration was notably less than PDGF-BB. The in vitro results demonstrate that PDGF-BB substantially increases migration of bMSCs into Gtn-HPA and their proliferation in the gel, and that these benefits can be derived from incorporation of a relatively low dose of the growth factor directly into the gel. These findings commend the use of Gtn-HPA/PDGF-BB as an injectable therapeutic agent to treat defects in musculoskeletal tissues.


  • Correction to: Barriers to Professional Dental Care among Children with Autism Spectrum Disorder

    by Abdulmonem A. Alshihri, Mansour H. Al-Askar, Mohammed S. Aldossary

    In the original publication of the article, the author’s affiliation was processed incorrectly without the name of department. The correct affiliatio