Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anne E. Staples has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Natural Aging of Biomaterials in Ambient and Physiological Environments

    by Shuyu Zhang, Anne E. Staples

    Biomaterials, generally defined as materials that interact with biological systems, are ubiquitous in the field of biomedical engineering. Biomaterials can undergo natural aging, in which changes in material properties occur in near‐ambient or near‐physiological environments without external acceleration. This can be either beneficial or harmful to the material or the tissue that interacts with the material. Such natural aging depends on material composition, temperature, pH, storage media composition, sterilization, and numerous other factors. This review focuses on studies investigating the natural aging of polymers, metals, ceramics, and nanomaterials, and their impact on material characteristics and functions as biomaterials.


  • Open Access

    Computational modelling of hollow fibre haemodialysers: current status and future directions

    by Ruhit Sinha, Anne E. Staples

    Current in silico dialyser models remain accurate only under narrowly constrained conditions. Advances in computing power and increasing levels of interdisciplinary collaboration, however, now set the stage for more robust computational haemodialyser models. In this review, we survey existing modelling approaches-long used to guide haemodialyser design and clinical nephrology practice-identify key unresolved challenges, and propose computational strategies poised to accelerate the development of dialyser technologies that better meet the needs of kidney failure patients.


  • Open Access

    Effects of natural aging on hydrophilicity and mechanical properties of PDMS in various storage environments

    by Shuyu Zhang, Anne E. Staples

    Polydimethylsiloxane (PDMS) is a synthetic elastomer widely used in biomedical and industrial applications. Despite its widespread use, the natural evolution of its mechanical and surface properties over time remains poorly understood. In this study, we fabricated PDMS samples with base-to-curing agent mixing ratios from 5:1 to 30:1 and aged them for up to 8 weeks under six non-harsh conditions at room temperature. Contact angle measurements revealed increasing hydrophobicity with aging, with maximum increases up to 16.5°. Mechanical testing showed up to 130% increases in Young’s modulus and 60% changes in flexibility after 5 weeks. Storage in mineral oil best preserved surface hydrophilicity, while storage in water best maintained mechanical integrity. These results provide a framework for optimizing PDMS storage conditions in microfluidic and biomedical device applications.


  • Mechanisms of insect respiration

    by Saadbin Khan, Anne E. Staples


  • Open Access

    Left-right tympanal size asymmetry in the parasitoid fly Ormia ochracea

    by Max R. Mikel-Stites, Paul E. Marek, Madeleine E. Hellier, Anne E. Staples

    Ormia ochracea is a parasitoid fly notable for its impressive hearing abilities relative to its small size. Here, we use it as a model organism to investigate if minor size differences in paired sensory organs may be beneficial or neutral to an organism's perception abilities. We took high-resolution images of tympanal organs from 21 O. ochracea specimens and found a statistically significant surface area asymmetry (up to 6.88%) between the left and right membranes. Numerical experiments indicated that peak values of key sound localization variables increased with increasing tympanal asymmetry, which may explain features of the limited available physiological data.

  • Open Access

    Design and characterization of 3D-printed hollow microneedle arrays for transdermal insulin delivery

    by Shuyu Zhang, Jenna Sims, Isabelle Mehochko, Ryan Zolovick, Tyler Kwak, Anne Staples

    The delivery of insulin to diabetic patients remains a challenge due to the limitations of current insulin delivery paradigms, including painful cannula insertion, potential infections, interference with activity, embarrassment, and sometimes cost. To address this problem, we designed and fabricated nine prototypes of stereolithographic 3D-printed microneedle arrays (MNAs) appropriate for the minimally invasive delivery of insulin. We characterized their transdermal penetration performance by delivering fluid at a constant rate to porcine skin through these MNAs. Moreover, we characterized the force required for these MNAs to puncture porcine skin using a mechanical testing apparatus. We developed an improved method of mechanical testing for the MNAs against porcine skin by incorporating an imitation soft tissue layer under the skin and compared the MNA results with those using a single microneedle and a hypodermic needle. In addition, we investigated the mechanical flexural strength of the MNAs by performing a flexural failure load test on them. We confirmed that the prototype MNAs are mechanically robust and do not fracture during skin penetration, setting the stage for future trials in vitro and in vivo. The final, optimized designs are freely available in stereolithography (STL) file format.


  • Open Access

    Microfluidic-based systems for the management of diabetes

    by Shuyu Zhang, Anne E. Staples

    Diabetes currently affects approximately 500 million people worldwide and is one of the most common causes of mortality in the United States. To diagnose and monitor diabetes, finger-prick blood glucose testing has long been used as the clinical gold standard. For diabetes treatment, insulin is typically delivered subcutaneously through cannula-based syringes, pens, or pumps in almost all type 1 diabetic (T1D) patients and some type 2 diabetic (T2D) patients. These painful, invasive approaches can cause non-adherence to glucose testing and insulin therapy. To address these problems, researchers have developed miniaturized blood glucose testing devices as well as microfluidic platforms for non-invasive glucose testing through other body fluids. In addition, glycated hemoglobin (HbA1c), insulin levels, and cellular biomechanics-related metrics have also been considered for microfluidic-based diabetes diagnosis. For the treatment of diabetes, insulin has been delivered transdermally through microdevices, mostly through microneedle array-based, minimally invasive injections. Researchers have also developed microfluidic platforms for oral, intraperitoneal, and inhalation-based delivery of insulin. For T2D patients, metformin, glucagon-like peptide 1 (GLP-1), and GLP-1 receptor agonists have also been delivered using microfluidic technologies. Thus far, clinical studies have been widely performed on microfluidic-based diabetes monitoring, especially glucose sensing, yet technologies for the delivery of insulin and other drugs to diabetic patients with microfluidics are still mostly in the preclinical stage. This article provides a concise review of the role of microfluidic devices in the diagnosis and monitoring of diabetes, as well as the delivery of pharmaceuticals to treat diabetes using microfluidic technologies in the recent literature. Graphical abstract


