Unyime Ituk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Unyime Ituk has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Ashraf Samir Habib
Department of Anesthesiology, Duke University School of Medicine, Durham, North Carolina
8 shared publications - Franklin Dexter
Department of Anesthesia, University of Iowa, Iowa City, Iowa
3 shared publications - Kokila N. Thenuwara
Department of Anesthesia, University of Iowa Health Care, Iowa City, IA, United States of America
3 shared publications - Sapna Ravindranath
Department of Anesthesia, Indiana University School of Medicine, Indianapolis, IN 46202, USA
3 shared publications Terrence K. Allen
Duke University Medical Center
3 shared publicationsT.K. Allen
Department of Anesthesiology, Duke University Medical Center, Durham, NC
2 shared publications
Latest Publications
- Open Access
- 26 April 2026
- Published by Wiley in Transfusion Medicine
- Vol. 36 (5) , 475-483
Timing of intrapartum transfusion among obstetric patients, stratified by admission and discharge haemoglobin, relative to anaesthesia care: A retrospective cohort study
Background: We previously validated and implemented criteria for auditing anaesthesiologists with intraoperative transfusion based on low median blood loss of the surgical procedure or absence of anaemia before transfusion. However, obstetrical cases were excluded during implementation, as the peripartum blood management protocol does not include haemoglobin determinations, matching American College of Obstetricians and Gynaecologists recommendations. For non‐obstetrical surgery, intraoperative transfusion is associated with an increased probability of postpartum transfusion. Because of the obstetrical transfusion approach, we hypothesized the opposite relationship between intrapartum and postpartum transfusion. Methods: The retrospective cohort study included all 30 160 patients who delivered at the University of Iowa January 2013 through March 2025. Results: Any RBC administration during anaesthesia care reduced the odds of later transfusion (odds ratio 0.14, 99% confidence interval (CI) 0.11%–0.18%). Single‐unit RBC administration during anaesthesia reduced such odds (0.09, 99% CI 0.06%–0.11%), as did multiple‐unit transfusion (0.18, 99% CI 0.13%–0.24%). McNemar tests had Bonferroni‐adjusted p ‐values p < 0.0001. Many (59%, 99% CI 50%–69%) RBC units started during anaesthesia care were administered to patients who were not anaemic (haemoglobin ≥11 g/dL) at admission. Most patients with single‐unit RBC transfusion and blood loss <2500 mL had stable haemodynamics. Conclusions: Unlike several categories of non‐obstetrical procedures, RBC transfusion during anaesthesia care for delivery was associated with a reduced probability of postpartum RBC transfusion. A reasonable approach for blood bank auditing of anaesthesiologists' obstetric RBC transfusion decision‐making would be to review cases when RBC were administered, there was blood loss <2500 mL, no subsequent transfusion, and discharge haemoglobin ≥9 g/dL.
- 26 April 2026
- Published by Wiley in Transfusion Medicine
- Vol. 36 (5) , 475-483
Open AccessTiming of intrapartum transfusion among obstetric patients, stratified by admission and discharge haemoglobin, relative to anaesthesia care: A retrospective cohort study
Background: We previously validated and implemented criteria for auditing anaesthesiologists with intraoperative transfusion based on low median blood loss of the surgical procedure or absence of anaemia before transfusion. However, obstetrical cases were excluded during implementation, as the peripartum blood management protocol does not include haemoglobin determinations, matching American College of Obstetricians and Gynaecologists recommendations. For non‐obstetrical surgery, intraoperative transfusion is associated with an increased probability of postpartum transfusion. Because of the obstetrical transfusion approach, we hypothesized the opposite relationship between intrapartum and postpartum transfusion. Methods: The retrospective cohort study included all 30 160 patients who delivered at the University of Iowa January 2013 through March 2025. Results: Any RBC administration during anaesthesia care reduced the odds of later transfusion (odds ratio 0.14, 99% confidence interval (CI) 0.11%–0.18%). Single‐unit RBC administration during anaesthesia reduced such odds (0.09, 99% CI 0.06%–0.11%), as did multiple‐unit transfusion (0.18, 99% CI 0.13%–0.24%). McNemar tests had Bonferroni‐adjusted p ‐values p < 0.0001. Many (59%, 99% CI 50%–69%) RBC units started during anaesthesia care were administered to patients who were not anaemic (haemoglobin ≥11 g/dL) at admission. Most patients with single‐unit RBC transfusion and blood loss <2500 mL had stable haemodynamics. Conclusions: Unlike several categories of non‐obstetrical procedures, RBC transfusion during anaesthesia care for delivery was associated with a reduced probability of postpartum RBC transfusion. A reasonable approach for blood bank auditing of anaesthesiologists' obstetric RBC transfusion decision‐making would be to review cases when RBC were administered, there was blood loss <2500 mL, no subsequent transfusion, and discharge haemoglobin ≥9 g/dL.
