WSWen-Pin Shih

Wen-Pin Shih

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wen-Pin Shih has a total of 240 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Photo-controllable contact angle hysteresis on an artificial Azo-IPN petal

    by Cheng-Hsi Weng, Cheng-Chuan Lin, Fu-Cheng Tsai, Chi-An Dai, Fu-Ling Yang, Wen-Pin Shih, Pei-Zen Chang


  • Color rendering based on a plasmon fullerene cavity

    by Fu-Cheng Tsai, Cheng-Hsi Weng, Yu Lim Chen, Wen-Pin Shih, Pei-Zen Chang

    Fullerene in the plasmon fullerene cavity is utilized to propagate plasmon energy in order to break the confinement of the plasmonic coupling effect, which relies on the influential near-field optical region. It acts as a plasmonic inductor for coupling gold nano-islands to the gold film; the separation distances of the upper and lower layers are longer than conventional plasmonic cavities. This coupling effect causes the discrete and continuum states to cooperate together in a cavity and produces asymmetric curve lines in the spectra, producing a hybridized resonance. The effect brings about a bright and saturated displaying film with abundant visible colors. In addition, the reflection spectrum is nearly omnidirectional, shifting by only 5% even when the incident angle changes beyond ± 60°. These advantages allow plasmon fullerene cavities to be applied to reflectors, color filters, visible chromatic sensors, and large-area display.


  • Open Access

    Estimation of the Corneal Young’s ModulusIn VivoBased on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging

    by Po-Jen Shih, Chun-Ju Huang, Tzu-Han Huang, Hung-Chou Lin, Jia-Yush Yen, I-Jong Wang, Hui-Jyun Cao, Wen-Pin Shih, Chi-An Dai

    Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOPin vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young’s modulus from the patient data. This Young’s modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young’s modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young’s modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffnessin vivofor ophthalmologists’ reference in diagnosis.


  • Open Access

    Fall Prevention Shoes Using Camera-Based Line-Laser Obstacle Detection System

    by Tzung-Han Lin, Chi-Yun Yang, Wen-Pin Shih

    Fall prevention is an important issue particularly for the elderly. This paper proposes a camera-based line-laser obstacle detection system to prevent falls in the indoor environment. When obstacles are detected, the system will emit alarm messages to catch the attention of the user. Because the elderly spend a lot of their time at home, the proposed line-laser obstacle detection system is designed mainly for indoor applications. Our obstacle detection system casts a laser line, which passes through a horizontal plane and has a specific height to the ground. A camera, whose optical axis has a specific inclined angle to the plane, will observe the laser pattern to obtain the potential obstacles. Based on this configuration, the distance between the obstacles and the system can be further determined by a perspective transformation called homography. After conducting the experiments, critical parameters of the algorithms can be determined, and the detected obstacles can be classified into different levels of danger, causing the system to send different alarm messages.


  • Ultra-large suspended graphene as a highly elastic membrane for capacitive pressure sensors

    by Yu-Min Chen, Shih-Ming He, Chi-Hsien Huang, Cheng-Chun Huang, Wen-Pin Shih, Chun-Lin Chu, Jing Kong, Ju Li, Ching-Yuan Su

    We prepared ultra-large suspended graphene membranes (up to 1.5 mm) through solvent replacement, followed by thermal decomposition. A capacitive pressure sensor was fabricated, which showed a linear response and high sensitivity of 15.15 aF Pa−1.


  • Porous reduced graphene oxide membrane with enhanced gauge factor

    by Jen-Chieh Li, Cheng-Hsi Weng, Fu-Cheng Tsai, Wen-Pin Shih, Pei-Zen Chang

    This paper shows that a porous structure for a reduced graphene oxide (rGO) membrane effectively enhances its gauge factor. A porous graphene-based membrane was synthesized in a liquid phase by combining a GO sheet with copper hydroxide nanostrands (CHNs). A chemical reduction treatment using L-ascorbic acid was utilized to simultaneously improve the conductivity of GO and remove the CHNs from each GO sheet. The intrinsic gauge factors of the porous rGO membrane with varying applied tensile strains were obtained and found to increase monotonically with the increased porosity of the rGO membrane. For a membrane porosity of 15.78%, the maximum gauge factor is 46.1 under an applied strain of less than 1%. The main mechanism behind the enhanced gauge factor is attributed to the structure of the porous rGO membrane. The relationships between the initial electrical resistance, tunneling distance, and gauge factor of the rGO membrane were found by adjusting the membrane porosity and the results completely confirmed the physical phenomena.


  • A corneal elastic dynamic model derived from Scheimpflug imaging technology

    by Po‐Jen Shih, Huei‐Jyun Cao, Chun‐Ju Huang, I‐Jong Wang, Wen‐Pin Shih, Jia‐Yush Yen

    Purpose: To simultaneously extract the corneal Young's modulus and the damping ratio from Scheimpflug imaging data. Methods: A spherical diaphragm model can better represent the geometry and physics of an eyeball than the popular mass‐spring‐damper model. This research derived the dynamic model of a water‐filled spherical diaphragm based on the hydrodynamics and wave propagation theories. By applying modal analysis on the model, one can decouple the cornea vibration into individual modes and reconstruct the air puff vibration from the decoupled responses. By matching this response with the Scheimpflug imaging data from the Corvis ® ST , it was then possible to extract multiple physiological properties as desired. Results: The dynamic modal analysis was employed to extract the corneal physiological properties of 25 Taiwanese normal subjects. Specifically, the corneal Young's moduli and damping ratios were estimated. In fact the model is dependent on the physiological parameters such as cornea thickness, densities, and intraocular pressure. It is thus also possible to extract these parameters through multi‐goal minimisation processes. Conclusions: The spherical diaphragm model was able to better describe the dynamic response of the eyeball. The model analysis also provides additional corneal physiological properties that were not available through other means.


  • Onion artificial muscles

    by Chien-Chun Chen, Wen-Pin Shih, Pei-Zen Chang, Hsi-Mei Lai, Shing-Yun Chang, Pin-Chun Huang, Huai-An Jeng

    Artificial muscles are soft actuators with the capability of either bending or contraction/elongation subjected to external stimulation. However, there are currently no artificial muscles that can accomplish these actions simultaneously. We found that the single layered, latticed microstructure of onion epidermal cells after acid treatment became elastic and could simultaneously stretch and bend when an electric field was applied. By modulating the magnitude of the voltage, the artificial muscle made of onion epidermal cells would deflect in opposing directions while either contracting or elongating. At voltages of 0–50 V, the artificial muscle elongated and had a maximum deflection of −30 μm; at voltages of 50–1000 V, the artificial muscle contracted and deflected 1.0 mm. The maximum force response is 20 μN at 1000 V.