Kareem Al Nahas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kareem Al Nahas has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Felix Keyser
Cavendish Laboratory, University of Cambridge, Cambridge, UK
14 shared publications - Jehangir Cama
Living Systems Institute, University of Exeter, Stocker Road, Exeter EX4 4QD, UK
9 shared publications - Marcus Fletcher
Department of Chemical Engineering Imperial College London London UK
6 shared publications - Katharine Hammond
National Physical Laboratory, Hampton Road, Teddington TW11 0LW, U.K.
4 shared publications - Maxim G. Ryadnov
National Physical Laboratory, Teddington, UK
4 shared publications - Petra Schwille
Department of Cellular and Molecular Biophysics Max Planck Institute of Biochemistry Martinsried Germany
4 shared publications
Latest Publications
- Open Access
- 15 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8415
Automated synthetic cell-based screening for designed proteins with emergent functions
Designing minimal biological systems with emergent functions such as spatiotemporal self-organization is a central goal of bottom-up synthetic biology. While computational optimization and design show promise in accelerating functional protein engineering through Design-Build-Test-Learn cycles, screening libraries for complex functions remains a major challenge. Conventional screens typically lack the spatiotemporal resolution and cell-like confinement required in bottom-up synthetic biology. Here, we present PUREdrop, an automated microfluidic platform that encapsulates and expresses protein libraries in thousands of picoliter-sized synthetic cells per construct. PUREdrop distributes these across predefined wells of a 96-well plate for time-lapse imaging, enabling parallel quantification of expression kinetics and emergent functions. To demonstrate the platform’s potential, we first screen computationally re-designed variants of the bacterial cell division protein FtsZ, and identify variants with altered bundling phenotypes and distinct kinetics. We then extend our screening procedure to general protein modulators of FtsZ and identify a combination that anchors filaments to the interface, producing a ring-like phenotype. PUREdrop bridges computational protein engineering and synthetic cell research, elevating the rational engineering of complex biological function to the next level.
- 15 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8415
Open AccessAutomated synthetic cell-based screening for designed proteins with emergent functions
Designing minimal biological systems with emergent functions such as spatiotemporal self-organization is a central goal of bottom-up synthetic biology. While computational optimization and design show promise in accelerating functional protein engineering through Design-Build-Test-Learn cycles, screening libraries for complex functions remains a major challenge. Conventional screens typically lack the spatiotemporal resolution and cell-like confinement required in bottom-up synthetic biology. Here, we present PUREdrop, an automated microfluidic platform that encapsulates and expresses protein libraries in thousands of picoliter-sized synthetic cells per construct. PUREdrop distributes these across predefined wells of a 96-well plate for time-lapse imaging, enabling parallel quantification of expression kinetics and emergent functions. To demonstrate the platform’s potential, we first screen computationally re-designed variants of the bacterial cell division protein FtsZ, and identify variants with altered bundling phenotypes and distinct kinetics. We then extend our screening procedure to general protein modulators of FtsZ and identify a combination that anchors filaments to the interface, producing a ring-like phenotype. PUREdrop bridges computational protein engineering and synthetic cell research, elevating the rational engineering of complex biological function to the next level.
- Open Access
Automated Synthetic Cell-based Screening for Designed Proteins with Emergent Functions
Designing minimal biological systems with emergent functions such as spatiotemporal self-organization is a central goal of bottom-up synthetic biology. While computational optimization and design show promises to accelerate functional protein engineering through Design-Build-Test-Learn cycles, screening libraries for complex functions remains a major challenge. Conventional screens typically lack the spatiotemporal resolution and cell-like confinement required in bottom-up synthetic biology. Here, we present PUREdrop, an automated microfluidic platform that encapsulates and expresses protein libraries in thousands of picolitre-sized synthetic cells per construct. These droplets are sorted into a 96-well plate and analyzed by time-lapse imaging, allowing parallel quantification of expression kinetics and emergent functions. To demonstrate the platform’s potential, we first screened computationally re-designed variants of the bacterial cell division protein FtsZ, identifying variants with improved bundling phenotypes and faster kinetics. We then extended our screening procedure towards general protein modulators of FtsZ and identified a combination that anchors filaments to the interface, producing a ring-like phenotype. PUREdrop bridges computational protein engineering and synthetic cell research, elevating the rational engineering of complex biological function to the next level.
