DRDavid Rodbard

David Rodbard

*This is an algorithmically generated author record based on publicly available information.

David Rodbard has a total of 191 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterizing insulin dosing behaviour and glycaemic excursions: Development of metrics using connected insulin pen and continuous glucose monitoring

    by Howard Wolpert, David Rodbard, Jie Xue, Jennal Johnson, Eyal Dassau

    Aims: Connected insulin pens (CIPs) provide insulin dosing data that can be leveraged to drive improvements in glycaemic control. To realize this potential in routine care, insulin data need to be distilled into actionable insights for clinicians. We describe two algorithms for detecting glucose excursions using continuous glucose monitoring (CGM) data and then link excursions to CIP data to derive “insulin metrics” characterizing suboptimal bolus dosing practices. Materials and Methods: This post hoc analysis used CGM and CIP data from a 12‐week observational study ( clinicaltrials.gov : NCT03368807) of 64 adults with type 1 or type 2 diabetes receiving multiple daily injection insulin therapy and glycated haemoglobin ≥8%. Two updated algorithms were applied to analyse glucose excursions associated with pre‐meal boluses, missed bolus doses (MBDs), delayed boluses and correction boluses. Results: Glycaemic metrics obtained using both algorithms were similar. Time in range (%TIR) was lower, and time above range (%TAR) and glycaemic variability (%GV) were higher, on days with MBDs. Compared with pre‐meal boluses, delayed and correction boluses were followed by glucose excursions with larger change in glucose, longer duration with glucose >180 mg/dL, lower post‐excursion %TIR and higher post‐excursion %TAR; excursions following MBDs showed lower %TIR, higher %TAR and lower percent recovery. Glucose excursions were larger and longer when CGM was masked than when unmasked. Conclusions: This analysis demonstrates “insulin metrics”—characterizations of insulin dosing behaviour derived from integrated CGM and CIP data—and provides a foundation for future work that will expand the understanding of an individual's insulin self‐administration practices and improve clinical decision‐making.


  • Response to Sensitivity of the Glycemia Risk Index to Effects of Automated Insulin Delivery Initiation

    by David C. Klonoff, Michael A. Kohn, David Rodbard, Rachel E. Aaron, Tiffany Tian

  • Association between glycaemia risk index ( GRI ) and diabetic retinopathy in type 2 diabetes: A cohort study

    by Yaxin Wang, Jingyi Lu, Jiaying Ni, Ming Wang, Yun Shen, Wei Lu, Wei Zhu, Yuqian Bao, David Rodbard, Robert A. Vigersky, et al.

    Aim: To investigate the association between a new composite metric, glycaemia risk index (GRI), and incident diabetic retinopathy (DR). Methods: A total of 1204 adults with type 2 diabetes without DR at baseline were included between 2005 and 2019 from a single centre in Shanghai, China. GRI was obtained from continuous glucose monitoring data at baseline. Cox proportion hazard regression analysis was used to assess the association between GRI and the risk of incident DR. Results: During a median follow‐up of 8.4 years, 301 patients developed DR. The multivariable‐adjusted hazard ratios (HRs) for incident DR across ascending GRI quartiles (≤14 [reference], 15 ~ 28, 29 ~ 47 and > 47) were 1.00, 1.05 (95% CI 0.74‐1.48), 1.33 (95% confidence interval [CI] 0.96‐1.84) and 1.53 (95% CI 1.11‐2.11), respectively. For each 1‐SD increase in GRI, the risk of DR was increased by 20% (HR 1.20, 95% CI 1.07‐1.33) after adjustment for confounders. Conclusions: In patients with type 2 diabetes, higher GRI is associated with an increased risk of incident DR. GRI has the potential to be a valuable clinical measure, which needs to be further explored in future studies.


