Latest Publications

  • Open Access

    Ultra-thin, forward-viewing OCT endoscope using a rotating angle-cleaved fiber

    by Radu-Florin Stancu, Michael Hughes, Manuel J. Marques, Carlo Seneci, Ross Henry, Sébastien Ourselin, Lyndon da Cruz, Christos Bergeles, Adrian Podoleanu

    While ultra-thin optical coherence tomography (OCT) probes using rotating fibers have been demonstrated in side-viewing configurations, achieving fully miniaturized forward-viewing OCT endoscopy remains challenging because of the need to incorporate a lateral scanning mechanism. Here, we report a forward-viewing OCT fiber endoscope that can fit inside a protective tube with an inner diameter of 0.16 mm, enabling an endoscope with an outer diameter of 0.31 mm. The rotating fiber assembly incorporates a gradient-index fiber lens and an angle-cleaved length of no-core fiber at the distal tip. This causes the beam to exit at an angle to the endoscope axis, such that rotating the fiber using an external rotary coupler generates circular scanning of the beam over the tissue. Lateral and axial resolutions of 25 µm and 11 µm, respectively, are achieved at focus, with a usable imaging depth range of over 2 mm and an image circle circumference of 950 µm at 1 mm from the fiber tip. An exemplar application in vitreoretinal surgery is demonstrated by ex vivo porcine retinal imaging and real-time monitoring of a surgical tool interacting with the tissue.

  • Open Access

    Real-time en-face optical coherence tomography using a 9 GHz photodetected signal

    by Ramona Cernat, Adrian Fernandez Uceda, Manuel Marques, Alejandro Martinez Jimenez, Adrian Podoleanu

    A modality of down-conversion leader-follower optical coherence tomography (OCT) is evaluated for delivering an en-face OCT image when the photodetected signal pulsates at 4-9 GHz. En-face images are demonstrated from an object extending over 1.6 cm employing an I&Q demodulator and a digitizer of only 250 kS/s when using a VCSEL swept source at 100 kHz. The method presented responds to the need to provide guidance in adjusting the position and orientation of the sample to be investigated in front of the scanning head of a fast swept-source OCT system that, due to the combined effect of sweeping speed and large data, cannot provide images in real-time.

  • Open Access

    Time-domain optical coherence tomography at 2 µm using GaSb-based broadband superluminescent diode

    by Ifte Khairul Alam Bhuiyan, Alejandro Martínez Jiménez, Ramona Cernat, Adrián Fernández Uceda, Joonas Hilska, Markus Peil, Manuel Jorge Marques, George Dobre, Jukka Viheriälä, Adrian Podoleanu, et al.

    We report a time-domain optical coherence tomography (TD-OCT) system operating in the 2 µm spectral region, enabled by a GaSb-based superluminescent diode (SLD). The spectrum emitted by the SLD exhibits a full-width half-maximum (FWHM) of ∼80 nm centered near 2.1 µm. For OCT operation, stable amplified spontaneous emission with low spectral ripple (<20%) is maintained at drive currents below 150 mA. The SLD is fiber coupled and integrated into a fiber-based Michelson interferometer. In the OCT system, the measured coherence envelope yields an axial resolution of approximately 300 µm in air and enables depth-resolved imaging of scattering paint-based coating samples. In contrast to OCT implementations at 2 µm wavelength region that commonly rely on supercontinuum sources, the use of GaSb-based SLDs offers a compact, practical alternative, leveraging the maturity and scalability of electrically driven semiconductor light sources packaged in a standard “butterfly” module. This report represents the first demonstration of TD-OCT imaging at 2 µm using a GaSb-based SLD source and establishes its suitability for compact and scalable mid-IR OCT instrumentation targeting non-biological, low-water-content materials.


  • Open Access

    Fabrication and testing of lensed fiber-optic probes for distance sensing using common-path low-coherence interferometry

    by Radu-Florin Stancu, Michael Hughes, Taylor Sanderson, Manuel Marques, Lyndon da Cruz, Christos Bergeles, Adrian Podoleanu

    Common-path low-coherence interferometry enables high-resolution distance measurements to be made via thin fiber-optic probes. This is particularly advantageous for applications such as ophthalmic vitreoretinal microsurgery, where the probes can be used to precisely locate the position of surgical tools relative to the retinal surface, but could also have a wide range of other medical and industrial applications. The performance of the fiber probes depends critically on the fabrication of a focusing lens at the distal tip and on creating a medium-independent partial reflection that is used for common-path interferometry. These are complex multi-step procedures that are not fully described in the literature. In this note, we detail a procedure to manufacture probes by fusing coreless and gradient index sections of fiber to single-mode fiber and to apply a thin gold coating to act as a partial reflector. We also explain how quality control of the fabrication can be performed, demonstrate how the probes can be coupled to a common-path swept-source interferometer, and describe algorithms to convert raw data to distance measurements. These procedures are intended to aid researchers in developing their own customized probes and develop new applications for distance sensors.


