ALAna Carolina Oliveira Lima

Ana Carolina Oliveira Lima

*This is an algorithmically generated author record based on publicly available information.

Ana Carolina Oliveira Lima has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hybrid Active Teaching Methodology for Learning Development

    by Renan Lima Baima, Ana Carolina Oliveira Lima, Emilia Oliveira Lima Leal, Tiago Miguel Pereira Candeias, Silvia Maria Dias Pedro Rebouças

    The primary objective is to emphasize the merits of active methodologies and cross-disciplinary curricula in Requirement Engineering. This direction promises a holistic and applied trajectory for Computer Engineering education, supported by the outcomes of our case study, where artifact-centric learning proved effective, with 73% of students achieving the highest grade. Self-assessments further corroborated academic excellence, emphasizing students' engagement in skill enhancement and knowledge acquisition.


  • Trajectory Correction for Visually Impaired Athletes on 100 m Paralympic Races

    by Luiz Alberto Queiroz Cordovil Júnior, Gabriel Tadayoshi Rodrigues Oka, Moisés Pereira Bastos, Renan Lima Baima, Nilton Cesar Ferst, Ana Carolina Oliveira Lima, Ana Isabel Martins, Nelson Pacheco Rocha


  • A Tracking Topology to Support a Trajectory Monitoring System Directed at Helping Visually Impaired on Paralympic Athletics

    by Luiz Alberto Queiroz Cordovil Júnior, Renan Lima Baima, Gabriel Tadayoshi Rodrigues Oka, Ana Carolina Oliveira Lima, Moisés Pereira Bastos, Ana Isabel Martins, Nelson Pacheco Rocha


  • Open Access

    A Digital Solution to Surpass Incidents on 100m Sprint for Paralympic Visually Impaired Athletes

    by Stefane Rego, Emília Leal, Ana Isabel Martins, Ana Lima, Nilton Cesar, Luiz Júnior, Nelson P. Rocha

    There is a great concern in the Paralympic field about the occurrence of incidents such as falls and disqualifications among other problems involving visually impaired athletes. The main goal of the study reported by this paper was to identify the incidents related to the orientation process based on the connection by a rope between an athlete and the respective guide on the 100m sprint for Paralympic visually impaired athletes. This allowed to elicit the requirements of a possible solution based on information technologies to optimize orientation in running tracks. To identify the type of incidents, 186 official championship videos of T11 to T13 sports’ classes of the 100m sprint races were analyzed, and all incidents were registered. The incidents were defined according to the International Paralympic Committee rules and include errors or fails, performance issues, unfinished races, and disqualifications. The results show that in almost half of the races there were incidents that affected the dynamics of the athlete-guide pair. Therefore, the results indicate difficulties in performing a synchronized and incidents free race using only one rope to guide the visually impaired athletes, and make it clear that they would benefit from a digital solution to improve their perception of what surrounds them, namely by providing information about the running tracks, routes and locations. These results could impact the Paralympic sport, namely by minimizing the interferences of the guides on the performance of the visually impaired athletes.


  • Application of the ISO 9241-171 Standard and Usability Inspection Methods for the Evaluation of Assistive Technologies for Individuals with Visual Impairments

    by Ana Carolina Oliveira Lima, Maria de Fátima Vieira, Ana Isabel Martins, Lucilene Ferreira Mouzinho, Nelson Pacheco Rocha


  • Vibrotactile sensory substitution on personal navigation: Remotely controlled vibrotactile feedback wearable system to aid visually impaired

    by Thiago Silva Filgueiras, Ana Carolina Oliveira Lima, Renan Lima Baima, Gabriel Tadayoshi Rodrigues Oka, Luiz Alberto Queiroz Cordovil, Moises Pereira Bastos

    Tactile sensory substitution is a field of science and engineering that studies the intersection of neuroscience, haptics, human sensory physiology, and the function of perception. Tactile feedback (e.g., vibrations and pressure) provides one solution to aid visually impaired. This paper presents the development and assessment of a simple pilot wearable system with vibrotactile feedback. We followed an iterative approach in which the proposed system went through user evaluations and technical refinements. The final prototype includes vibrotactile feedback for orientation with two unobtrusive actuators in contact with each arm of the user. Sixteen blindfolded sighted were invited to conduct travel experiments in a mutable labyrinth. Their evaluation was registered in video record. A post-experiment interview regarding the usefulness of the proposed system for the participants was performed. Our study indicates our pilot system is useful to provide unobtrusive indications of the level of proximity of an obstacle and the personal orientation in a controlled environment. The goal is to use the vibrotactile feedback on navigation of visually impaired people and inform the research community and society about the capabilities of these navigation systems. It is the first study involving vibrotactile feedback and we will consider the results for future works. We consider this work important because the projects involving vibrotactile in literature cover mainly the GPS technologies, in outdoor environments. We intend to prove that vibrotactile feedback is a good option in indoor and small environment, as house and office, in local application, using low cost enhancements in known objects at indoor environments. The study provided great empirical data and meaningful insight and information for the design of projects involving technologies of vibration for future application.


