Ahmad Shabir Ahmadyar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ahmad Shabir Ahmadyar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Gregor Verbic
The University of Sydney, Camperdown, NSW, Australia
6 shared publications - Archie C. Chapman
The University of Queensland Brisbane Australia
2 shared publications - David John Hill
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
2 shared publications - Hesamoddin Marzooghi
School of Engineering and Technology Central Queensland University (CQ University) Brisbane QLD 4000 Australia
2 shared publications - Jin Ma
School of Electrical and Computer Engineering, The University of Sydney, Sydney, NSW, Australia
2 shared publications - Mohammad Seydali Seyf Abad
Electrical and Information Engineering, The University of Sydney, Sydney, New South Wales Australia 2006
2 shared publications
Latest Publications
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modelling of Grid-forming Inverters for Power System Applications in DIgSILENT PowerFactory
Grid-forming inverters are becoming an important technology to address the stability issues resulting from the retirement of conventional synchronous generation. Unlike traditional grid-following converters, predominantly used today to connect wind and solar farms, grid-forming converters behave much like synchronous machines by providing both inertia and system strength. Against this backdrop, this paper provides a detailed modelling process in DIgSILENT PowerFactory and compares different control strategies for grid-tied converters using a simple yet realistic four-bus test system. The results demonstrate that compared with grid-following control, grid-forming control can markedly improve both power systems frequency performance and system strength.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Modelling of Grid-forming Inverters for Power System Applications in DIgSILENT PowerFactory
Grid-forming inverters are becoming an important technology to address the stability issues resulting from the retirement of conventional synchronous generation. Unlike traditional grid-following converters, predominantly used today to connect wind and solar farms, grid-forming converters behave much like synchronous machines by providing both inertia and system strength. Against this backdrop, this paper provides a detailed modelling process in DIgSILENT PowerFactory and compares different control strategies for grid-tied converters using a simple yet realistic four-bus test system. The results demonstrate that compared with grid-following control, grid-forming control can markedly improve both power systems frequency performance and system strength.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3238-3248
Scenario and Sensitivity Based Stability Analysis of the High Renewable Future Grid
It can be expected that the power systems of the future will be significantly different from today’s, especially due to increasing renewable energy sources (RESs), storage systems, and price-responsive users leading to large uncertainty and complexity. The operation of these future grids (FGs) at levels of renewable energy approaching 100% will require all the usual stability analysis along with new issues in a much more complex situation than has been encountered in the past. In fact, how close we can get to this desired level will likely be dependent on the assessed stability limits. Therefore, in this study, we use a novel scenario-sensitivity-contingency based framework to evaluate the system stability along possible evolution pathways towards high renewable FGs. As a case study, we carry out our studies based on proposed future scenarios and sensitivities for the Australian FG. Using a simulation platform that encompasses market simulation, load flow calculation and stability assessment altogether, the impact of grid strength, level of prosumers, and utility storage on the stability of the FG is studied and quantified indices for long term stability have been devised. The results of this study enable us to address the underlying stability issues of the FGs.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 3238-3248
Scenario and Sensitivity Based Stability Analysis of the High Renewable Future Grid
It can be expected that the power systems of the future will be significantly different from today’s, especially due to increasing renewable energy sources (RESs), storage systems, and price-responsive users leading to large uncertainty and complexity. The operation of these future grids (FGs) at levels of renewable energy approaching 100% will require all the usual stability analysis along with new issues in a much more complex situation than has been encountered in the past. In fact, how close we can get to this desired level will likely be dependent on the assessed stability limits. Therefore, in this study, we use a novel scenario-sensitivity-contingency based framework to evaluate the system stability along possible evolution pathways towards high renewable FGs. As a case study, we carry out our studies based on proposed future scenarios and sensitivities for the Australian FG. Using a simulation platform that encompasses market simulation, load flow calculation and stability assessment altogether, the impact of grid strength, level of prosumers, and utility storage on the stability of the FG is studied and quantified indices for long term stability have been devised. The results of this study enable us to address the underlying stability issues of the FGs.
