Mikhail Andreev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mikhail Andreev has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Aleksey Suvorov
School of Energy & Power Engineering, National Research Tomsk Polytechnic University, Tomsk 634050, Russia
20 shared publications - Nikolay Ruban
School of Energy & Power Engineering, National Research Tomsk Polytechnic University, Tomsk 634050, Russia
15 shared publications - Alisher Askarov
National Research Tomsk Polytechnic University
13 shared publications - Руслан Александрович Уфа
National Research Tomsk Polytechnic University, Tomsk, Russia
11 shared publications - Almaz O. Sulaymanov
Institute of Power Engineering, Tomsk Polytechnic University, Tomsk, Russia
9 shared publications - Anton Kievets
National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
9 shared publications
Latest Publications
- 1 November 2023
- Published by Springer Nature in Power Technology and Engineering
- Vol. 57 (4) , 637-649
Technology for Determining the Operational Settings of Remote Protection of Electric Transmission Lines Using Mathematical Models
- 1 November 2023
- Published by Springer Nature in Power Technology and Engineering
- Vol. 57 (4) , 637-649
Technology for Determining the Operational Settings of Remote Protection of Electric Transmission Lines Using Mathematical Models
- Open Access
Turbine Fast Valving Setting Method Based on the Hybrid Simulation Approach
Turbine fast valving is one way to preserve the stability of power systems in case of emergency excess power. The determination of optimal setting parameters of turbine fast valving is a rather complicated task. It is connected with the necessity to determine the parameters of an electrical signal, which controls by means of an amplifier the position of control valves and, accordingly, the value of the output turbine power. The amplitude, duration, as well as the form of the electric signal influence the speed and depth of turbine unloading; they also determine the character of transient process development, including in the post-emergency mode. The proposed approach differs from the currently used one in that the optimal electrical signal shape is selected by multiple detailed modelling in power system simulators, rather than one of three to five initial settings determined at the turbine manufacturer without taking into account the response of the power system. Thus, when using complete and reliable information regarding the processes in the turbine and generator equipment, its control systems, and the power system as a whole, it becomes possible to form the necessary shape of an electrical signal in the event of losing stability in a place of interest in the power system due to the occurrence of an emergency excess of generated active power of various values. The developed approach was tested, and the results of the study were verified by the field data.
Open AccessTurbine Fast Valving Setting Method Based on the Hybrid Simulation Approach
Turbine fast valving is one way to preserve the stability of power systems in case of emergency excess power. The determination of optimal setting parameters of turbine fast valving is a rather complicated task. It is connected with the necessity to determine the parameters of an electrical signal, which controls by means of an amplifier the position of control valves and, accordingly, the value of the output turbine power. The amplitude, duration, as well as the form of the electric signal influence the speed and depth of turbine unloading; they also determine the character of transient process development, including in the post-emergency mode. The proposed approach differs from the currently used one in that the optimal electrical signal shape is selected by multiple detailed modelling in power system simulators, rather than one of three to five initial settings determined at the turbine manufacturer without taking into account the response of the power system. Thus, when using complete and reliable information regarding the processes in the turbine and generator equipment, its control systems, and the power system as a whole, it becomes possible to form the necessary shape of an electrical signal in the event of losing stability in a place of interest in the power system due to the occurrence of an emergency excess of generated active power of various values. The developed approach was tested, and the results of the study were verified by the field data.
- Open Access
- 8 October 2022
- Published by Irkutsk National Research Technical University in iPolytech Journal
- Vol. 26 (3) , 465-486
Operation of synthetic inertia units in electric power systems of various densities
This study is aimed at improving the efficiency of photovoltaic plants operated in the electric networks of various densities by adjusting the synthetic inertia algorithm and automatic frequency control circuits. To this end, the automatic control system of a photovoltaic plant was investigated using hybrid modelling methods in an all-mode online simulation complex of electric power systems. It was shown that the stability of photovoltaic power plants could be improved through the use of synthetic inertia. According to the conducted research, effective operation of this algorithm can be ensured by a correct determination of the bandwidth of automatic frequency control. Operation of this automatic frequency control circuit can lead to the oscillations of various frequencies during the installation of photovoltaic power plants in low-current electrical networks (electrical networks with the short circuit coefficient of less than 10 a.u.) and, subsequently, negatively affect the operability of the synthetic inertia algorithm. In addition, in high-current networks with an increased bandwidth of the automatic frequency control unit, the value of the network frequency reduction decreases (optimal bandwidth of 50 Hz). Conversely, in low-current networks, the automatic frequency control unit, under an increase in the bandwidth, decreases the response rate of the synthetic inertia algorithm, which leads to an increase in the frequency reduction value (optimal bandwidth of 0.3 Hz). Thus, the conducted investigations showed that the automatic frequency control circuit in the control system of a photovoltaic power plant can be used to alter the operation of the synthetic inertia algorithm. However, the nature of this effect depends on the electrical network density and can be both positive and negative. The effect observed in the tested power system was confirmed for a real-dimension power system.
