KCKonstantinos Chochlidakis

Konstantinos Chochlidakis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Konstantinos Chochlidakis has a total of 115 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Zirconia full‐arch implant‐supported prostheses: An up to 8‐year retrospective study with 140 jaws from private practice

    by Panos Papaspyridakos, Avinash S Bidra, Armand Bedrossian, Sindhu Kanikicharla, Abdul Basir Barmak, Panagiotis Ntovas, Lawrence Brecht, Marisa Notturno, Konstantinos Chochlidakis

    Purpose: To assess the survival and complication rates of 140 monolithic zirconia implant‐supported full‐arch fixed complete dental prostheses (IFCDPs) with an up to 8‐year follow‐up at a private practice setting. Materials and Methods: A total of 140 edentulous jaws underwent complete‐arch fixed implant treatment with a digital workflow and were rehabilitated with monolithic zirconia IFCDPs. The primary outcome was to assess survival and complication rates, whereas the secondary outcome was to measure the cross‐sectional surface area (CSSA) dimensions (prosthetic space) of those 140 monolithic zirconia IFCDPs and to correlate potential technical complications with the prosthetic space dimensions. Results: Out of the 140 zirconia IFCDPs, six fractured, yielding a 95.7% survival rate up to 8‐year follow‐up. Out of these, three fractures were located in the maxilla and three in the mandible. Non‐fractured maxillary IFCDPs had a mean CSSA of 80.5 mm 2 , whereas fractured ones measured 62.5 mm 2 . The connector CSSA of the non‐fractured maxillary IFCDPs was 17.9 mm 2 greater and was statistically significant ( p < 0.001). Non‐fractured mandibular IFCDPs averaged 79.4 mm 2 , whereas fractured ones measured 54 mm 2 . The connector CSSA of the non‐fractured mandibular IFCDPs was 25.4 mm 2 greater, and the difference was statistically significant ( p < 0.001). Non‐fractured maxillary IFCDPs had a mean posterior linear height measurement (prosthetic space) of 10.58 mm, whereas fractured ones measured 9 mm. The 1.58 mm difference was statistically significant ( p = 0.018). Non‐fractured mandibular IFCDPs had a mean posterior prosthetic space of 11.89 mm, compared to 9.55 mm in fractured ones. The 2.34 mm difference was statistically significant ( p < 0.001). Conclusion: Monolithic zirconia IFCDPs yielded a 95.7% survival rate after a mean observation period of 3 years (range of 1–8 years). Within the limitations of this study, the maxillary and mandibular connector CSSA should be at least 80 mm 2 , and the linear measurements should be more than 10 mm during CAD design of the final prosthesis to ensure zirconia prosthesis strength against fracture.

  • Open Access

    Implementing digital technology when restoring full-arch implant prostheses: what, when & how

    by E. Armand Bedrossian, Panos Papaspyridakos, Konstantinos Chochlidakis

  • Comparison of crestal bone levels, peri‐implant indices, mucosal margin position, and pink esthetic score of posterior implant crowns fabricated with immediate vs delayed impressions: A 5‐year retrospective cross‐ sectional study

    by Sindhu Kanikicharla, Tim Chae, Elli Anna Kotsailidi, Konstantinos Chochlidakis, Changyong Feng, Carlo Ercoli

