Donghyuk Yun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Donghyuk Yun has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Sanghyeon Baeg
Department of Electronic Engineering, University of Hanyang, 55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do 15588, South Korea
4 shared publicationsKyungbae Park
3 shared publications- Myungsang Park
Department of Electronic Engineering, Hanyang University, Ansan, Gyeonggi-do, Republic of Korea
3 shared publications - Sanghyeon Baeg
Department of Electronics Engineering, Hanyang University, Ansan, Republic of Korea
3 shared publications Shi-Jie Wen
Cisco Systems Inc., San Jose, CA, USA
3 shared publications- Chulseung Lim
SAMSUNG ELECTRONICS Co., Ltd, Hwaseong-si, Republic of Korea
2 shared publications
Latest Publications
- 28 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 69 (5) , 2338-2345
Divulge of Root Cause Failure in Individual Cells of 2× nm Technology DDR4 DRAM at Operating Temperature
This article reveals the leakage mechanisms corresponding to the dominant leakage path of individual tail cells in$2\times $ nm technology double data rate (DDR)4 DRAM at operating temperature. For leakage path determination, activation energy (${E}_{a}$ ) was used as a tool through its extraction by retention time measurement. To get a wide distribution of${E}_{a}$ , retention testing was performed at the target retention time (10, 15, 20, or 25 s); during this, the number of retentions failed cells were recorded with each temperature. In this experiment, 1.65 e −2 % of the selected bank cells found retention failures. From the total retention failed cells, the selected commonly retention failed cells at the target retention times comprise 1.5 e −3 % of the selected bank cells. From commonly retention failed cells, the distribution of${E}_{a}$ is analyzed with the retention time at room temperature. This analysis reveals that subthreshold, junction, and gate-induced drain leakage (GIDL) leakage paths dominate in 3.48%, 93.89%, and 2.61% of the total retention failed cells, respectively, at room temperature. Using another experimental approach, retention testing performed at operating temperature on selected 0.07-ppm retention tail cells concludes that GIDL is the dominant leakage path in this device. Correlation between${E}_{a}$ and retention time measured at operating temperature (40 °C, 60 °C, or 80 °C) explored the leakage mechanisms corresponding to${E}_{a}$ of the extracted dominant leakage path (GIDL). These failure leakage mechanisms, dominating on certain values of operating temperature, are divulged as the root cause of failure at that temperature.- 28 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 69 (5) , 2338-2345
Divulge of Root Cause Failure in Individual Cells of 2× nm Technology DDR4 DRAM at Operating Temperature
This article reveals the leakage mechanisms corresponding to the dominant leakage path of individual tail cells in$2\times $ nm technology double data rate (DDR)4 DRAM at operating temperature. For leakage path determination, activation energy (${E}_{a}$ ) was used as a tool through its extraction by retention time measurement. To get a wide distribution of${E}_{a}$ , retention testing was performed at the target retention time (10, 15, 20, or 25 s); during this, the number of retentions failed cells were recorded with each temperature. In this experiment, 1.65 e −2 % of the selected bank cells found retention failures. From the total retention failed cells, the selected commonly retention failed cells at the target retention times comprise 1.5 e −3 % of the selected bank cells. From commonly retention failed cells, the distribution of${E}_{a}$ is analyzed with the retention time at room temperature. This analysis reveals that subthreshold, junction, and gate-induced drain leakage (GIDL) leakage paths dominate in 3.48%, 93.89%, and 2.61% of the total retention failed cells, respectively, at room temperature. Using another experimental approach, retention testing performed at operating temperature on selected 0.07-ppm retention tail cells concludes that GIDL is the dominant leakage path in this device. Correlation between${E}_{a}$ and retention time measured at operating temperature (40 °C, 60 °C, or 80 °C) explored the leakage mechanisms corresponding to${E}_{a}$ of the extracted dominant leakage path (GIDL). These failure leakage mechanisms, dominating on certain values of operating temperature, are divulged as the root cause of failure at that temperature.- 7 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (3) , 558-566
Estimation of the Trap Energy Characteristics of Row Hammer-Affected Cells in Gamma-Irradiated DDR4 DRAM
Dynamic random access memory (DRAM) bits can be erroneously flipped when the row near the error bits is repeatedly accessed with the activate and precharge commands in a process called row hammering. The trap at an Si–SiO 2 interface has been previously reported as the leading cause of such errors. The number of row hammering required for flipping bits initially decreases and then saturates with the increases in the row precharge time ( $t_{\mathrm {RP}}$ ). The DRAM timing parameter is the time interval between an activate command and a precharge command. This study uses the saturation $t_{\mathrm {RP}}$ to estimate the electron emission time of the trap associated with a DRAM bit error. During $t_{\mathrm {RP}}$ time, the traps at the Si–SiO 2 interface emit the trapped electrons. There are more chances of emission as $t_{\mathrm {RP}}$ increases, and less row hammering is needed. The emission time of a trapped electron is experimentally measured herein using commercial DDR4 components. The components are irradiated with gamma rays to induce the interface traps. The trap characteristics are then extracted without requiring an additional measurement setup with a device-level preparation. The trap energies with respect to the mid-band at the Si–SiO 2 interface are 0.118–0.280 eV. The trap energies are distributed within approximately 5.6 kT energies at room temperature.