Open AccessAutomated Synthetic Cell-based Screening for Designed Proteins with Emergent Functions
Designing minimal biological systems with emergent functions such as spatiotemporal self-organization is a central goal of bottom-up synthetic biology. While computational optimization and design show promises to accelerate functional protein engineering through Design-Build-Test-Learn cycles, screening libraries for complex functions remains a major challenge. Conventional screens typically lack the spatiotemporal resolution and cell-like confinement required in bottom-up synthetic biology. Here, we present PUREdrop, an automated microfluidic platform that encapsulates and expresses protein libraries in thousands of picolitre-sized synthetic cells per construct. These droplets are sorted into a 96-well plate and analyzed by time-lapse imaging, allowing parallel quantification of expression kinetics and emergent functions. To demonstrate the platform’s potential, we first screened computationally re-designed variants of the bacterial cell division protein FtsZ, identifying variants with improved bundling phenotypes and faster kinetics. We then extended our screening procedure towards general protein modulators of FtsZ and identified a combination that anchors filaments to the interface, producing a ring-like phenotype. PUREdrop bridges computational protein engineering and synthetic cell research, elevating the rational engineering of complex biological function to the next level.
- Open Access
- 18 January 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (16) , e2311176
Light‐Activated Synthetic Rotary Motors in Lipid Membranes Induce Shape Changes Through Membrane Expansion
Membranes are the key structures to separate and spatially organize cellular systems. Their rich dynamics and transformations during the cell cycle are orchestrated by specific membrane‐targeted molecular machineries, many of which operate through energy dissipation. Likewise, man‐made light‐activated molecular rotary motors have previously shown drastic effects on cellular systems, but their physical roles on and within lipid membranes remain largely unexplored. Here, the impact of rotary motors on well‐defined biological membranes is systematically investigated. Notably, dramatic mechanical transformations are observed in these systems upon motor irradiation, indicative of motor‐induced membrane expansion. The influence of several factors on this phenomenon is systematically explored, such as motor concentration and membrane composition., Membrane fluidity is found to play a crucial role in motor‐induced deformations, while only minor contributions from local heating and singlet oxygen generation are observed. Most remarkably, the membrane area expansion under the influence of the motors continues as long as irradiation is maintained, and the system stays out‐of‐equilibrium. Overall, this research contributes to a comprehensive understanding of molecular motors interacting with biological membranes, elucidating the multifaceted factors that govern membrane responses and shape transitions in the presence of these remarkable molecular machines, thereby supporting their future applications in chemical biology.
- 18 January 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (16) , e2311176
Open AccessLight‐Activated Synthetic Rotary Motors in Lipid Membranes Induce Shape Changes Through Membrane Expansion
Membranes are the key structures to separate and spatially organize cellular systems. Their rich dynamics and transformations during the cell cycle are orchestrated by specific membrane‐targeted molecular machineries, many of which operate through energy dissipation. Likewise, man‐made light‐activated molecular rotary motors have previously shown drastic effects on cellular systems, but their physical roles on and within lipid membranes remain largely unexplored. Here, the impact of rotary motors on well‐defined biological membranes is systematically investigated. Notably, dramatic mechanical transformations are observed in these systems upon motor irradiation, indicative of motor‐induced membrane expansion. The influence of several factors on this phenomenon is systematically explored, such as motor concentration and membrane composition., Membrane fluidity is found to play a crucial role in motor‐induced deformations, while only minor contributions from local heating and singlet oxygen generation are observed. Most remarkably, the membrane area expansion under the influence of the motors continues as long as irradiation is maintained, and the system stays out‐of‐equilibrium. Overall, this research contributes to a comprehensive understanding of molecular motors interacting with biological membranes, elucidating the multifaceted factors that govern membrane responses and shape transitions in the presence of these remarkable molecular machines, thereby supporting their future applications in chemical biology.
