JHJohn A. Heyman

John A. Heyman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John A. Heyman has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A biocompatible surfactant film for stable microfluidic droplets

    by Brendan T. Deveney, John A. Heyman, Raoul G. Rosenthal, David A. Weitz, Jörg G. Werner

    Covalent association between a fluorinated and a hydrophilic polymer forms an amphiphilic film at water–oil interfaces for armored droplets that are stable during thermal cycling, cell and bacteria incubation without coalescence or interference.


  • Open Access

    The Rapid Generation of Cell-Laden, FACS-Compatible Collagen Gels

    by Yi Xiao, Qiaoling Huang, Jesse W. Collins, Julie Brouchon, Jeffery A. Nelson, Zachary Niziolek, Alison O’neil, Fangfu Ye, David A. Weitz, John A. Heyman

    A three-dimensional cell culture in hydrogel beads can support cell growth and differentiation into multi-cellular structures, and these gel beads could be used as building blocks for more complex three-dimensional assemblies. This requires hydrogel beads that are robust enough to sort via FACS yet can be degraded by cell-secreted enzymes. Collagen polymers form hydrogels that are excellent cell growth substrates; however, collagen-containing hydrogel beads typically include additional polymers that limit their degradation. Here, we introduce a simple microfluidic method to generate robust, sortable, cell-laden collagen hydrogel beads. We use on-device pH control to trigger collagen gelation without exposing cells to low pH, ensuring high cell viability. We fabricate microfluidic devices to generate droplets with a wide size range, as demonstrated by production of both small (~55 µm diameter) and large (~300 µm diameter) collagen gels. All hydrogels are sufficiently robust to allow for sorting using FACS. Moreover, high cell viability is maintained throughout the process.


  • Open Access

    High-throughput single-cell antibody secretion quantification and enrichment using droplet microfluidics-based FRET assay

    by Justina Rutkauskaite, Simon Berger, Stavros Stavrakis, Oliver Dressler, John Heyman, Xavier Casadevall i Solvas, Andrew Demello, Linas Mazutis


  • Open Access

    Linear triglycerol-based fluorosurfactants show high potential for droplet-microfluidics-based biochemical assays

    by Mohammad Suman Chowdhury, Wenshan Zheng, Abhishek Kumar Singh, Irvine Lian Hao Ong, Yong Hou, John A. Heyman, Abbas Faghani, Esther Amstad, David A. Weitz, Rainer Haag

    We decoupled the influence of different spatial geometries of oligoglycerol-based head groups and contributed to the goal of rational fluorosurfactant design for droplet microfluidics-based water-in-oil emulsions and suited applications.


  • Open Access

    Rapid isolation of antigen-specific B-cells using droplet microfluidics

    by Ruihua Ding, Kuo-Chan Hung, Anindita Mitra, Lloyd W. Ung, Daniel Lightwood, Ran Tu, Dale Starkie, Liheng Cai, Linas Mazutis, Shaorong Chong, et al.

    We use a droplet-microfluidics-based platform to rapidly identify and isolate individual primary cells that secrete desired antibodies. We then retrieve the antibody-encoding sequences and create recombinant antibodies that bind the target protein.


  • Droplet encapsulation improves accuracy of immune cell cytokine capture assays

    by Yuan Yuan, Julie Brouchon, J. Mauricio Calvo-Calle, Jing Xia, Li Sun, Xu Zhang, Kiera L. Clayton, Fangfu Ye, David A. Weitz, John A. Heyman

