Sevan Harput
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sevan Harput has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
- Steven Freear
University of Leeds
47 shared publications David M. J. Cowell
Ultrasonics and Instrumentation Group, School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K.
18 shared publications- Kirsten Christensen-Jeffries
King’s College London,Biomedical Engineering Department,London,UK,SE1 7EH
17 shared publications Jemma Brown
School of Biomedical Engineering and Imaging Sciences, Kings College London,Biomedical Engineering Department,London,UK,SE1 7EH
14 shared publications- Meng-Xing Tang
Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
14 shared publications James McLaughlan
Ultrasonics and Instrumentation Group, School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, United Kingdom
13 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by Elsevier in SSRN Electronic Journal
Acoustic Based Damage Detection Using ZnO Sensors: A Machine Learning Approach For Structural Damage Detection Employing Ambient Vibrations
The use of an acoustic signature in the form of an input mechanical vibration has been the basis for a wide range of structural health monitoring approaches. It is typical for vibration-based analytical methods to identify damage by interpreting changes in modal parameters detected as a variation from a pre-defined input signature. Here, a piezoelectric bi-morph sensor is introduced that utilizes the inherent acoustic signature of a vibrating system as the input signal for continuous real-time analysis of changes to the structure. The sensor exhibits a flat quality factor from 10 to 1200 Hz, ensuring reliable performance across a wide frequency range. Machine learning is employed to produce an understanding of the undamaged conditions and monitor changes to the acoustic environment to enable damage identification. Experimental validation on test steel beam demonstrated that the system detected surface damage below 1 mm of cut and the damage detection ability was tested across a range of distances from the sensor’s location. A Support Vector Machine (SVM) model achieved 91.7% accuracy in detecting sub-millimetre damage using the inherent system borne vibrational patterns. By combining the flat quality response of a piezoelectric sensor with machine learning driven classification based on changes in acoustic environment, a continuous, real-time, scalable, high fidelity damage detection solution has been provided for vibrating infrastructure applications.
- 12 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAcoustic Based Damage Detection Using ZnO Sensors: A Machine Learning Approach For Structural Damage Detection Employing Ambient Vibrations
The use of an acoustic signature in the form of an input mechanical vibration has been the basis for a wide range of structural health monitoring approaches. It is typical for vibration-based analytical methods to identify damage by interpreting changes in modal parameters detected as a variation from a pre-defined input signature. Here, a piezoelectric bi-morph sensor is introduced that utilizes the inherent acoustic signature of a vibrating system as the input signal for continuous real-time analysis of changes to the structure. The sensor exhibits a flat quality factor from 10 to 1200 Hz, ensuring reliable performance across a wide frequency range. Machine learning is employed to produce an understanding of the undamaged conditions and monitor changes to the acoustic environment to enable damage identification. Experimental validation on test steel beam demonstrated that the system detected surface damage below 1 mm of cut and the damage detection ability was tested across a range of distances from the sensor’s location. A Support Vector Machine (SVM) model achieved 91.7% accuracy in detecting sub-millimetre damage using the inherent system borne vibrational patterns. By combining the flat quality response of a piezoelectric sensor with machine learning driven classification based on changes in acoustic environment, a continuous, real-time, scalable, high fidelity damage detection solution has been provided for vibrating infrastructure applications.
