RKRitesh Kalaskar

Ritesh Kalaskar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ritesh Kalaskar has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Evaluation of the Efficacy of Two Different Rotary Files on Root Canal Obturation Quality, Postoperative Pain, and Instrumentation Time in Primary Molars: A Randomized Controlled Trial

    by Shivani V Sawant, Ritesh Kalaskar

    This study aimed to evaluate and compare the efficacy of ProAF Baby Gold and Prime Pedo rotary files for root canal preparation in primary maxillary and mandibular second molars. Children aged 4-7 years with primary molars requiring pulpectomy were included in the study. A total of 58 participants were randomly allocated into two groups of 29 each: group I (n = 29)—ProAF Baby Gold files and group II (n = 29)—Prime Pedo files. The mean instrumentation time for canal preparation was 153.76 seconds in group I and 189.17 seconds in group II. The ProAF Baby Gold files group required less time for biomechanical preparation compared to the Prime Pedo files. The mean pain score in group I system was 0.48 when compared to 0.83 in group II. Radiographic evaluation of obturation quality showed that 17 samples in group I were optimally filled, compared to 16 samples in group II. The obturation quality and postoperative pain between the two groups were compared using the Chi-squared test, which showed no statistically significant difference (p > 0.05) between the two rotary file systems. This study showed better quality of obturation, reduction in instrumentation time, and reduced postoperative pain with the use of the rotary file systems. Behavior management is a critical aspect of pediatric dentistry. With a reduction in the time required for treatment, behavior management may become easier for pediatric dentists. Sawant S, Kalaskar R. Comparative Evaluation of the Efficacy of Two Different Rotary Files on Root Canal Obturation Quality, Postoperative Pain, and Instrumentation Time in Primary Molars: A Randomized Controlled Trial. Int J Clin Pediatr Dent 2025;18(S-1):S1-S5.


  • Open Access

    Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis

    by Ritesh R Kalaskar, Utkarsha S Kadam, Nidhi Sharma, Snehal D Jagtap

    Restoring grossly destructed primary molars requires esthetic and durable materials that can withstand masticatory forces. Although preformed zirconia crowns are strong and durable, they require extensive tooth preparation and are brittle. The three-dimensional (3D)-printed resin NextDent crowns are nonbrittle and offer better or similar esthetic alternatives, but their ability to withstand intraoral stresses remains untested. Therefore, a 3D finite element analysis (FEA) study was planned to compare the stress distribution on primary molars restored with custom-made 3D-printed resin NextDent crowns and preformed zirconia crowns. The study design employed two finite element models, with the endodontically restored primary mandibular second molar—one restored with a 3D-printed resin NextDent crown and the other with a preformed zirconia crown. The finite element models were exported to ANSYS software and subjected to a maximum load of 500 N. The von Mises stress distribution analysis shows that the 3D-printed resin NextDent crown exhibits a higher maximum stress of 383.2 MPa on the crown, compared to 351.12 MPa for the zirconia crown. The 3D-printed resin NextDent crown can be used as an alternative to prefabricated zirconia crown for full coronal restoration of primary teeth. 3D-printed resin crowns offer high esthetic value with precise customization, require minimal tooth preparation, and are cost-effective, making them a practical and accessible option for full coronal restoration in pediatric patients. Kalaskar RR, Kadam US, Sharma N, et al. Stress Distribution Pattern of a Calculated Standardized Force on Primary Second Molar Restored with 3D-printed Resin NextDent Crown and Prefabricated Zirconia Crown: A 3D Finite Element Analysis. Int J Clin Pediatr Dent 2025;18(S-1):S35–S39.


  • Open Access

    Comparative evaluation of qualitative and quantitative wear of 3D-printing materials and zirconia against primary tooth enamel: An in vitro study

    by Ritesh Kalaskar, Nidhi Sharma, Utkarsha Kadam, Snehal Jagtap

    Aim: This study aimed to address the gap in existing literature by evaluating the qualitative and quantitative wear of two three-dimensional (3D) printing materials against primary tooth enamel, in comparison with zirconia, a widely used esthetic crown material. Methods: Eighteen extracted primary canines were used as antagonists, and six blocks each of two 3D printing resins (Shining 3D and NextDent) and zirconia were fabricated. Wear testing was performed using a reciprocating tribometer under a 40 N load at 1.5 Hz with a 4 mm stroke length for 60,000 cycles. Pre- and post-test digital scans were analyzed in Geomagic Software using a superimposition technique to calculate volumetric wear, and surface changes were examined using scanning electron microscopy. Statistical analysis was conducted using one-way ANOVA for quantitative comparison. Results: Shining 3D demonstrated the greatest material wear (0.51 mm³), followed by NextDent (0.27 mm³), while zirconia exhibited the least (0.13 mm³). Conversely, zirconia caused the highest antagonist wear (0.25 mm³), followed by NextDent (0.17 mm³) and Shining 3D (0.12 mm³), although these differences were not statistically significant. Distinct wear patterns were observed for each material. Conclusions: Within the limitations of this in vitro study, NextDent exhibited greater wear resistance than Shining 3D. Both 3D-printing resins produced less antagonist enamel wear than zirconia, underscoring their potential as promising alternatives in pediatric restorative dentistry. Further studies employing diverse materials and standardized protocols are required to validate these findings and enhance clinical translation.