- Open Access
- 11 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Light-activated synthetic rotary motors in lipid membranes induce shape changes through membrane expansion
In biology, membranes are the key structures to separate and spatially organize cellular reaction systems. Their rich dynamics and transformations during the cell cycle are orchestrated by specific membrane-targeted molecular machineries many of which operate through energy dissipation. Likewise, man-made molecular rotary motors powered by light have previously shown drastic effects on cellular systems, but their physical roles on and within lipid membranes remain largely unexplored. Here we systematically investigate the impact of rotary molecular motors on well-defined biological membrane systems, focusing on supported lipid bilayers (SLBs) and giant unilamellar vesicles (GUVs). Notably, we observe dramatic mechanical transformations of these systems upon motor irradiation, indicative of motor-induced membrane expansion. We systematically explore the influence of several factors on this phenomenon, such as motor concentration and membrane composition, and find that in particular, membrane fluidity plays a crucial role in motor-induced deformations. At the same time, only minor contributions from local heating and singlet oxygen generation are observed. Most remarkably, we find that membrane area expansion under the influence of the motors continues as long as irradiation is maintained, and the system stays out-of-equilibrium. Overall, this research contributes to a comprehensive understanding of how molecular motors interact with biological membranes, elucidating the multifaceted factors that govern membrane responses and shape transitions in the presence of these remarkable molecular machines, thereby supporting their future applications in chemical biology.
- 11 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessLight-activated synthetic rotary motors in lipid membranes induce shape changes through membrane expansion
In biology, membranes are the key structures to separate and spatially organize cellular reaction systems. Their rich dynamics and transformations during the cell cycle are orchestrated by specific membrane-targeted molecular machineries many of which operate through energy dissipation. Likewise, man-made molecular rotary motors powered by light have previously shown drastic effects on cellular systems, but their physical roles on and within lipid membranes remain largely unexplored. Here we systematically investigate the impact of rotary molecular motors on well-defined biological membrane systems, focusing on supported lipid bilayers (SLBs) and giant unilamellar vesicles (GUVs). Notably, we observe dramatic mechanical transformations of these systems upon motor irradiation, indicative of motor-induced membrane expansion. We systematically explore the influence of several factors on this phenomenon, such as motor concentration and membrane composition, and find that in particular, membrane fluidity plays a crucial role in motor-induced deformations. At the same time, only minor contributions from local heating and singlet oxygen generation are observed. Most remarkably, we find that membrane area expansion under the influence of the motors continues as long as irradiation is maintained, and the system stays out-of-equilibrium. Overall, this research contributes to a comprehensive understanding of how molecular motors interact with biological membranes, elucidating the multifaceted factors that govern membrane responses and shape transitions in the presence of these remarkable molecular machines, thereby supporting their future applications in chemical biology.
- Open Access
- 12 October 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (10) , 17128-17138
DNA-Based Optical Quantification of Ion Transport across Giant Vesicles
Accurate measurements of ion permeability through cellular membranes remains challenging due to the lack of suitable ion-selective probes. Here we use giant unilamellar vesicles (GUVs) as membrane models for the direct visualization of mass translocation at the single-vesicle level. Ion transport is indicated with a fluorescently adjustable DNA-based sensor that accurately detects sub-millimolar variations in K+ concentration. In combination with microfluidics, we employed our DNA-based K+ sensor for extraction of the permeation coefficient of potassium ions. We measured K+ permeability coefficients at least 1 order of magnitude larger than previously reported values from bulk experiments and show that permeation rates across the lipid bilayer increase in the presence of octanol. In addition, an analysis of the K+ flux in different concentration gradients allows us to estimate the complementary H+ flux that dissipates the charge imbalance across the GUV membrane. Subsequently, we show that our sensor can quantify the K+ transport across prototypical cation-selective ion channels, gramicidin A and OmpF, revealing their relative H+/K+ selectivity. Our results show that gramicidin A is much more selective to protons than OmpF with a H+/K+ permeability ratio of ∼104.
- 12 October 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (10) , 17128-17138
Open AccessDNA-Based Optical Quantification of Ion Transport across Giant Vesicles
Accurate measurements of ion permeability through cellular membranes remains challenging due to the lack of suitable ion-selective probes. Here we use giant unilamellar vesicles (GUVs) as membrane models for the direct visualization of mass translocation at the single-vesicle level. Ion transport is indicated with a fluorescently adjustable DNA-based sensor that accurately detects sub-millimolar variations in K+ concentration. In combination with microfluidics, we employed our DNA-based K+ sensor for extraction of the permeation coefficient of potassium ions. We measured K+ permeability coefficients at least 1 order of magnitude larger than previously reported values from bulk experiments and show that permeation rates across the lipid bilayer increase in the presence of octanol. In addition, an analysis of the K+ flux in different concentration gradients allows us to estimate the complementary H+ flux that dissipates the charge imbalance across the GUV membrane. Subsequently, we show that our sensor can quantify the K+ transport across prototypical cation-selective ion channels, gramicidin A and OmpF, revealing their relative H+/K+ selectivity. Our results show that gramicidin A is much more selective to protons than OmpF with a H+/K+ permeability ratio of ∼104.