- Open Access
Distributionally Robust Distributed Generation Hosting Capacity Assessment in Distribution Systems
Uncertainties associated with the loads and the output power of distributed generations create challenges in quantifying the integration limits of distributed generations in distribution networks, i.e., hosting capacity. To address this, we propose a distributionally robust optimization-based method to determine the hosting capacity considering the voltage rise, thermal capacity of the feeders and short circuit level constraints. In the proposed method, the uncertain variables are modeled as stochastic variables following ambiguous distributions defined based on the historical data. The distributionally robust optimization model guarantees that the probability of the constraint violation does not exceed a given risk level, which can control robustness of the solution. To solve the distributionally robust optimization model of the hosting capacity, we reformulated it as a joint chance constrained problem, which is solved using the sample average approximation technique. To demonstrate the efficacy of the proposed method, a modified IEEE 33-bus distribution system is used as the test-bed. Simulation results demonstrate how the sample size of historical data affects the hosting capacity. Furthermore, using the proposed method, the impact of electric vehicles aggregated demand and charging stations are investigated on the hosting capacity of different distributed generation technologies.
Open AccessDistributionally Robust Distributed Generation Hosting Capacity Assessment in Distribution Systems
Uncertainties associated with the loads and the output power of distributed generations create challenges in quantifying the integration limits of distributed generations in distribution networks, i.e., hosting capacity. To address this, we propose a distributionally robust optimization-based method to determine the hosting capacity considering the voltage rise, thermal capacity of the feeders and short circuit level constraints. In the proposed method, the uncertain variables are modeled as stochastic variables following ambiguous distributions defined based on the historical data. The distributionally robust optimization model guarantees that the probability of the constraint violation does not exceed a given risk level, which can control robustness of the solution. To solve the distributionally robust optimization model of the hosting capacity, we reformulated it as a joint chance constrained problem, which is solved using the sample average approximation technique. To demonstrate the efficacy of the proposed method, a modified IEEE 33-bus distribution system is used as the test-bed. Simulation results demonstrate how the sample size of historical data affects the hosting capacity. Furthermore, using the proposed method, the impact of electric vehicles aggregated demand and charging stations are investigated on the hosting capacity of different distributed generation technologies.
- 26 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 9 (4) , 1935-1947
Probabilistic Assessment of Hosting Capacity in Radial Distribution Systems
High penetration of distributed generation (DG) is mainly constrained by voltage related issues. Due to the uncertainties associated with type, size and location of DGs, it is difficult to quantify their integration limits in distribution networks, i.e., hosting capacity (HC). To address this issue, this paper proposes a probabilistic based framework to determine the maximum integration limits of DGs considering the voltage rise and voltage deviation constraints. Such framework requires use of the HC model, which can be formulated as a nonlinear optimization problem. Adding the voltage deviation constraint in the HC problem makes the model unsolvable. We address this issue by proposing a two-step algorithm to linearize the HC model. Then, using the linearized model, a probabilistic framework is proposed for considering the load variability and DGs uncertainties. To validate the efficacy and accuracy of the proposed framework, we identify the HC of a balanced and an unbalanced distribution networks and compare our results with those obtained from comprehensive power flow method and the traditional conservative planning. Finally, using the proposed framework, the impact of voltage deviation constraint, load growth, DG type and network structure on the HC are comprehensively studied using different DG technologies (i.e., Photovoltaics and wind).
- 26 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 9 (4) , 1935-1947
Probabilistic Assessment of Hosting Capacity in Radial Distribution Systems
High penetration of distributed generation (DG) is mainly constrained by voltage related issues. Due to the uncertainties associated with type, size and location of DGs, it is difficult to quantify their integration limits in distribution networks, i.e., hosting capacity (HC). To address this issue, this paper proposes a probabilistic based framework to determine the maximum integration limits of DGs considering the voltage rise and voltage deviation constraints. Such framework requires use of the HC model, which can be formulated as a nonlinear optimization problem. Adding the voltage deviation constraint in the HC problem makes the model unsolvable. We address this issue by proposing a two-step algorithm to linearize the HC model. Then, using the linearized model, a probabilistic framework is proposed for considering the load variability and DGs uncertainties. To validate the efficacy and accuracy of the proposed framework, we identify the HC of a balanced and an unbalanced distribution networks and compare our results with those obtained from comprehensive power flow method and the traditional conservative planning. Finally, using the proposed framework, the impact of voltage deviation constraint, load growth, DG type and network structure on the HC are comprehensively studied using different DG technologies (i.e., Photovoltaics and wind).
