Manuel Jorge Marques
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manuel Jorge Marques has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Gh. Podoleanu
University of Kent
22 shared publications - Adrian Bradu
Applied Optics Group, School of Engineering, Mathematics and Physics, University of Kent, CT2 7NH, Canterbury, United Kingdom
12 shared publications - Michael Hughes
University of Kent
5 shared publications Sylvain Rivet
Laboratoire d’Optique et de Magnétisme, Université de Bretagne Occidentale, IBSAM, 6 avenue Le Gorgeu, 29238 Brest Cedex 3, France
5 shared publicationsAdrian Bradu
Applied Optics Group, University of Kent, Canterbury CT2 7NH, Kent, UK
4 shared publications- Adrian Fernandez Uceda
University of Kent
2 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5920
Ultra-thin, forward-viewing OCT endoscope using a rotating angle-cleaved fiber
While ultra-thin optical coherence tomography (OCT) probes using rotating fibers have been demonstrated in side-viewing configurations, achieving fully miniaturized forward-viewing OCT endoscopy remains challenging because of the need to incorporate a lateral scanning mechanism. Here, we report a forward-viewing OCT fiber endoscope that can fit inside a protective tube with an inner diameter of 0.16 mm, enabling an endoscope with an outer diameter of 0.31 mm. The rotating fiber assembly incorporates a gradient-index fiber lens and an angle-cleaved length of no-core fiber at the distal tip. This causes the beam to exit at an angle to the endoscope axis, such that rotating the fiber using an external rotary coupler generates circular scanning of the beam over the tissue. Lateral and axial resolutions of 25 µm and 11 µm, respectively, are achieved at focus, with a usable imaging depth range of over 2 mm and an image circle circumference of 950 µm at 1 mm from the fiber tip. An exemplar application in vitreoretinal surgery is demonstrated by ex vivo porcine retinal imaging and real-time monitoring of a surgical tool interacting with the tissue.
- 26 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5920
Open AccessUltra-thin, forward-viewing OCT endoscope using a rotating angle-cleaved fiber
While ultra-thin optical coherence tomography (OCT) probes using rotating fibers have been demonstrated in side-viewing configurations, achieving fully miniaturized forward-viewing OCT endoscopy remains challenging because of the need to incorporate a lateral scanning mechanism. Here, we report a forward-viewing OCT fiber endoscope that can fit inside a protective tube with an inner diameter of 0.16 mm, enabling an endoscope with an outer diameter of 0.31 mm. The rotating fiber assembly incorporates a gradient-index fiber lens and an angle-cleaved length of no-core fiber at the distal tip. This causes the beam to exit at an angle to the endoscope axis, such that rotating the fiber using an external rotary coupler generates circular scanning of the beam over the tissue. Lateral and axial resolutions of 25 µm and 11 µm, respectively, are achieved at focus, with a usable imaging depth range of over 2 mm and an image circle circumference of 950 µm at 1 mm from the fiber tip. An exemplar application in vitreoretinal surgery is demonstrated by ex vivo porcine retinal imaging and real-time monitoring of a surgical tool interacting with the tissue.
- Open Access
- 29 September 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 37906
Real-time en-face optical coherence tomography using a 9 GHz photodetected signal
A modality of down-conversion leader-follower optical coherence tomography (OCT) is evaluated for delivering an en-face OCT image when the photodetected signal pulsates at 4-9 GHz. En-face images are demonstrated from an object extending over 1.6 cm employing an I&Q demodulator and a digitizer of only 250 kS/s when using a VCSEL swept source at 100 kHz. The method presented responds to the need to provide guidance in adjusting the position and orientation of the sample to be investigated in front of the scanning head of a fast swept-source OCT system that, due to the combined effect of sweeping speed and large data, cannot provide images in real-time.
- 29 September 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 37906
Open AccessReal-time en-face optical coherence tomography using a 9 GHz photodetected signal
A modality of down-conversion leader-follower optical coherence tomography (OCT) is evaluated for delivering an en-face OCT image when the photodetected signal pulsates at 4-9 GHz. En-face images are demonstrated from an object extending over 1.6 cm employing an I&Q demodulator and a digitizer of only 250 kS/s when using a VCSEL swept source at 100 kHz. The method presented responds to the need to provide guidance in adjusting the position and orientation of the sample to be investigated in front of the scanning head of a fast swept-source OCT system that, due to the combined effect of sweeping speed and large data, cannot provide images in real-time.
