Lila Chaal
Lila Chaal has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Boualem Saidani
Université de Bejaia
8 shared publications - Jean Gamby
Université Paris‐Saclay CNRS Centre de Nanosciences et de Nanotechnologies Palaiseau France
8 shared publications Mohammed Kechadi
Laboratoire d'Electrochimie, Corrosion et de Valorisation Energétique (LECVE), Faculté de Technologie, Université de Bejaia, 06000, Algeria
7 shared publicationsBernard Tribollet
CNRS-LISE
6 shared publications- Alain Pailleret
Université Pierre et Marie Curie
4 shared publications C. Deslouis
4 shared publications
Latest Publications
- Open Access
- 1 December 2017
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 807, 203-212
Finite element modelling of non-faradic electric impedance spectroscopy through flexible polymer microchip
- 1 December 2017
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 807, 203-212
Open AccessFinite element modelling of non-faradic electric impedance spectroscopy through flexible polymer microchip
- 5 January 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 75 (38) , 47-52
(Invited) An Improved the Impedance Spectroscopy Measurements with Non-Contact Microelectrodes Embedded into a Flexible Polymer Comprising a Microfluidic Network
Two coplanar carbon microelectrodes were coated with the polymer by using a photoablation procedure in order to avoid any faradic reactions in the fluidic channel. In fact, only the dielectric properties of microelectrodes/ polymer/ fluidic channel interface are taken into consideration. This paper develops an analytical model that permits to predict the best frequency range to be selected for real-time contactless microchannel resistance changes. The non contact electric impedance spectroscopy is promising for new generation of sensor or biosensor applications on miniaturized flexible or patch polymer devices.
- 5 January 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 75 (38) , 47-52
(Invited) An Improved the Impedance Spectroscopy Measurements with Non-Contact Microelectrodes Embedded into a Flexible Polymer Comprising a Microfluidic Network
Two coplanar carbon microelectrodes were coated with the polymer by using a photoablation procedure in order to avoid any faradic reactions in the fluidic channel. In fact, only the dielectric properties of microelectrodes/ polymer/ fluidic channel interface are taken into consideration. This paper develops an analytical model that permits to predict the best frequency range to be selected for real-time contactless microchannel resistance changes. The non contact electric impedance spectroscopy is promising for new generation of sensor or biosensor applications on miniaturized flexible or patch polymer devices.
- Open Access
- 29 June 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 18 (30) , 20583-20590
Electrical impedance spectroscopy of a PET chip sandwiched between two disk electrodes: understanding the contribution of the polymer/electrode interface
The results highlight that the resistivity distribution obtained using the power-law model provided an appropriate description of the PET/electrode interface behaviour.
- 29 June 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 18 (30) , 20583-20590
Open AccessElectrical impedance spectroscopy of a PET chip sandwiched between two disk electrodes: understanding the contribution of the polymer/electrode interface
The results highlight that the resistivity distribution obtained using the power-law model provided an appropriate description of the PET/electrode interface behaviour.
- 1 May 2015
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 744, 101-109
Electrochemical characterization of viscoelastic solutions of supramolecular polymers in phosphonium-based ionic liquids
- 1 May 2015
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 744, 101-109
Electrochemical characterization of viscoelastic solutions of supramolecular polymers in phosphonium-based ionic liquids
- 5 October 2014
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 737, 108-113
Dielectric impedance spectroscopy of polymer-coated microelectrodes for adsorption monitoring of proteins within polymer microchannels
- 5 October 2014
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 737, 108-113
Dielectric impedance spectroscopy of polymer-coated microelectrodes for adsorption monitoring of proteins within polymer microchannels
- 20 March 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (12) , 3115-3121
A real time affinity biosensor on an insulated polymer using electric impedance spectroscopy in dielectric microchips
This paper presents development of real time monitoring of binding events on flexible plastic in microchips. Two planar carbon microelectrodes are integrated into an insulated polyethylene terephthalate microchip without direct electrical contact with the solution in the microchannel. It has been possible to probe the electric impedance changes through the interface constituted by the microelectrode/PET microchannel/solution when a biomolecular interaction takes place on the polymer surface. This new transduction for biosensing was demonstrated for the molecular recognition of BSA immobilized on the polymer microchannel surface using the corresponding rabbit anti-BSA antibodies as an analyte in the flow microchannel at the nanomolar range concentration. The equilibrium association constant was determined for the affinity reaction between both ligands and was obtained equal to 5 × 107 M−1. The promising results obtained with this new device make it a competitive biosensor.
