Nicholas A. Cellar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicholas A. Cellar has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Robert T. Kennedy
Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA
6 shared publications Christopher J. Watson
Department of Chemistry, University of Michigan, Ann Arbor, MI, United States
3 shared publicationsMarsha L. Langhorst
Analytical Sciences, 1897 Building, The Dow Chemical Company, Midland, Michigan 48667, USA
3 shared publicationsScott A. Young
Analytical Sciences, 1897 Building, The Dow Chemical Company, Midland, Michigan 48667
3 shared publicationsHao Chen
Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109-1120, USA
2 shared publicationsAnton S. Karnoup
The Dow Chemical Company, Analytical Sciences, Midland, MI 48667, USA
1 shared publication
Latest Publications
- 18 May 2010
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 58 (11) , 6614-6620
Determination of F2-Isoprostanes in Urine by Online Solid Phase Extraction Coupled to Liquid Chromatography with Tandem Mass Spectrometry
F(2)-isoprostanes are a unique class of prostaglandin-like compounds formed in vivo, which have been established as biomarkers of oxidative stress. Accurate analysis has been challenging due to lack of specificity for the isoforms of isoprostanes and lengthy sample preparation procedures to enable trace quantitative analysis. A quantitative analytical method was developed for the determination of F(2)-isoprostanes in rat and hamster urine by online solid phase extraction (SPE) coupled with liquid chromatography and tandem mass spectrometry (LC-MS/MS). The online SPE LC-MS/MS procedure has significant advantages over alternative methods with respect to specificity, sensitivity, simplicity, and speed. The assay enables the detection of iPF(2alpha)-III, iPF(2alpha)-IV, and iPF(2alpha)-VI over a linear dynamic range of 0.1-50 ng/mL in rat urine samples. This range covers the basal levels of these F(2)-isoprostanes. The limit of quantitation (LOQ) for the standard isoprostanes was about 0.3 ng/mL. The average recoveries ranged from 73 to 115% depending upon the individual F(2)-isoprostane isomers in rat urine. Additionally, the method was used to determine increases of endogenous urine iPF(2alpha)-VI and iPF(2alpha)-III in hamsters challenged with either low-fat or high-fat diets.
- 18 May 2010
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 58 (11) , 6614-6620
Determination of F2-Isoprostanes in Urine by Online Solid Phase Extraction Coupled to Liquid Chromatography with Tandem Mass Spectrometry
F(2)-isoprostanes are a unique class of prostaglandin-like compounds formed in vivo, which have been established as biomarkers of oxidative stress. Accurate analysis has been challenging due to lack of specificity for the isoforms of isoprostanes and lengthy sample preparation procedures to enable trace quantitative analysis. A quantitative analytical method was developed for the determination of F(2)-isoprostanes in rat and hamster urine by online solid phase extraction (SPE) coupled with liquid chromatography and tandem mass spectrometry (LC-MS/MS). The online SPE LC-MS/MS procedure has significant advantages over alternative methods with respect to specificity, sensitivity, simplicity, and speed. The assay enables the detection of iPF(2alpha)-III, iPF(2alpha)-IV, and iPF(2alpha)-VI over a linear dynamic range of 0.1-50 ng/mL in rat urine samples. This range covers the basal levels of these F(2)-isoprostanes. The limit of quantitation (LOQ) for the standard isoprostanes was about 0.3 ng/mL. The average recoveries ranged from 73 to 115% depending upon the individual F(2)-isoprostane isomers in rat urine. Additionally, the method was used to determine increases of endogenous urine iPF(2alpha)-VI and iPF(2alpha)-III in hamsters challenged with either low-fat or high-fat diets.
