Payam Zandiyeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Payam Zandiyeh has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Alonso Figueroa
Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Houston, Texas, USA
3 shared publications- James M. Gregory
Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Houston, Texas, USA
3 shared publications - Jason Konrath
Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Houston, Texas, USA
3 shared publications - Tomasz Bugajski
Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Houston, Texas, USA
3 shared publications - Alonso Figueroa
Department of Orthopedic Surgery, University of Texas Health Science Center at Houston, Houston, Texas, USA
2 shared publications - Braden C. Fleming
Department of Orthopaedics, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, Rhode Island, USA
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (10)
Dynamic Acromiohumeral Bone Surface Proximity and Scapuloclavicular Kinematics in Nonoperatively Managed Acromioclavicular Joint Injuries
Background: Abnormal scapular biomechanics after acromioclavicular joint (ACJ) disruption may increase susceptibility to secondary pathologies such as subacromial impingement and rotator cuff degeneration. Traditionally, nonoperative management is suggested for low-grade disruptions (Rockwood types ≤3). However, the effects of ACJ disruption on dynamic scapular mechanics and acromiohumeral bone surface proximity in patients managed nonoperatively remain unexplored. Purpose: To quantify in vivo scapuloclavicular and glenohumeral kinematics, as well as acromiohumeral bone surface proximity, during dynamic humeral elevation in patients with nonoperatively managed ACJ injuries, using subject-specific bone models and biplanar video-radiography (BVR). Study Design: Cross-sectional study; Level of evidence, 3. Methods: Ten participants (9 male, 1 female; mean age, 42 ± 10 years) with previous ACJ disruption classified as Rockwood type III-V were enrolled 1 to 3 years after injury. Participants underwent 3-dimensional (3D) computed tomography and BVR during abduction, scaption, and flexion. Patient-specific bone models were registered to the BVR data to quantify scapular, clavicular, and humeral kinematics. Regions of interest (ROIs) were defined on the scapular and humeral surface models to represent the supraspinatus footprint and inferior acromial surface. The minimum 3D Euclidean distance between ROIs and their anatomical locations was calculated for each movement. Results: The injured limb demonstrated greater scapular upward rotation and internal rotation relative to the clavicle during scaption and flexion. During forward flexion, the minimum bone surface proximity between the supraspinatus footprint and the inferior acromion also occurred at a more anterior location. Additionally, the injured limb reached minimum proximity earlier at lower elevation angles compared with the contralateral limb. Conclusion: Patients with nonoperatively managed ACJ disruption exhibit an anterior shift in acromiohumeral proximity during flexion, accompanied by increased scapular internal rotation. These findings suggest that subtle alterations in dynamic scapuloclavicular coordination may alter which regions of the coracoacromial arch are encountered by the supraspinatus tendon, potentially influencing localized mechanical loading and impingement mechanisms. Improved understanding of dynamic scapuloclavicular coupling may help refine rehabilitation strategies and inform treatment stratification.