  • Continuous glucose monitoring metrics (Mean Glucose, time above range and time in range) are superior to glycated haemoglobin for assessment of therapeutic efficacy

    by David Rodbard

    Aim: To evaluate continuous glucose monitoring (CGM) metrics for use as alternatives to glycated haemoglobin ( HbA1c ) to evaluate therapeutic efficacy. Methods: We re‐analysed correlations among CGM metrics from studies involving 545 people with type 1 diabetes (T1D), 5910 people with type 2 diabetes (T2D) and 98 people with T1D during pregnancy and the postpartum period. Results: Three CGM metrics, interstitial fluid Mean Glucose level, proportion of time above range ( %TAR ) and proportion of time in range ( %TIR ), were correlated with HbA1c and provided metrics that can be used to evaluate therapeutic efficacy. Mean Glucose showed the highest correlation with %TAR ( r = 0.98 in T1D, 0.97 in T2D) but weaker correlations with %TIR ( r = −0.92 in T1D, −0.83 in T2D) or with HbA1c ( r = 0.78 in T1D). %TAR and %TIR were highly correlated ( r = −0.96 in T1D, −0.91 in T2D). After 6 months of use of real‐time CGM by people with T1D, changes in Mean Glucose level were more highly correlated with changes in %TAR ( r = 0.95) than with changes in %TIR ( r = −0.85) or with changes in HbA1c level ( r = 0.52). These metrics can be combined with metrics of hypoglycaemia and/or glycaemic variability to provide a more comprehensive assessment of overall quality of glycaemic control. Conclusion: The CGM metrics %TAR and %TIR show much higher correlations with Mean Glucose than with HbA1c and provide sensitive indicators of efficacy. Mean glucose may be the best metric and shows consistently higher correlations with %TAR than with %TIR .


  • Top Cited Papers
    Open Access

    Consensus Recommendations for the Use of Automated Insulin Delivery Technologies in Clinical Practice

    by Moshe Phillip, Revital Nimri, Richard M Bergenstal, Katharine Barnard-Kelly, Thomas Danne, Roman Hovorka, Boris P Kovatchev, Laurel H Messer, Christopher G Parkin, Louise Ambler-Osborn, et al.

    The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage.


  • Top Cited Papers

    A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings

    by David C. Klonoff, Jing Wang, David Rodbard, Michael A. Kohn, Chengdong Li, Dorian Liepmann, David Kerr, David Ahn, Anne L. Peters, Guillermo E. Umpierrez, et al.

    Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low–glucose and low-glucose hypoglycemia; very high–glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. Results: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. Conclusion: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.


  • Quality of Glycemic Control: Assessment Using Relationships Between Metrics for Safety and Efficacy

    by David Rodbard

    Numerous methods have been proposed as measures of quality of glycemic control resulting in confusion regarding the best choice of metric to use by clinicians and researchers. Some methods use a single metric such as HbA1c , Mean Glucose , % T ime I n R ange ( %TIR ), or Coefficient of Variation ( %CV ). Others use a combination of up to seven metrics, for example, Q-Score, Comprehensive Glucose Pentagon ( CGP ), and Personal Glycemic State ( PGS ). A recently proposed Co mposite continuous G lucose monitoring i ndex utilizes three metrics: %TIR , T ime B elow R ange ( %TBR ), and standard deviation ( SD ) of glucose. This review proposes that only two metrics can be sufficient when monitoring an individual patient or when comparing two or more forms of management interventions. These two metrics comprise (1) a measure of efficacy such as Mean Glucose , HbA1c , %TIR , or %Time Above Range ( %TAR ) and (2) a measure of safety based on risk of hypoglycemia such as %TBR , L ow Blood G lucose I ndex ( L B GI) , or frequency of specified types of hypoglycemic events per patient year. By analysis of the two-dimensional graphical and statistical relationships between metrics for safety and efficacy and by testing identity versus nonidentity of these relationships, one can improve sensitivity for detection of the effects of medications and of other therapeutic interventions, avoid the need for arbitrary scoring systems for glucose values falling within versus outside the target range, and offer the advantage of conceptual and practical simplicity.