- 25 June 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (15) , 6110-6113
Electromechanical Properties of Pressure-Actuated Poly(dimethylsiloxane) Microfluidic Push-Down Valves
Pressure-actuated poly(dimethylsiloxane) (PDMS) valves have been characterized with respect to their electromechanical properties. Measurements of the valve opening and closing times, threshold pressures, and impedance spectra for closed valves can be used to assess the quality of the devices in general, determine their suitability for specialized applications, such as providing electrical isolated fluidic compartments for planar patch clamping, and specify ideal operating conditions. For our particular valve designs, we report valve opening times of the order of 10−100 μs, making them suitable for rapid buffer exchange applications. They can effectively provide reversible electrical isolation between adjacent fluidic compartments with typical resistances of 5 GΩ in the closed state, which meets the gigaohm requirement for patch clamping applications.
- 25 June 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (15) , 6110-6113
Electromechanical Properties of Pressure-Actuated Poly(dimethylsiloxane) Microfluidic Push-Down Valves
Pressure-actuated poly(dimethylsiloxane) (PDMS) valves have been characterized with respect to their electromechanical properties. Measurements of the valve opening and closing times, threshold pressures, and impedance spectra for closed valves can be used to assess the quality of the devices in general, determine their suitability for specialized applications, such as providing electrical isolated fluidic compartments for planar patch clamping, and specify ideal operating conditions. For our particular valve designs, we report valve opening times of the order of 10−100 μs, making them suitable for rapid buffer exchange applications. They can effectively provide reversible electrical isolation between adjacent fluidic compartments with typical resistances of 5 GΩ in the closed state, which meets the gigaohm requirement for patch clamping applications.
- 1 January 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 861 (1) , 29-39
Cross species applicability of abundant protein depletion columns for ribulose-1,5-bisphosphate carboxylase/oxygenase
- 1 January 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 861 (1) , 29-39
Cross species applicability of abundant protein depletion columns for ribulose-1,5-bisphosphate carboxylase/oxygenase
- 1 January 2007
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 159 (1) , 86-92
Microdialysis coupled on-line to capillary liquid chromatography with tandem mass spectrometry for monitoring acetylcholine in vivo
- 1 January 2007
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 159 (1) , 86-92
Microdialysis coupled on-line to capillary liquid chromatography with tandem mass spectrometry for monitoring acetylcholine in vivo
- 20 July 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (9) , 1205-1212
A capillary–PDMS hybrid chip for separations-based sensing of neurotransmitters in vivo
A chip fabricated by multilayer soft lithography of poly(dimethylsiloxane) was created for separations-based sensing of neurotransmitters in vivo. The chip incorporated a pneumatically actuated peristaltic pump and valving system to combine low-flow push–pull perfusion sampling, on-line derivatization, and flow-gated injection onto an embedded fused-silica capillary for high speed separation of amine neurotransmitters from the brain of living animals. Six 160 µm wide by 10 µm high control channels, actuated with an overlapping 60° pulse sequence, simultaneously drove sample and buffers through fluidic channels of the same dimensions. Tunable sampling flow rates of 40 to 130 nL min−1 and separation buffer flow rates of 380 to 850 nL min−1 were achieved with actuation frequencies between 3 and 10 Hz. On-line sampling of amine neurotransmitters with separation efficiencies in excess of 250 000 plates, detection limits of ∼40 nM, and relative standard deviations of 4% for glutamate and aspartate were achieved in vitro. Electropherograms with resolution of γ-aminobutyric acid, glutamine, taurine, serine, glycine, o-phosphorylethanolamine, glutamate, and aspartate could be collected every 30 s for over 4 h in vivo. It was also shown that pharmacological agents could be delivered and subsequent changes in neurotransmitter profile could be measured when delivering either 70 mM K+ artificial cerebrospinal fluid or 200 µM L-trans-pyrrolidine-2,4-dicarboxilic acid with the chip. These results demonstrate the ability of this chip to sample and monitor chemicals in the complex environment of the central nervous system with high selectivity and sensitivity over extended periods.