  • Microtuators of SMA for Braille display system

    by D. R. Chaves, I. L. Peixoto, A.C.O. Lima, M. F. Vieira, C. J. de Araujo

    This paper presents a new configuration of microactuator based on the shape memory alloys (SMA) NiTi (Nickel-Titanium), that it can be applied in touch interfaces high resolution. The essentials criterions for the project of a tactile display and factors as time of reply and force mechanics on the Braille display surface had been satisfied. The time was 1s for the displacement of the pin Braille of the order of 0.7 mm, from a current level around 350 mA, and the force for the microactuator was superior 120 mN.


  • Comparative analysis of tactile sensitivity between blind, deaf and unimpaired people

    by Ilton L. Barbacena, Ana Carolina Oliveira Lima, Alessio T. Barros, Raimundo C.S. Freire, Jose R. Pereira

    This paper presents the methodological procedures and the results of a tactile sensitivity analysis to vibrotactile stimuli. The results were obtained through the analyses between the rightness mean while identifying the target frequency, among the following characteristics: visually and hearing impaired people as well as unimpaired ones; visually and hearing impaired men and women and unimpaired ones; visually and hearing impaired children, teenagers and adults as well as unimpaired ones; visually and hearing impaired people with congenital and acquired deficiency. This is an expanded version of a paper presented at the 3rd IEEE International Workshop on Medical Measurements and Applications, 9?10 May 2008, Ottawa, ON, Canada.


  • Comparative Analysis of Tactile Sensitivity between Blind, Deaf and Unimpaired People

    by Ilton L. Barbacena, Ana C. O. Lima, Alessio T. Barros, Raimundo C. S. Freire, Jose R. Pereira

    - This paper presents the methodological procedures and the results of a tactile sensitivity analysis to vibrotactile stimuli. The procedure consists in the attempt of a visual, hearing impaired person as well as an unimpaired one, initially trained, to identify three vibrotactile standard stimuli ( target frequency from 17.8, 31.6 and 56.2 Hz) having as starting point the sending of an initial stimulus (initial frequency ). The results were obtained through the analyses between the rightness mean while identifying the target frequency, among 1) visually and hearing impaired people as well as unimpaired ones: 2) visually and hearing impaired men and women and unimpaired ones: 3) visually and hearing impaired children, teenagers and adults as well as unimpaired ones; and 4) people with congenital and acquired blindness or deafness. A comparative analysis was done between the tactile sensitivity of the forefinger and the thumb, middle, ring and little fingers, as well as a comparison between the sensitivities in the target frequencies in the three groups (blind, deaf and unimpaired people). The results assessment obtained in the experiment was based on the t-student statistical method for paired and independent samples and ANOVA with a classification criterion.


  • Comparative Analysis of Tactile Sensibility between the Fingers in Vibrotactile Stimulus Recognition

    by Ana Carolina Oliveira Lima, Raimundo Carlos Silverio Freire, Francisco Marcos de Assis, Rodrigo Carlos Silva e Silva, Anderson Fabricio Ramos de Souza

    It is presented in this paper the methodological procedures for the accomplishment of psychophysics tests with blind people aiming for evaluating the tactile system discriminative capability towards vibrating stimuli. It will also be presented and evaluated the results of tests with blind people. The procedure for these tests consist of making the blind person try to identify a standard vibrate stimulus (target frequency) after an initial stimulus is sent (initial frequency). Three target frequencies were chosen and the initial stimulus is a frequency, randomly chosen, higher or lower than the target frequency. The procedure starts when a blind person is trained to identify a target frequency. After that, an initial frequency is set, and the blind person may increase or decrease the frequency until the person believes achieved the target frequency. This test is carried out to evaluate and comparison of the tactile sensibility for all fingers on the hand.