Carl A. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carl A. Anderson has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
James K. Drennen
Graduate School of Pharmaceutical Sciences, Duquesne University, Pittsburgh, USA
44 shared publications- Benoît Igne
Vertex Pharmaceuticals Inc
17 shared publications Zhenqi Shi
SMDD, Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, Indiana 46285
10 shared publicationsRobert P. Cogdill
Lincoln College of Engineering, University of Nebraska, Lincoln, Nebraska 68588-0642
7 shared publicationsShikhar Mohan
Duquesne University, Pittsburgh, PA 15282, United States
7 shared publicationsNayeem Hossain
Duquesne University, Pittsburgh, PA 15282, United States
6 shared publications
Latest Publications
- Open Access
- 22 July 2026
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 702, 127216
Enhancing understanding of the prediction behavior of the iterative optimization technology (IOT) algorithm using model diagnostics
- 22 July 2026
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 702, 127216
Open AccessEnhancing understanding of the prediction behavior of the iterative optimization technology (IOT) algorithm using model diagnostics
- Open Access
- 20 December 2025
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 49 (2) , 385-401
Enhancing analytical sensitivity in upstream bioprocess using time-gated Raman spectroscopy
Upstream bioprocessing is a very complex system and requires rapid responses to process deviations. Mammalian cell culture processes are conventionally monitored for process-related and cell growth-related parameters, including pH, dissolved oxygen, viable cell density, cell viability, and key analyte concentrations that serve as primary indicators of the metabolic state of the cell culture. Raman spectroscopy (RS) has been increasingly applied as a viable inline process analytical technology (PAT) tool for cell culture monitoring and prediction of key analytes and attributes. The primary limitation to RS in these measurements is fluorescence (also referred to as sample-induced fluorescence), which interferes with the Raman signal and creates noise that makes detection of the signal from the analytes difficult. As a result, fluorescence interference decreases the signal to noise ratio (SNR) of the acquired spectra and increases the limit of detection (LOD) of analytical methods. Time-gated Raman spectroscopy (TGRS) takes advantage of the temporal delay between inelastic light scatter (Raman signal) and fluorescence emission to reduce interference from fluorescence. In this study, a pure component modeling approach and Net Analyte Signal (NAS) were applied to calculate the SNR and LOD of independent CHO cell culture samples. By reducing fluorescence interference, improving the SNR and LOD, TGRS enhanced the detectability of five key analytes in the cell culture samples, facilitating accurate monitoring and detection of analytes in a complex bioprocess system, thereby demonstrating its viability as a PAT tool for upstream bioprocess environment. Graphical abstract
- 20 December 2025
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 49 (2) , 385-401
Open AccessEnhancing analytical sensitivity in upstream bioprocess using time-gated Raman spectroscopy
Upstream bioprocessing is a very complex system and requires rapid responses to process deviations. Mammalian cell culture processes are conventionally monitored for process-related and cell growth-related parameters, including pH, dissolved oxygen, viable cell density, cell viability, and key analyte concentrations that serve as primary indicators of the metabolic state of the cell culture. Raman spectroscopy (RS) has been increasingly applied as a viable inline process analytical technology (PAT) tool for cell culture monitoring and prediction of key analytes and attributes. The primary limitation to RS in these measurements is fluorescence (also referred to as sample-induced fluorescence), which interferes with the Raman signal and creates noise that makes detection of the signal from the analytes difficult. As a result, fluorescence interference decreases the signal to noise ratio (SNR) of the acquired spectra and increases the limit of detection (LOD) of analytical methods. Time-gated Raman spectroscopy (TGRS) takes advantage of the temporal delay between inelastic light scatter (Raman signal) and fluorescence emission to reduce interference from fluorescence. In this study, a pure component modeling approach and Net Analyte Signal (NAS) were applied to calculate the SNR and LOD of independent CHO cell culture samples. By reducing fluorescence interference, improving the SNR and LOD, TGRS enhanced the detectability of five key analytes in the cell culture samples, facilitating accurate monitoring and detection of analytes in a complex bioprocess system, thereby demonstrating its viability as a PAT tool for upstream bioprocess environment. Graphical abstract
- Open Access
- 24 June 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 681, 125897
Increasing continuous granulation process understanding: principal component analysis of granule size distributions
- 24 June 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 681, 125897
Open AccessIncreasing continuous granulation process understanding: principal component analysis of granule size distributions
- Open Access
- 19 June 2024
- Published by Springer Nature in Journal of Pharmaceutical Innovation
- Vol. 19 (3) , 1-5
Defining the Range of Calibration Burden: From Full Calibration to Calibration-Free
The expansion of spectroscopic process analytical technology (PAT) within the pharmaceutical industry requires chemometric models to enable spectral interpretation. However, calibration of chemometric models often require an intense time, material, and financial burden which may discourage PAT deployment. The advancement of modeling strategies that reduce this calibration burden necessitates consistent terminology for describing model inputs and overall calibration burden throughout chemometric literature. The goal of this article is to define levels of calibration burden by clarifying dataset classifications and model inputs during PAT method development. The scope of this work is specific to calibration of chemometric models incorporated in PAT methods. Harmonizing the language used in the field of chemometrics to describe calibration burden benefits both pharmaceutical manufacturers and regulatory agencies.
- 19 June 2024
- Published by Springer Nature in Journal of Pharmaceutical Innovation
- Vol. 19 (3) , 1-5
Open AccessDefining the Range of Calibration Burden: From Full Calibration to Calibration-Free
The expansion of spectroscopic process analytical technology (PAT) within the pharmaceutical industry requires chemometric models to enable spectral interpretation. However, calibration of chemometric models often require an intense time, material, and financial burden which may discourage PAT deployment. The advancement of modeling strategies that reduce this calibration burden necessitates consistent terminology for describing model inputs and overall calibration burden throughout chemometric literature. The goal of this article is to define levels of calibration burden by clarifying dataset classifications and model inputs during PAT method development. The scope of this work is specific to calibration of chemometric models incorporated in PAT methods. Harmonizing the language used in the field of chemometrics to describe calibration burden benefits both pharmaceutical manufacturers and regulatory agencies.
- 3 April 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 657, 124079
Development of iterative optimization technology: Selecting pure component spectra using a small-scale feed frame simulator
- 3 April 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 657, 124079
Development of iterative optimization technology: Selecting pure component spectra using a small-scale feed frame simulator
- 10 December 2023
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 650, 123699
Continuous manufacturing of pharmaceutical products: A density-insensitive near infrared method for the in-line monitoring of continuous powder streams
- 10 December 2023
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 650, 123699
Continuous manufacturing of pharmaceutical products: A density-insensitive near infrared method for the in-line monitoring of continuous powder streams
- 16 October 2023
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 243
Diagnostic development using net analyte signal for pure component modeling approaches
- 16 October 2023
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 243
Diagnostic development using net analyte signal for pure component modeling approaches
- 28 August 2023
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 645, 123354
Influence of powder stream density on near infrared measurements upon scale-up of a simulated continuous process
- 28 August 2023
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 645, 123354
Influence of powder stream density on near infrared measurements upon scale-up of a simulated continuous process