- 20 July 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (9) , 1205-1212
A capillary–PDMS hybrid chip for separations-based sensing of neurotransmitters in vivo
A chip fabricated by multilayer soft lithography of poly(dimethylsiloxane) was created for separations-based sensing of neurotransmitters in vivo. The chip incorporated a pneumatically actuated peristaltic pump and valving system to combine low-flow push–pull perfusion sampling, on-line derivatization, and flow-gated injection onto an embedded fused-silica capillary for high speed separation of amine neurotransmitters from the brain of living animals. Six 160 µm wide by 10 µm high control channels, actuated with an overlapping 60° pulse sequence, simultaneously drove sample and buffers through fluidic channels of the same dimensions. Tunable sampling flow rates of 40 to 130 nL min−1 and separation buffer flow rates of 380 to 850 nL min−1 were achieved with actuation frequencies between 3 and 10 Hz. On-line sampling of amine neurotransmitters with separation efficiencies in excess of 250 000 plates, detection limits of ∼40 nM, and relative standard deviations of 4% for glutamate and aspartate were achieved in vitro. Electropherograms with resolution of γ-aminobutyric acid, glutamine, taurine, serine, glycine, o-phosphorylethanolamine, glutamate, and aspartate could be collected every 30 s for over 4 h in vivo. It was also shown that pharmacological agents could be delivered and subsequent changes in neurotransmitter profile could be measured when delivering either 70 mM K+ artificial cerebrospinal fluid or 200 µM L-trans-pyrrolidine-2,4-dicarboxilic acid with the chip. These results demonstrate the ability of this chip to sample and monitor chemicals in the complex environment of the central nervous system with high selectivity and sensitivity over extended periods.
- 1 February 2006
- Published by Elsevier in Biophysical Journal
- Vol. 90 (4) , 1249-1259
Solid-State NMR Studies of a Diverged Microsomal Amino-Proximate Δ12 Desaturase Peptide Reveal Causes of Stability in Bilayer: Tyrosine Anchoring and Arginine Snorkeling
- 1 February 2006
- Published by Elsevier in Biophysical Journal
- Vol. 90 (4) , 1249-1259
Solid-State NMR Studies of a Diverged Microsomal Amino-Proximate Δ12 Desaturase Peptide Reveal Causes of Stability in Bilayer: Tyrosine Anchoring and Arginine Snorkeling
- 4 October 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (21) , 7067-7073
Microfluidic Chip for Low-Flow Push-Pull Perfusion Sampling in Vivo with On-Line Analysis of Amino Acids
Multilayer soft lithography was used to prepare a poly(dimethylsiloxane) microfluidic chip that allows for in vivo sampling of amino acid neurotransmitters by low-flow push−pull perfusion. The chip incorporates a pneumatically actuated peristaltic pump to deliver artificial cerebrospinal fluid to a push−pull perfusion probe, pull sample from the probe, perform on-line derivatization with o-phthaldialdehyde, and push derivatized amino acids into the flow-gated injector of a high-speed capillary electrophoresis−laser-induced fluorescence instrument. Peristalsis was achieved by sequential actuation of six, 200 μm wide by 15 μm high control valves that drove fluid through three fluidic channels of equal dimensions. Electropherograms with 100 000 theoretical plates were acquired at ∼20-s intervals. Relative standard deviations of peak heights were 4% in vitro, and detection limits for the excitatory amino acids were ∼60 nM. For in vivo measurements, push−pull probes were implanted in the striatum of anesthetized rats and amino acid concentrations were monitored while sampling at 50 nL/min. o-Phosphorylethanolamine, glutamate, aspartate, taurine, glutamine, serine, and glycine were all detected with stable peak heights observed for over 4 h with relative standard deviations of 10% in vivo. Basal concentrations of glutamate were 1.9 ± 0.6 μM (n = 4) in good agreement with similar methods. Monitoring of dynamic changes of neurotransmitters resulting from 10-min applications of 70 mM K+ through the push channel of the pump was demonstrated. The combined system allows temporal resolution for multianalyte monitoring of ∼45 s with spatial resolution 65-fold better than conventional microdialysis probe with 4-mm length. The system demonstrates the feasibility of sampling from a complex microenvironment with transfer to a microfluidic device for on-line analysis.