- 19 October 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (10)
Open AccessDynamic Acromiohumeral Bone Surface Proximity and Scapuloclavicular Kinematics in Nonoperatively Managed Acromioclavicular Joint Injuries
Background: Abnormal scapular biomechanics after acromioclavicular joint (ACJ) disruption may increase susceptibility to secondary pathologies such as subacromial impingement and rotator cuff degeneration. Traditionally, nonoperative management is suggested for low-grade disruptions (Rockwood types ≤3). However, the effects of ACJ disruption on dynamic scapular mechanics and acromiohumeral bone surface proximity in patients managed nonoperatively remain unexplored. Purpose: To quantify in vivo scapuloclavicular and glenohumeral kinematics, as well as acromiohumeral bone surface proximity, during dynamic humeral elevation in patients with nonoperatively managed ACJ injuries, using subject-specific bone models and biplanar video-radiography (BVR). Study Design: Cross-sectional study; Level of evidence, 3. Methods: Ten participants (9 male, 1 female; mean age, 42 ± 10 years) with previous ACJ disruption classified as Rockwood type III-V were enrolled 1 to 3 years after injury. Participants underwent 3-dimensional (3D) computed tomography and BVR during abduction, scaption, and flexion. Patient-specific bone models were registered to the BVR data to quantify scapular, clavicular, and humeral kinematics. Regions of interest (ROIs) were defined on the scapular and humeral surface models to represent the supraspinatus footprint and inferior acromial surface. The minimum 3D Euclidean distance between ROIs and their anatomical locations was calculated for each movement. Results: The injured limb demonstrated greater scapular upward rotation and internal rotation relative to the clavicle during scaption and flexion. During forward flexion, the minimum bone surface proximity between the supraspinatus footprint and the inferior acromion also occurred at a more anterior location. Additionally, the injured limb reached minimum proximity earlier at lower elevation angles compared with the contralateral limb. Conclusion: Patients with nonoperatively managed ACJ disruption exhibit an anterior shift in acromiohumeral proximity during flexion, accompanied by increased scapular internal rotation. These findings suggest that subtle alterations in dynamic scapuloclavicular coordination may alter which regions of the coracoacromial arch are encountered by the supraspinatus tendon, potentially influencing localized mechanical loading and impingement mechanisms. Improved understanding of dynamic scapuloclavicular coupling may help refine rehabilitation strategies and inform treatment stratification.
- 14 October 2026
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
The Effect of Ambient Light on Gait Variability and Joint Biomechanics in Individuals with Unilateral Transfemoral Amputation
Background: Visual input is crucial for stable gait, particularly in individuals with transfemoral amputation (TFA) who lack somatosensory feedback from their TFA limb. Low-light conditions may further influence their walking patterns, increasing the risk of falls and joint disorders. Objective: This study examined the effect of ambient lighting on between-limb asymmetry during treadmill gait in individuals with TFA by assessing gait variability and joint biomechanics under regular and low-light conditions. Study Design: Observational study methods: Ten participants with unilateral TFA (six males, age = 36.9 ± 10.4 years, K level ≥ 3) walked at a self-selected speed on a split-belt treadmill under both lighting conditions. Outcomes measures included variability in spatiotemporal variables and sagittal trunk motion, as well as sagittal and frontal plane joint kinetics and kinematics. Two-way repeated-measure analysis of variance was conducted to examine limb asymmetries and limb × light interaction. Bonferroni-corrected post hoc analyses were performed when interaction effects were significant (α = 0.05). Results: Significant between-limb asymmetries were observed in step width variability and sagittal and frontal plane joint biomechanics across both lighting conditions. Under low-light conditions, these asymmetries were reflected by increasing the intact limb step width variability and peak internal hip extension moment, but a decrease in trunk flexion angular velocity variability. Conclusion: These results provide initial evidence that ambient lighting influences gait stability and joint loading in individuals with TFA. Our findings highlight that individuals with TFA are vulnerable to environmental challenges and the importance of considering lighting in designing interventions and fall-prevention strategies. Clinical Relevance: Clinically, attention to environmental lighting may be important when assessing gait, prescribing rehabilitation strategies, and designing fall-prevention interventions for this population. ( J Prosthet Orthot . 2026;X:XX–XX).