  • Stress Distribution in Proclined Anterior Teeth of Pediatric Patients With and Without Mouthguard Use: A 3D Finite Element Analysis

    by Shivani Nagnath Bhadule, Ritesh R. Kalaskar, Avani Doiphode

    Background: Traumatic dental injuries related to sports are a significant concern, as they can have severe physical and psychological impacts on children. Using mouthguards is essential, particularly in sports like skating, where high‐impact forces are common.Aim: The study aimed to evaluate how stress is distributed on the teeth and surrounding bone in children with proclined anterior teeth when a force of 614.12 N was applied to two different regions of the jaws. The evaluation was conducted using finite element analysis (FEA), both with and without the use of a mouthguard.Methods and Methodology: A 3‐dimensional finite element analysis (FEA) model was constructed using a cone beam computed tomography (CBCT) scan of a 12‐year‐old male patient. An average standardized force of 614.12 N was calculated, based on the average weight of children aged 11 to 13 years and the average speed of 13.4 m/s with which the children skate. The force was applied in two different directions and areas of the jaws: a lateral blow, perpendicular to the crown and root with the maxillary and mandibular teeth in occlusion (between the first molar and second premolar), and a blow obliquely at the pogonion point on the chin. Static simulations were then performed for four realistic scenarios—two with mouthguards and two without mouthguards.Result: The Von Mises stresses were evaluated under all conditions. When the applied force was directed laterally, the stress values observed were 126.76 MPa with a mouthguard and 140 MPa without a mouthguard. When the force was applied to the chin region, the stress values were 37.997 MPa with a mouthguard and 40.67 MPa without a mouthguard.Conclusion: The use of a mouthguard in children is beneficial for protecting teeth and surrounding structures, especially in cases of proclined anterior teeth, as it helps dampen the generated stresses.


  • Open Access

    Clinical and Radiographic Efficacy of Low-level Laser Therapy and Formocresol as Pulpotomy Agents in Primary Molars: A Systematic Review and Meta-analysis

    by Ritesh Kalaskar, Ashita Kalaskar, Urvi P Gala, Nilam V Honaje, Avani R Doiphode

    To evaluate the effectiveness of low-level laser therapy (LLLT) as a pulpotomy agent in primary molars. This systematic review followed the recommendation of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline 2020. An electronic search of the databases was performed to find the effectiveness of LLLT over formocresol as a pulpotomy agent in primary molars in children aged between 3 and 10 years. Authors independently extracted the data from the 14 included studies based on the inclusion criteria. The inclusion criteria comprised studies that compared the clinical and radiographical effectiveness of LLLT pulpotomy with formocresol pulpotomy in primary molars using randomized clinical trials (RCTs). The risk of bias was assessed using a tool developed by the Cochrane Collaboration for RCT studies. The meta-analyses were performed using the fixed-effects model. Heterogeneity was assessed by a Q test and quantified with I2 statistics. Radiological and clinical success among the teeth treated with either formocresol or LLLT was considered the main outcome. The search resulted in 390 published studies. After the removal of duplicate studies and analysis of full-text articles, 14 studies were selected for systematic review. Overall, the results demonstrated a high risk of selection and performance bias. No statistically significant difference was found between LLLT and formocresol as pulpotomy agents when compared clinically and radiographically at 6–9 and 12-month follow-up periods. LLLT is a good alternative method to be used as a pulpotomy agent in cases of reversible pulpitis. Low-level laser therapy is an emerging and trending branch in dentistry because of its beneficial effects in various treatment approaches. It can be effectively used in the pulpotomy procedure due to its properties to reduce pulp inflammation, improve healing, and preserve dental pulp vitality. Doiphode AR, Kalaskar R, Kalaskar A, et al. Clinical and Radiographic Efficacy of Low-level Laser Therapy and Formocresol as Pulpotomy Agents in Primary Molars: A Systematic Review and Meta-analysis. Int J Clin Pediatr Dent 2024;17(9):1075–1085.