- Open Access
- 6 May 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (10) , 17833-17846
Time-domain optical coherence tomography at 2 µm using GaSb-based broadband superluminescent diode
We report a time-domain optical coherence tomography (TD-OCT) system operating in the 2 µm spectral region, enabled by a GaSb-based superluminescent diode (SLD). The spectrum emitted by the SLD exhibits a full-width half-maximum (FWHM) of ∼80 nm centered near 2.1 µm. For OCT operation, stable amplified spontaneous emission with low spectral ripple (<20%) is maintained at drive currents below 150 mA. The SLD is fiber coupled and integrated into a fiber-based Michelson interferometer. In the OCT system, the measured coherence envelope yields an axial resolution of approximately 300 µm in air and enables depth-resolved imaging of scattering paint-based coating samples. In contrast to OCT implementations at 2 µm wavelength region that commonly rely on supercontinuum sources, the use of GaSb-based SLDs offers a compact, practical alternative, leveraging the maturity and scalability of electrically driven semiconductor light sources packaged in a standard “butterfly” module. This report represents the first demonstration of TD-OCT imaging at 2 µm using a GaSb-based SLD source and establishes its suitability for compact and scalable mid-IR OCT instrumentation targeting non-biological, low-water-content materials.
- 6 May 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (10) , 17833-17846
Open AccessTime-domain optical coherence tomography at 2 µm using GaSb-based broadband superluminescent diode
We report a time-domain optical coherence tomography (TD-OCT) system operating in the 2 µm spectral region, enabled by a GaSb-based superluminescent diode (SLD). The spectrum emitted by the SLD exhibits a full-width half-maximum (FWHM) of ∼80 nm centered near 2.1 µm. For OCT operation, stable amplified spontaneous emission with low spectral ripple (<20%) is maintained at drive currents below 150 mA. The SLD is fiber coupled and integrated into a fiber-based Michelson interferometer. In the OCT system, the measured coherence envelope yields an axial resolution of approximately 300 µm in air and enables depth-resolved imaging of scattering paint-based coating samples. In contrast to OCT implementations at 2 µm wavelength region that commonly rely on supercontinuum sources, the use of GaSb-based SLDs offers a compact, practical alternative, leveraging the maturity and scalability of electrically driven semiconductor light sources packaged in a standard “butterfly” module. This report represents the first demonstration of TD-OCT imaging at 2 µm using a GaSb-based SLD source and establishes its suitability for compact and scalable mid-IR OCT instrumentation targeting non-biological, low-water-content materials.
- Open Access
- 3 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (20) , 5748-5753
Fabrication and testing of lensed fiber-optic probes for distance sensing using common-path low-coherence interferometry
Common-path low-coherence interferometry enables high-resolution distance measurements to be made via thin fiber-optic probes. This is particularly advantageous for applications such as ophthalmic vitreoretinal microsurgery, where the probes can be used to precisely locate the position of surgical tools relative to the retinal surface, but could also have a wide range of other medical and industrial applications. The performance of the fiber probes depends critically on the fabrication of a focusing lens at the distal tip and on creating a medium-independent partial reflection that is used for common-path interferometry. These are complex multi-step procedures that are not fully described in the literature. In this note, we detail a procedure to manufacture probes by fusing coreless and gradient index sections of fiber to single-mode fiber and to apply a thin gold coating to act as a partial reflector. We also explain how quality control of the fabrication can be performed, demonstrate how the probes can be coupled to a common-path swept-source interferometer, and describe algorithms to convert raw data to distance measurements. These procedures are intended to aid researchers in developing their own customized probes and develop new applications for distance sensors.
- 3 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (20) , 5748-5753
Open AccessFabrication and testing of lensed fiber-optic probes for distance sensing using common-path low-coherence interferometry
Common-path low-coherence interferometry enables high-resolution distance measurements to be made via thin fiber-optic probes. This is particularly advantageous for applications such as ophthalmic vitreoretinal microsurgery, where the probes can be used to precisely locate the position of surgical tools relative to the retinal surface, but could also have a wide range of other medical and industrial applications. The performance of the fiber probes depends critically on the fabrication of a focusing lens at the distal tip and on creating a medium-independent partial reflection that is used for common-path interferometry. These are complex multi-step procedures that are not fully described in the literature. In this note, we detail a procedure to manufacture probes by fusing coreless and gradient index sections of fiber to single-mode fiber and to apply a thin gold coating to act as a partial reflector. We also explain how quality control of the fabrication can be performed, demonstrate how the probes can be coupled to a common-path swept-source interferometer, and describe algorithms to convert raw data to distance measurements. These procedures are intended to aid researchers in developing their own customized probes and develop new applications for distance sensors.