- 14 October 2026
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
The Effect of Ambient Light on Gait Variability and Joint Biomechanics in Individuals with Unilateral Transfemoral Amputation
Background: Visual input is crucial for stable gait, particularly in individuals with transfemoral amputation (TFA) who lack somatosensory feedback from their TFA limb. Low-light conditions may further influence their walking patterns, increasing the risk of falls and joint disorders. Objective: This study examined the effect of ambient lighting on between-limb asymmetry during treadmill gait in individuals with TFA by assessing gait variability and joint biomechanics under regular and low-light conditions. Study Design: Observational study methods: Ten participants with unilateral TFA (six males, age = 36.9 ± 10.4 years, K level ≥ 3) walked at a self-selected speed on a split-belt treadmill under both lighting conditions. Outcomes measures included variability in spatiotemporal variables and sagittal trunk motion, as well as sagittal and frontal plane joint kinetics and kinematics. Two-way repeated-measure analysis of variance was conducted to examine limb asymmetries and limb × light interaction. Bonferroni-corrected post hoc analyses were performed when interaction effects were significant (α = 0.05). Results: Significant between-limb asymmetries were observed in step width variability and sagittal and frontal plane joint biomechanics across both lighting conditions. Under low-light conditions, these asymmetries were reflected by increasing the intact limb step width variability and peak internal hip extension moment, but a decrease in trunk flexion angular velocity variability. Conclusion: These results provide initial evidence that ambient lighting influences gait stability and joint loading in individuals with TFA. Our findings highlight that individuals with TFA are vulnerable to environmental challenges and the importance of considering lighting in designing interventions and fall-prevention strategies. Clinical Relevance: Clinically, attention to environmental lighting may be important when assessing gait, prescribing rehabilitation strategies, and designing fall-prevention interventions for this population. ( J Prosthet Orthot . 2026;X:XX–XX).
- Open Access
- 9 October 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (10)
In Vivo Validation of Automated Knee Arthrometry: What Do These Measurements Really Represent?
Background: Objective assessment of anterior knee laxity (AKL) is important for evaluating graft integrity after anterior cruciate ligament (ACL) reconstruction. Automated arthrometers, such as the GNRB, provide reproducible measurements; however, the in vivo biomechanical meaning and validity of these measurements remain unclear. Hypothesis/Purpose: The primary purpose was to validate GNRB-derived AKL measurements against biplanar videoradiography (BVR)–derived metrics under in vivo postoperative conditions. It was hypothesized that GNRB measurements would differ significantly from BVR-derived measures of tibiofemoral translation and ACL graft elongation. A secondary, exploratory purpose was to examine the relationships between GNRB- and BVR-derived laxity measures. Study Design: Cohort study (Diagnosis); Level of evidence, 2. Methods: Twenty patients (6 months post-ACL reconstruction) underwent simultaneous AKL testing using a GNRB arthrometer and BVR. Six BVR-derived laxity metrics were calculated, including tibiofemoral translation, tibial tuberosity displacement, and ACL graft elongation. Arthrometer accuracy was assessed using a repeated-measures analysis of covariance, and linear regression analyses were used to evaluate relationships between GNRB- and BVR-derived measures. Results: GNRB-derived laxity differed significantly from all BVR-derived measures ( P < .001). Compared with BVR-defined tibiofemoral and graft-based metrics, the GNRB consistently overestimated AKL (bias: 3.4-6.1 mm). The strongest relationship to GNRB was observed in BVR-derived tibial tuberosity displacement expressed in the world coordinate system ( r = 0.93), whereas associations with ACL graft elongation were weakest ( r = 0.51-0.66). Differences between tibial tuberosity displacement expressed relative to the femur versus the world coordinate system indicated a substantial contribution of femoral motion during arthrometric testing. Conclusion: This study provides the first in vivo validation of GNRB-derived AKL measurements following ACL reconstruction. Using BVR as the reference standard, the GNRB consistently overestimated AKL and showed the weakest correlation with ACL graft elongation. These findings highlight the need to better understand how arthrometry relates to knee motion and ACL graft elongation to improve the reliability and clinical interpretation of postoperative AKL assessments.
- 9 October 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (10)
Open AccessIn Vivo Validation of Automated Knee Arthrometry: What Do These Measurements Really Represent?