- 6 July 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (1)
Microwave-induced activation of phase-change nanodroplets using a directional ultrawideband microstrip antenna
- 6 July 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (1)
Microwave-induced activation of phase-change nanodroplets using a directional ultrawideband microstrip antenna
- Open Access
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Stress imaging arthrometry for assessing anterior talofibular ligament strain in-vivo
Lateral ankle sprain is the most common musculoskeletal injury that happens as a result of excessive ankle joint supination and typically involves trauma to the anterior talofibular ligament (ATFL) due to over-elongation and exceeding its ultimate strain threshold. The purpose of this study is to present a novel in-vivo method for assessing ATFL strain within and beyond the normal kinematic range of ankle joint inversion. In addition, sex differences are investigated. The feet of 54 healthy participants (28f/26m; 18 to 40yrs) were fixated within a custom-made arthrometer and the ankle joint was passively rotated from 0° (neutral) to inversion angles of 5°, 10° and 20°. Electromyographic activity of the peroneus longus muscle was monitored to ensure passive ankle joint rotation. At each angle, ATFL length was imaged via B-mode ultrasound and calculated as the curved path between its enthesis points. Deformation was calculated relative to neutral position and expressed as strain (%). Both ATFL length and strain significantly increased with increasing ankle inversion (p<0.001) up to 20.9 mm and 7.8% at 20°, respectively. The ligament was significantly longer in males (20.0 vs 21.8 mm; p<0.01) but no sex differences in strain were evident across all angles. These findings support the notion that high ankle joint inversion places a substantial mechanical demand on the ATFL and suggest that stress imaging arthrometry could be a valuable tool for the early detection of ligament overuse injuries and objective assessment of rehabilitation effectiveness.
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStress imaging arthrometry for assessing anterior talofibular ligament strain in-vivo
Lateral ankle sprain is the most common musculoskeletal injury that happens as a result of excessive ankle joint supination and typically involves trauma to the anterior talofibular ligament (ATFL) due to over-elongation and exceeding its ultimate strain threshold. The purpose of this study is to present a novel in-vivo method for assessing ATFL strain within and beyond the normal kinematic range of ankle joint inversion. In addition, sex differences are investigated. The feet of 54 healthy participants (28f/26m; 18 to 40yrs) were fixated within a custom-made arthrometer and the ankle joint was passively rotated from 0° (neutral) to inversion angles of 5°, 10° and 20°. Electromyographic activity of the peroneus longus muscle was monitored to ensure passive ankle joint rotation. At each angle, ATFL length was imaged via B-mode ultrasound and calculated as the curved path between its enthesis points. Deformation was calculated relative to neutral position and expressed as strain (%). Both ATFL length and strain significantly increased with increasing ankle inversion (p<0.001) up to 20.9 mm and 7.8% at 20°, respectively. The ligament was significantly longer in males (20.0 vs 21.8 mm; p<0.01) but no sex differences in strain were evident across all angles. These findings support the notion that high ankle joint inversion places a substantial mechanical demand on the ATFL and suggest that stress imaging arthrometry could be a valuable tool for the early detection of ligament overuse injuries and objective assessment of rehabilitation effectiveness.
- Open Access
- 23 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 78148-78160
A Consensus Mechanism to Improve Prediction of Cortical Bone Properties Using Ultrafast Ultrasound Acquisition
Human bone microarchitecture is complex and density-based bone assessment modalities cannot fully capture bone strength or health. Ultrasound can be used to assess bone microstructure, but it is hindered by the dense and acoustically diverse nature of cortical bone. This study proposes a methodology for predicting cortical bone thickness and porosity through a novel approach utilizing convolutional neural networks (CNNs), processing multi-frequency radiofrequency (RF) data obtained from ultrafast ultrasound, and implementing a consensus mechanism to enhance accuracy. Received ultrasound RF signals are processed using a CNN with a mutual consensus mechanism, which is used to discard received RF data when measurement variation is over a certain threshold. The feasibility of the proposed method is demonstrated through realistic simulations and an ex vivo animal bone study using an ultrafast ultrasound scanner. The preliminary findings of this study demonstrate an enhancement in overall accuracy, with an increase from 92% to 95.6% for thickness and an increase from 73.4% to 88.4% for porosity classification, without and with consensus respectively. The implemented mutual consensus mechanism increases the accuracy of the thickness and porosity estimations both in silico and ex vivo. Ultrafast ultrasound scanners can capture thousands of RF signals within seconds, which results in availability of large datasets for implementation of artificial intelligence and machine learning algorithms. Here, we propose a new approach for ultrafast ultrasound data processing that values data quality over quantity by discarding noisy ultrasound measurements using a consensus mechanism to improve the final estimation accuracy.
