Amir Sepehr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amir Sepehr has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Edris Pouresmaeil
Aalto University
8 shared publications - Joao P. S. Catalao
University of Porto
5 shared publications Majid Mehrasa
4 shared publicationsMousa Marzband
3 shared publications- Bahram Pournazarian
Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
2 shared publications - Jorma Kyyra
Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, Espoo, Finland
2 shared publications
Latest Publications
- Open Access
- 2 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (3) , 2121-2131
Employing Machine Learning for Enhancing Transient Stability of Power Synchronization Control During Fault Conditions in Weak Grids
Grid-connected converters are exposed to the loss of synchronisation with the grid during severe voltage sags particularly when operating under weak grid condition which introduces voltage and frequency volatility. This paper presents employing machine learning methods besides modifying the converter control scheme to enhance the transient stability of power synchronization control (PSC). For early detection of synchronization instability of PSC to provide adequate time for taking correcting control actions, an encoder stacked classifier is proposed which is trained to be robust against data corruption and added noise. Then, by integrating the proposed instability detection scheme to the synchronization loop of PSC, a phase freezing mode is introduced to avoid losing synchronism during grid faults. It is disclosed that the frozen synchronization loop, which is activated by the proposed instability detection scheme, can ensure synchronization stability of PSC. Time-domain simulations are conducted to confirm the presented findings.
- 2 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (3) , 2121-2131
Open AccessEmploying Machine Learning for Enhancing Transient Stability of Power Synchronization Control During Fault Conditions in Weak Grids
Grid-connected converters are exposed to the loss of synchronisation with the grid during severe voltage sags particularly when operating under weak grid condition which introduces voltage and frequency volatility. This paper presents employing machine learning methods besides modifying the converter control scheme to enhance the transient stability of power synchronization control (PSC). For early detection of synchronization instability of PSC to provide adequate time for taking correcting control actions, an encoder stacked classifier is proposed which is trained to be robust against data corruption and added noise. Then, by integrating the proposed instability detection scheme to the synchronization loop of PSC, a phase freezing mode is introduced to avoid losing synchronism during grid faults. It is disclosed that the frozen synchronization loop, which is activated by the proposed instability detection scheme, can ensure synchronization stability of PSC. Time-domain simulations are conducted to confirm the presented findings.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Harmonic Stability Analysis of Grid-Connected Converters with Power Synchronization Control
Integration of converter-based resources into weak grids brings new concerns regarding the harmonic stability of modern power systems. This paper studies the harmonic stability and impedance characteristics of power synchronization control (PSC) which has been introduced for control of converters under weak grid operating conditions. This paper addresses this issue by studying the admittance characteristics of PSC based on the dynamics of the control scheme, the delay and the sampling frequency of the control system, and the linearized model of the grid-connected converter. Next, a critical grid inductance is derived, and necessary conditions for achieving harmonic stability are introduced. Time-domain simulations are carried out to support the proposed harmonic stability analysis.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Harmonic Stability Analysis of Grid-Connected Converters with Power Synchronization Control
Integration of converter-based resources into weak grids brings new concerns regarding the harmonic stability of modern power systems. This paper studies the harmonic stability and impedance characteristics of power synchronization control (PSC) which has been introduced for control of converters under weak grid operating conditions. This paper addresses this issue by studying the admittance characteristics of PSC based on the dynamics of the control scheme, the delay and the sampling frequency of the control system, and the linearized model of the grid-connected converter. Next, a critical grid inductance is derived, and necessary conditions for achieving harmonic stability are introduced. Time-domain simulations are carried out to support the proposed harmonic stability analysis.