Background: Objective assessment of anterior knee laxity (AKL) is important for evaluating graft integrity after anterior cruciate ligament (ACL) reconstruction. Automated arthrometers, such as the GNRB, provide reproducible measurements; however, the in vivo biomechanical meaning and validity of these measurements remain unclear. Hypothesis/Purpose: The primary purpose was to validate GNRB-derived AKL measurements against biplanar videoradiography (BVR)–derived metrics under in vivo postoperative conditions. It was hypothesized that GNRB measurements would differ significantly from BVR-derived measures of tibiofemoral translation and ACL graft elongation. A secondary, exploratory purpose was to examine the relationships between GNRB- and BVR-derived laxity measures. Study Design: Cohort study (Diagnosis); Level of evidence, 2. Methods: Twenty patients (6 months post-ACL reconstruction) underwent simultaneous AKL testing using a GNRB arthrometer and BVR. Six BVR-derived laxity metrics were calculated, including tibiofemoral translation, tibial tuberosity displacement, and ACL graft elongation. Arthrometer accuracy was assessed using a repeated-measures analysis of covariance, and linear regression analyses were used to evaluate relationships between GNRB- and BVR-derived measures. Results: GNRB-derived laxity differed significantly from all BVR-derived measures ( P < .001). Compared with BVR-defined tibiofemoral and graft-based metrics, the GNRB consistently overestimated AKL (bias: 3.4-6.1 mm). The strongest relationship to GNRB was observed in BVR-derived tibial tuberosity displacement expressed in the world coordinate system ( r = 0.93), whereas associations with ACL graft elongation were weakest ( r = 0.51-0.66). Differences between tibial tuberosity displacement expressed relative to the femur versus the world coordinate system indicated a substantial contribution of femoral motion during arthrometric testing. Conclusion: This study provides the first in vivo validation of GNRB-derived AKL measurements following ACL reconstruction. Using BVR as the reference standard, the GNRB consistently overestimated AKL and showed the weakest correlation with ACL graft elongation. These findings highlight the need to better understand how arthrometry relates to knee motion and ACL graft elongation to improve the reliability and clinical interpretation of postoperative AKL assessments.
- 11 August 2026
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
Kinetic asymmetry in unilateral transfemoral amputees: Gait biomechanics and reliability assessments
Background: Individuals with unilateral transfemoral amputation (TFA) commonly experience gait-related loading asymmetries, elevating their risks of lower limb injuries and degenerative changes. To evaluate the effects of interventions on these asymmetries, it is crucial to assess test-retest reliability and establish minimum detectable changes (MDCs) for loading-related measures. Determining them for these measures would help distinguish meaningful interventional effects from daily variability. This study evaluated test-retest reliability and established MDC values for ground reaction force (GRF) during treadmill walking in individuals with TFA and compared GRF outcomes between the amputated and intact limbs. Methods: Ten participants underwent 2 study visits, 1 month apart. Ground reaction force data were collected during treadmill walking at a self-selected speed. Outcome measures included loading rates, unloading rates, braking impulses, and propulsive impulses, normalized by body weight. Intersession reliability and MDC values were computed with intraclass correlation analysis. Side-to-side differences were analyzed using repeated-measures ANOVAs. Ground reaction force time series were compared using statistical parametric mapping (SPM-1d). Results: Braking and propulsion impulses demonstrated good-to-excellent reliability (intraclass correlation coefficients >0.82) in both limbs, whereas intact limb loading rates showed poor reliability. Higher loading rate but lower propulsion impulses were detected in the amputated limb, with differences in propulsion impulses exceeding MDC values. SPM-1d analyses detected side-to-side differences in GRF waveforms at the beginning and the end of the stance phase in superior-inferior and anterior-posterior directions. Conclusion: Impulse outcomes are reliable measures, promising for future investigation of treatment effectiveness in longitudinal gait studies in individuals with TFA.