- Open Access
- 7 April 2026
- Published by Springer Nature in Anesthesiology and Perioperative Science
- Vol. 4 (1)
Relationships in anesthesia work areas between contamination measured as colony-forming units, Staphylococcus aureus detection, and S. aureus transmission
Purpose: Earlier, patients developed surgical site infection for 2.0% of cases without Staphylococcus aureus transmission through anesthesia work areas, 11% with S. aureus transmitted susceptible to prophylactic antibiotic, and 18% with transmission of antibiotic-resistant isolates. A randomized trial and an effectiveness study both found that anesthesiologists who used basic preventive measures (e.g., alcohol releasing intravenous caps) and received feedback on colony-forming units per surface area sampled (CFU) had reduced S. aureus transmission and postoperative healthcare-associated infections. We used prospectively collected data to evaluate whether CFU would be a reliable criterion for hospitals to assess anesthesiologists’ contributions to postoperative infections. Methods: During the summer of 2025, reservoirs (e.g., anesthetist’s hands at case start/end) were sampled during 81 cesarean delivery cases performed in the same operating room. There were ≤ 15 reservoirs sampled per case. Results: 52/1016 reservoir samples had S. aureus detected, more often with greater CFU ( P = 0.0063). The 159/1016 samples with < 100 CFU had no S. aureus . Total CFU of all reservoirs for each case to total S. aureus isolates was 2.50 × 10 9 per S. aureus (standard error 0.53 × 10 9 , N = 81 cases). CFU and S. aureus transmission were uncorrelated (all 15 reservoirs’ unadjusted P ≥ 0.12, Holm-Bonferroni P > 0.99). Conclusions: With substantive contamination (≥ 100 CFU), so few isolates are S. aureus that surrogate measures of insufficient disinfection (e.g., ATP bioluminescence) are inaccurate markers both of S. aureus isolation and transmission. The lack of association between contamination and transmission shows that feedback on CFU provides information on the effectiveness of disinfection, not on S. aureus transmission.
- 7 April 2026
- Published by Springer Nature in Anesthesiology and Perioperative Science
- Vol. 4 (1)
Open AccessRelationships in anesthesia work areas between contamination measured as colony-forming units, Staphylococcus aureus detection, and S. aureus transmission
Purpose: Earlier, patients developed surgical site infection for 2.0% of cases without Staphylococcus aureus transmission through anesthesia work areas, 11% with S. aureus transmitted susceptible to prophylactic antibiotic, and 18% with transmission of antibiotic-resistant isolates. A randomized trial and an effectiveness study both found that anesthesiologists who used basic preventive measures (e.g., alcohol releasing intravenous caps) and received feedback on colony-forming units per surface area sampled (CFU) had reduced S. aureus transmission and postoperative healthcare-associated infections. We used prospectively collected data to evaluate whether CFU would be a reliable criterion for hospitals to assess anesthesiologists’ contributions to postoperative infections. Methods: During the summer of 2025, reservoirs (e.g., anesthetist’s hands at case start/end) were sampled during 81 cesarean delivery cases performed in the same operating room. There were ≤ 15 reservoirs sampled per case. Results: 52/1016 reservoir samples had S. aureus detected, more often with greater CFU ( P = 0.0063). The 159/1016 samples with < 100 CFU had no S. aureus . Total CFU of all reservoirs for each case to total S. aureus isolates was 2.50 × 10 9 per S. aureus (standard error 0.53 × 10 9 , N = 81 cases). CFU and S. aureus transmission were uncorrelated (all 15 reservoirs’ unadjusted P ≥ 0.12, Holm-Bonferroni P > 0.99). Conclusions: With substantive contamination (≥ 100 CFU), so few isolates are S. aureus that surrogate measures of insufficient disinfection (e.g., ATP bioluminescence) are inaccurate markers both of S. aureus isolation and transmission. The lack of association between contamination and transmission shows that feedback on CFU provides information on the effectiveness of disinfection, not on S. aureus transmission.