- 23 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 78148-78160
Open AccessA Consensus Mechanism to Improve Prediction of Cortical Bone Properties Using Ultrafast Ultrasound Acquisition
Human bone microarchitecture is complex and density-based bone assessment modalities cannot fully capture bone strength or health. Ultrasound can be used to assess bone microstructure, but it is hindered by the dense and acoustically diverse nature of cortical bone. This study proposes a methodology for predicting cortical bone thickness and porosity through a novel approach utilizing convolutional neural networks (CNNs), processing multi-frequency radiofrequency (RF) data obtained from ultrafast ultrasound, and implementing a consensus mechanism to enhance accuracy. Received ultrasound RF signals are processed using a CNN with a mutual consensus mechanism, which is used to discard received RF data when measurement variation is over a certain threshold. The feasibility of the proposed method is demonstrated through realistic simulations and an ex vivo animal bone study using an ultrafast ultrasound scanner. The preliminary findings of this study demonstrate an enhancement in overall accuracy, with an increase from 92% to 95.6% for thickness and an increase from 73.4% to 88.4% for porosity classification, without and with consensus respectively. The implemented mutual consensus mechanism increases the accuracy of the thickness and porosity estimations both in silico and ex vivo. Ultrafast ultrasound scanners can capture thousands of RF signals within seconds, which results in availability of large datasets for implementation of artificial intelligence and machine learning algorithms. Here, we propose a new approach for ultrafast ultrasound data processing that values data quality over quantity by discarding noisy ultrasound measurements using a consensus mechanism to improve the final estimation accuracy.
- Open Access
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
A human ear-inspired ultrasonic transducer (HEUT) for 3D localization of sub-wavelength scatterers
The proposed technology aims to enable 3D localization of scatterers using single element ultrasonic transducers, which are traditionally limited to 1D measurements. This is achieved by designing a bespoke acoustic lens with a spiral-shaped pattern similar to the human outer ear, a shape that has evolved for sound source localization. This lens breaks the surface symmetry of the transducer, allowing ultrasonic waves arriving from different directions to be encoded in a certain way that can later be decoded to extract directional information. By employing the mechanism of spatial-encoding of the received signals and decoding via signal processing, the location of sub-wavelength scatterers can be detected in 3D with a single measurement for sparsely distributed scatterers. The proposed technology is first verified through a simulation study, and then 3D printed acoustic lenses are used to demonstrate the 3D encoding functionality of the Human Ear-inspired Ultrasonic Transducer (HEUT) experimentally. A framework is created to localize scatterers in 3D by processing received signals acquired by a HEUT prototype. With this technology, a single transducer can obtain multi-dimensional information with a single pulse-echo measurement, reducing the number of elements required for performing 3D ultrasound localization. The proposed spatial-encoding and -decoding technology can be applied to other wave-based imaging methods to develop affordable, practical, and compact sensing devices.
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
Open AccessA human ear-inspired ultrasonic transducer (HEUT) for 3D localization of sub-wavelength scatterers
The proposed technology aims to enable 3D localization of scatterers using single element ultrasonic transducers, which are traditionally limited to 1D measurements. This is achieved by designing a bespoke acoustic lens with a spiral-shaped pattern similar to the human outer ear, a shape that has evolved for sound source localization. This lens breaks the surface symmetry of the transducer, allowing ultrasonic waves arriving from different directions to be encoded in a certain way that can later be decoded to extract directional information. By employing the mechanism of spatial-encoding of the received signals and decoding via signal processing, the location of sub-wavelength scatterers can be detected in 3D with a single measurement for sparsely distributed scatterers. The proposed technology is first verified through a simulation study, and then 3D printed acoustic lenses are used to demonstrate the 3D encoding functionality of the Human Ear-inspired Ultrasonic Transducer (HEUT) experimentally. A framework is created to localize scatterers in 3D by processing received signals acquired by a HEUT prototype. With this technology, a single transducer can obtain multi-dimensional information with a single pulse-echo measurement, reducing the number of elements required for performing 3D ultrasound localization. The proposed spatial-encoding and -decoding technology can be applied to other wave-based imaging methods to develop affordable, practical, and compact sensing devices.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2118-2121