- 12 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13187, 21-33
Temperature dependence of a depth-encoded system for polarization-sensitive optical coherence tomography using a PM fiber
With the aim of applying complex master/slave interferometry (CMSI) to polarizationsensitive optical coherence tomography (PS-OCT) for birefringent tomographic measurements of biological tissue, we present the impact of temperature instability on an all-fiber-based depth-encoded PS-OCT system and the practicality of temperature control for birefringence measurements. In our PS-OCT system, two orthogonally polarized interrogating beams were separated to a depth of approximately 1 mm using a 5-meter long polarization-maintaining fiber (PMF) as a passive delay unit, which is susceptible to temperature instability. The variation in resolution and delay due to temperature change of PMF were investigated. Furthermore, it is shown that tomographic birefringence can be measured under temperature-controlled operation utilizing the advantages of CMSI. We found that changes to the location of generated masks caused by an emerging temperature drift between the channels can be corrected with our presented characterization.
- 12 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13187, 21-33
Temperature dependence of a depth-encoded system for polarization-sensitive optical coherence tomography using a PM fiber
With the aim of applying complex master/slave interferometry (CMSI) to polarizationsensitive optical coherence tomography (PS-OCT) for birefringent tomographic measurements of biological tissue, we present the impact of temperature instability on an all-fiber-based depth-encoded PS-OCT system and the practicality of temperature control for birefringence measurements. In our PS-OCT system, two orthogonally polarized interrogating beams were separated to a depth of approximately 1 mm using a 5-meter long polarization-maintaining fiber (PMF) as a passive delay unit, which is susceptible to temperature instability. The variation in resolution and delay due to temperature change of PMF were investigated. Furthermore, it is shown that tomographic birefringence can be measured under temperature-controlled operation utilizing the advantages of CMSI. We found that changes to the location of generated masks caused by an emerging temperature drift between the channels can be corrected with our presented characterization.
- Open Access
- 26 February 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (3) , 324-337
Complex master-slave enhanced optical coherence microscopy
We present an instrument designed to facilitate localization and high-resolution, optical coherence microscopy (OCM) imaging of small biological samples immersed in a medium several orders of magnitude greater in volume. A modified turret-equipped microscope stand was inserted into the sample arm of a spectral domain optical coherence microscopy (SD-OCM) system. The instrument enabled swift change of imaging objectives through the incorporation of complex master-slave interferometry (CMSI), providing tolerance to dispersion for any objective through the acquisition of a few (≥2) calibration spectra. We demonstrate the instrument’s ability to localize and image samples by providing examples of its application to optical phantoms and to a porcine oocyte immersed in a biological culture medium.
- 26 February 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (3) , 324-337
Open AccessComplex master-slave enhanced optical coherence microscopy
We present an instrument designed to facilitate localization and high-resolution, optical coherence microscopy (OCM) imaging of small biological samples immersed in a medium several orders of magnitude greater in volume. A modified turret-equipped microscope stand was inserted into the sample arm of a spectral domain optical coherence microscopy (SD-OCM) system. The instrument enabled swift change of imaging objectives through the incorporation of complex master-slave interferometry (CMSI), providing tolerance to dispersion for any objective through the acquisition of a few (≥2) calibration spectra. We demonstrate the instrument’s ability to localize and image samples by providing examples of its application to optical phantoms and to a porcine oocyte immersed in a biological culture medium.
- 11 August 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12632, 47-147
Low-cost speckle reduction method for OCT B-scan imaging
The most successful methods for speckle reduction in Optical Coherence Tomography (OCT) are based on deformation of the wavefront used in scanning. Here, a simple method is presented where the wavefront is distorted by lateral translation of the lens between the 2D galvo-scanner and sample. The report demonstrates that the method can be implemented with a small piezoelectric transducer. Up to 33% improvement in Speckle Contrast Ratio (SCR) of B-scan OCT images is demonstrated.
- 11 August 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12632, 47-147
Low-cost speckle reduction method for OCT B-scan imaging
The most successful methods for speckle reduction in Optical Coherence Tomography (OCT) are based on deformation of the wavefront used in scanning. Here, a simple method is presented where the wavefront is distorted by lateral translation of the lens between the 2D galvo-scanner and sample. The report demonstrates that the method can be implemented with a small piezoelectric transducer. Up to 33% improvement in Speckle Contrast Ratio (SCR) of B-scan OCT images is demonstrated.