- 11 August 2026
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
Kinetic asymmetry in unilateral transfemoral amputees: Gait biomechanics and reliability assessments
Background: Individuals with unilateral transfemoral amputation (TFA) commonly experience gait-related loading asymmetries, elevating their risks of lower limb injuries and degenerative changes. To evaluate the effects of interventions on these asymmetries, it is crucial to assess test-retest reliability and establish minimum detectable changes (MDCs) for loading-related measures. Determining them for these measures would help distinguish meaningful interventional effects from daily variability. This study evaluated test-retest reliability and established MDC values for ground reaction force (GRF) during treadmill walking in individuals with TFA and compared GRF outcomes between the amputated and intact limbs. Methods: Ten participants underwent 2 study visits, 1 month apart. Ground reaction force data were collected during treadmill walking at a self-selected speed. Outcome measures included loading rates, unloading rates, braking impulses, and propulsive impulses, normalized by body weight. Intersession reliability and MDC values were computed with intraclass correlation analysis. Side-to-side differences were analyzed using repeated-measures ANOVAs. Ground reaction force time series were compared using statistical parametric mapping (SPM-1d). Results: Braking and propulsion impulses demonstrated good-to-excellent reliability (intraclass correlation coefficients >0.82) in both limbs, whereas intact limb loading rates showed poor reliability. Higher loading rate but lower propulsion impulses were detected in the amputated limb, with differences in propulsion impulses exceeding MDC values. SPM-1d analyses detected side-to-side differences in GRF waveforms at the beginning and the end of the stance phase in superior-inferior and anterior-posterior directions. Conclusion: Impulse outcomes are reliable measures, promising for future investigation of treatment effectiveness in longitudinal gait studies in individuals with TFA.
- Open Access
- 22 May 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (6) , 065007
Using a monoplane stereoscopic videoradiography configuration to accurately measure skeletal positions: a proof-of-concept study
Biplanar videoradiography is a validated method for measuring skeletal kinematics. However, using two X-ray source-detector pairs introduces geometric constraints that can compromise image quality. The spatial configuration of the two pairs often requires a larger object-to-image distance (OID). This setup leads to greater image magnification and reduced signal intensity at the detector, increasing the risk of underexposure. Consequently, visualization of deeper anatomical structures, such as the lumbar spine, can become challenging, and the effective field of view may be limited, restricting multi-joint analyses. To address this limitation, this proof-of-concept study evaluated a monoplane stereoscopic videoradiography (MSV) configuration. MSV uses two X-ray sources captured by a single detector, enabling a smaller OID. A pseudo-dynamic experiment was conducted to assess whether MSV would achieve accurate calibration and subsequent 3D bone positions. A cube and pelvis phantom were rotated 360° on a turntable in 15° increments. At each increment, positions were recorded using both conventional motion capture (MOCAP) and MSV, with MOCAP acting as the reference standard. During MSV image acquisition, a lead barrier alternately blocked one X-ray source, allowing the other to project onto the detector. Calibration was performed using a bundle adjustment technique, and 3D bone positions were calculated using radiostereometric analysis and model-based tracking and compared against MOCAP. Overall, MSV achieved sub-millimeter and sub-degree accuracy. The calibration yielded a mean residual of 0.22 mm, while rotational and translational biases ranged from 0.36-1.16° and 0.22-1.23 mm, respectively, with precisions of 0.09-0.59° and 0.18-0.58 mm. These results support the feasibility of using MSV to accurately calculate skeletal positions. This approach reduces magnification and inherently increases detector exposure, opening avenues for multi-joint analyses and improved imaging of deeper joints. Future work will focus on implementing a true asynchronous MSV acquisition to extend this approach to dynamic, in vivo kinematic studies.
- 22 May 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (6) , 065007
Open AccessUsing a monoplane stereoscopic videoradiography configuration to accurately measure skeletal positions: a proof-of-concept study
Biplanar videoradiography is a validated method for measuring skeletal kinematics. However, using two X-ray source-detector pairs introduces geometric constraints that can compromise image quality. The spatial configuration of the two pairs often requires a larger object-to-image distance (OID). This setup leads to greater image magnification and reduced signal intensity at the detector, increasing the risk of underexposure. Consequently, visualization of deeper anatomical structures, such as the lumbar spine, can become challenging, and the effective field of view may be limited, restricting multi-joint analyses. To address this limitation, this proof-of-concept study evaluated a monoplane stereoscopic videoradiography (MSV) configuration. MSV uses two X-ray sources captured by a single detector, enabling a smaller OID. A pseudo-dynamic experiment was conducted to assess whether MSV would achieve accurate calibration and subsequent 3D bone positions. A cube and pelvis phantom were rotated 360° on a turntable in 15° increments. At each increment, positions were recorded using both conventional motion capture (MOCAP) and MSV, with MOCAP acting as the reference standard. During MSV image acquisition, a lead barrier alternately blocked one X-ray source, allowing the other to project onto the detector. Calibration was performed using a bundle adjustment technique, and 3D bone positions were calculated using radiostereometric analysis and model-based tracking and compared against MOCAP. Overall, MSV achieved sub-millimeter and sub-degree accuracy. The calibration yielded a mean residual of 0.22 mm, while rotational and translational biases ranged from 0.36-1.16° and 0.22-1.23 mm, respectively, with precisions of 0.09-0.59° and 0.18-0.58 mm. These results support the feasibility of using MSV to accurately calculate skeletal positions. This approach reduces magnification and inherently increases detector exposure, opening avenues for multi-joint analyses and improved imaging of deeper joints. Future work will focus on implementing a true asynchronous MSV acquisition to extend this approach to dynamic, in vivo kinematic studies.