- 20 March 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (12) , 3115-3121
A real time affinity biosensor on an insulated polymer using electric impedance spectroscopy in dielectric microchips
This paper presents development of real time monitoring of binding events on flexible plastic in microchips. Two planar carbon microelectrodes are integrated into an insulated polyethylene terephthalate microchip without direct electrical contact with the solution in the microchannel. It has been possible to probe the electric impedance changes through the interface constituted by the microelectrode/PET microchannel/solution when a biomolecular interaction takes place on the polymer surface. This new transduction for biosensing was demonstrated for the molecular recognition of BSA immobilized on the polymer microchannel surface using the corresponding rabbit anti-BSA antibodies as an analyte in the flow microchannel at the nanomolar range concentration. The equilibrium association constant was determined for the affinity reaction between both ligands and was obtained equal to 5 × 107 M−1. The promising results obtained with this new device make it a competitive biosensor.
- 6 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (6) , 1492-1497
Dynamics of BSA adsorption onto a photoablated polymer surface in a dielectric microchip
Impedance sensorgrams of adsorbed proteins on a microchannel obtained using contactless microelectrodes in a dielectric microchip.
- 6 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (6) , 1492-1497
Dynamics of BSA adsorption onto a photoablated polymer surface in a dielectric microchip
Impedance sensorgrams of adsorbed proteins on a microchannel obtained using contactless microelectrodes in a dielectric microchip.
- 1 July 2013
- Published by Springer Nature in Journal of Flow Chemistry
- Vol. 3 (3) , 81-86
Free Contact Microchannel Impedance Through Two Antiparallel Planar Microelectrodes
The present work describes new results using a contact free impedance device, which permits to reach a best understanding of the free contact transduction. Measurements were carried out through a polyethylene terephthalate (PET) microchannel photoablated. Impedance measurement of empty microchannel at different PET thickness separating the two electrodes demonstrate that the recorded impedance is not changed whatever the PET thickness. The result shows that the polyethylene (PE) film lamination has an effect on the impedance measurement in empty microchannel. Then impedances diagrams in the filled microchannel were plotted by subtracting impedance contribution in empty microchannel from the global microdevice response. The Nyquist diagram of filled microchannel exhibits a loop diameter from high to medium frequencies, and a capacitive behavior at low frequencies. The loop diameter obtained is inversely proportional to the microchannel conductivity. Modeling impedance of microsystem highlighted th...
- 1 July 2013
- Published by Springer Nature in Journal of Flow Chemistry
- Vol. 3 (3) , 81-86
Free Contact Microchannel Impedance Through Two Antiparallel Planar Microelectrodes
The present work describes new results using a contact free impedance device, which permits to reach a best understanding of the free contact transduction. Measurements were carried out through a polyethylene terephthalate (PET) microchannel photoablated. Impedance measurement of empty microchannel at different PET thickness separating the two electrodes demonstrate that the recorded impedance is not changed whatever the PET thickness. The result shows that the polyethylene (PE) film lamination has an effect on the impedance measurement in empty microchannel. Then impedances diagrams in the filled microchannel were plotted by subtracting impedance contribution in empty microchannel from the global microdevice response. The Nyquist diagram of filled microchannel exhibits a loop diameter from high to medium frequencies, and a capacitive behavior at low frequencies. The loop diameter obtained is inversely proportional to the microchannel conductivity. Modeling impedance of microsystem highlighted th...
- 1 March 2013
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 692, 46-52
Heterogeneous electron transfer and diffusivities of ferrocene/ferrocenium couple in toluene/phosphonium-based ionic liquid solutions
- 1 March 2013
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 692, 46-52
Heterogeneous electron transfer and diffusivities of ferrocene/ferrocenium couple in toluene/phosphonium-based ionic liquid solutions