- Open Access
- 23 January 2026
- Published by Wiley
The Effect of Left Uterine Displacement During Caesarean Delivery on Maternal and Neonatal Outcomes: A Systematic Review & Meta-analysis
Background: Left uterine displacement (LUD) during caesarean delivery (CD) is widely recommended to prevent aortocaval compression and improve maternal haemodynamic and neonatal outcomes. However, prior Cochrane review conducted a decade ago found limited evidence supporting LUD’s efficacy. Objective: To evaluate the impact of LUD on maternal haemodynamic state, vasopressor requirements, and neonatal outcomes during CD Search Strategy: MEDLINE, EMBASE, CINAHL, and Cochrane Central Register of Controlled trials (CENTRAL) from January 1966 to August 2025. Selection Criteria: Randomized controlled trials comparing LUD + supine versus supine position during CD. No language restrictions. Data Collection and Analysis: Using PRISMA guidelines two reviewers independently screened studies, extracted data and assessed risk of bias. A random effects model was used for meta-analysis to estimate pooled odds ratios with 95 % confidence intervals. The protocol was registered on the International Prospective Register of Systematic Reviews (PROSPERO: CRD42023408564). Main Results: Seven studies (666 patients) met inclusion criteria. Pooled data showed no significant differences between LUD + supine versus supine groups for the primary outcome of the incidence of hypotension (OR 0.51, 95% CI: 0.24 to 1.06) or umbilical artery pH (MD (95%CI): 0.01 (-0.01 to 0.02). Maternal systolic or mean blood pressure, incidence of nausea/vomiting or vasopressor requirements did not show significant differences nor did any other neonatal outcomes, including APGAR scores. Conclusion: Left uterine displacement does not significantly impact maternal haemodynamic state, vasopressor use, or neonatal outcomes in the current obstetric anaesthesia practice. Routine LUD application during CD should be reconsidered.
- 23 January 2026
- Published by Wiley
Open AccessThe Effect of Left Uterine Displacement During Caesarean Delivery on Maternal and Neonatal Outcomes: A Systematic Review & Meta-analysis
Background: Left uterine displacement (LUD) during caesarean delivery (CD) is widely recommended to prevent aortocaval compression and improve maternal haemodynamic and neonatal outcomes. However, prior Cochrane review conducted a decade ago found limited evidence supporting LUD’s efficacy. Objective: To evaluate the impact of LUD on maternal haemodynamic state, vasopressor requirements, and neonatal outcomes during CD Search Strategy: MEDLINE, EMBASE, CINAHL, and Cochrane Central Register of Controlled trials (CENTRAL) from January 1966 to August 2025. Selection Criteria: Randomized controlled trials comparing LUD + supine versus supine position during CD. No language restrictions. Data Collection and Analysis: Using PRISMA guidelines two reviewers independently screened studies, extracted data and assessed risk of bias. A random effects model was used for meta-analysis to estimate pooled odds ratios with 95 % confidence intervals. The protocol was registered on the International Prospective Register of Systematic Reviews (PROSPERO: CRD42023408564). Main Results: Seven studies (666 patients) met inclusion criteria. Pooled data showed no significant differences between LUD + supine versus supine groups for the primary outcome of the incidence of hypotension (OR 0.51, 95% CI: 0.24 to 1.06) or umbilical artery pH (MD (95%CI): 0.01 (-0.01 to 0.02). Maternal systolic or mean blood pressure, incidence of nausea/vomiting or vasopressor requirements did not show significant differences nor did any other neonatal outcomes, including APGAR scores. Conclusion: Left uterine displacement does not significantly impact maternal haemodynamic state, vasopressor use, or neonatal outcomes in the current obstetric anaesthesia practice. Routine LUD application during CD should be reconsidered.
