Marie-Ève Delage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marie-Ève Delage has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Luc Beaulieu
Physique, génie physique et optique, Universite Laval, 2375 rue de la Terrasse, 1401 18e rue, Quebec, G1J 1Z4, CANADA
4 shared publications Dominic Larivière
Laboratoire de radioécologie, Département de chimie, Université Laval, Québec, CANADA
3 shared publicationsMarie-Ève Lecavalier
Laboratoire de radioécologie, Département de chimie, Université Laval, Québec, CANADA
3 shared publicationsClaudine Nì Allen
2 shared publicationsClaudine Allen
1 shared publication- Claudine Ni. Allen
National Research Council Canada (Canada)
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (15) , 155019
Investigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry
Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distilled water at various concentrations (0.01–1.2 g l −1 ). The solutions were irradiated with photon beams at 6 and 23 MV. The dependence of the light produced as a function of sample concentration was studied using a spectrometer with a fixed integration time. Spectral measurements of the luminescent solution and the blank solution (distilled water only) were taken to deconvolve the Cherenkov and quinine contribution to the overall emission spectrum. Using a CCD camera, intensity profiles were obtained for the blank and the 1.00 g l −1 solutions to compare them with the dose predicted by a treatment planning system. The luminescent intensity of the samples was found to follow a logarithmic trend as a function of the quinine concentration. Based on the spectral deconvolution of the 1.00 g l −1 solution, 52.4% ± 0.7% and 52.7% ± 0.7% of the signal in the visible range results from the quinine emission at 6 and 23 MV, respectively. The remaining fraction of the spectrum is due to the Cherenkov light that has not been converted. The fraction of the Cherenkov emission produced between 250 nm and 380 nm in the water and that was absorbed by the fluorophore reached 24.8% and 9.4% respectively at 6 and 23 MV. X-ray stimulated fluorescence of the quinine was then proven to be the principal cause to the increased total light output compared to the water-only signal. This new information reinforces the direct correlation of the solution intensity to the dose deposition.
- 1 August 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (15) , 155019
Open AccessInvestigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry
Recent studies have proposed that adding quinine to water while performing Cherenkov volumetric dosimetry improves the skewed percent depth dose measurement. The aim of this study was to quantify the ability of quinine to convert directional Cherenkov emission to isotropic fluorescence and evaluate its contribution to the total emitted light. Aqueous solutions of quinine were prepared with distilled water at various concentrations (0.01–1.2 g l −1 ). The solutions were irradiated with photon beams at 6 and 23 MV. The dependence of the light produced as a function of sample concentration was studied using a spectrometer with a fixed integration time. Spectral measurements of the luminescent solution and the blank solution (distilled water only) were taken to deconvolve the Cherenkov and quinine contribution to the overall emission spectrum. Using a CCD camera, intensity profiles were obtained for the blank and the 1.00 g l −1 solutions to compare them with the dose predicted by a treatment planning system. The luminescent intensity of the samples was found to follow a logarithmic trend as a function of the quinine concentration. Based on the spectral deconvolution of the 1.00 g l −1 solution, 52.4% ± 0.7% and 52.7% ± 0.7% of the signal in the visible range results from the quinine emission at 6 and 23 MV, respectively. The remaining fraction of the spectrum is due to the Cherenkov light that has not been converted. The fraction of the Cherenkov emission produced between 250 nm and 380 nm in the water and that was absorbed by the fluorophore reached 24.8% and 9.4% respectively at 6 and 23 MV. X-ray stimulated fluorescence of the quinine was then proven to be the principal cause to the increased total light output compared to the water-only signal. This new information reinforces the direct correlation of the solution intensity to the dose deposition.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095027
Dosimetric properties of colloidal quantum dot-based systems for scintillation dosimetry