    Purpose: This 5‐year cross‐sectional study aimed to determine whether immediate and delayed impression workflows result in differences in crestal bone levels (CBLs), peri‐implant indices, mucosal margin position, and pink esthetic score (PES). Materials and Methods: Patients who had received a single posterior implant crown in the premolar and molar regions for ≥5 years were identified. Outcome measurements for peri‐implant indices, including modified plaque index (mPI), modified sulcus bleeding index (mSBI), presence or absence of bleeding on probing (BoP), and probing pocket depths (PPDs), were measured at six sites per implant. The peri‐implant mucosal margin position was measured relative to an adjacent or contralateral tooth. CBLs were assessed radiographically using standardized vertical bitewing radiographs with the paralleling technique. PES was calculated with a total possible score of 14. The Shapiro–Wilk test was employed to assess the normality of the data distribution. For variables following a normal distribution, a two‐sample t ‐test was used to compare the mean values between the two groups. Conversely, for non‐normally distributed data, the Mann–Whitney U test was utilized to determine whether significant differences existed between the group distributions. The significance level was set at 0.05. Results: Mean mesial CBL for the immediately‐ and delayed‐impressed groups were −0.30 ± 1.01 mm and 0.07 ± 1.18 mm, respectively. Mean distal CBL for the same groups were −0.14 ± 0.56 mm and −0.30 ± 0.79 mm, respectively. Mean mesio‐buccal, mid‐buccal, and disto‐buccal PPDs were 3.18 ± 1.08 mm, 1.36 ± 0.76 mm, and 2.73 ± 1.10 mm for the immediate impression group and 3.14 ± 1.35 mm, 1.93 ± 1.14 mm, and 3.07 ± 1.07 mm for the delayed impression group. Mean mesio‐lingual, mid‐lingual, and disto‐lingual PPDs were 2.55 ± 0.69 mm, 1.45 ± 0.69 mm, and 3.09 ± 0.94 mm for the immediate impression group and 3.29 ± 0.83 mm, 2 ± 1.24 mm, and 3.50 ± 1.45 mm for the delayed impression group. Mean PES was 12.64 ± 1.03 and 12 ± 2 for the immediately‐ and delayed‐impressed groups. There were no statistically significant differences between immediate and delayed impression groups for PES, peri‐implant indices, mucosal marginal position, or CBLs. Conclusion: At 5 years, there was no significant difference in PES, CBL, peri‐implant indices, or mucosal margin position between implants restored with immediate impressions and those restored with delayed impressions made after osseointegration and soft tissue healing.

  • Reverse scan body: A retrospective clinical study with 30 edentulous jaws

    by Panos Papaspyridakos, E. Armand Bedrossian, Sindhu Kanikicharla, Panagiotis Ntovas, Abdul Basir Barmak, Konstantinos Chochlidakis

    Purpose: To evaluate the accuracy of fit of full‐arch zirconia prostheses fabricated using a fully digital workflow with extraoral scanning with the reverse scan body protocol. Materials and Methods: This retrospective study included 30 patients treated with zirconia full‐arch implant‐supported fixed complete dental prostheses (IFCDPs). Out of these 30 patients, 15 patients received IFCDPs supported by four implants, and the other 15 received IFCDPs supported by six implants. Each patient underwent full‐arch implant rehabilitation with digital workflow using the reverse scan body protocol. Digitally designed verification jigs and prototypes were milled and used to confirm the accuracy of the scan, esthetics, and phonetics for each patient. Following the verification jig, monolithic zirconia IFCDPs were milled, assessed for fit, and delivered. Fit accuracy was evaluated through screw resistance test, visual examination, and radiographs. Results: All 30 milled prostheses (100%) achieved an accurate fit under clinical and radiographic assessment. Conclusion: Full‐arch zirconia prostheses with an accurate fit can be fabricated using extraoral scanning with the reverse scan body protocol.


  • Biologic complications with removable partial dentures assisted by short implants: A 34-month pilot randomized controlled clinical trial

    by Shalom I. Benzaquen, Mahshid Torabi Ardakani, Alexandra Tsigarida, Carlo Ercoli, Basir Barmak, Konstantinos M. Chochlidakis, Elli Anna Kotsailidi


  • Removable partial dentures assisted by short implants: A 34-month randomized controlled clinical trial

    by Mahshid Torabi Ardakani, Shalom I. Benzaquen, Elli Anna Kotsailidi, Alexandra Tsigarida, Carlo Ercoli, Abdul Basir Barmak, Konstantinos Chochlidakis