- Open Access
- 1 January 2025
- Published by Wiley in Pain Research and Management
- Vol. 2025 (1) , 6903333
Predicting Postcesarean Pain: A Prospective Cohort Study Using a 3‐Question Questionnaire, Local Anesthesia Infiltration, and Observer Rating
Purpose: Acute postoperative pain is a typical complaint following cesarean delivery (CD). The current standard for postcesarean pain management is the use of a multimodal analgesia regimen which is beneficial for many but may be inadequate for some patients. This study aimed to determine if combining patients’ response to a pain rating questionnaire, their pain score during local anesthetic infiltration (LAI) preceding spinal anesthesia for CD, and an anesthesiologist’s prediction of postcesarean pain severity can predict the intensity of postcesarean pain. Methods: This was a prospective study of ninety women undergoing scheduled CD under spinal anesthesia. Patients completed a pain rating questionnaire preoperatively and rated pain on LAI before spinal injection, and an anesthesiologist predicted the severity of postcesarean pain. Postoperative pain scores were assessed at rest and with movement at 6, 24, and 48 h after surgery. Results: The patient’s expected postoperative pain ( β = 0.39, p = 0.0011), perceived analgesic requirements ( β = 0.34, p = 0.0002), pain on LAI ( β = 0.22, p = 0.004), and anesthesiologist’s predicted postoperative pain severity ( β = 0.22, p = 0.01) were associated with mean postoperative pain after CD. The multivariate model analysis found that the pain rating questionnaire and the an anesthesiologist’s prediction of postcesarean pain severity contributed to postoperative pain modeling ( R 2 = 0.27). Conclusion: Combining a preoperative pain rating questionnaire with an anesthesiologist’s prediction of postcesarean pain severity accounted for 27% of the variance in mean postoperative pain with movement and may be a useful tool in predicting postcesarean pain. Implications: This study highlights the potential of a combined preoperative pain rating questionnaire and anesthesiologist’s predictions to improve postcesarean pain management. By accounting for 27% of the variance in mean postcesarean pain with movement, this approach could enhance pain management outcomes for CD patients.
- 1 January 2025
- Published by Wiley in Pain Research and Management
- Vol. 2025 (1) , 6903333
Open AccessPredicting Postcesarean Pain: A Prospective Cohort Study Using a 3‐Question Questionnaire, Local Anesthesia Infiltration, and Observer Rating
Purpose: Acute postoperative pain is a typical complaint following cesarean delivery (CD). The current standard for postcesarean pain management is the use of a multimodal analgesia regimen which is beneficial for many but may be inadequate for some patients. This study aimed to determine if combining patients’ response to a pain rating questionnaire, their pain score during local anesthetic infiltration (LAI) preceding spinal anesthesia for CD, and an anesthesiologist’s prediction of postcesarean pain severity can predict the intensity of postcesarean pain. Methods: This was a prospective study of ninety women undergoing scheduled CD under spinal anesthesia. Patients completed a pain rating questionnaire preoperatively and rated pain on LAI before spinal injection, and an anesthesiologist predicted the severity of postcesarean pain. Postoperative pain scores were assessed at rest and with movement at 6, 24, and 48 h after surgery. Results: The patient’s expected postoperative pain ( β = 0.39, p = 0.0011), perceived analgesic requirements ( β = 0.34, p = 0.0002), pain on LAI ( β = 0.22, p = 0.004), and anesthesiologist’s predicted postoperative pain severity ( β = 0.22, p = 0.01) were associated with mean postoperative pain after CD. The multivariate model analysis found that the pain rating questionnaire and the an anesthesiologist’s prediction of postcesarean pain severity contributed to postoperative pain modeling ( R 2 = 0.27). Conclusion: Combining a preoperative pain rating questionnaire with an anesthesiologist’s prediction of postcesarean pain severity accounted for 27% of the variance in mean postoperative pain with movement and may be a useful tool in predicting postcesarean pain. Implications: This study highlights the potential of a combined preoperative pain rating questionnaire and anesthesiologist’s predictions to improve postcesarean pain management. By accounting for 27% of the variance in mean postcesarean pain with movement, this approach could enhance pain management outcomes for CD patients.