- 4 October 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (21) , 7067-7073
Microfluidic Chip for Low-Flow Push-Pull Perfusion Sampling in Vivo with On-Line Analysis of Amino Acids
Multilayer soft lithography was used to prepare a poly(dimethylsiloxane) microfluidic chip that allows for in vivo sampling of amino acid neurotransmitters by low-flow push−pull perfusion. The chip incorporates a pneumatically actuated peristaltic pump to deliver artificial cerebrospinal fluid to a push−pull perfusion probe, pull sample from the probe, perform on-line derivatization with o-phthaldialdehyde, and push derivatized amino acids into the flow-gated injector of a high-speed capillary electrophoresis−laser-induced fluorescence instrument. Peristalsis was achieved by sequential actuation of six, 200 μm wide by 15 μm high control valves that drove fluid through three fluidic channels of equal dimensions. Electropherograms with 100 000 theoretical plates were acquired at ∼20-s intervals. Relative standard deviations of peak heights were 4% in vitro, and detection limits for the excitatory amino acids were ∼60 nM. For in vivo measurements, push−pull probes were implanted in the striatum of anesthetized rats and amino acid concentrations were monitored while sampling at 50 nL/min. o-Phosphorylethanolamine, glutamate, aspartate, taurine, glutamine, serine, and glycine were all detected with stable peak heights observed for over 4 h with relative standard deviations of 10% in vivo. Basal concentrations of glutamate were 1.9 ± 0.6 μM (n = 4) in good agreement with similar methods. Monitoring of dynamic changes of neurotransmitters resulting from 10-min applications of 70 mM K+ through the push channel of the pump was demonstrated. The combined system allows temporal resolution for multianalyte monitoring of ∼45 s with spatial resolution 65-fold better than conventional microdialysis probe with 4-mm length. The system demonstrates the feasibility of sampling from a complex microenvironment with transfer to a microfluidic device for on-line analysis.
- 10 February 2005
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 40 (2) , 146-153
Capillary liquid chromatography with MS3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats
In vivo microdialysis sampling was coupled to capillary liquid chromatography (LC)/electrospray ionization quadrupole ion trap mass spectrometry (MS) to monitor [Met]enkephalin and [Leu]enkephalin in the striatum of anesthetized and freely–moving rats. The LC system utilized a high‐pressure pump to load 2.5 µl samples and desalt the 25 µm i.d. by 2 cm long column in 12 min. Samples were eluted with a separate pump at ∼100 nl min−1. A rapid gradient effectively separated the endogenous neuropeptides in 4 min. A comparison was made for operating the mass spectrometer in the MS2 and MS3 modes for detection of the peptides. In standard solutions, the detection limits were similar at 1–2 pM (2–4 amol injected); however, the reproducibility was improved with MS3 as the relative standard deviation was 2 for 60 pM samples. For dialysate solutions, reconstructed ion chromatograms and tandem mass spectra had much higher signal‐to‐noise ratios in the MS3 mode, resulting in more confident detection at in vivo concentrations. The method was successfully used to monitor the peptides under basal conditions and with stimulation of peptide secretion by infusion of elevated K+ concentration. Copyright © 2005 John Wiley & Sons, Ltd.
