Henning U. Voss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Henning U. Voss has a total of 166 co-authors. Here are the top co-authors by number of shared publications:
- Douglas Ballon
Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
6 shared publications - Andrei I. Holodny
Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
3 shared publications Bruce D. McCandliss
Sackler Institute for Developmental Psychobiology, Weill Medical College of Cornell University, New York, USA
3 shared publicationsDouglas J. Ballon
Weill Cornell Medicine
3 shared publications- Nicholas D. Schiff
Feil Family Brain and Mind Research Institute, Weill Cornell Medical College
3 shared publications - Ronny Ramlau
Johannes Kepler University Linz
3 shared publications
Latest Publications
- Open Access
Brief visual oddball events evoke CSF flow in the spinal canal
The measurement of cerebrospinal fluid (CSF) flow with fMRI, made possible by exploiting edge artifacts of spin saturation when the bottom acquisition slice lies in a CSF reservoir, allows researchers to investigate an aspect of brain health that has been increasingly linked to cognitive aging and neurodegenerative disease via its role in glymphatic clearance. The initial demonstration of this technique used the fourth ventricle, but recent reports show it can also be done when the bottom acquisition slice lies in the spinal canal in the foramen magnum. We present a method to automatically identify the spinal canal without manual tracing, and measure CSF flow with high confidence using multi-echo acquisition to separate out BOLD-like and non-BOLD-like signal components, along with physiological regression to improve signal to noise ratio. Using these methods we found that CSF flow correlated with decreases in BOLD activity in 70 adults aged 19-76. We further found that brief, infrequent salient stimuli (visual oddballs, requiring a button press) were capable of provoking measurable CSF flow.
Open AccessBrief visual oddball events evoke CSF flow in the spinal canal
The measurement of cerebrospinal fluid (CSF) flow with fMRI, made possible by exploiting edge artifacts of spin saturation when the bottom acquisition slice lies in a CSF reservoir, allows researchers to investigate an aspect of brain health that has been increasingly linked to cognitive aging and neurodegenerative disease via its role in glymphatic clearance. The initial demonstration of this technique used the fourth ventricle, but recent reports show it can also be done when the bottom acquisition slice lies in the spinal canal in the foramen magnum. We present a method to automatically identify the spinal canal without manual tracing, and measure CSF flow with high confidence using multi-echo acquisition to separate out BOLD-like and non-BOLD-like signal components, along with physiological regression to improve signal to noise ratio. Using these methods we found that CSF flow correlated with decreases in BOLD activity in 70 adults aged 19-76. We further found that brief, infrequent salient stimuli (visual oddballs, requiring a button press) were capable of provoking measurable CSF flow.
- Open Access
Age-related changes of the brain’s arterial network assessed with machine learning segmentation
Purpose: To provide a tool for the automatic segmentation of an arteriogram of the brain from MRA images and the estimation of arterial tortuosity as a summary marker. Methods: A deep learning model was trained and validated on a previously published set of semi-automatically segmented brain arteriograms. We tested whether arterial tortuosity estimated from a large number of age-representative subjects (N = 478) would reproduce previously published statistics of increasing tortuosity with age. Results: The tool provides a segmentation of the arteriograms from MRA images of varying resolution and quality. The arterial tortuosity estimated from the automatically segmented brain arteriograms approximately matched their previously published statistics. Further, a highly significant increase of tortuosity with age was observed in the large dataset with 478 subjects (p = 9 ×10 -8 ). Discussion and conclusion: The proposed ASN (Angiogram Segmentation Network) algorithm can provide the radiologist with a clean arteriogram of the brain, without the need for manual segmentation by the MR operator. Moreover, it offers arterial tortuosity as an instant quantitative metric that can augment the qualitative visual reading of the MRA.