- 18 April 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 203, 113318
In vivo assessment of the subacromial space during shoulder elevation following acromioclavicular joint reconstruction
- 18 April 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 203, 113318
In vivo assessment of the subacromial space during shoulder elevation following acromioclavicular joint reconstruction
- Open Access
- 24 February 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (2)
Preliminary In Vivo Evaluation of Coracoclavicular Ligament Mechanics During Shoulder Elevation After Acromioclavicular Joint Reconstruction
Background: Persistent instability and altered scapular mechanics after acromioclavicular joint (ACJ) reconstruction may stem from inadequate replication of native coracoclavicular (CC) ligament function. However, in vivo data on postoperative CC ligament behavior during dynamic shoulder motion remain lacking. Purpose: To assess in vivo functional distance and timing characteristics of the conoid and trapezoid ligaments during active shoulder elevation after ACJ reconstruction, using dynamic stereo x-ray (DSX) imaging and patient-specific 3-dimensional (3D) models. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twelve participants (10 men and 2 women, mean age 39 ± 10 years, mean body mass 92 ± 17 kg) who had sustained an acute unilateral ACJ disruption (Rockwood classification of 3-5) and undergone anatomic ACJ reconstruction were recruited within 1 to 3 years after surgery. Participants underwent 3D computed tomography (CT) and DSX imaging to capture abduction, scaption, and flexion movements. Patient-specific bone models with digitized CC insertion points were then aligned within each frame of the biplanar radiograph images. From this, the peak functional distance, time at peak, and displacement were measured and compared with the uninjured limb. Results: Compared with uninjured limbs, the reconstructed limb demonstrated increased conoid and trapezoid peak distances of 23% and 17% between insertion points, respectively, across abduction, flexion, and scaption. Additionally, the conoid and trapezoid reached these peak distances at later stages of the movement cycle, and experienced increased displacement by 2.7 and 1.8 mm, respectively, in the reconstructed limb. Conclusion: This investigation established the methodological feasibility of using DSX combined with patient-specific CT models to quantify in vivo ligament behavior during functional shoulder motion. It further identified significant asymmetries in the functional distance between conoid and trapezoid ligament insertion points when comparing reconstructed and uninjured limbs across multiple shoulder elevation movements.
- 24 February 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (2)
Open AccessPreliminary In Vivo Evaluation of Coracoclavicular Ligament Mechanics During Shoulder Elevation After Acromioclavicular Joint Reconstruction
Background: Persistent instability and altered scapular mechanics after acromioclavicular joint (ACJ) reconstruction may stem from inadequate replication of native coracoclavicular (CC) ligament function. However, in vivo data on postoperative CC ligament behavior during dynamic shoulder motion remain lacking. Purpose: To assess in vivo functional distance and timing characteristics of the conoid and trapezoid ligaments during active shoulder elevation after ACJ reconstruction, using dynamic stereo x-ray (DSX) imaging and patient-specific 3-dimensional (3D) models. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twelve participants (10 men and 2 women, mean age 39 ± 10 years, mean body mass 92 ± 17 kg) who had sustained an acute unilateral ACJ disruption (Rockwood classification of 3-5) and undergone anatomic ACJ reconstruction were recruited within 1 to 3 years after surgery. Participants underwent 3D computed tomography (CT) and DSX imaging to capture abduction, scaption, and flexion movements. Patient-specific bone models with digitized CC insertion points were then aligned within each frame of the biplanar radiograph images. From this, the peak functional distance, time at peak, and displacement were measured and compared with the uninjured limb. Results: Compared with uninjured limbs, the reconstructed limb demonstrated increased conoid and trapezoid peak distances of 23% and 17% between insertion points, respectively, across abduction, flexion, and scaption. Additionally, the conoid and trapezoid reached these peak distances at later stages of the movement cycle, and experienced increased displacement by 2.7 and 1.8 mm, respectively, in the reconstructed limb. Conclusion: This investigation established the methodological feasibility of using DSX combined with patient-specific CT models to quantify in vivo ligament behavior during functional shoulder motion. It further identified significant asymmetries in the functional distance between conoid and trapezoid ligament insertion points when comparing reconstructed and uninjured limbs across multiple shoulder elevation movements.