  • Open Access

    Comparative Evaluation of Effectiveness of Rotary and Hand File Systems in Terms of Quality of Obturation and Instrumentation Time among Primary Teeth: A Systematic Review and Meta-analysis of Randomized Controlled Trials

    by Ritesh Kalaskar, Vineet Vinay, Urvi P Gala, Suyash Joshi, Avani R Doiphode

    This systematic review and meta-analysis aimed to answer the following focused question: Are rotary file systems more effective than hand file systems in terms of the quality of obturation and instrumentation time among primary teeth? The inclusion criteria comprised studies that compared the effect on quality of obturation and instrumentation time among primary teeth after using rotary and hand file systems for biomechanical preparation of the root canals. This review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. The searched databases included Medline (via PubMed), EBSCO, and Google Scholar. Articles published from January 2000 to December 2021, but only in English, were included. The search resulted in 8,003 published studies. After the removal of duplicate studies and full-text analysis, 9 studies were selected for systematic review, and 8 were selected for meta-analysis. Overall, the results demonstrated the promising effects of rotary file systems in reducing instrumentation time and improving obturation quality compared to hand files. Within the limitations of this review, it can be asserted that rotary file systems are superior to hand files in primary teeth for pulpectomy procedures. Rotary files, a more recent technique, are more efficient than traditional hand files in lowering the time required for instrumentation. Additionally, they provide superior obturation quality in primary molars, making them particularly beneficial for pediatric patients. Gala UP, Kalaskar R, Vinay V, et al. Comparative Evaluation of Effectiveness of Rotary and Hand File Systems in Terms of Quality of Obturation and Instrumentation Time among Primary Teeth: A Systematic Review and Meta-analysis of Randomized Controlled Trials. Int J Clin Pediatr Dent 2024;17(8):962–969.


  • Open Access

    Stress Distribution Pattern of a Calculated Standardized Force on Maxillary and Mandibular Jaws with Proclined Maxillary Anterior Teeth with and without the Use of Mouthguard: A 3D Finite Element Analysis

    by Ritesh Kalaskar, Avani R Doiphode

    To evaluate the stress distribution of calculated standardized force on maxillary and mandibular jaw bones with proclined maxillary anterior teeth with and without the use of a mouthguard. It's a finite element analysis (FEA) study. Maxillary and mandibular jaw models with and without mouthguard (4 mm) were created using a cone-beam computed tomography (CBCT) scan of a 13-year-old male patient with proclined maxillary anterior teeth. Calculated standardized forces were applied on the maxillary central incisors in the horizontal direction of the created model. The von Mises stresses (MPa) were analyzed on the maxillary and mandibular jaw. Higher von Mises stresses were analyzed in the maxillary and mandibular jaw model without a mouthguard compared to the model with a mouthguard. Forces were more evenly distributed in the maxillary and mandibular jaw models with a mouthguard. A mouthguard can be used to reduce and evenly distribute the stress on the maxillary and mandibular jaw with proclined maxillary anterior teeth when exposed to real-life situation forces. The force of injury is influenced by the size of the object or the velocity at which the athlete hits the object/individual. There is a need to evaluate the force at which the individual athlete hits the object/surface based on average height, weight, and velocity/performance at that particular age. As the age of the athlete's advances, there is a change in the height, weight as well as performance. This factor will influence the impact and severity of the trauma caused during sports activities. So, these parameters should be considered while designing the mouthguard for its better effectiveness. Doiphode AR, Kalaskar R. Stress Distribution Pattern of a Calculated Standardized Force on Maxillary and Mandibular Jaws with Proclined Maxillary Anterior Teeth with and without the Use of Mouthguard: A 3D Finite Element Analysis. Int J Clin Pediatr Dent 2024;17(S-1):S61–S66.


  • Open Access

    Clinical Effectiveness of Air Abrasion When Compared to Conventional Acid-etching Technique in Enhancing the Retention of Pit and Fissure Sealants: A Systematic Review

    by Ritesh Kalaskar, Ashita Kalaskar, Shruti Balasubramanian, Karthika Krishnakumar, Suyash Joshi, Shivani N Bhadule