Colloidal quantum dots (cQDs) are starting to be used in radiation detection, either combined with an organic fluorophore or used as a sole luminescent material. In the latter case, only few studies report on cQD-based detectors for medical applications, especially for scintillation dosimetry in radiation therapy. Moreover, most of these studies focus on the effects of radiation on cQD photoluminescence but do not look into the properties of the scintillation signal itself. The present article provides a study of those cQD scintillation properties not previously investigated including the linearity of the signal as a function of dose, the signal dose rate and beam energy dependencies. The latter was also characterized for the commercially available scintillating fiber BCF-60 and liquid scintillator Ultima Gold. CdSe multishell cQDs in two physical forms were used as a sensitive dosimeter volume: a cQD powder to constitute a fiber optic based dosimeter and cQD liquid dispersions to be volumetric dosimeters. The signal linearity was assessed with a R 2 coefficient >0.999 over a clinically relevant dose range at kV and MV beam energies. The cQDs had a good overall dose rate independence, with a change from the relative dose of 1% at MV energies and 2% at kV energies, of their scintillation output when irradiated with an orthovoltage device and a linear accelerator. Regarding the beam energy dependence, the cQD powder had the highest dependence amongst all the scintillators compared, the 120 kVp light output being up to almost 4 times that of the 6 MV beam. The smallest effect of the beam energy was reported for the cQD alkylbenzene liquid dispersion, having a variation of light signal normalized to 6 MV of 15% that is even less than for BCF-60 and Ultima Gold.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095027
Dosimetric properties of colloidal quantum dot-based systems for scintillation dosimetry
Colloidal quantum dots (cQDs) are starting to be used in radiation detection, either combined with an organic fluorophore or used as a sole luminescent material. In the latter case, only few studies report on cQD-based detectors for medical applications, especially for scintillation dosimetry in radiation therapy. Moreover, most of these studies focus on the effects of radiation on cQD photoluminescence but do not look into the properties of the scintillation signal itself. The present article provides a study of those cQD scintillation properties not previously investigated including the linearity of the signal as a function of dose, the signal dose rate and beam energy dependencies. The latter was also characterized for the commercially available scintillating fiber BCF-60 and liquid scintillator Ultima Gold. CdSe multishell cQDs in two physical forms were used as a sensitive dosimeter volume: a cQD powder to constitute a fiber optic based dosimeter and cQD liquid dispersions to be volumetric dosimeters. The signal linearity was assessed with a R 2 coefficient >0.999 over a clinically relevant dose range at kV and MV beam energies. The cQDs had a good overall dose rate independence, with a change from the relative dose of 1% at MV energies and 2% at kV energies, of their scintillation output when irradiated with an orthovoltage device and a linear accelerator. Regarding the beam energy dependence, the cQD powder had the highest dependence amongst all the scintillators compared, the 120 kVp light output being up to almost 4 times that of the 6 MV beam. The smallest effect of the beam energy was reported for the cQD alkylbenzene liquid dispersion, having a variation of light signal normalized to 6 MV of 15% that is even less than for BCF-60 and Ultima Gold.
- 1 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (17) , 175012
Characterization of a binary system composed of luminescent quantum dots for liquid scintillation
Scintillation dosimetry has evolved towards utilizing 3D liquid dosimeters to perform quality assurance verification of complex treatment configuration for photon, electron and proton beams. However, most of the fluorophores utilized in these dosimeters are alike and present limitations. This study aims to establish the profile of CdSe colloidal quantum dots (cQDs) that were given the role of the fluorophore in a binary liquid scintillation system. We chose to investigate the cQDs because of their wide absorption spectrum, the tunability of their absorption and emission spectra with respect to their size and composition, and their ability to function as an effective energy transfer intermediate. The scintillation intensity and spectral response of three organic solvent-based liquid cQD dispersions have been investigated upon irradiation with kV and MV photon beams. The solvents used to disperse the cQDs were hexane, toluene and linear alkylbenzene. The scintillation efficiency of the cQD dispersions has proven to be dependent on the nature of the solvent, the alkylbenzene cQD liquid dispersion having the brightest light emission of the three solutions, for an equivalent deposited dose in the scintillator. Its light output was found to reach a tenth of the light intensity of a commercial liquid scintillator, Ultima Gold, irradiated under the same conditions. This cQD dispersion also demonstrated a remarkable energy transfer to the cQDs, only 5% of its intensity being due to Cherenkov light production in the solvent. Overall, these results indicate that the alkylbenzene cQD liquid dispersion could be the best choice for a potential cQD-based liquid scintillator.