- Open Access
- 1 January 2025
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2025 (1) , 5707084
Noise Perception, Sensitivity, and Patient Outcomes During Cesarean Delivery
Introduction: Noise in the operating room (OR) is a recognized hazard, known to impair communication among staff and increase stress levels. While its effects on healthcare personnel have been studied, little is known about patient perception of noise, particularly during cesarean delivery (CD) under neuraxial anesthesia, where patients are fully conscious. This study aimed to investigate if patients undergoing CD perceive OR noise as stressful and to examine the correlation between actual noise levels and patient‐reported stress. Methods: This prospective observational study was conducted on women undergoing CD at the University of Iowa Hospitals and Clinics. Eligible participants had sound levels recorded in the two ORs and completed three questionnaires 24 h postsurgery: the Weinstein Noise Sensitivity Questionnaire Short Form (WNSSF), a noise perception questionnaire, and a noise‐related stress questionnaire. Noise levels were measured using a Spartan model 730 noise dosimeter, and the study analyzed the correlation between noise sensitivity, perception, and stress, as well as the effect of surgery urgency on noise levels. Results: Out of 70 participants, 67 were included in the final analysis. The ambient noise levels in the ORs were 53.4 and 58.5 dB, respectively. The mean noise sensitivity score was 17.6 (±3.9). Noise was perceived as very soft or soft by 23% of patients, comfortable by 67.8%, and loud or unpleasant by 9.2%. A significant association was found between noise sensitivity and stress (OR 1.15 [95 CI 1.03–1.31], p = 0.038). Conclusions: The study found that a subset of patients experienced noise‐related stress during CD, particularly those with higher noise sensitivity. These findings suggest the need for interventions to reduce OR noise or manage patient perceptions of noise.
- 1 January 2025
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2025 (1) , 5707084
Open AccessNoise Perception, Sensitivity, and Patient Outcomes During Cesarean Delivery
Introduction: Noise in the operating room (OR) is a recognized hazard, known to impair communication among staff and increase stress levels. While its effects on healthcare personnel have been studied, little is known about patient perception of noise, particularly during cesarean delivery (CD) under neuraxial anesthesia, where patients are fully conscious. This study aimed to investigate if patients undergoing CD perceive OR noise as stressful and to examine the correlation between actual noise levels and patient‐reported stress. Methods: This prospective observational study was conducted on women undergoing CD at the University of Iowa Hospitals and Clinics. Eligible participants had sound levels recorded in the two ORs and completed three questionnaires 24 h postsurgery: the Weinstein Noise Sensitivity Questionnaire Short Form (WNSSF), a noise perception questionnaire, and a noise‐related stress questionnaire. Noise levels were measured using a Spartan model 730 noise dosimeter, and the study analyzed the correlation between noise sensitivity, perception, and stress, as well as the effect of surgery urgency on noise levels. Results: Out of 70 participants, 67 were included in the final analysis. The ambient noise levels in the ORs were 53.4 and 58.5 dB, respectively. The mean noise sensitivity score was 17.6 (±3.9). Noise was perceived as very soft or soft by 23% of patients, comfortable by 67.8%, and loud or unpleasant by 9.2%. A significant association was found between noise sensitivity and stress (OR 1.15 [95 CI 1.03–1.31], p = 0.038). Conclusions: The study found that a subset of patients experienced noise‐related stress during CD, particularly those with higher noise sensitivity. These findings suggest the need for interventions to reduce OR noise or manage patient perceptions of noise.