    The purpose of our study was to perform a systematic review to assess and compare the effectiveness of the air abrasion technique with that of the conventional acid-etching technique performed before the placement of pit and fissure sealants. A search of studies was conducted in May 2021 using PubMed, Cochrane Library, and Google Scholar databases. Clinical trials in the English language between 1997 and 2019 were included. The quality of the studies was analyzed using the Cochrane Collaboration tool. The search retrieved 276 references, out of which seven studies were included for a qualitative analysis. In these seven studies, the risk of bias across the Cochrane tool's domains varied from low to high. All the included studies considered acid-etching as a comparator to air abrasion technique either used alone or as an adjunct to acid-etching technique. When coverage of sealants or their retentivity was compared at different time intervals, it was more in the acid-etching group than in the air abrasion group. Similarly, carious lesions were seen more in the air abrasion group than in the acid-etching group. The air abrasion technique followed by acid-etching brought superior retention properties of sealants than the acid-etching technique alone. Bhadule SN, Kalaskar R, Kalaskar A, et al. Clinical Effectiveness of Air Abrasion When Compared to Conventional Acid-etching Technique in Enhancing the Retention of Pit and Fissure Sealants: A Systematic Review. Int J Clin Pediatr Dent 2024;17(3):377–384.


  • Open Access

    Clinical Effectiveness of High-viscosity Glass Ionomer Cement and Composite Resin as a Restorative Material in Primary Teeth: A Systematic Review of Clinical Trials

    by Ritesh Kalaskar, Ashita Kalaskar, Karthika Krishnakumar, Shivani Bhadule, Suyash Joshi

    This systematic review was designed to compare the clinical effectiveness of high-viscosity glass ionomer cement (HVGIC) restorations to direct composite resin (CR) restorations in single- or multisurface cavities in primary teeth. Restorative procedures are typically used to treat caries in primary teeth. Due to their improved preservation of the natural tooth structure and their adhesion to the remaining tooth structure, CR and GIC have drawn attention as the preferred restorative materials. In the literature, over the past 20 years, the term HVGIC has developed. Compared to C-GICs, HVGICs appear to have a higher survival rate. However, isolated studies provide contradictory findings regarding the durability of restorations in primary teeth. Major electronic databases were thoroughly searched to find publications from the years 2000 to 2021. Studies included were randomized and nonrandomized clinical trials on children aged 3–13 years, in which restoration of primary teeth using HVGIC and CR was performed. This systematic review includes four studies [three randomized controlled trials (RCTs) and one nonrandomized controlled trial]. No statistically significant difference between these materials was seen in any of the included studies. This systematic review of findings supports the assertion that both HVGIC and CR restorations deliver satisfactory outcomes in terms of clinical efficacy and overall survivability. It was found that, for both materials, class I restorations had statistically higher survival rates than class II restorations. Long-term studies are essential to evaluate the clinical efficacy of both restorations. This systematic review outlines the application of HVGIC and CR as restorative materials for pediatric dentists to use in their everyday dental practices. Krishnakumar K, Kalaskar R, Kalaskar A, et al. Clinical Effectiveness of High-viscosity Glass Ionomer Cement and Composite Resin as a Restorative Material in Primary Teeth: A Systematic Review of Clinical Trials. Int J Clin Pediatr Dent 2024;17(2):221–228.


  • Open Access

    Comparative Evaluation of the Effectiveness of Innovative Periorbital Eye Massager and Virtual Reality Eyeglasses for Reducing Dental Anxiety during Dental Restorative Procedures in Children

    by Ritesh Kalaskar, Urvi P Gala

    Many behavior management techniques are employed to reduce the anxiety associated with dental procedures in children. One of the most commonly used methods comprises audiovisual distraction using virtual reality (VR) eyeglasses. In this study, an innovative device, a periorbital eye massager (PEM), is compared with VR to evaluate dental anxiety in children. in this study, 22 children were divided into two groups, that is, group I consisting of PEM and group II consisting of VR. The participants were instructed to wear the device and then subjected to dental restorative procedures. After completion of the procedure, anxiety was measured using a validated questionnaire by the children and by using the modified behavior pain scale by the second investigator. Also, physiological parameters like heart rate and oxygen saturation were evaluated before and after a dental procedure. The results were statistically insignificant for group I and group II when a validated questionnaire and modified behavior pain scale were used to measure the dental anxiety of children. Also, the data also shows no significant difference in heart rate and oxygen saturation between the two groups. The innovative PEM can also be used as an effective behavior management tool in managing dental anxiety in children, as there was no statistically significant difference between PEM and VR. As a pediatric dentist, the methods for administering a patient present a novel challenge because behavior management varies from patient to patient. As a result, the prospects for augmenting various techniques of behavior therapy for pediatric patients are limitless. Gala UP, Kalaskar R. Comparative Evaluation of the Effectiveness of Innovative Periorbital Eye Massager and Virtual Reality Eyeglasses for Reducing Dental Anxiety during Dental Restorative Procedures in Children. Int J Clin Pediatr Dent 2024;17(1):48–53.