- 1 September 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (17) , 175012
Characterization of a binary system composed of luminescent quantum dots for liquid scintillation
Scintillation dosimetry has evolved towards utilizing 3D liquid dosimeters to perform quality assurance verification of complex treatment configuration for photon, electron and proton beams. However, most of the fluorophores utilized in these dosimeters are alike and present limitations. This study aims to establish the profile of CdSe colloidal quantum dots (cQDs) that were given the role of the fluorophore in a binary liquid scintillation system. We chose to investigate the cQDs because of their wide absorption spectrum, the tunability of their absorption and emission spectra with respect to their size and composition, and their ability to function as an effective energy transfer intermediate. The scintillation intensity and spectral response of three organic solvent-based liquid cQD dispersions have been investigated upon irradiation with kV and MV photon beams. The solvents used to disperse the cQDs were hexane, toluene and linear alkylbenzene. The scintillation efficiency of the cQD dispersions has proven to be dependent on the nature of the solvent, the alkylbenzene cQD liquid dispersion having the brightest light emission of the three solutions, for an equivalent deposited dose in the scintillator. Its light output was found to reach a tenth of the light intensity of a commercial liquid scintillator, Ultima Gold, irradiated under the same conditions. This cQD dispersion also demonstrated a remarkable energy transfer to the cQDs, only 5% of its intensity being due to Cherenkov light production in the solvent. Overall, these results indicate that the alkylbenzene cQD liquid dispersion could be the best choice for a potential cQD-based liquid scintillator.
- Open Access
- 1 October 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (10) , 105011
Robust shell passivation of CdSe colloidal quantum dots to stabilize radioluminescence emission
Systematic characterization of semiconductor colloidal quantum dots (cQDs) response to ionizing radiation must be performed to use them in radiation detection. In this study, the robustness of multi-shell (MS) and core/shell (CS) cQDs was investigated under irradiation. Radioluminescence (RL) measurements with kV and MV photon beams revealed a better resistance of MS cQDs to ionizing radiation, with their spectra fluctuating by barely ∼ 1 nm. A systematic signal recovery between subsequent irradiations was noticed for MS cQDs only. A beam energy dependence of the RL stability was detected between kV and MV energies. At the same point of dose cumulated, the RL signal loss for the kV beams was observed to be ∼6-7% smaller than that of the MV beam, for both types of cQDs. These results demonstrate that MS cQDs are better candidates as ionizing radiation sensors than CS cQDs, especially in the kV energy range.
- 1 October 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (10) , 105011
Open AccessRobust shell passivation of CdSe colloidal quantum dots to stabilize radioluminescence emission
Systematic characterization of semiconductor colloidal quantum dots (cQDs) response to ionizing radiation must be performed to use them in radiation detection. In this study, the robustness of multi-shell (MS) and core/shell (CS) cQDs was investigated under irradiation. Radioluminescence (RL) measurements with kV and MV photon beams revealed a better resistance of MS cQDs to ionizing radiation, with their spectra fluctuating by barely ∼ 1 nm. A systematic signal recovery between subsequent irradiations was noticed for MS cQDs only. A beam energy dependence of the RL stability was detected between kV and MV energies. At the same point of dose cumulated, the RL signal loss for the kV beams was observed to be ∼6-7% smaller than that of the MV beam, for both types of cQDs. These results demonstrate that MS cQDs are better candidates as ionizing radiation sensors than CS cQDs, especially in the kV energy range.