  • Zirconia full‐arch implant prostheses: Survival, complications, and prosthetic space dimensions with 115 edentulous jaws

    by Panos Papaspyridakos, Naif Sinada, Panagiotis Ntovas, Abdul Basir Barmak, Konstantinos Chochlidakis

    Purpose: To assess the survival and complication rates of 115 monolithic zirconia implant‐supported fixed complete dental prostheses (IFCDPs) with an up to 6‐year follow‐up.Materials and Methods: One hundred fifteen edentulous jaws (71 patients) underwent complete‐arch implant treatment with a digital workflow and were rehabilitated with monolithic zirconia IFCDPs. The primary outcome was to assess survival and complication rates while the secondary outcome was to measure the cross‐sectional dimensions (prosthetic space) of those 115 monolithic zirconia IFCDPs and to correlate potential technical complications with the prosthetic space dimensions.Results: Out of the 115 zirconia IFCDPs, 2 fractured, yielding a 98.6% survival rate up to a 6‐year follow‐up. The most commom minor technical complications were loss of screw access channel filling and porcelain chipping for the modified monolithic IFCDPs. There was no significant association between the count and type of complications and jaw location (maxilla vs. mandible) or prosthesis type (FP1 vs. FP3), according to Fisher's exact test. For maxillary zirconia IFCDPs, the mean square surface for the at the posterior abutment cross‐sectional area was 25.18 mm2 at the lingual side of the abutment and 34.19 mm2 at the buccal side, respectively. The anterior abutment cross‐sectional area was 33.92 mm2 at the lingual side of the abutment and 29.49 mm2 at the buccal side, respectively. For mandibular zirconia IFCDPs, the mean square surface at the posterior abutment cross‐sectional area was 29.89 mm2 at the lingual side of the abutment and 39.05 mm2 at the buccal side, respectively. The anterior abutment cross‐sectional area was 27.07 mm2 at the lingual side of the abutment and 56.50 mm2 at the buccal side, respectively. At the connector cross‐sectional area, the mean square surface for the maxillary zirconia IFCDPs was 64.33 and 90.56 mm2 for the mandibular zirconia IFCDPs. The two fractures occurred in the midline (anterior area) for both maxillary FP1 prosthesis and mandibular FP3 prosthesis. The mean surface area at the connector for the maxillary FP1 prosthesis was 28.50 and 82.11 mm2 for the mandibular FP3 prosthesis, and was within the range of IFCDP connector square surface area. There was no significant association between the thickness of the zirconia prosthesis and the encountered prosthesis fractures.Conclusions: Monolithic zirconia IFCDPs yielded a 98.6% survival rate, after a mean observation period of 62 months with an SE of 3.1. The connector mean surface area in the two fractured IFCDPs was within the square surface range (minimum–maximum) as for the remaining 113 complication‐free IFCDPs.


  • Reverse scan body: Complete digital workflow for double full‐arch zirconia prostheses

    by Panos Papaspyridakos, Lina Castellanos, E. Armand Bedrossian, Davide Romeo, Yukio Kudara, Konstantinos Chochlidakis

    During intraoral complete‐arch digital implant scanning, one of the most technique‐sensitive steps is the implant data acquisition and merging of different surface geometry data sets for prototype prosthesis fabrication due to the absence of fixed landmarks. Recently developed extraoral techniques have allowed for an alternative approach for the digital acquisition of implant position in completely edentulous patients. Specifically, extraoral digital scanning of the conversion prosthesis after connecting reverse scan bodies has been proposed as an efficient approach. The reverse scan body protocol digitally simulates the traditional back‐pouring technique long utilized in analog workflows. The present article describes a technique for simplifying the digital workflow for the fabrication of passive‐fitting definitive prostheses using the reverse scan body concept.


  • Treatment planning algorithm for patients with a terminal dentition

    by Ricardo Mitrani, Panos Papaspyridakos, E. Armand Bedrossian, Jack Goldberg, Alexandra Tsigarida, Konstantinos Chochlidakis