  • Open Access

    Insulin Metrics: Need for Development of Consensus Standards for Reporting of Insulin Dosing Data

    by Howard Wolpert, William H. Polonsky, David Rodbard

    The advent of connected insulin pens will generate an avalanche of digital insulin data, especially in the context of prandial- and multiple daily injection-insulin regimens. There is a need for the diabetes community to develop standards for such data, analogous to what has been achieved using the ambulatory glucose profile and associated metrics for glucose, permitting harmonization of data reporting for multiple devices and facilitating integration of glucose, insulin, food intake, and physical activity data. Several studies have estimated the timing of meals by analyses of glucose excursions but using diverse criteria. There is need for uniform criteria for multiple types of insulin boluses, including premeal, perimeal, delayed, missed, and correction boluses to facilitate research studies and patient care. This article contains a first preliminary proposal for standards regarding reporting of insulin dosing data. Clinical usage of these reports will require sensitive communication between health care providers and patients.


  • The Ambulatory Glucose Profile: Opportunities for Enhancement

    by David Rodbard

    The ambulatory glucose profile (AGP) and the frequency distribution for glucose by ranges are well established as standard methods for display, analysis, and interpretation of glucose data arising from self-monitoring, continuous glucose monitoring, and automated insulin delivery systems. In this review, we consider several refinements that may further improve the utility of the AGP. These include (1) display of the AGP together with information regarding dietary intake, medication administration (e.g., insulin), glucose lowering (pharmacodynamic) activity of medications, and physical activity measured by accelerometers or heart rate; (2) display of average time below range (%TBR), time above range (%TAR), and time in range (%TIR) by time of day to indicate timing of hypoglycemic and hyperglycemic episodes; (3) detailed analysis of postprandial excursions for each of the major meals after synchronizing by onset of meals and adjusting for the premeal glucose levels, enabling comparisons of magnitude, shape, and patterns; (4) methods to characterize distinct patterns on different days of the week; (5) display of glucose on a nonlinear scale to improve the balance between deviations associated with hypoglycemia versus hyperglycemia; (6) use of time scales other than midnight-to-midnight to facilitate analysis of time segments of particular interest (e.g., overnight); (7) options to display individual glucose values to assist in the identification of dates and times of outliers and episodes of hypoglycemia and hyperglycemia; and (8) methods to compare AGPs obtained from different individuals or groups receiving alternative interventions in terms of therapy or technology. These refinements, individually or collectively, can potentially further enhance the effectiveness of the AGP for assessment of glucose levels, patterns, and variability. We discuss several questions regarding implementation and optimization of these methods.


  • Standardizing Reporting of Glucose and Insulin Data for Patients on Multiple Daily Injections Using Connected Insulin Pens and Continuous Glucose Monitoring

    by David Rodbard, Satish K. Garg

    Background: Recent development and availability of several connected insulin pens with digital memory are likely to expand the availability of glucose and insulin metrics that previously had been available only for the much smaller number of people using insulin pumps. It would be highly desirable to standardize data presentations to avoid the chaotic emergence of multiple formats that might reduce the clinical utility of connected pens. Methods: We reviewed the literature and analyzed data displays from multiple blood glucose monitoring, continuous glucose monitoring (CGM), insulin pump, and automated insulin delivery systems, and methods for combination of glucose and insulin data. We examined multiple forms of presentation and now propose a prototype for a standardized method for data analysis and display, focusing on the content and format of a one-page dashboard summary for patients on multiple daily injection (MDI) insulin regimens. Results: We propose the following metrics to be included in the one-page report: (A) glucose metrics: simplified glucose distribution in the form of a stacked bar chart showing percentages of time below-, above-, or within-target ranges overall and (optionally) by date, by time of day, or day of the week; (B) insulin metrics: types and doses, and timing of basal and bolus insulin; (C) an enhanced ambulatory glucose profile or “AGP+” showing glucose data points and/or distributions (10th to 90th percentiles), dosages and timing of basal and bolus insulins and (optionally) graphical display of risk of hypoglycemia and hyperglycemia; and (D) user experience regarding technology usage, frequency of alerts for hypo- and hyperglycemia, and information regarding lifestyle, meals, exercise, and sleep, if available; and (E) clinical insights and interpretation. Conclusion: We propose a prototype for a dashboard summary report of glucose, insulin, meals, and activity data intended for providers and patients on MDI using connected pens and CGM. Our goal is to stimulate development of a standardized approach.