Xianlin Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xianlin Pan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jiangtao Zhang
National Institute of Metrology, Beijing, China
4 shared publications - Jun Lin
Jilin University
2 shared publications - Qing He
National Institute of Metrology, Beijing 100029, China
2 shared publications Zhaomin Shi
Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130026, Jilin, Peoples R China
2 shared publications- Zhaomin Shi
National Institute of Metrology, Beijing, China
2 shared publications - Ilya F. Budovsky
National Measurement Institute, Lindfield, NSW, Australia
1 shared publication
Latest Publications
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
AC–DC Transfer and Verification of Ultra-Low Frequency Voltage From 0.1 to 10 Hz
A system for ac-dc voltage transfer at ultra-low frequencies is established with dual-heater thermal voltage converter (DHTVC) in this paper. The system is based on the premise that the thermoelectric potential of TVC is square related with the input voltages. The output thermoelectric potential is constant when two orthogonal and equal-amplitude sinusoidal signals are input to the DHTVC. How to evaluate and compensate the key parameters that affect the stability of output thermoelectric potential is discussed in detail. In this paper a verification method is also proposed to prove the accuracy of the ac-dc transfer results at low frequencies based on quantum voltage technology. The high-precision digitizer PXI-5922 is introduced as the transfer standard. The ac-dc difference of sampling error is calibrated using ac-dc voltage transfer with DHTVC as the reference standard at low frequencies down to 0.1 Hz. The dc and ultra-low frequency errors are also calibrated by programmable Josephson voltage standard (PJVS). The uncertainties of calibration results from two different methods are evaluated respectively. The calibration results from ac-dc voltage transfer with DHTVC and PJVS show good agreement and inconsistency is less than 5 μV/V at frequency ranges from 10 Hz down to 0.1 Hz.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
AC–DC Transfer and Verification of Ultra-Low Frequency Voltage From 0.1 to 10 Hz
A system for ac-dc voltage transfer at ultra-low frequencies is established with dual-heater thermal voltage converter (DHTVC) in this paper. The system is based on the premise that the thermoelectric potential of TVC is square related with the input voltages. The output thermoelectric potential is constant when two orthogonal and equal-amplitude sinusoidal signals are input to the DHTVC. How to evaluate and compensate the key parameters that affect the stability of output thermoelectric potential is discussed in detail. In this paper a verification method is also proposed to prove the accuracy of the ac-dc transfer results at low frequencies based on quantum voltage technology. The high-precision digitizer PXI-5922 is introduced as the transfer standard. The ac-dc difference of sampling error is calibrated using ac-dc voltage transfer with DHTVC as the reference standard at low frequencies down to 0.1 Hz. The dc and ultra-low frequency errors are also calibrated by programmable Josephson voltage standard (PJVS). The uncertainties of calibration results from two different methods are evaluated respectively. The calibration results from ac-dc voltage transfer with DHTVC and PJVS show good agreement and inconsistency is less than 5 μV/V at frequency ranges from 10 Hz down to 0.1 Hz.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Comparison of phase angle errors of current shunts between NMIA and NIM
This paper describes a comparison of current shunt phase angle error measurement between NMIA and NIM at frequencies from 1 kHz to 100 kHz. A set of cage design shunts has been developed at NMIA and their phase angle errors determined with Thermal Power Converter (TPC) and step-up method. A set of Inductive Current Dividers (ICDs) with ratio of 2:1, 5:1 and 10:1 have also been developed to measure the phase angle errors of shunts at NIM. Based on two totally different methods, the current shunts at range from 0.5 A to 10 A have been compared at frequencies up to 100 kHz. The phase angle error values measured by two different methods show excellent agreement, within 30 μrad at frequencies up to 100 kHz and currents from 0.5 A to 10 A.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Comparison of phase angle errors of current shunts between NMIA and NIM
This paper describes a comparison of current shunt phase angle error measurement between NMIA and NIM at frequencies from 1 kHz to 100 kHz. A set of cage design shunts has been developed at NMIA and their phase angle errors determined with Thermal Power Converter (TPC) and step-up method. A set of Inductive Current Dividers (ICDs) with ratio of 2:1, 5:1 and 10:1 have also been developed to measure the phase angle errors of shunts at NIM. Based on two totally different methods, the current shunts at range from 0.5 A to 10 A have been compared at frequencies up to 100 kHz. The phase angle error values measured by two different methods show excellent agreement, within 30 μrad at frequencies up to 100 kHz and currents from 0.5 A to 10 A.
- 25 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2053-2059
Self-Calibration and Verification of Phase Angle Errors of Two Voltage Dividers at High Frequencies
- 25 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2053-2059
Self-Calibration and Verification of Phase Angle Errors of Two Voltage Dividers at High Frequencies
- 8 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (3) , 593-599
Self-Calibration of the Phase Angle Errors of RVDs at Frequencies Up to 100 kHz
A set of coaxial resistive voltage dividers (RVDs) with serial-parallel connection has been designed. A new method has also been proposed to calibrate phase angle errors of RVDs at frequencies up to 100 kHz. The method is mainly based on a special proportional relationship with the resistance and capacitance between two RVDs with identical structure, and the assumption is that the stray capacitance distribution is identical for both RVDs. The absolute phase angle error of an RVD can be derived from the phase difference between the two RVDs. The RVD with ratio of 100:1 consisting of 100-Ω resistive elements has been built and self-calibrated. After the self-calibration of phase angle errors of the RVDs, a buffer has been introduced to the output of the RVD to reduce external loading error for the practical application. Finally, the standard uncertainty in phase angle error of the 100:1 RVD with buffer consisting of 100-Ω resistive elements is within 30 μrad at 100 kHz.
- 8 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (3) , 593-599
Self-Calibration of the Phase Angle Errors of RVDs at Frequencies Up to 100 kHz
A set of coaxial resistive voltage dividers (RVDs) with serial-parallel connection has been designed. A new method has also been proposed to calibrate phase angle errors of RVDs at frequencies up to 100 kHz. The method is mainly based on a special proportional relationship with the resistance and capacitance between two RVDs with identical structure, and the assumption is that the stray capacitance distribution is identical for both RVDs. The absolute phase angle error of an RVD can be derived from the phase difference between the two RVDs. The RVD with ratio of 100:1 consisting of 100-Ω resistive elements has been built and self-calibrated. After the self-calibration of phase angle errors of the RVDs, a buffer has been introduced to the output of the RVD to reduce external loading error for the practical application. Finally, the standard uncertainty in phase angle error of the 100:1 RVD with buffer consisting of 100-Ω resistive elements is within 30 μrad at 100 kHz.