Chantal Compere
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chantal Compere has a total of 874 co-authors. Here are the top co-authors by number of shared publications:
- Florent Colas
IFREMER / RDT, Centre de Brest, BP 70, 29280, Plouzané, France
13 shared publications - Hubert Perrot
Sorbonne Université, CNRS, LISE UMR8235, 75005 Paris, France
13 shared publications - Emmanuel Rinnert
Geo-Ocean, Unité Mixte de Recherche 6538 CNRS, Ifremer, UBO, UBS, Plouzané, France
10 shared publications - Juan Zuniga
IFIC - Instituto de Física Corpuscular (CSIC - Universitat de València), Catedrático José Beltrán, 2, 46980 Paterna, Valencia
10 shared publications - Juergen Brunner
Aix Marseille Univ, CNRS/IN2P3, CPPM, Marseille, France
10 shared publications - Domenico Lo Presti
University of Catania
9 shared publications
Latest Publications
- 2 March 2022
- Published by Taylor & Francis
- p. 211-222
Detection and Characterisation of Biofilms in Natural Seawater by Analysing Oxygen Diffusion under Controlled Hydrodynamic Conditions
The laboratories involved in this work have conducted experimental work on the analysis of oxygen mass transport for characterising the biofilm formed on passive metal electrodes. This technique is based on the analysis of the oxygen reduction current when a rotating disk electrode is polarised to a potential corresponding to the diffusion plateau of oxygen. The variation of the limiting current with time (in days) is due to the biofilm formation and hence to the modification of the mass transport properties through it. For the steady flow condition, a mathematical model is proposed and the agreement between experimental data and fitted curves is excellent. This fitting procedure gives a parameter that is proportional to the biofilm thickness over oxygen diffusion coefficient ratio (δf/Df). This experimental procedure conducted for different immersion times shows that it is possible to follow, in situ, the biofilm development on a gold electrode as well as on a stainless steel electrode immersed in natural seawater. The detection threshold is 24 h. After developing the basic theory, this paper presents the results for gold electrodes. The thickness of a biofilm developed in natural seawater has been calculated as well as the oxygen diffusion coefficient in the biofilm. The results are in agreement with the current knowledge on biofilm properties.
- 2 March 2022
- Published by Taylor & Francis
- p. 211-222
Detection and Characterisation of Biofilms in Natural Seawater by Analysing Oxygen Diffusion under Controlled Hydrodynamic Conditions
The laboratories involved in this work have conducted experimental work on the analysis of oxygen mass transport for characterising the biofilm formed on passive metal electrodes. This technique is based on the analysis of the oxygen reduction current when a rotating disk electrode is polarised to a potential corresponding to the diffusion plateau of oxygen. The variation of the limiting current with time (in days) is due to the biofilm formation and hence to the modification of the mass transport properties through it. For the steady flow condition, a mathematical model is proposed and the agreement between experimental data and fitted curves is excellent. This fitting procedure gives a parameter that is proportional to the biofilm thickness over oxygen diffusion coefficient ratio (δf/Df). This experimental procedure conducted for different immersion times shows that it is possible to follow, in situ, the biofilm development on a gold electrode as well as on a stainless steel electrode immersed in natural seawater. The detection threshold is 24 h. After developing the basic theory, this paper presents the results for gold electrodes. The thickness of a biofilm developed in natural seawater has been calculated as well as the oxygen diffusion coefficient in the biofilm. The results are in agreement with the current knowledge on biofilm properties.
- 29 November 2018
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 35 (12) , 3110-3115
Effect of plasmonic mode on plasmon-based lasers
For the last few years, plasmon-based lasers have been investigated theoretically and experimentally. Several configurations have been reported. They are composed of quantum emitters coupled to a plasmonic structure. In this paper, we investigate the effect of the plasmon mode on the far-field and near-field characteristics of a nanolaser composed by a periodic array of metallic nanoparticles covered by gain materials under optical pumping. Two configurations were investigated. The first structure supported a localized surface plasmon (LSP) mode, while the second a surface lattice plasmon (SLP) mode. This theoretical work relies on semi-quantum calculations based on a four-level gain molecule and a time-domain approach. We demonstrated that lasing in a SLP mode requires a lower concentration of quantum emitters and generates a higher far-field emission with a lower threshold than lasing in a LSP mode. At nanoscale, near-field enhancement at the emission wavelength and above the threshold is 2 orders of magnitude higher with the SLP than the LSP mode. Our results with a general character show that designing a plasmon-based laser that sustains the SLP mode will result in a better lasing efficiency than with a LSP mode.