- 1 October 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 111, 300-314
Control of power electronics-based synchronous generator for the integration of renewable energies into the power grid
- 1 October 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 111, 300-314
Control of power electronics-based synchronous generator for the integration of renewable energies into the power grid
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of Grid-Tied Converters for Integration of Renewable Energy Sources into the Weak Grids
This paper proposes a developed control technique for integration of renewable energy sources into the weak grids. The developed controller alleviates the negative impact of weak grid operating condition on the stability of interface converters by mean of impedance reshaping technique. Furthermore, the proposed controller provides virtual inertia to support the power grid stability. Satisfactory and stable operation of the interface converter as well as providing virtual inertia under weak grid condition with high penetration level of RESs, are the main contributions of this paper. Comparative simulation results are presented to demonstrate and verify the effectiveness of the proposed control technique.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of Grid-Tied Converters for Integration of Renewable Energy Sources into the Weak Grids
This paper proposes a developed control technique for integration of renewable energy sources into the weak grids. The developed controller alleviates the negative impact of weak grid operating condition on the stability of interface converters by mean of impedance reshaping technique. Furthermore, the proposed controller provides virtual inertia to support the power grid stability. Satisfactory and stable operation of the interface converter as well as providing virtual inertia under weak grid condition with high penetration level of RESs, are the main contributions of this paper. Comparative simulation results are presented to demonstrate and verify the effectiveness of the proposed control technique.
- 1 January 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 166, 18-28
Control technique for the operation of grid-tied converters with high penetration of renewable energy resources
- 1 January 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 166, 18-28
Control technique for the operation of grid-tied converters with high penetration of renewable energy resources
- Open Access
Synchronous Resonant Control Technique to Address Power Grid Instability Problems Due to High Renewables Penetration
This paper presents a synchronous resonant control strategy based on the inherent characteristics of permanent magnet synchronous generators (PMSG) for the control of power converters to provide stable operating conditions for the power grid under high penetration of renewable energy resources (RERs). The proposed control technique is based on the small signal linearization of a dynamic model with grid specifications, load-current-based voltages, and power converter currents. A combination of the linearized dynamic model with the PMSG swing equation and resonant controller leads to a control technique with synchronous features and appropriate inertia for the control of converter-based power generators. As the main contribution of this work, an extra functionality is proposed in the control loop of the proposed model to solve the inherent inconveniences of conventional synchronous generators. Also, a comprehensive collaboration between interfaced converter specifications and PMSG features is achieved as another contribution of the proposed control technique, and this can guarantee accurate performance under various conditions. A current perturbation curve is introduced to assess the variations of the grid frequency and voltage magnitude under operation of the interfaced converters controlled by the proposed control technique. Moreover, by taking into account the load-based voltages, the effects of the current perturbation components are investigated. The proposed model is simulated in MATLAB/Simulink environment to verify the high performance of the proposed control technique over the other existing control methods.
Open AccessSynchronous Resonant Control Technique to Address Power Grid Instability Problems Due to High Renewables Penetration
This paper presents a synchronous resonant control strategy based on the inherent characteristics of permanent magnet synchronous generators (PMSG) for the control of power converters to provide stable operating conditions for the power grid under high penetration of renewable energy resources (RERs). The proposed control technique is based on the small signal linearization of a dynamic model with grid specifications, load-current-based voltages, and power converter currents. A combination of the linearized dynamic model with the PMSG swing equation and resonant controller leads to a control technique with synchronous features and appropriate inertia for the control of converter-based power generators. As the main contribution of this work, an extra functionality is proposed in the control loop of the proposed model to solve the inherent inconveniences of conventional synchronous generators. Also, a comprehensive collaboration between interfaced converter specifications and PMSG features is achieved as another contribution of the proposed control technique, and this can guarantee accurate performance under various conditions. A current perturbation curve is introduced to assess the variations of the grid frequency and voltage magnitude under operation of the interfaced converters controlled by the proposed control technique. Moreover, by taking into account the load-based voltages, the effects of the current perturbation components are investigated. The proposed model is simulated in MATLAB/Simulink environment to verify the high performance of the proposed control technique over the other existing control methods.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Angular Frequency Dynamic-Based Control Technique of a Grid-Interfaced Converter Emulated by a Synchronous Generator