Open AccessAge-related changes of the brain’s arterial network assessed with machine learning segmentation
Purpose: To provide a tool for the automatic segmentation of an arteriogram of the brain from MRA images and the estimation of arterial tortuosity as a summary marker. Methods: A deep learning model was trained and validated on a previously published set of semi-automatically segmented brain arteriograms. We tested whether arterial tortuosity estimated from a large number of age-representative subjects (N = 478) would reproduce previously published statistics of increasing tortuosity with age. Results: The tool provides a segmentation of the arteriograms from MRA images of varying resolution and quality. The arterial tortuosity estimated from the automatically segmented brain arteriograms approximately matched their previously published statistics. Further, a highly significant increase of tortuosity with age was observed in the large dataset with 478 subjects (p = 9 ×10 -8 ). Discussion and conclusion: The proposed ASN (Angiogram Segmentation Network) algorithm can provide the radiologist with a clean arteriogram of the brain, without the need for manual segmentation by the MR operator. Moreover, it offers arterial tortuosity as an instant quantitative metric that can augment the qualitative visual reading of the MRA.
- Open Access
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135730-135745
MRI Denoising Using Pixel-Wise Threshold Selection
Magnetic resonance imaging (MRI) has emerged as a promising technique for non-invasive medical imaging. The primary challenge in MRI is the trade-off between image visual quality and acquisition time. Current MRI image denoising algorithms employ global thresholding to denoise the whole image, which leads to inadequate denoising or image distortion. This study introduces a novel pixel-wise (localized) thresholding approach of singular vectors, obtained from singular value decomposition, to denoise magnetic resonance (MR) images. The pixel-wise thresholding of singular vectors is performed using separate singular values as thresholds at each pixel, which is advantageous given the spatial noise variation throughout the image. The method presented is validated on MR images of a standard phantom approved by the magnetic resonance accreditation program (MRAP). The denoised images display superior visual quality and recover minute structural information otherwise suppressed in the noisy image. The increase in peak-signal-to-noise-ratio (PSNR) and contrast-to-noise-ratio (CNR) values of $\ge 18\%$ and $\ge 200\%$ of the denoised images, respectively, imply efficient noise removal and visual quality enhancement. The structural similarity index (SSIM) of $\ge 0.95$ for denoised images indicates that the crucial structural information is recovered through the presented method. A comparison with the standard filtering methods widely used for MRI denoising establishes the superior performance of the presented method. The presented pixel-wise denoising technique reduces the scan time by 2-3 times and has the potential to be integrated into any MRI system to obtain faster and better quality images.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135730-135745
Open AccessMRI Denoising Using Pixel-Wise Threshold Selection
Magnetic resonance imaging (MRI) has emerged as a promising technique for non-invasive medical imaging. The primary challenge in MRI is the trade-off between image visual quality and acquisition time. Current MRI image denoising algorithms employ global thresholding to denoise the whole image, which leads to inadequate denoising or image distortion. This study introduces a novel pixel-wise (localized) thresholding approach of singular vectors, obtained from singular value decomposition, to denoise magnetic resonance (MR) images. The pixel-wise thresholding of singular vectors is performed using separate singular values as thresholds at each pixel, which is advantageous given the spatial noise variation throughout the image. The method presented is validated on MR images of a standard phantom approved by the magnetic resonance accreditation program (MRAP). The denoised images display superior visual quality and recover minute structural information otherwise suppressed in the noisy image. The increase in peak-signal-to-noise-ratio (PSNR) and contrast-to-noise-ratio (CNR) values of $\ge 18\%$ and $\ge 200\%$ of the denoised images, respectively, imply efficient noise removal and visual quality enhancement. The structural similarity index (SSIM) of $\ge 0.95$ for denoised images indicates that the crucial structural information is recovered through the presented method. A comparison with the standard filtering methods widely used for MRI denoising establishes the superior performance of the presented method. The presented pixel-wise denoising technique reduces the scan time by 2-3 times and has the potential to be integrated into any MRI system to obtain faster and better quality images.