- 10 February 2005
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 40 (2) , 146-153
Capillary liquid chromatography with MS3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats
In vivo microdialysis sampling was coupled to capillary liquid chromatography (LC)/electrospray ionization quadrupole ion trap mass spectrometry (MS) to monitor [Met]enkephalin and [Leu]enkephalin in the striatum of anesthetized and freely–moving rats. The LC system utilized a high‐pressure pump to load 2.5 µl samples and desalt the 25 µm i.d. by 2 cm long column in 12 min. Samples were eluted with a separate pump at ∼100 nl min−1. A rapid gradient effectively separated the endogenous neuropeptides in 4 min. A comparison was made for operating the mass spectrometer in the MS2 and MS3 modes for detection of the peptides. In standard solutions, the detection limits were similar at 1–2 pM (2–4 amol injected); however, the reproducibility was improved with MS3 as the relative standard deviation was 2 for 60 pM samples. For dialysate solutions, reconstructed ion chromatograms and tandem mass spectra had much higher signal‐to‐noise ratios in the MS3 mode, resulting in more confident detection at in vivo concentrations. The method was successfully used to monitor the peptides under basal conditions and with stimulation of peptide secretion by infusion of elevated K+ concentration. Copyright © 2005 John Wiley & Sons, Ltd.
- 6 August 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (18) , 5523-5533
Discovery and Neurochemical Screening of Peptides in Brain Extracellular Fluid by Chemical Analysis of in Vivo Microdialysis Samples
Endogenous peptides from brain extracellular fluid of live rats were analyzed using capillary liquid chromatography (LC)−tandem mass spectrometry (MS2). A 4-mm-long microdialysis probe perfused at 0.6 μL/min implanted into the striatum of anesthetized male rats was used to collect 3.6 μL dialysate fractions that were injected on-line into the capillary LC−MS2 system for analysis. A total of 3349 MS2 spectra were collected from 13 different animals under basal conditions and during localized depolarization evoked by infusion of a high-K+ solution through the microdialysis probe. Subtractive analysis revealed a total of 859 MS2 spectra that were observed only during depolarization. From these spectra, 29 peptide sequences (25 were peptides not previously observed) from 6 different protein precursors were identified using database searching software. Proteins identified include precursors to neuropeptides, synaptic proteins, blood proteins, and transporters. The identified peptides represent candidates for neurotransmitters, neuromodulators, and markers of synaptic activity or brain tissue damage. A screen for neuroactivity of novel proenkephalin fragments that were found was performed by infusing the peptides into the brain while monitoring amino acid neurotransmitters by microdialysis sampling combined with capillary electrophoresis. Three of the six tested peptides evoked significant increases in various neuroactive amino acids. These results demonstrate that this combination of methods can identify novel neurotransmitter candidates and screen for potential neuroactivity.
- 6 August 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (18) , 5523-5533
Discovery and Neurochemical Screening of Peptides in Brain Extracellular Fluid by Chemical Analysis of in Vivo Microdialysis Samples
Endogenous peptides from brain extracellular fluid of live rats were analyzed using capillary liquid chromatography (LC)−tandem mass spectrometry (MS2). A 4-mm-long microdialysis probe perfused at 0.6 μL/min implanted into the striatum of anesthetized male rats was used to collect 3.6 μL dialysate fractions that were injected on-line into the capillary LC−MS2 system for analysis. A total of 3349 MS2 spectra were collected from 13 different animals under basal conditions and during localized depolarization evoked by infusion of a high-K+ solution through the microdialysis probe. Subtractive analysis revealed a total of 859 MS2 spectra that were observed only during depolarization. From these spectra, 29 peptide sequences (25 were peptides not previously observed) from 6 different protein precursors were identified using database searching software. Proteins identified include precursors to neuropeptides, synaptic proteins, blood proteins, and transporters. The identified peptides represent candidates for neurotransmitters, neuromodulators, and markers of synaptic activity or brain tissue damage. A screen for neuroactivity of novel proenkephalin fragments that were found was performed by infusing the peptides into the brain while monitoring amino acid neurotransmitters by microdialysis sampling combined with capillary electrophoresis. Three of the six tested peptides evoked significant increases in various neuroactive amino acids. These results demonstrate that this combination of methods can identify novel neurotransmitter candidates and screen for potential neuroactivity.