- Open Access
- 27 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (27) , 9530-9539
Measuring Thousands of Single-Vesicle Leakage Events Reveals the Mode of Action of Antimicrobial Peptides
Host defense or antimicrobial peptides hold promise for providing new pipelines of effective antimicrobial agents. Their activity quantified against model phospholipid membranes is fundamental to a detailed understanding of their structure-activity relationships. However, classical characterization assays often lack the ability to achieve this insight. Leveraging a highly parallelized microfluidic platform for trapping and studying thousands of giant unilamellar vesicles, we conducted quantitative long-term microscopy studies to monitor the membrane-disruptive activity of archetypal antimicrobial peptides with a high spatiotemporal resolution. We described the modes of action of these peptides via measurements of the disruption of the vesicle population under the conditions of continuous peptide dosing using a range of concentrations and related the observed modes to the molecular activity mechanisms of these peptides. The study offers an effective approach for characterizing membrane-targeting antimicrobial agents in a standardized manner and for assigning specific modes of action to the corresponding antimicrobial mechanisms.
- 27 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (27) , 9530-9539
Open AccessMeasuring Thousands of Single-Vesicle Leakage Events Reveals the Mode of Action of Antimicrobial Peptides
Host defense or antimicrobial peptides hold promise for providing new pipelines of effective antimicrobial agents. Their activity quantified against model phospholipid membranes is fundamental to a detailed understanding of their structure-activity relationships. However, classical characterization assays often lack the ability to achieve this insight. Leveraging a highly parallelized microfluidic platform for trapping and studying thousands of giant unilamellar vesicles, we conducted quantitative long-term microscopy studies to monitor the membrane-disruptive activity of archetypal antimicrobial peptides with a high spatiotemporal resolution. We described the modes of action of these peptides via measurements of the disruption of the vesicle population under the conditions of continuous peptide dosing using a range of concentrations and related the observed modes to the molecular activity mechanisms of these peptides. The study offers an effective approach for characterizing membrane-targeting antimicrobial agents in a standardized manner and for assigning specific modes of action to the corresponding antimicrobial mechanisms.
- Open Access
- 11 November 2021
- Published by American Chemical Society (ACS) in ACS Synthetic Biology
- Vol. 10 (11) , 3105-3116
A Microfluidic Platform for Sequential Assembly and Separation of Synthetic Cell Models
- 11 November 2021
- Published by American Chemical Society (ACS) in ACS Synthetic Biology
- Vol. 10 (11) , 3105-3116
Open AccessA Microfluidic Platform for Sequential Assembly and Separation of Synthetic Cell Models
- Open Access
A microfluidic platform for sequential assembly and separation of synthetic cell models
Cell-sized vesicles like giant unilamellar vesicles (GUVs) are established as a promising biomimetic model for studying cellular phenomena in isolation. However, the presence of residual components and by-products, generated during vesicles preparation and manipulation, severely limits the utility of GUVs in applications like synthetic cells. Therefore, with the rapidly growing field of synthetic biology, there is an emergent demand for techniques that can continuously purify cell-like vesicles from diverse residues, while GUVs are being simultaneously synthesized and manipulated. We developed a microfluidic platform capable of purifying GUVs through stream bifurcation, where a stream of vesicles suspension is partitioned into three fractions - purified GUVs, residual components, and a washing solution. Using our purification approach, we showed that giant vesicles can be separated from various residues – that range in size and chemical composition – with a very high efficiency ( e = 0.99), based on size and deformability of the filtered objects. In addition, by incorporating the purification module with a microfluidic-based GUV-formation method, octanol-assisted liposome assembly (OLA), we established an integrated production-purification microfluidic unit that sequentially produces, manipulates, and purifies GUVs. We demonstrate the applicability of the integrated device to synthetic biology through sequentially fusing SUVs with freshly prepared GUVs and separating the fused GUVs from extraneous SUVs and oil droplets at the same time.