- 29 November 2018
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 35 (12) , 3110-3115
Effect of plasmonic mode on plasmon-based lasers
For the last few years, plasmon-based lasers have been investigated theoretically and experimentally. Several configurations have been reported. They are composed of quantum emitters coupled to a plasmonic structure. In this paper, we investigate the effect of the plasmon mode on the far-field and near-field characteristics of a nanolaser composed by a periodic array of metallic nanoparticles covered by gain materials under optical pumping. Two configurations were investigated. The first structure supported a localized surface plasmon (LSP) mode, while the second a surface lattice plasmon (SLP) mode. This theoretical work relies on semi-quantum calculations based on a four-level gain molecule and a time-domain approach. We demonstrated that lasing in a SLP mode requires a lower concentration of quantum emitters and generates a higher far-field emission with a lower threshold than lasing in a LSP mode. At nanoscale, near-field enhancement at the emission wavelength and above the threshold is 2 orders of magnitude higher with the SLP than the LSP mode. Our results with a general character show that designing a plasmon-based laser that sustains the SLP mode will result in a better lasing efficiency than with a LSP mode.
- 16 May 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10231, 102310
Infrared sensor for water pollution and monitoring
Development of Mid-infrared sensors for the detection of biochemical molecules is a challenge of great importance. Mid-infrared range (4000 – 400 cm-1) contains the absorption bands related to the vibrations of organic molecules (nitrates, hydrocarbons, pesticides, etc.). Chalcogenide glasses are an important class of amorphous materials appropriate for sensing applications. Indeed, they are mainly studied and used for their wide transparency in the infrared range (up to 15 μm for selenide glasses) and high refractive index (between 2 and 3). The aim of this study is to synthesize and characterize chalcogenide thin films for developing mid-IR optical waveguides. Therefore, two (GeSe2)100-x(Sb2Se3)x chalcogenide glasses, where x=10 and 50 were chosen for their good mid-IR transparency, high stability against crystallization and their refractive index contrast suitable for mid-IR waveguiding. Chalcogenide glasses were prepared using the conventional melting and quenching method and then used for RF magnetron sputtering deposition. Sputtered thin films were characterized in order to determine dispersion of refractive index in UV-Vis-NIR-MIR. Obtained results were used for the simulation of the optical design in mid-infrared (λ = 7.7 μm). Selenide ridge waveguide were prepared by RIE-ICP dry etching process. Single-mode propagation at 7.7 μm was observed. Optical losses of 0.7 ± 0.3 and 2.5 ± 0.1 dB.cm-1 were measured in near-infrared (λ = 1.55 μm) and midinfrared (λ = 7.7 μm), respectively. Achieved results are promising for the fabrication of an integrated optical sensor operating in the mid-infrared. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 16 May 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10231, 102310
Infrared sensor for water pollution and monitoring
Development of Mid-infrared sensors for the detection of biochemical molecules is a challenge of great importance. Mid-infrared range (4000 – 400 cm-1) contains the absorption bands related to the vibrations of organic molecules (nitrates, hydrocarbons, pesticides, etc.). Chalcogenide glasses are an important class of amorphous materials appropriate for sensing applications. Indeed, they are mainly studied and used for their wide transparency in the infrared range (up to 15 μm for selenide glasses) and high refractive index (between 2 and 3). The aim of this study is to synthesize and characterize chalcogenide thin films for developing mid-IR optical waveguides. Therefore, two (GeSe2)100-x(Sb2Se3)x chalcogenide glasses, where x=10 and 50 were chosen for their good mid-IR transparency, high stability against crystallization and their refractive index contrast suitable for mid-IR waveguiding. Chalcogenide glasses were prepared using the conventional melting and quenching method and then used for RF magnetron sputtering deposition. Sputtered thin films were characterized in order to determine dispersion of refractive index in UV-Vis-NIR-MIR. Obtained results were used for the simulation of the optical design in mid-infrared (λ = 7.7 μm). Selenide ridge waveguide were prepared by RIE-ICP dry etching process. Single-mode propagation at 7.7 μm was observed. Optical losses of 0.7 ± 0.3 and 2.5 ± 0.1 dB.cm-1 were measured in near-infrared (λ = 1.55 μm) and midinfrared (λ = 7.7 μm), respectively. Achieved results are promising for the fabrication of an integrated optical sensor operating in the mid-infrared. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 12 April 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (15) , 13797-13807
In situ measurement with diffusive gradients in thin films: effect of biofouling in freshwater
Concerning in situ passive sampler deployment, several technical priorities must be considered. In particular, deployment time must be sufficiently long not only to allow a significant quantity to be accumulated to facilitate analysis but also to ensure that the signal is above the quantification limit and out of the blank influence. Moreover, regarding the diffusive gradient in thin films (DGT) technique, deployment time must also be sufficiently long (at least 5 days) to avoid the interactions of the solutes with the material diffusion layer of the DGT and for the steady state to be reached in the gel. However, biofouling occurs in situ and modifies the surface of the samplers. In this article, we propose a kinetic model which highlights the biofouling effect. This model was able to describe the mitigation of the flux towards the DGT resin observed on Cd, Co, Mn, Ni and Zn during a 22-day deployment in the Seine River. Over a period of 22 days, biofouling had a significant impact on the DGT concentrations measured, which were decreased twofold to threefold when compared to concentrations measured in unaffected DGTs.