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 4444-4453
A Framework for Assessing Renewable Integration Limits With Respect to Frequency Performance
The increasing penetration of non-synchronous renewable energy sources (NS-RES) and demand side-technologies alter the dynamic characteristics, and particularly, the frequency behavior of a power system. Given this, we propose a framework for assessing renewable integration limits concerning power system frequency performance using a time-series scenario-based approach. By considering a large number of future scenarios and their sensitivities with respect to different parameters, we can identify maximum non-synchronous instantaneous penetration limits for a wide range of possible scenarios. Further, we derive a dynamic inertia constraint and incorporate it into the market dispatch model to reduce the detrimental impacts of high NS-RES penetration on the frequency performance. The results using the Australian future grid as a test case show that such an explicit inertia constraint ensures power system frequency stability for all credible contingencies. To improve the frequency performance, we assess and quantify the contribution of a wide range of technologies, including synchronous condensers, synthetic inertia from wind farms and a governor-like response from de-loaded wind farms. The results show that the last option is the most effective one.
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 4444-4453
A Framework for Assessing Renewable Integration Limits With Respect to Frequency Performance
The increasing penetration of non-synchronous renewable energy sources (NS-RES) and demand side-technologies alter the dynamic characteristics, and particularly, the frequency behavior of a power system. Given this, we propose a framework for assessing renewable integration limits concerning power system frequency performance using a time-series scenario-based approach. By considering a large number of future scenarios and their sensitivities with respect to different parameters, we can identify maximum non-synchronous instantaneous penetration limits for a wide range of possible scenarios. Further, we derive a dynamic inertia constraint and incorporate it into the market dispatch model to reduce the detrimental impacts of high NS-RES penetration on the frequency performance. The results using the Australian future grid as a test case show that such an explicit inertia constraint ensures power system frequency stability for all credible contingencies. To improve the frequency performance, we assess and quantify the contribution of a wide range of technologies, including synchronous condensers, synthetic inertia from wind farms and a governor-like response from de-loaded wind farms. The results show that the last option is the most effective one.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Assessment of minimum inertia requirement for system frequency stability
The reduced amount of rotational kinetic energy in power systems has significant detrimental impacts on system frequency behaviour. To ensure system security, this issue must be addressed in a systematic way. Given this, we consider three different metrics, namely i) minimum power penetration from synchronous generators, ii) minimum rated power of synchronous generators, and iii) minimum synchronous kinetic energy, as frequency control constraints in the market dispatch model, and assess frequency behaviour of the system for these metrics. The results show that each metric has a different impact on market dispatch, and, accordingly, on the system frequency behaviour. It is shown that with high penetration of converter-based generation, we need to consider a minimum kinetic energy requirement as a frequency control security constraint in the market dispatch model to guarantee the frequency stability of power systems.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Assessment of minimum inertia requirement for system frequency stability
The reduced amount of rotational kinetic energy in power systems has significant detrimental impacts on system frequency behaviour. To ensure system security, this issue must be addressed in a systematic way. Given this, we consider three different metrics, namely i) minimum power penetration from synchronous generators, ii) minimum rated power of synchronous generators, and iii) minimum synchronous kinetic energy, as frequency control constraints in the market dispatch model, and assess frequency behaviour of the system for these metrics. The results show that each metric has a different impact on market dispatch, and, accordingly, on the system frequency behaviour. It is shown that with high penetration of converter-based generation, we need to consider a minimum kinetic energy requirement as a frequency control security constraint in the market dispatch model to guarantee the frequency stability of power systems.
- 22 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 8 (1) , 230-238
Coordinated Operation Strategy of Wind Farms for Frequency Control by Exploring Wake Interaction
This paper proposes a coordinated wind farm (WF) operation strategy that exploits the wake interaction within a WF. In contrast to the conventional WF operation strategy where each wind turbine (WT) is optimized individually, three operation strategies are suggested: 1) maximization of the WF's power while maintaining WF's rotational kinetic energy; 2) maximization of the WF's rotational kinetic energy while maintaining WF's output power; and 3) a de-loaded strategy whereby the WF's rotational kinetic energy is maximized for a fixed de-loading margin. The three operation strategies are formulated as nonlinear optimization problems and solved in a central WF controller. The optimal rotor speeds and pitch angles are used as reference values in the individual WTs. The optimization results for the three respective operation strategies show that: 1) up to 3% increase in the WF's output power; 2) up to 23% increase in the WF's rotational kinetic energy; and 3) up to 28% increase in the WF's rotational kinetic energy and 8% reserve power while operating the WF in a 5% de-loaded mode with respect to the conventional operation strategy. Time-domain simulations show that the proposed operation strategy noticeably improves the WF's performance in frequency control.