Open AccessA microfluidic platform for sequential assembly and separation of synthetic cell models
Cell-sized vesicles like giant unilamellar vesicles (GUVs) are established as a promising biomimetic model for studying cellular phenomena in isolation. However, the presence of residual components and by-products, generated during vesicles preparation and manipulation, severely limits the utility of GUVs in applications like synthetic cells. Therefore, with the rapidly growing field of synthetic biology, there is an emergent demand for techniques that can continuously purify cell-like vesicles from diverse residues, while GUVs are being simultaneously synthesized and manipulated. We developed a microfluidic platform capable of purifying GUVs through stream bifurcation, where a stream of vesicles suspension is partitioned into three fractions - purified GUVs, residual components, and a washing solution. Using our purification approach, we showed that giant vesicles can be separated from various residues – that range in size and chemical composition – with a very high efficiency ( e = 0.99), based on size and deformability of the filtered objects. In addition, by incorporating the purification module with a microfluidic-based GUV-formation method, octanol-assisted liposome assembly (OLA), we established an integrated production-purification microfluidic unit that sequentially produces, manipulates, and purifies GUVs. We demonstrate the applicability of the integrated device to synthetic biology through sequentially fusing SUVs with freshly prepared GUVs and separating the fused GUVs from extraneous SUVs and oil droplets at the same time.
- Open Access
Measuring thousands of single vesicle leakage events reveals the mode of action of antimicrobial peptides
Host defense or antimicrobial peptides hold promise for providing new pipelines of effective antimicrobial agents. Their activity quantified against model phospholipid membranes is fundamental to a detailed understanding of their structure-activity relationships. However, existing characterization assays lack the resolution necessary to achieve this insight. Leveraging a highly parallelized microfluidic platform for trapping and studying thousands of giant unilamellar vesicles, we conducted quantitative long-term microscopy studies to monitor the membrane-disruptive activity of archetypal antimicrobial peptides with a high spatiotemporal resolution. We described the modes of action of these peptides via measurements of the disruption of the vesicle population under the conditions of continuous peptide dosing using a range of concentrations, and related the observed modes with the molecular activity mechanisms of these peptides. The study offers an effective approach for characterizing membrane-targeting antimicrobial agents in a standardized manner, and for assigning specific modes of action to the corresponding antimicrobial mechanisms.
Open AccessMeasuring thousands of single vesicle leakage events reveals the mode of action of antimicrobial peptides
Host defense or antimicrobial peptides hold promise for providing new pipelines of effective antimicrobial agents. Their activity quantified against model phospholipid membranes is fundamental to a detailed understanding of their structure-activity relationships. However, existing characterization assays lack the resolution necessary to achieve this insight. Leveraging a highly parallelized microfluidic platform for trapping and studying thousands of giant unilamellar vesicles, we conducted quantitative long-term microscopy studies to monitor the membrane-disruptive activity of archetypal antimicrobial peptides with a high spatiotemporal resolution. We described the modes of action of these peptides via measurements of the disruption of the vesicle population under the conditions of continuous peptide dosing using a range of concentrations, and related the observed modes with the molecular activity mechanisms of these peptides. The study offers an effective approach for characterizing membrane-targeting antimicrobial agents in a standardized manner, and for assigning specific modes of action to the corresponding antimicrobial mechanisms.
- Open Access
- 1 July 2021
- Published by AIP Publishing in Biomicrofluidics
- Vol. 15 (4) , 041301
Standardizing characterization of membrane active peptides with microfluidics
Antimicrobial peptides (AMPs) are emerging as important players in the fight against antibiotic resistance. In parallel, the field of microfluidics has matured and its benefits are being exploited in applications of biomimetics and standardized testing. Membrane models are essential tools extensively utilized in studying the activity and modes of action of AMPs. Here, we describe how the utilization of microfluidic platforms in characterizing membrane active peptides can develop a reliable colorful image that classical techniques have rendered black and white.
- 1 July 2021
- Published by AIP Publishing in Biomicrofluidics
- Vol. 15 (4) , 041301
Open AccessStandardizing characterization of membrane active peptides with microfluidics
Antimicrobial peptides (AMPs) are emerging as important players in the fight against antibiotic resistance. In parallel, the field of microfluidics has matured and its benefits are being exploited in applications of biomimetics and standardized testing. Membrane models are essential tools extensively utilized in studying the activity and modes of action of AMPs. Here, we describe how the utilization of microfluidic platforms in characterizing membrane active peptides can develop a reliable colorful image that classical techniques have rendered black and white.