- 8 October 2022
- Published by Irkutsk National Research Technical University in iPolytech Journal
- Vol. 26 (3) , 465-486
Open AccessOperation of synthetic inertia units in electric power systems of various densities
This study is aimed at improving the efficiency of photovoltaic plants operated in the electric networks of various densities by adjusting the synthetic inertia algorithm and automatic frequency control circuits. To this end, the automatic control system of a photovoltaic plant was investigated using hybrid modelling methods in an all-mode online simulation complex of electric power systems. It was shown that the stability of photovoltaic power plants could be improved through the use of synthetic inertia. According to the conducted research, effective operation of this algorithm can be ensured by a correct determination of the bandwidth of automatic frequency control. Operation of this automatic frequency control circuit can lead to the oscillations of various frequencies during the installation of photovoltaic power plants in low-current electrical networks (electrical networks with the short circuit coefficient of less than 10 a.u.) and, subsequently, negatively affect the operability of the synthetic inertia algorithm. In addition, in high-current networks with an increased bandwidth of the automatic frequency control unit, the value of the network frequency reduction decreases (optimal bandwidth of 50 Hz). Conversely, in low-current networks, the automatic frequency control unit, under an increase in the bandwidth, decreases the response rate of the synthetic inertia algorithm, which leads to an increase in the frequency reduction value (optimal bandwidth of 0.3 Hz). Thus, the conducted investigations showed that the automatic frequency control circuit in the control system of a photovoltaic power plant can be used to alter the operation of the synthetic inertia algorithm. However, the nature of this effect depends on the electrical network density and can be both positive and negative. The effect observed in the tested power system was confirmed for a real-dimension power system.
- 4 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1952-1962
Synchrophasor Assisted Power Swing Detection Scheme for Wind Integrated Transmission Network
Integration of wind-based renewable energy sources into long Extra High Voltage/Ultra High Voltage uncompensated/compensated power transmission network poses significant problems in terms of proper detection of power swings and effective discrimination between symmetrical faults and power swing situations. As the existing protection strategies are unable to detect the said circumstances, a novel technique, based on the difference between sending end and receiving end positive sequence currents angles of the transmission line, is proposed in this paper. The required data is collected with the help of Phasor Measurement Units placed on both sides of the line. The scheme results in effective discrimination between distinct faults and circumstances of asymmetrical/symmetrical power swing and achieves satisfactory outcome during current transformer saturation condition. The proposed algorithm is evaluated on the wind-integrated IEEE-9 bus system by producing power swings, various cases of faults, and faults during power swings. Validation of the suggested technique was carried out by the execution of hardware-in-loop simulation on a Real-Time Digital Simulator. The achieved outcomes disclose higher sensitivity and better discriminating ability of the presented technique in comparison with those of numerous prevailing methods.
- 4 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1952-1962
Synchrophasor Assisted Power Swing Detection Scheme for Wind Integrated Transmission Network
Integration of wind-based renewable energy sources into long Extra High Voltage/Ultra High Voltage uncompensated/compensated power transmission network poses significant problems in terms of proper detection of power swings and effective discrimination between symmetrical faults and power swing situations. As the existing protection strategies are unable to detect the said circumstances, a novel technique, based on the difference between sending end and receiving end positive sequence currents angles of the transmission line, is proposed in this paper. The required data is collected with the help of Phasor Measurement Units placed on both sides of the line. The scheme results in effective discrimination between distinct faults and circumstances of asymmetrical/symmetrical power swing and achieves satisfactory outcome during current transformer saturation condition. The proposed algorithm is evaluated on the wind-integrated IEEE-9 bus system by producing power swings, various cases of faults, and faults during power swings. Validation of the suggested technique was carried out by the execution of hardware-in-loop simulation on a Real-Time Digital Simulator. The achieved outcomes disclose higher sensitivity and better discriminating ability of the presented technique in comparison with those of numerous prevailing methods.