- 15 October 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 193, 113013
The reliability and minimal detectable change in gait outcomes among individuals with unilateral transfemoral amputation: A generalizability theory approach
- 15 October 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 193, 113013
The reliability and minimal detectable change in gait outcomes among individuals with unilateral transfemoral amputation: A generalizability theory approach
- Open Access
- 19 September 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (12) , 2841-2850
Relationship Between Quantitative MRI UTE T2* of ACL Autografts and BMI-Normalized Knee Laxity Within the First Year After ACL Reconstruction
Background: The anterior cruciate ligament reconstruction (ACLR) graft undergoes a remodeling process that affects its structural properties. Ultrashort echo time T 2* (UTE-T 2* ) imaging has been instrumental in examining this process. However, more research is needed on the postoperative relationship between UTE-T 2* of the graft and its mechanical properties. Purpose: To longitudinally examine ACL graft changes after ACLR using UTE-T 2* decay coefficients and knee laxity and explore their relationship. Study Design: Case series; Level of evidence, 4. Methods: A total of 31 patients who underwent ACLR had magnetic resonance imaging of their knees at 1, 6, and 12 months after surgery using a UTE-T 2* sequence. Bilateral knee laxity was measured at 6 and 12 months using a GNRB arthrometer (force = 200 N). UTE-T 2* coefficients of the graft were calculated using mono- (T 2m* ) and biexponential (short [T 2s* ] and long [T 2l* ]) analyses, and outcomes were normalized to body mass index. Linear mixed models were used to determine longitudinal changes in UTE-T 2* and laxity; the Pearson correlation was used to explore the correlations between these outcomes. Results: T 2m* of the graft increased from 1 to 6 months (Δ = 0.092; P = .008), followed by a decrease from 6 to 12 months (Δ = −0.079; P = .021). Regardless of the limb side, a decrease in laxity was detected between 6 and 12 months after surgery (Δ = −0.033; P = .046). Positive correlations between laxity and UTE-T 2* were detected at 6 months (T 2s* : R = 0.285; P = .025) and 12 months (T 2m* : R = 0.532; P < .01; T 2s* : R = 0.669; P < .001; T 2l* : R = 0.354; P = .034). Conclusion: Biexponential analysis of UTE-T 2* MRI provides a sensitive tool for detecting structural changes in the graft after ACL reconstruction, reflecting the dynamic process of graft remodeling. Among the decay coefficients assessed, T 2s* demonstrates a stronger correlation with postoperative laxity, highlighting its potential as a critical biomarker for monitoring graft integrity over time.