- 22 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 8 (1) , 230-238
Coordinated Operation Strategy of Wind Farms for Frequency Control by Exploring Wake Interaction
This paper proposes a coordinated wind farm (WF) operation strategy that exploits the wake interaction within a WF. In contrast to the conventional WF operation strategy where each wind turbine (WT) is optimized individually, three operation strategies are suggested: 1) maximization of the WF's power while maintaining WF's rotational kinetic energy; 2) maximization of the WF's rotational kinetic energy while maintaining WF's output power; and 3) a de-loaded strategy whereby the WF's rotational kinetic energy is maximized for a fixed de-loading margin. The three operation strategies are formulated as nonlinear optimization problems and solved in a central WF controller. The optimal rotor speeds and pitch angles are used as reference values in the individual WTs. The optimization results for the three respective operation strategies show that: 1) up to 3% increase in the WF's output power; 2) up to 23% increase in the WF's rotational kinetic energy; and 3) up to 28% increase in the WF's rotational kinetic energy and 8% reserve power while operating the WF in a 5% de-loaded mode with respect to the conventional operation strategy. Time-domain simulations show that the proposed operation strategy noticeably improves the WF's performance in frequency control.
- Open Access
Exploring Wake Interaction for Frequency Control in Wind Farms
The increasing integration of wind generation is accompanied with a growing concern about secure and reliable power system operation. Due to the intermittent nature of wind, the base-load units need to cycle significantly more than they were designed for, resulting in reduced life cycle and increased costs. Therefore, it is becoming necessary for wind turbines to take part in frequency control, and reduce the need for additional ancillary services provided by conventional generators. In this paper, we propose an optimised operation strategy for the wind farms. In this strategy, we maximise the kinetic energy of wind turbines by an optimal combination of the rotor speed and the pitch angle. We exploit the wake interaction in a wind farm, and de-load some of the up-wind turbines. We show that the kinetic energy accumulated in the rotating masses of the WTs can be increased compared to the base case without compromising efficiency of the wind farm. In a specific system, we show that by implementing this strategy, and injecting the stored kinetic energy of the WTs' rotors into the system during a frequency dip, we can delay the system frequency nadir up to 30 s.
Open AccessExploring Wake Interaction for Frequency Control in Wind Farms
The increasing integration of wind generation is accompanied with a growing concern about secure and reliable power system operation. Due to the intermittent nature of wind, the base-load units need to cycle significantly more than they were designed for, resulting in reduced life cycle and increased costs. Therefore, it is becoming necessary for wind turbines to take part in frequency control, and reduce the need for additional ancillary services provided by conventional generators. In this paper, we propose an optimised operation strategy for the wind farms. In this strategy, we maximise the kinetic energy of wind turbines by an optimal combination of the rotor speed and the pitch angle. We exploit the wake interaction in a wind farm, and de-load some of the up-wind turbines. We show that the kinetic energy accumulated in the rotating masses of the WTs can be increased compared to the base case without compromising efficiency of the wind farm. In a specific system, we show that by implementing this strategy, and injecting the stored kinetic energy of the WTs' rotors into the system during a frequency dip, we can delay the system frequency nadir up to 30 s.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control strategy for optimal participation of wind farms in primary frequency control
This paper proposes an optimal control strategy for participation of wind farms (WFs) in primary frequency control. In this strategy, we exploit wake interaction in a WF to maximise the total kinetic energy (KE) of the wind turbines' (WTs') rotating masses in the WF, and optimally deploy this KE after a frequency event to reduce the frequency nadir, by controlling the rate of change of the rotor speed. The amount of the KE injected into the system by the controller is proportional to the rate of change of frequency (RoCoF) and the frequency deviation after the contingency. By implementing this strategy in a test system with high penetration of wind energy, the stored KE of the WTs in the WF is gradually injected into the system during a frequency excursion. The results show that not only the system frequency nadir is reduced, but also the system frequency is kept relatively uniform for up to 50s.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control strategy for optimal participation of wind farms in primary frequency control
This paper proposes an optimal control strategy for participation of wind farms (WFs) in primary frequency control. In this strategy, we exploit wake interaction in a WF to maximise the total kinetic energy (KE) of the wind turbines' (WTs') rotating masses in the WF, and optimally deploy this KE after a frequency event to reduce the frequency nadir, by controlling the rate of change of the rotor speed. The amount of the KE injected into the system by the controller is proportional to the rate of change of frequency (RoCoF) and the frequency deviation after the contingency. By implementing this strategy in a test system with high penetration of wind energy, the stored KE of the WTs in the WF is gradually injected into the system during a frequency excursion. The results show that not only the system frequency nadir is reduced, but also the system frequency is kept relatively uniform for up to 50s.