Alias Mohd Noor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alias Mohd Noor has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Sh-Hussain Salleh
Centre for Biomedical Engineering Transportation Research Alliance, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
5 shared publications - Mahyar Hamedi
Emteq Ltd, UK
4 shared publications Sh-Hussain Salleh
Are with Center for Biomedical Engineering, Universiti Teknologi Malaysia Johor Bahru, Malaysia
4 shared publications- Chee-Ming Ting
Monash University Malaysia
3 shared publications - Uday Muwafaq Basheer
Centre for Advanced Composite Materials (CACM), University Teknologi Malaysia, Skudai, Malaysia
3 shared publications A Whitfield
School of Mechanical Engineering, University of Bath
2 shared publications
Latest Publications
- 1 June 2018
- Published by Elsevier in Materials Today Communications
- Vol. 15, 134-142
Integration and fabrication of the cheap ceramic membrane through 3D printing technology
- 1 June 2018
- Published by Elsevier in Materials Today Communications
- Vol. 15, 134-142
Integration and fabrication of the cheap ceramic membrane through 3D printing technology
- 22 May 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.29) , 31-33
Investigation on microstructure and electrical properties of Bi doping Ca3Co4O9 nanoparticles synthesized by sol-gel process
In this study, nanoparticles of Bi doped Ca3-xCo4O9 [Ca3-xBixCo4O9 where x=0, 0.2, 0.4 and 0.6] were prepared by sol gel combustion method. The phase structures and microstructures of Bi doped Ca3-xCo4O9 powders preparation were investigated. The microstructural observations of different Bi doped Ca3-xCo4O9 powders were evaluated using X-ray diffraction analysis (XRD) and Variable Pressure Scanning Electron Microscope (VPSEM). The bulk Ca3-xBixCo4O9 samples were fabricated using uniaxial cold pressing technique. Electrical resistivity of bulk Ca3-xBixCo4O9 samples with different doping was measured using four-probe method from 300 to 700°K. The electrical resistivity was found to decrease with increasing temperature for the bulk Ca3-xBixCo4O9 samples. The electrical properties of Ca3-xBixCo4O9 are non-monotonic functions of x.
- 22 May 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.29) , 31-33
Investigation on microstructure and electrical properties of Bi doping Ca3Co4O9 nanoparticles synthesized by sol-gel process
In this study, nanoparticles of Bi doped Ca3-xCo4O9 [Ca3-xBixCo4O9 where x=0, 0.2, 0.4 and 0.6] were prepared by sol gel combustion method. The phase structures and microstructures of Bi doped Ca3-xCo4O9 powders preparation were investigated. The microstructural observations of different Bi doped Ca3-xCo4O9 powders were evaluated using X-ray diffraction analysis (XRD) and Variable Pressure Scanning Electron Microscope (VPSEM). The bulk Ca3-xBixCo4O9 samples were fabricated using uniaxial cold pressing technique. Electrical resistivity of bulk Ca3-xBixCo4O9 samples with different doping was measured using four-probe method from 300 to 700°K. The electrical resistivity was found to decrease with increasing temperature for the bulk Ca3-xBixCo4O9 samples. The electrical properties of Ca3-xBixCo4O9 are non-monotonic functions of x.
- 1 November 2016
- Published by Elsevier in Materials & Design
- Vol. 109, 47-56
Microstructural evaluation of a slurry based Ni/YSZ thermal barrier coating for automotive turbocharger turbine application
- 1 November 2016
- Published by Elsevier in Materials & Design
- Vol. 109, 47-56
Microstructural evaluation of a slurry based Ni/YSZ thermal barrier coating for automotive turbocharger turbine application
- 1 June 2016
- Published by MIT Press in Neural Computation
- Vol. 28 (6) , 999-1041
Electroencephalographic Motor Imagery Brain Connectivity Analysis for BCI: A Review
Recent research has reached a consensus on the feasibility of motor imagery brain-computer interface (MI-BCI) for different applications, especially in stroke rehabilitation. Most MI-BCI systems rely on temporal, spectral, and spatial features of single channels to distinguish different MI patterns. However, no successful communication has been established for a completely locked-in subject. To provide more useful and informative features, it has been recommended to take into account the relationships among electroencephalographic (EEG) sensor/source signals in the form of brain connectivity as an efficient tool of neuroscience. In this review, we briefly report the challenges and limitations of conventional MI-BCIs. Brain connectivity analysis, particularly functional and effective, has been described as one of the most promising approaches for improving MI-BCI performance. An extensive literature on EEG-based MI brain connectivity analysis of healthy subjects is reviewed. We subsequently discuss the brain connectomes during left and right hand, feet, and tongue MI movements. Moreover, key components involved in brain connectivity analysis that considerably affect the results are explained. Finally, possible technical shortcomings that may have influenced the results in previous research are addressed and suggestions are provided.