Super-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error
Localization-based super-resolution imaging requires accurate detection of spatially isolated microbubbles. The reason for this requirement is that interfering or overlapping signals resulting from multiple microbubbles within the resolution limit can cause position errors. In addition to this, noise and artefacts (e.g. residual tissue signal after tissue-microbubble separation) further reduce the quality and hence the spatial resolution in SR imaging. Therefore, correctly identifying the echoes as noise, single microbubble, multiple microbubbles, or artefact is important.In this study, the use of fast classification methods for identification and rejection of non-single microbubble echoes were demonstrated. Most commonly used supervised classification methods, including Decision Trees, Discriminant Analysis, Logistic Regression, Support Vector Machine, Ensembles, k-Nearest Neighbors, and Naive Bayes, were implemented for filtering artefacts and noise in super-resolution ultrasound images. Results showed that the Ensemble method, explicitly designed to deal with unbalanced data, achieved the best result since most of the localized events are true microbubbles, which is typical for super-resolution imaging datasets.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2118-2121
Open AccessSuper-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error
Localization-based super-resolution imaging requires accurate detection of spatially isolated microbubbles. The reason for this requirement is that interfering or overlapping signals resulting from multiple microbubbles within the resolution limit can cause position errors. In addition to this, noise and artefacts (e.g. residual tissue signal after tissue-microbubble separation) further reduce the quality and hence the spatial resolution in SR imaging. Therefore, correctly identifying the echoes as noise, single microbubble, multiple microbubbles, or artefact is important.In this study, the use of fast classification methods for identification and rejection of non-single microbubble echoes were demonstrated. Most commonly used supervised classification methods, including Decision Trees, Discriminant Analysis, Logistic Regression, Support Vector Machine, Ensembles, k-Nearest Neighbors, and Naive Bayes, were implemented for filtering artefacts and noise in super-resolution ultrasound images. Results showed that the Ensemble method, explicitly designed to deal with unbalanced data, achieved the best result since most of the localized events are true microbubbles, which is typical for super-resolution imaging datasets.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 372-375
Minimization of Nanodroplet Activation Time using Focused-Pulses for Droplet-Based Ultrasound Super-Resolution Imaging
One of the crucial challenges in the application of ultrasound super-resolution imaging using microbubble contrast agents to the clinic is the long acquisition time. Recently acoustic wave sparsely activated localization microscopy (AWSALM) was developed to activate, image, and destroy nanodroplets to achieve ultrasound super-resolution imaging. The activation and destruction of nanodroplets using focused pulses in AWSALM can generate new localization signals without relying on flow and shows the potential to achieve faster ultrasound super-resolution. However, the technique requires optimization to achieve good activation efficiency with the minimum amount of activation time.This work investigates how the different activation strategies affect the activation time and efficiency. A range of activation sequences with different F-numbers and spacing between transmit foci are used and their activation efficiency and the data acquisition time are quantified. The results show that sweeping the focus of the activation pulse with an F-number of 0.4 and a step size of 2.5 wavelengths can generate the highest droplet activation. By using a larger or smaller spacing between consecutive focused activation beams generated lower contrast, which suggests that densely spaced activation pulses may destroy the activated nanodroplets generated by the previous activation pulse. In summary, this study demonstrates that the rate of activation of nanodroplets can be increased by optimizing the F-number and the sweep step size. This finding can inform the development of droplet-based super-resolution imaging to further minimize the data acquisition time.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 372-375
Open AccessMinimization of Nanodroplet Activation Time using Focused-Pulses for Droplet-Based Ultrasound Super-Resolution Imaging