- Open Access
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 65216-65233
Validation of Positive-Sequence Modeling of Large-Disturbance Stability in a Distribution Network With Distributed Generation Using the Hybrid Comprehensive Simulator
One of the general trends in power industry is the penetration of distributed generation (DG) units. The ongoing transformation of electric power systems (EPS) due to this penetration leads to a significant change in the properties of power systems. The problem arises in the ensuring stability of distribution system with DG units and EPS as a whole, especially in the case of large disturbances. The main way of solving this problem is positive-sequence phasor time-domain simulation. However, the known simplifications and limitations are inevitably applied at such simulation. In this regard, the obtained simulation results need to be validated. This paper proposes an alternative approach for validation of processes calculations, based on the use of a benchmark tool instead of field data. The hybrid simulator is proposed to use as a benchmark tool, because such simulator allow to obtain comprehensive information about a single spectrum of wave, electromagnetic, electromechanical processes in power system in cases of different large disturbances. That makes possible to identify the impact of the applied simplifications and limitations in the positive-sequence simulation on the reliability of power system stability assessment in the case of large disturbances. The studies presented in this paper were carried out using the scheme of distribution system with DG units, which is part of a real EPS. The obtained results demonstrate the arising errors in stability calculations, the nature of their changing and causes of occurrence, as well as factors affecting them.
- 28 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 65216-65233
Open AccessValidation of Positive-Sequence Modeling of Large-Disturbance Stability in a Distribution Network With Distributed Generation Using the Hybrid Comprehensive Simulator
One of the general trends in power industry is the penetration of distributed generation (DG) units. The ongoing transformation of electric power systems (EPS) due to this penetration leads to a significant change in the properties of power systems. The problem arises in the ensuring stability of distribution system with DG units and EPS as a whole, especially in the case of large disturbances. The main way of solving this problem is positive-sequence phasor time-domain simulation. However, the known simplifications and limitations are inevitably applied at such simulation. In this regard, the obtained simulation results need to be validated. This paper proposes an alternative approach for validation of processes calculations, based on the use of a benchmark tool instead of field data. The hybrid simulator is proposed to use as a benchmark tool, because such simulator allow to obtain comprehensive information about a single spectrum of wave, electromagnetic, electromechanical processes in power system in cases of different large disturbances. That makes possible to identify the impact of the applied simplifications and limitations in the positive-sequence simulation on the reliability of power system stability assessment in the case of large disturbances. The studies presented in this paper were carried out using the scheme of distribution system with DG units, which is part of a real EPS. The obtained results demonstrate the arising errors in stability calculations, the nature of their changing and causes of occurrence, as well as factors affecting them.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 3840-3848
Software and Hardware Decision Support System for Operators of Electrical Power Systems
The transience and unpredictability of processes in electric power systems (EPS) determine complexity of its control. This problem is especially relevant for EPS with renewable energy sources and flexible alternating current transmission systems technologies. Automatic control systems simplify the solution of this problem. Despite this, many issues related to EPS state control are solved by power system operators. Decision support systems (DSS) are applying to increase efficiency of operators work. However, existing algorithms in practice are inoperable in some cases: unrealizable decisions are formed, or decision cannot be found at all, etc. Another important problem is impossibility to preliminarily verify the proposed solution. In this regard, operators can additionally use EPS simulators, which are usually limited either by the size of simulated scheme or by the details of equipment mathematical models. The limitations are a consequence of numerical methods using, which are badly applicable for large-scale power systems simulation. In this article, a novel DSS has been developed based on a hybrid approach to EPS modeling combining properties and capabilities of several simulation techniques: analog, physical and digital. The implicit integration of differential equations in analog way makes possible modeling faster than real time. Such opportunity allows operator to verify more decisions and select the most effective ones. The algorithm for DSS application has been developed and described in the article. The properties and capabilities of the developed DSS are confirmed by experimental studies and tests in a real EPS.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 3840-3848
Software and Hardware Decision Support System for Operators of Electrical Power Systems
The transience and unpredictability of processes in electric power systems (EPS) determine complexity of its control. This problem is especially relevant for EPS with renewable energy sources and flexible alternating current transmission systems technologies. Automatic control systems simplify the solution of this problem. Despite this, many issues related to EPS state control are solved by power system operators. Decision support systems (DSS) are applying to increase efficiency of operators work. However, existing algorithms in practice are inoperable in some cases: unrealizable decisions are formed, or decision cannot be found at all, etc. Another important problem is impossibility to preliminarily verify the proposed solution. In this regard, operators can additionally use EPS simulators, which are usually limited either by the size of simulated scheme or by the details of equipment mathematical models. The limitations are a consequence of numerical methods using, which are badly applicable for large-scale power systems simulation. In this article, a novel DSS has been developed based on a hybrid approach to EPS modeling combining properties and capabilities of several simulation techniques: analog, physical and digital. The implicit integration of differential equations in analog way makes possible modeling faster than real time. Such opportunity allows operator to verify more decisions and select the most effective ones. The algorithm for DSS application has been developed and described in the article. The properties and capabilities of the developed DSS are confirmed by experimental studies and tests in a real EPS.