- Open Access
- 20 December 2023
- Published by BMJ in BMJ Open Quality
- Vol. 12 (4) , e002389
Implementation and evaluation of an event reporting system in an academic anaesthesia department
Background Reporting adverse clinical events is essential to a culture of safety in healthcare. However, self-reporting such events is generally not widely prevalent in a typical academic anaesthesia department. Methods We set out to create a self-reporting tool to securely accept data from multiple anaesthesia service locations, including data linked to our electronic anaesthesia record, and combine them into an accessible database. We created a web-based database module for incident reporting integrated into the department’s intranet. The system was also designed to actively prompt anaesthesia providers for reports following each day of clinical work. Results 478 events were recorded in the database in the first year of implementation. There were 33 347 anaesthesia encounters in that period, translating to a reporting rate of 1.43% (95% CI 1.31% to 1.57%). In the second year, which coincided with the second phase of implementation, 608 events were reported out of 45 985 anaesthesia encounters, for a reporting rate of 1.32% (95% CI 1.22% to 1.43%). Approximately 40% of events entered into the database occurred in a non-operating room location. The annual reporting rates for 2014, 2015, 2016, 2017, 2018 and 2019 were 1.26% (95% CI 1.16% to 1.37%), 1.15% (95% CI 1.05% to 1.25%), 1% (95% CI 0.9% to 1.1%), 0.6% (95% CI 0.53% to 0.68%), 0.5% (95% CI 0.44% to 0.57%), 0.4% (95% CI 0.3% to 0.5%), respectively. Conclusions Our incident reporting system facilitated reporting of events within and outside the operating room. The system captured event data valid for quality improvement within the anaesthesia department.
- 20 December 2023
- Published by BMJ in BMJ Open Quality
- Vol. 12 (4) , e002389
Open AccessImplementation and evaluation of an event reporting system in an academic anaesthesia department
Background Reporting adverse clinical events is essential to a culture of safety in healthcare. However, self-reporting such events is generally not widely prevalent in a typical academic anaesthesia department. Methods We set out to create a self-reporting tool to securely accept data from multiple anaesthesia service locations, including data linked to our electronic anaesthesia record, and combine them into an accessible database. We created a web-based database module for incident reporting integrated into the department’s intranet. The system was also designed to actively prompt anaesthesia providers for reports following each day of clinical work. Results 478 events were recorded in the database in the first year of implementation. There were 33 347 anaesthesia encounters in that period, translating to a reporting rate of 1.43% (95% CI 1.31% to 1.57%). In the second year, which coincided with the second phase of implementation, 608 events were reported out of 45 985 anaesthesia encounters, for a reporting rate of 1.32% (95% CI 1.22% to 1.43%). Approximately 40% of events entered into the database occurred in a non-operating room location. The annual reporting rates for 2014, 2015, 2016, 2017, 2018 and 2019 were 1.26% (95% CI 1.16% to 1.37%), 1.15% (95% CI 1.05% to 1.25%), 1% (95% CI 0.9% to 1.1%), 0.6% (95% CI 0.53% to 0.68%), 0.5% (95% CI 0.44% to 0.57%), 0.4% (95% CI 0.3% to 0.5%), respectively. Conclusions Our incident reporting system facilitated reporting of events within and outside the operating room. The system captured event data valid for quality improvement within the anaesthesia department.