- 19 September 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (12) , 2841-2850
Open AccessRelationship Between Quantitative MRI UTE T2* of ACL Autografts and BMI-Normalized Knee Laxity Within the First Year After ACL Reconstruction
Background: The anterior cruciate ligament reconstruction (ACLR) graft undergoes a remodeling process that affects its structural properties. Ultrashort echo time T 2* (UTE-T 2* ) imaging has been instrumental in examining this process. However, more research is needed on the postoperative relationship between UTE-T 2* of the graft and its mechanical properties. Purpose: To longitudinally examine ACL graft changes after ACLR using UTE-T 2* decay coefficients and knee laxity and explore their relationship. Study Design: Case series; Level of evidence, 4. Methods: A total of 31 patients who underwent ACLR had magnetic resonance imaging of their knees at 1, 6, and 12 months after surgery using a UTE-T 2* sequence. Bilateral knee laxity was measured at 6 and 12 months using a GNRB arthrometer (force = 200 N). UTE-T 2* coefficients of the graft were calculated using mono- (T 2m* ) and biexponential (short [T 2s* ] and long [T 2l* ]) analyses, and outcomes were normalized to body mass index. Linear mixed models were used to determine longitudinal changes in UTE-T 2* and laxity; the Pearson correlation was used to explore the correlations between these outcomes. Results: T 2m* of the graft increased from 1 to 6 months (Δ = 0.092; P = .008), followed by a decrease from 6 to 12 months (Δ = −0.079; P = .021). Regardless of the limb side, a decrease in laxity was detected between 6 and 12 months after surgery (Δ = −0.033; P = .046). Positive correlations between laxity and UTE-T 2* were detected at 6 months (T 2s* : R = 0.285; P = .025) and 12 months (T 2m* : R = 0.532; P < .01; T 2s* : R = 0.669; P < .001; T 2l* : R = 0.354; P = .034). Conclusion: Biexponential analysis of UTE-T 2* MRI provides a sensitive tool for detecting structural changes in the graft after ACL reconstruction, reflecting the dynamic process of graft remodeling. Among the decay coefficients assessed, T 2s* demonstrates a stronger correlation with postoperative laxity, highlighting its potential as a critical biomarker for monitoring graft integrity over time.
- 8 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 492-498
Walking does not Diminish Localizability of Vibrotactile Feedback on the Waist
Individuals who lack tactile and/or proprioceptive sensations in their lower limbs commonly report postural and locomotive imbalance. To mitigate imbalance, haptic feedback has been implemented using devices that employ external sensors and waist-worn actuators for sensory augmentation. Analyses of the effectiveness of these devices have primarily focused on balance outcomes and generally disregard the potential effect of the user's varying activities or anthropometric data on their perception of the haptic feedback. Since motor activity can influence haptic perception, we investigate vibrotactile cue localizability in a waist-worn haptic device for two conditions, standing and walking on a treadmill at a self-selected speed. In this preliminary study, ten participants without sensorimotor deficits wore a waistband equipped with seven vibrotactile actuators. Vibrotactile cues were played at randomized locations during standing and walking, and participants reported the perceived stimulation location. In addition, we recorded relevant anthropometric data for each participant. In both standing and walking conditions, participants correctly localized 51% of the vibrotactile cues on average. When considering zonal accuracy, or localization within one vibrotactor position, participants, on average, achieved an accuracy of 91 % in standing and 90% in walking.
- 8 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 492-498
Walking does not Diminish Localizability of Vibrotactile Feedback on the Waist
Individuals who lack tactile and/or proprioceptive sensations in their lower limbs commonly report postural and locomotive imbalance. To mitigate imbalance, haptic feedback has been implemented using devices that employ external sensors and waist-worn actuators for sensory augmentation. Analyses of the effectiveness of these devices have primarily focused on balance outcomes and generally disregard the potential effect of the user's varying activities or anthropometric data on their perception of the haptic feedback. Since motor activity can influence haptic perception, we investigate vibrotactile cue localizability in a waist-worn haptic device for two conditions, standing and walking on a treadmill at a self-selected speed. In this preliminary study, ten participants without sensorimotor deficits wore a waistband equipped with seven vibrotactile actuators. Vibrotactile cues were played at randomized locations during standing and walking, and participants reported the perceived stimulation location. In addition, we recorded relevant anthropometric data for each participant. In both standing and walking conditions, participants correctly localized 51% of the vibrotactile cues on average. When considering zonal accuracy, or localization within one vibrotactor position, participants, on average, achieved an accuracy of 91 % in standing and 90% in walking.