One of the crucial challenges in the application of ultrasound super-resolution imaging using microbubble contrast agents to the clinic is the long acquisition time. Recently acoustic wave sparsely activated localization microscopy (AWSALM) was developed to activate, image, and destroy nanodroplets to achieve ultrasound super-resolution imaging. The activation and destruction of nanodroplets using focused pulses in AWSALM can generate new localization signals without relying on flow and shows the potential to achieve faster ultrasound super-resolution. However, the technique requires optimization to achieve good activation efficiency with the minimum amount of activation time.This work investigates how the different activation strategies affect the activation time and efficiency. A range of activation sequences with different F-numbers and spacing between transmit foci are used and their activation efficiency and the data acquisition time are quantified. The results show that sweeping the focus of the activation pulse with an F-number of 0.4 and a step size of 2.5 wavelengths can generate the highest droplet activation. By using a larger or smaller spacing between consecutive focused activation beams generated lower contrast, which suggests that densely spaced activation pulses may destroy the activated nanodroplets generated by the previous activation pulse. In summary, this study demonstrates that the rate of activation of nanodroplets can be increased by optimizing the F-number and the sweep step size. This finding can inform the development of droplet-based super-resolution imaging to further minimize the data acquisition time.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1930-1933
Acoustic Wave Sparsely-Activated Localization Microscopy (AWSALM): In Vivo Fast Ultrasound Super-Resolution Imaging using Nanodroplets
Current localization-based super-resolution ultrasound imaging requires a low concentration of flowing microbubbles to visualize microvasculature beyond the diffraction limit and acquisition is slow. Nanodroplets offer a promising solution as they can be sparsely activated and deactivated on-demand. In this study, acoustic wave sparsely-activated localization microscopy (AWSALM) using activation and deactivation of nanodroplets, an acoustic counterpart of photo-activated localization microscopy (PALM) which is less dependent on agent concentration and the presence of flow, is demonstrated for super-resolution imaging in deep tissues in vivo. An in vivo super-resolution image of a rabbit kidney is obtained in 1.1 seconds using AWSALM, where micro-vessels with apparent sizes far below the half-wavelength of 220 µm were visualized. This preliminary result demonstrates the feasibility of applying AWSALM for in vivo super-resolution imaging.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1930-1933
Acoustic Wave Sparsely-Activated Localization Microscopy (AWSALM): In Vivo Fast Ultrasound Super-Resolution Imaging using Nanodroplets
Current localization-based super-resolution ultrasound imaging requires a low concentration of flowing microbubbles to visualize microvasculature beyond the diffraction limit and acquisition is slow. Nanodroplets offer a promising solution as they can be sparsely activated and deactivated on-demand. In this study, acoustic wave sparsely-activated localization microscopy (AWSALM) using activation and deactivation of nanodroplets, an acoustic counterpart of photo-activated localization microscopy (PALM) which is less dependent on agent concentration and the presence of flow, is demonstrated for super-resolution imaging in deep tissues in vivo. An in vivo super-resolution image of a rabbit kidney is obtained in 1.1 seconds using AWSALM, where micro-vessels with apparent sizes far below the half-wavelength of 220 µm were visualized. This preliminary result demonstrates the feasibility of applying AWSALM for in vivo super-resolution imaging.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2275-2278
Activation and 3D Imaging of Phase-change Nanodroplet Contrast Agents with a 2D Ultrasound Probe
Nanodroplets are on-demand ultrasound contrast agents. They can remain in circulation longer in vivo than mi-crobubbles and can be spatiotemporally and selectively activated to provide contrast when required. Perfluorocarbon nanodroplets have been used for conventional 2D ultrasound imaging and different types of nanodroplets have been studied and characterized by researchers regarding their suitability for imaging. However, the use of nanodroplets for 3D imaging and their activation using a 2D ultrasound probe has not been reported. In this study, we investigate the nanodroplet activation using a 2D ultrasound imaging probe within clinical safety limits.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2275-2278
Activation and 3D Imaging of Phase-change Nanodroplet Contrast Agents with a 2D Ultrasound Probe
Nanodroplets are on-demand ultrasound contrast agents. They can remain in circulation longer in vivo than mi-crobubbles and can be spatiotemporally and selectively activated to provide contrast when required. Perfluorocarbon nanodroplets have been used for conventional 2D ultrasound imaging and different types of nanodroplets have been studied and characterized by researchers regarding their suitability for imaging. However, the use of nanodroplets for 3D imaging and their activation using a 2D ultrasound probe has not been reported. In this study, we investigate the nanodroplet activation using a 2D ultrasound imaging probe within clinical safety limits.
- Open Access
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 269-277
3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 269-277
Open Access3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.