  • Temperature dependence of a depth-encoded system for polarization-sensitive optical coherence tomography using a PM fiber

    by Philipp Tatar-Mathes, Rasmus Eilkær Hansen, Samuel Choi, Manuel J. Marques, Niels Møller Israelsen, Adrian Podoleanu

    With the aim of applying complex master/slave interferometry (CMSI) to polarizationsensitive optical coherence tomography (PS-OCT) for birefringent tomographic measurements of biological tissue, we present the impact of temperature instability on an all-fiber-based depth-encoded PS-OCT system and the practicality of temperature control for birefringence measurements. In our PS-OCT system, two orthogonally polarized interrogating beams were separated to a depth of approximately 1 mm using a 5-meter long polarization-maintaining fiber (PMF) as a passive delay unit, which is susceptible to temperature instability. The variation in resolution and delay due to temperature change of PMF were investigated. Furthermore, it is shown that tomographic birefringence can be measured under temperature-controlled operation utilizing the advantages of CMSI. We found that changes to the location of generated masks caused by an emerging temperature drift between the channels can be corrected with our presented characterization.

  • Open Access

    Complex master-slave enhanced optical coherence microscopy

    by Julien Camard, Manuel J. Marques, Carla Canedo-Ribeiro, Giuseppe Silvestri, Peter Ellis, Gary Robinson, Alejandro Chávez-Badiola, Darren Griffin, Adrian Bradu, Adrian Podoleanu

    We present an instrument designed to facilitate localization and high-resolution, optical coherence microscopy (OCM) imaging of small biological samples immersed in a medium several orders of magnitude greater in volume. A modified turret-equipped microscope stand was inserted into the sample arm of a spectral domain optical coherence microscopy (SD-OCM) system. The instrument enabled swift change of imaging objectives through the incorporation of complex master-slave interferometry (CMSI), providing tolerance to dispersion for any objective through the acquisition of a few (≥2) calibration spectra. We demonstrate the instrument’s ability to localize and image samples by providing examples of its application to optical phantoms and to a porcine oocyte immersed in a biological culture medium.


  • Low-cost speckle reduction method for OCT B-scan imaging

    by Julien Camard, Manuel Jorge Marques, Marie-Claire Aquilina, Giuseppe Silvestri, Darren K. Griffin, Adrian Podoleanu

    The most successful methods for speckle reduction in Optical Coherence Tomography (OCT) are based on deformation of the wavefront used in scanning. Here, a simple method is presented where the wavefront is distorted by lateral translation of the lens between the 2D galvo-scanner and sample. The report demonstrates that the method can be implemented with a small piezoelectric transducer. Up to 33% improvement in Speckle Contrast Ratio (SCR) of B-scan OCT images is demonstrated.

  • Open Access

    Endoscopic en-face optical coherence tomography and fluorescence imaging using correlation-based probe tracking

    by Manuel J. Marques, Michael R. Hughes, Adrian Fernandez Uceda, Grigory Gelikonov, Adrian Bradu, Adrian Podoleanu

    Forward-viewing endoscopic optical coherence tomography (OCT) provides 3D imaging in vivo, and can be combined with widefield fluorescence imaging by use of a double-clad fiber. However, it is technically challenging to build a high-performance miniaturized 2D scanning system with a large field-of-view. In this paper we demonstrate how a 1D scanning probe, which produces cross-sectional OCT images (B-scans) and 1D fluorescence T-scans, can be transformed into a 2D scanning probe by manual scanning along the second axis. OCT volumes are assembled from the B-scans using speckle decorrelation measurements to estimate the out-of-plane motion along the manual scan direction. Motion within the plane of the B-scans is corrected using image registration by normalized cross correlation. En-face OCT slices and fluorescence images, corrected for probe motion in 3D, can be displayed in real-time during the scan. For a B-scan frame rate of 250 Hz, and an OCT lateral resolution of approximately 20 μ m , the approach can handle out-of-plane motion at speeds of up to 4 mm/s.


  • Open Access

    Akinetic Swept-Source Master–Slave-Enhanced Optical Coherence Tomography

    by Manuel J. Marques, Ramona Cernat, Jason Ensher, Adrian Bradu, Adrian Podoleanu

    This paper presents a different approach for processing the signal from interferometers driven by swept sources that exhibit non-linear tuning during stable time intervals. Such sources are, for example, those commercialised by Insight, which are electrically tunable and akinetic. These Insight sources use a calibration procedure to skip frequencies already included in a spectral sweep, i.e., a process of “clearing the spectrum”. For the first time, the suitability of the Master–Slave (MS) procedure is evaluated as an alternative to the conventional calibration procedure for such sources. Here, the MS process is applied to the intact, raw interferogram spectrum delivered by an optical coherence tomography (OCT) system. Two modalities are investigated to implement the MS processing, based on (i) digital generation of the Master signals using the OCT interferometer and (ii) down-conversion using a second interferometer driven by the same swept source. The latter allows near-coherence-limited operation at a large axial range (>80 mm), without the need for a high sampling rate digitiser card to cope with the large frequency spectrum generated, which can exceed several GHz. In both cases, the depth information is recovered with some limitations as described in the text.


  • Sub-surface characterisation of latest-generation identification documents using optical coherence tomography

    by Manuel J. Marques, Robert Green, Roberto King, Simon Clement, Peter Hallett, Adrian Podoleanu