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (6) , 140-143
Relay Protection Settings Determination Using Its Mathematical Models
The correct functioning of relay protection (RP) largely determines the stability of electric power systems (EPS). The key point, which in turn determines the behavior of protection in various emergency modes, is their setting. The existing methods and means often do not allow to guarantee the adequacy of protection setting to the real operating conditions, which is confirmed by the statistics of accidents in the EPS. The root cause of this problem is the impossibility using the software tools used in practice for relay settings calculation to reliably reproduce the transient processes in the power system. The EPS simulator - Hybrid Real-Time Power System Simulator (HRTSim), developed by the authors, allows to adequately reproduce the entire spectrum of normal and emergency processes for a power system of any dimension, topology and configuration through the use of detailed three-phase models of all EPS elements. Given this possibility, the task of detailed modeling of relay protection, including instrumental current and voltage transformers, becomes promising. The developed protection modeling tools in combination with the capabilities of the HRTSim allow the development of new methods for determining the relay protection settings. This article presents an algorithm for determining the polygonal and circular tripping characteristics of distance protection, and also presents graphic materials demonstrating the operation of this algorithm. This approach allows to adapt the settings to the real conditions of protection application in the power system, while minimizing the likelihood of their incorrect behavior.
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (6) , 140-143
Relay Protection Settings Determination Using Its Mathematical Models
The correct functioning of relay protection (RP) largely determines the stability of electric power systems (EPS). The key point, which in turn determines the behavior of protection in various emergency modes, is their setting. The existing methods and means often do not allow to guarantee the adequacy of protection setting to the real operating conditions, which is confirmed by the statistics of accidents in the EPS. The root cause of this problem is the impossibility using the software tools used in practice for relay settings calculation to reliably reproduce the transient processes in the power system. The EPS simulator - Hybrid Real-Time Power System Simulator (HRTSim), developed by the authors, allows to adequately reproduce the entire spectrum of normal and emergency processes for a power system of any dimension, topology and configuration through the use of detailed three-phase models of all EPS elements. Given this possibility, the task of detailed modeling of relay protection, including instrumental current and voltage transformers, becomes promising. The developed protection modeling tools in combination with the capabilities of the HRTSim allow the development of new methods for determining the relay protection settings. This article presents an algorithm for determining the polygonal and circular tripping characteristics of distance protection, and also presents graphic materials demonstrating the operation of this algorithm. This approach allows to adapt the settings to the real conditions of protection application in the power system, while minimizing the likelihood of their incorrect behavior.
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (6) , 136-139
Validation of aperiodic and oscillatory stability calculations in a practical power systems
The stability of electric power systems is one of its most important properties. This article discusses small-disturbance rotor angle stability: aperiodic and oscillatory. The authors consider, typically for stability analysis, the numerical integration methods by modeling in known numerous digital software simulation tools and propose a method for validating of simulation results by benchmark tool instead of field data. The feasibility of the proposed approach is clearly illustrated by the given fragments of the corresponding experimental studies.
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (6) , 136-139
Validation of aperiodic and oscillatory stability calculations in a practical power systems
The stability of electric power systems is one of its most important properties. This article discusses small-disturbance rotor angle stability: aperiodic and oscillatory. The authors consider, typically for stability analysis, the numerical integration methods by modeling in known numerous digital software simulation tools and propose a method for validating of simulation results by benchmark tool instead of field data. The feasibility of the proposed approach is clearly illustrated by the given fragments of the corresponding experimental studies.