- 1 June 2016
- Published by MIT Press in Neural Computation
- Vol. 28 (6) , 999-1041
Electroencephalographic Motor Imagery Brain Connectivity Analysis for BCI: A Review
Recent research has reached a consensus on the feasibility of motor imagery brain-computer interface (MI-BCI) for different applications, especially in stroke rehabilitation. Most MI-BCI systems rely on temporal, spectral, and spatial features of single channels to distinguish different MI patterns. However, no successful communication has been established for a completely locked-in subject. To provide more useful and informative features, it has been recommended to take into account the relationships among electroencephalographic (EEG) sensor/source signals in the form of brain connectivity as an efficient tool of neuroscience. In this review, we briefly report the challenges and limitations of conventional MI-BCIs. Brain connectivity analysis, particularly functional and effective, has been described as one of the most promising approaches for improving MI-BCI performance. An extensive literature on EEG-based MI brain connectivity analysis of healthy subjects is reviewed. We subsequently discuss the brain connectomes during left and right hand, feet, and tongue MI movements. Moreover, key components involved in brain connectivity analysis that considerably affect the results are explained. Finally, possible technical shortcomings that may have influenced the results in previous research are addressed and suggestions are provided.
- 19 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. 9 (1) , 102-115
Robust Facial Expression Recognition for MuCI: A Comprehensive Neuromuscular Signal Analysis
This paper presents a comprehensive study on the analysis of neuromuscular signal activities to recognize 11 facial expressions for muscle computer interfacing applications. A robust denoising protocol comprised of Wavelet transform and Kalman filtering is proposed to enhance the electromyogram (EMG) signal-to-noise ratio and improve classification performance. The effectiveness of eight different time-domain facial EMG features on system performance is examined and compared in order to identify the most discriminative one. Fourteen pattern recognition-based algorithms are employed to classify the extracted features. These classifiers are evaluated in terms of classification accuracy and processing time. Finally, the best methods that obtain almost identical system performance are compared through the Normalized Mutual Information (NMI) criterion and a repeated measure analysis of variance (ANOVA) for a statistical significant test.To clarify the impact of signal denoising, all considered EMG features and classifiers are assessed with and without this stage. Results show that: (1) the proposed denosing step significantly improves the system performance; (2) root mean square is the most discriminative facial EMG feature; (3) discriminant analysis when the parameters are estimated by the Maximum Likelihood algorithm achieves the highest classification accuracy and NMI; however, ANOVA reveals no significant difference among the best methods with almost similar performance.
- 19 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. 9 (1) , 102-115
Robust Facial Expression Recognition for MuCI: A Comprehensive Neuromuscular Signal Analysis
This paper presents a comprehensive study on the analysis of neuromuscular signal activities to recognize 11 facial expressions for muscle computer interfacing applications. A robust denoising protocol comprised of Wavelet transform and Kalman filtering is proposed to enhance the electromyogram (EMG) signal-to-noise ratio and improve classification performance. The effectiveness of eight different time-domain facial EMG features on system performance is examined and compared in order to identify the most discriminative one. Fourteen pattern recognition-based algorithms are employed to classify the extracted features. These classifiers are evaluated in terms of classification accuracy and processing time. Finally, the best methods that obtain almost identical system performance are compared through the Normalized Mutual Information (NMI) criterion and a repeated measure analysis of variance (ANOVA) for a statistical significant test.To clarify the impact of signal denoising, all considered EMG features and classifiers are assessed with and without this stage. Results show that: (1) the proposed denosing step significantly improves the system performance; (2) root mean square is the most discriminative facial EMG feature; (3) discriminant analysis when the parameters are estimated by the Maximum Likelihood algorithm achieves the highest classification accuracy and NMI; however, ANOVA reveals no significant difference among the best methods with almost similar performance.