  • Accelerated evolution of Burgers' turbulence with coarse projective integration and deep learning

    by Mrigank Dhingra, Omer San, Anne E. Staples

    The evolution of a turbulent flow to a statistically steady state can be cast as a multiscale problem involving energy redistribution processes that take place on the long, large eddy turnover timescale and chaotic processes that take place on the much shorter timescale of the turbulence fluctuations. But the absence of a way to perform super-resolution reconstructions of the instantaneous velocity field from its lower-dimensional moments has prevented the use of standard multiscale computational approaches for accelerating turbulence simulations. We introduce an encoder-decoder recurrent neural network model, an architecture typically used in natural language processing, for translating between the instantaneous velocity field and energy spectrum in a one-dimensional turbulent flow. We use the model in a multiscale simulation scheme to evolve the stochastic Burgers' equation and recover the final, statistically stationary turbulent Burgers' velocity field up to 443 times faster in wall-clock time than using direct numerical simulation alone.

  • Open Access

    Reconsidering tympanal-acoustic interactions leads to an improved model of auditory acuity in a parasitoid fly

    by Max R Mikel-Stites, Mary K Salcedo, John J Socha, Paul E Marek, Anne E Staples

    Although most binaural organisms locate sound sources using neurological structures to amplify the sounds they hear, some animals use mechanically coupled hearing organs instead. One of these animals, the parasitoid fly Ormia ochracea (O. ochracea), has astoundingly accurate sound localization abilities. It can locate objects in the azimuthal plane with a precision of 2°, equal to that of humans, despite an intertympanal distance of only 0.5 mm, which is less than 1 / 100 th of the wavelength of the sound emitted by the crickets that it parasitizes. O. ochracea accomplishes this feat via mechanically coupled tympana that interact with incoming acoustic pressure waves to amplify differences in the signals received at the two ears. In 1995, Miles et al developed a model of hearing mechanics in O. ochracea that represents the tympana as flat, front-facing prosternal membranes, though they lie on a convex surface at an angle from the flies’ frontal and transverse planes. The model works well for incoming sound angles less than ± 30 ∘ but suffers from reduced accuracy (up to 60% error) at higher angles compared to response data acquired from O. ochracea specimens. Despite this limitation, it has been the basis for bio-inspired microphone designs for decades. Here, we present critical improvements to this classic hearing model based on information from three-dimensional reconstructions of O. ochracea’s tympanal organ. We identified the orientation of the tympana with respect to a frontal plane and the azimuthal angle segment between the tympana as morphological features essential to the flies’ auditory acuity, and hypothesized a differentiated mechanical response to incoming sound on the ipsi- and contralateral sides that depend on these features. We incorporated spatially-varying model coefficients representing this asymmetric response, making a new quasi-two-dimensional (q2D) model. The q2D model has high accuracy (average errors of under 10%) for all incoming sound angles. This improved biomechanical model may inform the design of new microscale directional microphones and other small-scale acoustic sensor systems.


  • Open Access

    A biologically accurate model of directional hearing in the parasitoid fly Ormia ochracea

    by Max R. Mikel-Stites, Mary K. Salcedo, John J. Socha, Paul E. Marek, Anne E. Staples

    This manuscript was compiled on October 5, 2021 Although most binaural organisms localize sound sources using neurological structures to amplify the sounds they hear, some animals use mechanically coupled hearing organs instead. One of these animals, the parasitoid fly Ormia ochracea, has astoundingly accurate sound localization abilities and can locate objects in the azimuthal plane with a precision of 2°, equal to that of humans. This is accomplished despite an intertympanal distance of only 0.5 mm, which is less than 1/100th of the wavelength of the sound emitted by the crickets that it parasitizes. In 1995, Miles et al. developed a model of hearing mechanics in O. ochracea, which works well for incoming sound angles of less than ±30°, but suffers from reduced accuracy (up to 60% error) at higher angles. Even with this limitation, it has served as the basis for multiple bio-inspired microphone designs for decades. Here, we present critical improvements to the classic O. ochracea hearing model based on information from 3D reconstructions of O. ochracea’s tympana. The 3D images reveal that the tympanal organ has curved lateral faces in addition to the flat front-facing prosternal membranes represented in the Miles model. To mimic these faces, we incorporated spatially-varying spring and damper coefficients that respond asymmetrically to incident sound waves, making a new quasi-two-dimensional (q2D) model. The q2D model has high accuracy (average errors of less than 10%) for the entire range of incoming sound angles. This improved biomechanical hearing model can inform the development of new technologies and may help to play a key role in developing improved hearing aids. Significance Statement: The ability to identify the location of sound sources is critical to organismal survival and for technologies that minimize unwanted background noise, such as directional microphones for hearing aids. Because of its exceptional auditory system, the parasitoid fly Ormia ochracea has served as an important model for binaural hearing and a source of bioinspiration for building tiny directional microphones with outsized sound localization abilities. Here, we performed 3D imaging of the fly’s tympanal organs and used the morphological information to improve the current model for hearing in O. ochracea. This model greatly expands the range of biological accuracy from ±30° to all incoming sound angles, providing a new avenue for studies of binaural hearing and further inspiration for fly-inspired technologies.