- Open Access
- 14 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 761-776
Endoscopic en-face optical coherence tomography and fluorescence imaging using correlation-based probe tracking
Forward-viewing endoscopic optical coherence tomography (OCT) provides 3D imaging in vivo, and can be combined with widefield fluorescence imaging by use of a double-clad fiber. However, it is technically challenging to build a high-performance miniaturized 2D scanning system with a large field-of-view. In this paper we demonstrate how a 1D scanning probe, which produces cross-sectional OCT images (B-scans) and 1D fluorescence T-scans, can be transformed into a 2D scanning probe by manual scanning along the second axis. OCT volumes are assembled from the B-scans using speckle decorrelation measurements to estimate the out-of-plane motion along the manual scan direction. Motion within the plane of the B-scans is corrected using image registration by normalized cross correlation. En-face OCT slices and fluorescence images, corrected for probe motion in 3D, can be displayed in real-time during the scan. For a B-scan frame rate of 250 Hz, and an OCT lateral resolution of approximately 20 μ m , the approach can handle out-of-plane motion at speeds of up to 4 mm/s.
- 14 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 761-776
Open AccessEndoscopic en-face optical coherence tomography and fluorescence imaging using correlation-based probe tracking
Forward-viewing endoscopic optical coherence tomography (OCT) provides 3D imaging in vivo, and can be combined with widefield fluorescence imaging by use of a double-clad fiber. However, it is technically challenging to build a high-performance miniaturized 2D scanning system with a large field-of-view. In this paper we demonstrate how a 1D scanning probe, which produces cross-sectional OCT images (B-scans) and 1D fluorescence T-scans, can be transformed into a 2D scanning probe by manual scanning along the second axis. OCT volumes are assembled from the B-scans using speckle decorrelation measurements to estimate the out-of-plane motion along the manual scan direction. Motion within the plane of the B-scans is corrected using image registration by normalized cross correlation. En-face OCT slices and fluorescence images, corrected for probe motion in 3D, can be displayed in real-time during the scan. For a B-scan frame rate of 250 Hz, and an OCT lateral resolution of approximately 20 μ m , the approach can handle out-of-plane motion at speeds of up to 4 mm/s.
- Open Access
Akinetic Swept-Source Master–Slave-Enhanced Optical Coherence Tomography
This paper presents a different approach for processing the signal from interferometers driven by swept sources that exhibit non-linear tuning during stable time intervals. Such sources are, for example, those commercialised by Insight, which are electrically tunable and akinetic. These Insight sources use a calibration procedure to skip frequencies already included in a spectral sweep, i.e., a process of “clearing the spectrum”. For the first time, the suitability of the Master–Slave (MS) procedure is evaluated as an alternative to the conventional calibration procedure for such sources. Here, the MS process is applied to the intact, raw interferogram spectrum delivered by an optical coherence tomography (OCT) system. Two modalities are investigated to implement the MS processing, based on (i) digital generation of the Master signals using the OCT interferometer and (ii) down-conversion using a second interferometer driven by the same swept source. The latter allows near-coherence-limited operation at a large axial range (>), without the need for a high sampling rate digitiser card to cope with the large frequency spectrum generated, which can exceed several GHz. In both cases, the depth information is recovered with some limitations as described in the text.Open AccessAkinetic Swept-Source Master–Slave-Enhanced Optical Coherence Tomography
This paper presents a different approach for processing the signal from interferometers driven by swept sources that exhibit non-linear tuning during stable time intervals. Such sources are, for example, those commercialised by Insight, which are electrically tunable and akinetic. These Insight sources use a calibration procedure to skip frequencies already included in a spectral sweep, i.e., a process of “clearing the spectrum”. For the first time, the suitability of the Master–Slave (MS) procedure is evaluated as an alternative to the conventional calibration procedure for such sources. Here, the MS process is applied to the intact, raw interferogram spectrum delivered by an optical coherence tomography (OCT) system. Two modalities are investigated to implement the MS processing, based on (i) digital generation of the Master signals using the OCT interferometer and (ii) down-conversion using a second interferometer driven by the same swept source. The latter allows near-coherence-limited operation at a large axial range (>), without the need for a high sampling rate digitiser card to cope with the large frequency spectrum generated, which can exceed several GHz. In both cases, the depth information is recovered with some limitations as described in the text. - 1 March 2021
- Published by Elsevier in Science & Justice
- Vol. 61 (2) , 119-129
Sub-surface characterisation of latest-generation identification documents using optical coherence tomography
- 1 March 2021
- Published by Elsevier in Science & Justice
- Vol. 61 (2) , 119-129
Sub-surface characterisation of latest-generation identification documents using optical coherence tomography