- Open Access
- 12 August 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (3) , L032035
Moiré patterns of space-filling curves
It is shown on the examples of Moore and Gosper curves that two spatially shifted or twisted, preasymptotic space-filling curves can produce large-scale superstructures akin to moiré patterns. To study physical phenomena emerging from these patterns, a geometrical coupling coefficient based on the Neumann integral is introduced. It is found that moiré patterns appear most defined at the peaks of those coefficients. A physical interpretation of these coefficients as a measure for inductive coupling between radiofrequency resonators leads to a design principle for strongly overlapping resonators with vanishing mutual inductance, which might be interesting for applications in MRI. These findings are demonstrated in graphical, numerical, and physical experiments. Published by the American Physical Society 2024
- 12 August 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (3) , L032035
Open AccessMoiré patterns of space-filling curves
It is shown on the examples of Moore and Gosper curves that two spatially shifted or twisted, preasymptotic space-filling curves can produce large-scale superstructures akin to moiré patterns. To study physical phenomena emerging from these patterns, a geometrical coupling coefficient based on the Neumann integral is introduced. It is found that moiré patterns appear most defined at the peaks of those coefficients. A physical interpretation of these coefficients as a measure for inductive coupling between radiofrequency resonators leads to a design principle for strongly overlapping resonators with vanishing mutual inductance, which might be interesting for applications in MRI. These findings are demonstrated in graphical, numerical, and physical experiments. Published by the American Physical Society 2024
- Open Access
- 9 March 2024
- Published by Elsevier in Aging Brain
- Vol. 5, 100111
Pulsatility analysis of the circle of Willis
- 9 March 2024
- Published by Elsevier in Aging Brain
- Vol. 5, 100111
Open AccessPulsatility analysis of the circle of Willis
- Open Access
Pulsatility analysis of the circle of Willis
Purpose: To evaluate the phenomenological significance of cerebral blood pulsatility imaging in aging research. Methods: N = 38 subjects aged from 20 to 72 years of age (24 females) were imaged with ultrafast MRI with a sampling rate of 100 ms and simultaneous acquisition of pulse oximetry data. Of these, 28 subjects had acceptable MRI and pulse data, with 16 subjects between 20 and 28 years of age, and 12 subjects between 61 and 72 years of age. Pulse amplitude in the circle of Willis was assessed with the recently developed method of analytic phase projection to extract blood volume waveforms with an effective sampling rate of about 0.3 ms. Results: Arteries in the circle of Willis showed pulsatility in the MRI for both the young and old age groups. Pulse amplitude in the circle of Willis significantly increased with age (p = 0.01) but was independent of gender, heart rate, and head motion during MRI. Discussion and conclusion: Increased pulse wave amplitude in the circle of Willis in the elderly suggests a phenomenological significance of cerebral blood pulsatility imaging in aging research. The physiologic origin of increased pulse amplitude (increased pulse pressure vs. change in arterial morphology vs. re-shaping of pulse waveforms caused by the heart) requires further investigation.
Open AccessPulsatility analysis of the circle of Willis
Purpose: To evaluate the phenomenological significance of cerebral blood pulsatility imaging in aging research. Methods: N = 38 subjects aged from 20 to 72 years of age (24 females) were imaged with ultrafast MRI with a sampling rate of 100 ms and simultaneous acquisition of pulse oximetry data. Of these, 28 subjects had acceptable MRI and pulse data, with 16 subjects between 20 and 28 years of age, and 12 subjects between 61 and 72 years of age. Pulse amplitude in the circle of Willis was assessed with the recently developed method of analytic phase projection to extract blood volume waveforms with an effective sampling rate of about 0.3 ms. Results: Arteries in the circle of Willis showed pulsatility in the MRI for both the young and old age groups. Pulse amplitude in the circle of Willis significantly increased with age (p = 0.01) but was independent of gender, heart rate, and head motion during MRI. Discussion and conclusion: Increased pulse wave amplitude in the circle of Willis in the elderly suggests a phenomenological significance of cerebral blood pulsatility imaging in aging research. The physiologic origin of increased pulse amplitude (increased pulse pressure vs. change in arterial morphology vs. re-shaping of pulse waveforms caused by the heart) requires further investigation.