- 7 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (3) , 558-566
Estimation of the Trap Energy Characteristics of Row Hammer-Affected Cells in Gamma-Irradiated DDR4 DRAM
Dynamic random access memory (DRAM) bits can be erroneously flipped when the row near the error bits is repeatedly accessed with the activate and precharge commands in a process called row hammering. The trap at an Si–SiO 2 interface has been previously reported as the leading cause of such errors. The number of row hammering required for flipping bits initially decreases and then saturates with the increases in the row precharge time ( $t_{\mathrm {RP}}$ ). The DRAM timing parameter is the time interval between an activate command and a precharge command. This study uses the saturation $t_{\mathrm {RP}}$ to estimate the electron emission time of the trap associated with a DRAM bit error. During $t_{\mathrm {RP}}$ time, the traps at the Si–SiO 2 interface emit the trapped electrons. There are more chances of emission as $t_{\mathrm {RP}}$ increases, and less row hammering is needed. The emission time of a trapped electron is experimentally measured herein using commercial DDR4 components. The components are irradiated with gamma rays to induce the interface traps. The trap characteristics are then extracted without requiring an additional measurement setup with a device-level preparation. The trap energies with respect to the mid-band at the Si–SiO 2 interface are 0.118–0.280 eV. The trap energies are distributed within approximately 5.6 kT energies at room temperature.
- Open Access
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 137514-137523
Exploitations of Multiple Rows Hammering and Retention Time Interactions in DRAM Using X-Ray Radiation
The methodological approach of hammering multiple rows is newly proposed to evaluate today’s SDRAMs, employed with in-DRAM mitigation circuits. The multiple rows are selected based on the one-row hammering test (single row hammering without refresh commands) and are exploited to defeat the employed mitigation algorithm. We irradiated the target sample using an X-ray to observe the reactions of the mitigation circuit when various combinations of multiple rows are hammered. The results showed a four times reduction in the number of hammering thresholds under the one-row hammering test. The same radiated sample showed no errors when one or a few rows were hammered due to the built-in mitigation circuit. However, multiple rows hammering (MRH) demonstrated its effectiveness by generating errors despite an active mitigation circuit. In this paper, we explore the X-ray damage results in the aging of the DRAM sample and induces vulnerabilities from the row hammering error perspective. Also, we use the error bits detected by MRH to investigate the coverage pitfalls of the mitigation circuit employed in the sample DRAM. Finally, we newly evaluate the remaining retention time under row hammering stress to explain the coverage loss in the mitigation strategy based solely on hammering counts.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 137514-137523
Open AccessExploitations of Multiple Rows Hammering and Retention Time Interactions in DRAM Using X-Ray Radiation
The methodological approach of hammering multiple rows is newly proposed to evaluate today’s SDRAMs, employed with in-DRAM mitigation circuits. The multiple rows are selected based on the one-row hammering test (single row hammering without refresh commands) and are exploited to defeat the employed mitigation algorithm. We irradiated the target sample using an X-ray to observe the reactions of the mitigation circuit when various combinations of multiple rows are hammered. The results showed a four times reduction in the number of hammering thresholds under the one-row hammering test. The same radiated sample showed no errors when one or a few rows were hammered due to the built-in mitigation circuit. However, multiple rows hammering (MRH) demonstrated its effectiveness by generating errors despite an active mitigation circuit. In this paper, we explore the X-ray damage results in the aging of the DRAM sample and induces vulnerabilities from the row hammering error perspective. Also, we use the error bits detected by MRH to investigate the coverage pitfalls of the mitigation circuit employed in the sample DRAM. Finally, we newly evaluate the remaining retention time under row hammering stress to explain the coverage loss in the mitigation strategy based solely on hammering counts.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P-SE.2-1-SE.2
Study of TID effects on one row hammering using gamma in DDR4 SDRAMs
This paper investigates the Total Ionizing Dose (TID) effect on DDR4 SDRAM, using 60 Co γ-rays. Although retention time degraded with 830 Gy(Si) exposure, no retention errors were observed at the retention time of 64-ms and temperature of 80 °C. Unlike retention time degradation, the significant degradation in one-row hammering threshold was observed. The threshold was reduced by up to 113 k with tRP 53.75 ns-67% reduction from pre-irradiation values.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P-SE.2-1-SE.2
Study of TID effects on one row hammering using gamma in DDR4 SDRAMs
This paper investigates the Total Ionizing Dose (TID) effect on DDR4 SDRAM, using 60 Co γ-rays. Although retention time degraded with 830 Gy(Si) exposure, no retention errors were observed at the retention time of 64-ms and temperature of 80 °C. Unlike retention time degradation, the significant degradation in one-row hammering threshold was observed. The threshold was reduced by up to 113 k with tRP 53.75 ns-67% reduction from pre-irradiation values.
- 1 January 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 80, 85-90
Study of proton radiation effect to row hammer fault in DDR4 SDRAMs
- 1 January 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 80, 85-90
Study of proton radiation effect to row hammer fault in DDR4 SDRAMs
- 1 December 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 67, 143-149
Statistical distributions of row-hammering induced failures in DDR3 components
- 1 December 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 67, 143-149
Statistical distributions of row-hammering induced failures in DDR3 components
- 1 February 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 57, 39-46
Experiments and root cause analysis for active-precharge hammering fault in DDR3 SDRAM under 3 × nm technology
- 1 February 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 57, 39-46
Experiments and root cause analysis for active-precharge hammering fault in DDR3 SDRAM under 3 × nm technology