- 1 May 2015
- Published by Elsevier in Applied Soft Computing
- Vol. 30, 83-93
Facial neuromuscular signal classification by means of least square support vector machine for MuCI
- 1 May 2015
- Published by Elsevier in Applied Soft Computing
- Vol. 30, 83-93
Facial neuromuscular signal classification by means of least square support vector machine for MuCI
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 295-299
Asynchronous multiclass mental tasks classification through very fast Versatile Elliptic Basis Function Neural Network
Developing efficient and usable brain-computer interfaces (BCIs) requires well-designed trade-off between accuracy and computational time. This paper presents a very fast and accurate method to classify asynchronous brain signals from a multi-class mental tasks dataset using time-domain features. Five different statistical time-domain features were extracted to characterize various properties of three mental tasks electroencephalograms (EEGs). Versatile Elliptic Basis Function Neural Network (VEBFNN) was employed to classify single EEG features as well as multi-feature set. Discriminating power of single features was evaluated and compared by considering the classification accuracy and computational cost consumed during the training stage. Finally, the performance of the best single EEG feature was compared to the multi-feature set. The results indicated the usefulness of Willison Amplitude EEG feature in classifying the different motor tasks as it provided the highest discrimination ratio. Classification results showed the high potential of VEBFNN by the average 89.78% accuracy and 0.21 seconds computation time obtained for its offline training. Moreover, VEBFNN outperformed the conventional support vector machine classifier in both terms of accuracy and speed.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 295-299
Asynchronous multiclass mental tasks classification through very fast Versatile Elliptic Basis Function Neural Network
Developing efficient and usable brain-computer interfaces (BCIs) requires well-designed trade-off between accuracy and computational time. This paper presents a very fast and accurate method to classify asynchronous brain signals from a multi-class mental tasks dataset using time-domain features. Five different statistical time-domain features were extracted to characterize various properties of three mental tasks electroencephalograms (EEGs). Versatile Elliptic Basis Function Neural Network (VEBFNN) was employed to classify single EEG features as well as multi-feature set. Discriminating power of single features was evaluated and compared by considering the classification accuracy and computational cost consumed during the training stage. Finally, the performance of the best single EEG feature was compared to the multi-feature set. The results indicated the usefulness of Willison Amplitude EEG feature in classifying the different motor tasks as it provided the highest discrimination ratio. Classification results showed the high potential of VEBFNN by the average 89.78% accuracy and 0.21 seconds computation time obtained for its offline training. Moreover, VEBFNN outperformed the conventional support vector machine classifier in both terms of accuracy and speed.
- 27 February 2014
- Published by Springer Nature
- p. 285-294
Comparison of Multilayer Perceptron and Radial Basis Function Neural Networks for EMG-Based Facial Gesture Recognition
- 27 February 2014
- Published by Springer Nature
- p. 285-294
Comparison of Multilayer Perceptron and Radial Basis Function Neural Networks for EMG-Based Facial Gesture Recognition
- Open Access
- 3 February 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 30
Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
- 3 February 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 30
Open AccessDesign process of cementless femoral stem using a nonlinear three dimensional finite element analysis
Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 4827-4830
Linear dynamic models for classification of single-trial EEG
This paper investigates the use of linear dynamic models (LDMs) to improve classification of single-trial EEG signals. Existing dynamic classification of EEG uses discrete-state hidden Markov models (HMMs) based on piecewise-stationary assumption, which is inadequate for modeling the highly non-stationary dynamics underlying EEG. The continuous hidden states of LDMs could better describe this continuously changing characteristic of EEG, and thus improve the classification performance. We consider two examples of LDM: a simple local level model (LLM) and a time-varying autoregressive (TVAR) state-space model. AR parameters and band power are used as features. Parameter estimation of the LDMs is performed by using expectation-maximization (EM) algorithm. We also investigate different covariance modeling of Gaussian noises in LDMs for EEG classification. The experimental results on two-class motor-imagery classification show that both types of LDMs outperform the HMM baseline, with the best relative accuracy improvement of 14.8% by LLM with full covariance for Gaussian noises. It may due to that LDMs offer more flexibility in fitting the underlying dynamics of EEG.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 4827-4830
Linear dynamic models for classification of single-trial EEG
This paper investigates the use of linear dynamic models (LDMs) to improve classification of single-trial EEG signals. Existing dynamic classification of EEG uses discrete-state hidden Markov models (HMMs) based on piecewise-stationary assumption, which is inadequate for modeling the highly non-stationary dynamics underlying EEG. The continuous hidden states of LDMs could better describe this continuously changing characteristic of EEG, and thus improve the classification performance. We consider two examples of LDM: a simple local level model (LLM) and a time-varying autoregressive (TVAR) state-space model. AR parameters and band power are used as features. Parameter estimation of the LDMs is performed by using expectation-maximization (EM) algorithm. We also investigate different covariance modeling of Gaussian noises in LDMs for EEG classification. The experimental results on two-class motor-imagery classification show that both types of LDMs outperform the HMM baseline, with the best relative accuracy improvement of 14.8% by LLM with full covariance for Gaussian noises. It may due to that LDMs offer more flexibility in fitting the underlying dynamics of EEG.