- 12 April 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (15) , 13797-13807
In situ measurement with diffusive gradients in thin films: effect of biofouling in freshwater
Concerning in situ passive sampler deployment, several technical priorities must be considered. In particular, deployment time must be sufficiently long not only to allow a significant quantity to be accumulated to facilitate analysis but also to ensure that the signal is above the quantification limit and out of the blank influence. Moreover, regarding the diffusive gradient in thin films (DGT) technique, deployment time must also be sufficiently long (at least 5 days) to avoid the interactions of the solutes with the material diffusion layer of the DGT and for the steady state to be reached in the gel. However, biofouling occurs in situ and modifies the surface of the samplers. In this article, we propose a kinetic model which highlights the biofouling effect. This model was able to describe the mitigation of the flux towards the DGT resin observed on Cd, Co, Mn, Ni and Zn during a 22-day deployment in the Seine River. Over a period of 22 days, biofouling had a significant impact on the DGT concentrations measured, which were decreased twofold to threefold when compared to concentrations measured in unaffected DGTs.
- Open Access
- 31 March 2016
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 14 (7) , 456-465
A surface plasmon resonance system for the underwater detection of domoic acid
Over the past decade Surface Plasmon Resonance (SPR) techniques have been applied to the measurement of numerous analytes. In this article, an SPR biosensor system deployed from an oceanographic vessel was used to measure dissolved domoic acid (DA), a common and harmful phycotoxin produced by certain microalgae species belonging to the genus Pseudo‐nitzschia. During the biosensor deployment, concentrations of Pseudo‐nitzschia cells were very low over the study area and measured DA concentrations were below detection. However, the in situ operational detection limit of the system was established using calibrated seawater solutions spiked with DA. The system could detect the toxin at concentrations as low as 0.1 ng mL−1 and presented a linear dynamic range from 0.1 ng mL−1 to 2.0 ng mL−1. This sensor showed promise for in situ detection of DA.
- 31 March 2016
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 14 (7) , 456-465
Open AccessA surface plasmon resonance system for the underwater detection of domoic acid
Over the past decade Surface Plasmon Resonance (SPR) techniques have been applied to the measurement of numerous analytes. In this article, an SPR biosensor system deployed from an oceanographic vessel was used to measure dissolved domoic acid (DA), a common and harmful phycotoxin produced by certain microalgae species belonging to the genus Pseudo‐nitzschia. During the biosensor deployment, concentrations of Pseudo‐nitzschia cells were very low over the study area and measured DA concentrations were below detection. However, the in situ operational detection limit of the system was established using calibrated seawater solutions spiked with DA. The system could detect the toxin at concentrations as low as 0.1 ng mL−1 and presented a linear dynamic range from 0.1 ng mL−1 to 2.0 ng mL−1. This sensor showed promise for in situ detection of DA.
- 16 February 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (7) , 073103
Surface enhanced infrared absorption by nanoantenna on chalcogenide glass substrates
In recent years, nanowires have been proven efficient to enhanced IR absorption of molecules and opened prospects of new ultrasensitive IR sensors. The development of integrated components requires the use of special IR glasses such as chalcogenide or silver halide glasses. In this study, we report the fabrication of a surface enhanced IR absorption substrate composed of nanowires deposited onto a chalcogenide glass slide. It enabled us to detect 4-nitrophenol at the femtomolar level and enhancement factor close to 106 was calculated.
- 16 February 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (7) , 073103
Surface enhanced infrared absorption by nanoantenna on chalcogenide glass substrates
In recent years, nanowires have been proven efficient to enhanced IR absorption of molecules and opened prospects of new ultrasensitive IR sensors. The development of integrated components requires the use of special IR glasses such as chalcogenide or silver halide glasses. In this study, we report the fabrication of a surface enhanced IR absorption substrate composed of nanowires deposited onto a chalcogenide glass slide. It enabled us to detect 4-nitrophenol at the femtomolar level and enhancement factor close to 106 was calculated.
- 1 September 2014
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 104, 49-54
Direct and fast detection of Alexandrium minutum algae by using high frequency microbalance
- 1 September 2014
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 104, 49-54
Direct and fast detection of Alexandrium minutum algae by using high frequency microbalance
- Open Access
- 19 August 2014
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 77, 00015
The effect of the salinity level on conductivity sensor calibration
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 19 August 2014
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 77, 00015
Open AccessThe effect of the salinity level on conductivity sensor calibration
EPJ Web of Conferences, open-access proceedings in physics and related sciences