- Open Access
- 1 November 2023
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 33 (11)
Machine discovery of partial differential equations from spatiotemporal data: A sparse Bayesian learning framework
This study presents a general framework, namely, Sparse Spatiotemporal System Discovery (S3d), for discovering dynamical models given by Partial Differential Equations (PDEs) from spatiotemporal data. S3d is built on the recent development of sparse Bayesian learning, which enforces sparsity in the estimated PDEs. This approach enables a balance between model complexity and fitting error with theoretical guarantees. The proposed framework integrates Bayesian inference and a sparse priori distribution with the sparse regression method. It also introduces a principled iterative re-weighted algorithm to select dominant features in PDEs and solve for the sparse coefficients. We have demonstrated the discovery of the complex Ginzburg–Landau equation from a traveling-wave convection experiment, as well as several other PDEs, including the important cases of Navier–Stokes and sine-Gordon equations, from simulated data.
- 1 November 2023
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 33 (11)
Open AccessMachine discovery of partial differential equations from spatiotemporal data: A sparse Bayesian learning framework
This study presents a general framework, namely, Sparse Spatiotemporal System Discovery (S3d), for discovering dynamical models given by Partial Differential Equations (PDEs) from spatiotemporal data. S3d is built on the recent development of sparse Bayesian learning, which enforces sparsity in the estimated PDEs. This approach enables a balance between model complexity and fitting error with theoretical guarantees. The proposed framework integrates Bayesian inference and a sparse priori distribution with the sparse regression method. It also introduces a principled iterative re-weighted algorithm to select dominant features in PDEs and solve for the sparse coefficients. We have demonstrated the discovery of the complex Ginzburg–Landau equation from a traveling-wave convection experiment, as well as several other PDEs, including the important cases of Navier–Stokes and sine-Gordon equations, from simulated data.
- Open Access
- 13 July 2022
- Published by Springer Nature in Research Square
Real-time motion amplification on mobile devices
A simple motion amplification algorithm suitable for real-time applications on mobile devices is presented. It is based on motion enhancement by moving average differencing (MEMAD), a temporal high-pass filter for video streams. MEMAD can amplify small moving objects or subtle motion in larger objects. It is computationally sufficiently simple to be implemented in real time on smartphones. In the specific implementation as an Android phone app, MEMAD is demonstrated on examples chosen such as to motivate applications in the engineering, biological, and medical sciences.
- 13 July 2022
- Published by Springer Nature in Research Square
Open AccessReal-time motion amplification on mobile devices
A simple motion amplification algorithm suitable for real-time applications on mobile devices is presented. It is based on motion enhancement by moving average differencing (MEMAD), a temporal high-pass filter for video streams. MEMAD can amplify small moving objects or subtle motion in larger objects. It is computationally sufficiently simple to be implemented in real time on smartphones. In the specific implementation as an Android phone app, MEMAD is demonstrated on examples chosen such as to motivate applications in the engineering, biological, and medical sciences.
- 1 January 2022
- Published by Elsevier in Behavioural Brain Research
- Vol. 416, 113534
The Direction of response selectivity between conspecific and heterospecific auditory stimuli varies with response metric
- 1 January 2022
- Published by Elsevier in Behavioural Brain Research
- Vol. 416, 113534
The Direction of response selectivity between conspecific and heterospecific auditory stimuli varies with response metric
- Open Access
- 1 January 2021
- Published by Elsevier in NeuroImage
- Vol. 225, 117494
On measuring head motion and effects of head molds during fMRI
- 1 January 2021
- Published by Elsevier in NeuroImage
- Vol. 225, 117494
Open AccessOn measuring head motion and effects of head molds during fMRI