- Open Access
- 8 March 2023
- Published by Springer Nature in Cureus
- Vol. 15 (3)
The Association of Anesthesia Type and Neonatal Outcomes Following Category-1 Cesarean Delivery: A Retrospective Cohort Study
Objectives Neuraxial anesthesia is the preferred anesthesia technique for cesarean delivery due to a decreased risk of adverse events. However, general anesthesia is often employed during emergent cesarean deliveries to achieve a shorter decision-to-delivery interval. The objective of this study was to determine if the conversion of epidural labor analgesia to surgical anesthesia for a category-1 cesarean delivery is associated with significant neonatal morbidity. Study design This was a retrospective cohort study of all intrapartum category-1 cesarean deliveries performed at an academic tertiary care institution between August 2016 and July 2021. The primary outcome was neonatal morbidity, defined as a composite of neonatal umbilical artery pH < 7.10 and/or 5‐min Apgar score < 7, and/or neonatal intensive care unit admission. A multivariate regression analysis was performed to control for the presence of covariates and examine the degree to which they influenced the outcome. Results A total of 185 mother-neonate pairs qualified for inclusion, of which 23 had cesarean delivery under general anesthesia and 162 under epidural anesthesia. There was no significant difference in adverse neonatal outcomes between category-1 cesarean deliveries done under general anesthesia compared to epidural anesthesia (47% vs 35%, p = 0.3). The incidence of umbilical arterial pH < 7.10 was higher in the general anesthesia group compared to the epidural anesthesia group (35% vs 12%, p = 0.018). The multivariate regression model showed that gestational age (OR = 0.63; 95% CI = 0.51-0.75, p = <0.001) and non-reassuring fetal heart trace (OR = 0.18; 95% CI = 0.05-0.58, p = 0.005) were significant predictors of adverse neonatal outcome. Conclusion Our results suggest that the conversion of epidural analgesia to surgical anesthesia for category-1 cesarean delivery in women with a functional labor epidural catheter is not associated with poorer neonatal outcomes.
- 8 March 2023
- Published by Springer Nature in Cureus
- Vol. 15 (3)
Open AccessThe Association of Anesthesia Type and Neonatal Outcomes Following Category-1 Cesarean Delivery: A Retrospective Cohort Study
Objectives Neuraxial anesthesia is the preferred anesthesia technique for cesarean delivery due to a decreased risk of adverse events. However, general anesthesia is often employed during emergent cesarean deliveries to achieve a shorter decision-to-delivery interval. The objective of this study was to determine if the conversion of epidural labor analgesia to surgical anesthesia for a category-1 cesarean delivery is associated with significant neonatal morbidity. Study design This was a retrospective cohort study of all intrapartum category-1 cesarean deliveries performed at an academic tertiary care institution between August 2016 and July 2021. The primary outcome was neonatal morbidity, defined as a composite of neonatal umbilical artery pH < 7.10 and/or 5‐min Apgar score < 7, and/or neonatal intensive care unit admission. A multivariate regression analysis was performed to control for the presence of covariates and examine the degree to which they influenced the outcome. Results A total of 185 mother-neonate pairs qualified for inclusion, of which 23 had cesarean delivery under general anesthesia and 162 under epidural anesthesia. There was no significant difference in adverse neonatal outcomes between category-1 cesarean deliveries done under general anesthesia compared to epidural anesthesia (47% vs 35%, p = 0.3). The incidence of umbilical arterial pH < 7.10 was higher in the general anesthesia group compared to the epidural anesthesia group (35% vs 12%, p = 0.018). The multivariate regression model showed that gestational age (OR = 0.63; 95% CI = 0.51-0.75, p = <0.001) and non-reassuring fetal heart trace (OR = 0.18; 95% CI = 0.05-0.58, p = 0.005) were significant predictors of adverse neonatal outcome. Conclusion Our results suggest that the conversion of epidural analgesia to surgical anesthesia for category-1 cesarean delivery in women with a functional labor epidural catheter is not associated with poorer neonatal outcomes.
- Open Access
- 23 December 2022
- Published by Qeios Ltd
Review of: "Delayed vs Early Umbilical Cord Clamping in 100 Preterm Infants: an RCT from Bhavnagar, Gujarat"
This study is aims to determine the hematological effects of delayed cord clamping compared to early cord clamping in preterm neonates. The effects of delayed cord clamping has been widely studied and there is a significant amount of literature on th...
- 23 December 2022
- Published by Qeios Ltd
Open AccessReview of: "Delayed vs Early Umbilical Cord Clamping in 100 Preterm Infants: an RCT from Bhavnagar, Gujarat"
This study is aims to determine the hematological effects of delayed cord clamping compared to early cord clamping in preterm neonates. The effects of delayed cord clamping has been widely studied and there is a significant amount of literature on th...