    Quantification of cell-secreted molecules, e.g., cytokines, is fundamental to the characterization of immune responses. Cytokine capture assays that use engineered antibodies to anchor the secreted molecules to the secreting cells are widely used to characterize immune responses because they allow both sensitive identification and recovery of viable responding cells. However, if the cytokines diffuse away from the secreting cells, non-secreting cells will also be identified as responding cells. Here we encapsulate immune cells in microfluidic droplets and perform in-droplet cytokine capture assays to limit the diffusion of the secreted cytokines. We use microfluidic devices to rapidly encapsulate single natural killer NK-92 MI cells and their target K562 cells into microfluidic droplets. We perform in-droplet IFN-γ capture assays and demonstrate that NK-92 MI cells recognize target cells within droplets and become activated to secrete IFN-γ. Droplet encapsulation prevents diffusion of secreted products to neighboring cells and dramatically reduces both false positives and false negatives, relative to assays performed without droplets. In a sample containing 1% true positives, encapsulation reduces, from 94% to 2%, the number of true-positive cells appearing as negatives; in a sample containing 50% true positives, the number of non-stimulated cells appearing as positives is reduced from 98% to 1%. After cells are released from the droplets, secreted cytokine remains captured onto secreting immune cells, enabling FACS-isolation of populations highly enriched for activated effector immune cells. Droplet encapsulation can be used to reduce background and improve detection of any single-cell secretion assay.


  • DNAzyme-powered nucleic acid release from solid supports

    by Ting Cao, Yongcheng Wang, Ye Tao, Lexiang Zhang, Ying-Lin Zhou, Xin-Xiang Zhang, John A. Heyman, David A. Weitz

    Here, we demonstrate use of a Mg2+-dependent, site-specific DNA enzyme (DNAzyme) to cleave oligos from polyacrylamide gel beads, which is suitable for use in drop-based assays.


  • Rapid additive-free bacteria lysis using traveling surface acoustic waves in microfluidic channels

    by Haiwei Lu, Kirk Mutafopulos, John A. Heyman, Pascal Spink, Liang Shen, Chaohui Wang, Thomas Franke, David A. Weitz

    We report an additive-free method to lyse bacteria and extract nucleic acids and protein using a traveling surface acoustic wave (TSAW) coupled to a microfluidic device. We characterize the effects of the TSAW on E. coli by measuring the viability of cells exposed to the sound waves and find that about 90% are dead. In addition, we measure the protein and nucleic acids released from the cells and show that we recover about 20% of the total material. The lysis method should work for all types of bacteria. These results demonstrate the feasibility of using TSAW to lyse bacteria in a manner that is independent of the type of bacteria.


  • Open Access

    Dendronized fluorosurfactant for highly stable water-in-fluorinated oil emulsions with minimal inter-droplet transfer of small molecules

    by Mohammad Suman Chowdhury, Wenshan Zheng, Shalini Kumari, John Heyman, Xingcai Zhang, Pradip Dey, David A. Weitz, Rainer Haag

    Fluorosurfactant-stabilized microfluidic droplets are widely used as pico- to nanoliter volume reactors in chemistry and biology. However, current surfactants cannot completely prevent inter-droplet transfer of small organic molecules encapsulated or produced inside the droplets. In addition, the microdroplets typically coalesce at temperatures higher than 80 °C. Therefore, the use of droplet-based platforms for ultrahigh-throughput combination drug screening and polymerase chain reaction (PCR)-based rare mutation detection has been limited. Here, we provide insights into designing surfactants that form robust microdroplets with improved stability and resistance to inter-droplet transfer. We used a panel of dendritic oligo-glycerol-based surfactants to demonstrate that a high degree of inter- and intramolecular hydrogen bonding, as well as the dendritic architecture, contribute to high droplet stability in PCR thermal cycling and minimize inter-droplet transfer of the water-soluble fluorescent dye sodium fluorescein salt and the drug doxycycline.


  • Sensitive and predictable separation of microfluidic droplets by size using in-line passive filter

    by Ruihua Ding, W. Lloyd Ung, John A. Heyman, David A. Weitz

    Active manipulation of droplets is crucial in droplet microfluidics. However, droplet polydispersity decreases the accuracy of active manipulation. We develop a microfluidic “droplet filter” that accurately separates droplets by size. The droplet filter has a sharp size cutoff and is capable of distinguishing droplets differing in volume by 20%. A simple model explains the behavior of the droplets as they pass through the filter. We show application of the filter in improving dielectric sorting efficiency.