In this paper, an angular frequency dynamic-based control technique is proposed to control interfaced converters between the power grid and renewable energy sources. The proposed control technique can guarantee a stable operation of power grid under high penetration of renewable energy resources through providing the required inertia properties. The synchronous generator characteristics combined with the basic dynamic model of the interfaced converter can shape a second order derivative of the grid angular frequency consisting of converter power and virtual mechanical power derivative with embedded virtual inertia to prevent instability from the power grid as well as to generate active and reactive power with appropriate inertia. Simulation analyses are performed in Matlab/Simulink to attest the high performance of the proposed control technique.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Angular Frequency Dynamic-Based Control Technique of a Grid-Interfaced Converter Emulated by a Synchronous Generator
In this paper, an angular frequency dynamic-based control technique is proposed to control interfaced converters between the power grid and renewable energy sources. The proposed control technique can guarantee a stable operation of power grid under high penetration of renewable energy resources through providing the required inertia properties. The synchronous generator characteristics combined with the basic dynamic model of the interfaced converter can shape a second order derivative of the grid angular frequency consisting of converter power and virtual mechanical power derivative with embedded virtual inertia to prevent instability from the power grid as well as to generate active and reactive power with appropriate inertia. Simulation analyses are performed in Matlab/Simulink to attest the high performance of the proposed control technique.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Stability Analysis ofa Synchronous Generator-Based Control Technique used in Large-Scale Grid Integration of Renewable Energy
-A synchronous generator (SG)-based control technique is proposed in this paper to force the grid voltage magnitude and frequency to follow the desired values under high penetration of renewable energy sources. A more detailed relationship between power dynamic model and SGs characteristics has been considered in the proposed control strategy. The active and reactive power error-based curve of the proposed control technique is evaluated in detail. Besides, the grid angular frequency error based on the proposed control technique performance is assessed in the next step. Simulation is employed in Matlab/Simulink to verify the operation of the proposed control technique in power converters for large-scale integration of renewable energy sources into the power grids.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Stability Analysis ofa Synchronous Generator-Based Control Technique used in Large-Scale Grid Integration of Renewable Energy
-A synchronous generator (SG)-based control technique is proposed in this paper to force the grid voltage magnitude and frequency to follow the desired values under high penetration of renewable energy sources. A more detailed relationship between power dynamic model and SGs characteristics has been considered in the proposed control strategy. The active and reactive power error-based curve of the proposed control technique is evaluated in detail. Besides, the grid angular frequency error based on the proposed control technique performance is assessed in the next step. Simulation is employed in Matlab/Simulink to verify the operation of the proposed control technique in power converters for large-scale integration of renewable energy sources into the power grids.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 356-361
A noninvasive on-line failure prediction technique for aluminum electrolytic capacitors in photovoltaic grid-connected inverters
Since the electrolytic capacitors are mainly responsible for breakdowns in power electronics converters, they usually determine the overall lifetime. Their failure is due to the deterioration of their dielectric, the production of gases, and, eventually, their explosion. The deterioration process leads to a decrease in its capacitance value and simultaneously, an increase in the capacitor equivalent series resistance (ESR). In this paper, a novel noninvasive technique for failure prediction of the electrolytic capacitors in grid-connected photovoltaic inverters is presented, which can easily be applied online and even in the real time. The technique is based on the DC-link voltage measurement, current calculation, and extracting the current integral and the voltage change during switching intervals. Then, the capacitance can be calculated using the recursive least squares method. Although the estimation results are influenced by the temperature at which the measurement is performed, and the results are dependent on the operating conditions, but the proposed method is modified to obviate the above distorting factors effectively. The proposed technique is simple to apply, accurate and does not need to any extra hardware. Also it can be adapted for any other inverter based applications. The performance of the proposed method is verified by the simulation and experimental results.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 356-361
A noninvasive on-line failure prediction technique for aluminum electrolytic capacitors in photovoltaic grid-connected inverters
Since the electrolytic capacitors are mainly responsible for breakdowns in power electronics converters, they usually determine the overall lifetime. Their failure is due to the deterioration of their dielectric, the production of gases, and, eventually, their explosion. The deterioration process leads to a decrease in its capacitance value and simultaneously, an increase in the capacitor equivalent series resistance (ESR). In this paper, a novel noninvasive technique for failure prediction of the electrolytic capacitors in grid-connected photovoltaic inverters is presented, which can easily be applied online and even in the real time. The technique is based on the DC-link voltage measurement, current calculation, and extracting the current integral and the voltage change during switching intervals. Then, the capacitance can be calculated using the recursive least squares method. Although the estimation results are influenced by the temperature at which the measurement is performed, and the results are dependent on the operating conditions, but the proposed method is modified to obviate the above distorting factors effectively. The proposed technique is simple to apply, accurate and does not need to any extra hardware. Also it can be adapted for any other inverter based applications. The performance of the proposed method is verified by the simulation and experimental results.