- Open Access
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 174860-174870
Research, Development and Application of Hybrid Model of Back-to-Back HVDC Link
Recent hybrid simulators (or co-simulators) of the electric power system are focused on scientific and research features to propose and develop novel and more accurate simulators. The present paper demonstrates one more hybrid modelling approach based on application and combination of three modeling approaches all together: physical, analog and digital. The primary focus of the proposed approach is to develop the simulation tool ensuring such vital characteristics as three-phase simulation and modeling of a single spectrum of processes in electric power system, without separation of the electromagnetic and electromechanical transient stages. Moreover, unlimited scalability of the electric power system model and real-time simulation to ensure the opportunity of data exchange with external devices have been considered. The description of the development of the hybrid model of back-to-back HVDC link based on the proposed approach is discussed and analyzed. To confirm properties of the mentioned hybrid simulation approach and hybrid model of back-to-back HVDC link, the simulation results of the interconnection of non-synchronously operating parts of the electric power system; power flow regulation; dynamic response to external fault and damping of power oscillation in electric power system are presented and examined. Moreover, to confirm the adequacy of the obtained results, the comparison with a detailed voltage source converter HVDC model (Simulink Matlab) and Eurostag software are introduced.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 174860-174870
Open AccessResearch, Development and Application of Hybrid Model of Back-to-Back HVDC Link
Recent hybrid simulators (or co-simulators) of the electric power system are focused on scientific and research features to propose and develop novel and more accurate simulators. The present paper demonstrates one more hybrid modelling approach based on application and combination of three modeling approaches all together: physical, analog and digital. The primary focus of the proposed approach is to develop the simulation tool ensuring such vital characteristics as three-phase simulation and modeling of a single spectrum of processes in electric power system, without separation of the electromagnetic and electromechanical transient stages. Moreover, unlimited scalability of the electric power system model and real-time simulation to ensure the opportunity of data exchange with external devices have been considered. The description of the development of the hybrid model of back-to-back HVDC link based on the proposed approach is discussed and analyzed. To confirm properties of the mentioned hybrid simulation approach and hybrid model of back-to-back HVDC link, the simulation results of the interconnection of non-synchronously operating parts of the electric power system; power flow regulation; dynamic response to external fault and damping of power oscillation in electric power system are presented and examined. Moreover, to confirm the adequacy of the obtained results, the comparison with a detailed voltage source converter HVDC model (Simulink Matlab) and Eurostag software are introduced.
- Open Access
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 136071-136091
Comprehensive Validation of Transient Stability Calculations in Electric Power Systems and Hardware-Software Tool for Its Implementation
Reliability and survivability of electric power systems (EPS) depend on transient stability assessment (TSA). One of the most effective way to TSA is time-domain simulation. However, large-scale EPS mathematical model contains a stiff nonlinear system of high-order differential equations. Such system cannot be solved analytically. At the same time, numerical methods are imperfectly applied for such system due to limitation conditions. To make it appropriate, the EPS mathematical model is simplified and additional limitations are used. These simplifications and limitations reduce reliability of simulation results. Consequently, their validation is needed. The most reliable approach to provide it is to compare the simulation results with the field data. However, in practice, there are not enough data for such validation. This paper proposes an alternative approach for validation – the application of a reference model instead of field data. A hardware-software system HRTSim was used as a reference model. This power system simulator has all the necessary properties and capabilities to obtain reliable information required for comprehensive validation of transient stability calculations in EPSs. Main disturbances leading to instability in EPSs are investigated to conduct the validation (processes in cases of faults, single-phase auto-reclosing operation and power system interconnection). Fragments of corresponding experimental studies illustrate the efficiency of the proposed approach. Obtained results confirmed the possibility of the developed approach to identify the causes of numerical calculation errors and to determine disturbances calculated with the significant error. In addition, experimental studies have revealed that numerical calculations error depends on disturbances intensity.
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 136071-136091
Open AccessComprehensive Validation of Transient Stability Calculations in Electric Power Systems and Hardware-Software Tool for Its Implementation
Reliability and survivability of electric power systems (EPS) depend on transient stability assessment (TSA). One of the most effective way to TSA is time-domain simulation. However, large-scale EPS mathematical model contains a stiff nonlinear system of high-order differential equations. Such system cannot be solved analytically. At the same time, numerical methods are imperfectly applied for such system due to limitation conditions. To make it appropriate, the EPS mathematical model is simplified and additional limitations are used. These simplifications and limitations reduce reliability of simulation results. Consequently, their validation is needed. The most reliable approach to provide it is to compare the simulation results with the field data. However, in practice, there are not enough data for such validation. This paper proposes an alternative approach for validation – the application of a reference model instead of field data. A hardware-software system HRTSim was used as a reference model. This power system simulator has all the necessary properties and capabilities to obtain reliable information required for comprehensive validation of transient stability calculations in EPSs. Main disturbances leading to instability in EPSs are investigated to conduct the validation (processes in cases of faults, single-phase auto-reclosing operation and power system interconnection). Fragments of corresponding experimental studies illustrate the efficiency of the proposed approach. Obtained results confirmed the possibility of the developed approach to identify the causes of numerical calculation errors and to determine disturbances calculated with the significant error. In addition, experimental studies have revealed that numerical calculations error depends on disturbances intensity.