XXXiaojuan Xia

Xiaojuan Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaojuan Xia has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Jean-Philippe Couderc

    Heart Research Follow-up Program, Cardiology Department, University of Rochester Medical Center, Rochester, NY, United States

    5 shared publications
  • Wojciech Zareba

    Heart Research Follow-up Program, Cardiology Department, University of Rochester Medical Center, Rochester, NY, United States

    3 shared publications
  • Arthur J. Moss

    Heart Research Follow-Up Program, University of Rochester, Rochester, NY, USA

    2 shared publications
  • Galen S. Wagner

    Duke Clinical Research Institute, Duke University, Durham, NC, USA

    2 shared publications
  • Alex Page

    University of Rochester Rochester NY USA

    1 shared publication
  • Alexander Novak

    University of Rochester

    1 shared publication

Latest Publications

  • Open Access

    Time-series ECG Imputation Using a Pattern-Based Masking Framework

    by Sukardi Suba, Alexander Novak, Xiaojuan Xia, Salah S Al-Zaiti, Michele M Pelter

    The utilization of continuous ECG monitoring has become an integral part of modern hospital-based care. However, missing data presents significant challenges in deploying real-time ECG-based predictive systems. Research on the implementation of imputation techniques on time-series ECG is limited. Furthermore, the performance of imputation techniques is typically benchmarked using random masking, which may not reflect the real-world missingness patterns encountered in clinical practice. This study aimed to evaluate and benchmark a range of imputation methods, from conventional statistical approaches to state-of-the-art deep learning models, using continuous ECG time-series data under different missingness conditions, including both random (conventional) and observed pattern-based (realistic) missingness. Time-domain features were extracted from continuous 12-lead Holter recordings (ranging from 2.5 to 4 hours per patient) from a pilot cohort of 40 patients. Missingness was introduced using random and pattern-based masking. We compared seven imputation methods: global mean, linear interpolation, K-Nearest Neighbors (KNN), Multiple Imputation by Chained Equations (MICE), softImpute, xgbooSt MIssing vaLues in timE Series (SMILES), and Self-Attention-based Imputation for Time Series (SAITS). Performance was evaluated using mean absolute error (MAE) across masking approaches, missingness levels, and missingness patterns. Overall, the MAEs for all seven imputations are higher under pattern-based masking than random masking. SAITS achieved the best performance across both masking approaches (MAEs of 0.277 and 0.146; standard deviations of absolute error of 0.398 and 0.252 for observed-pattern and random masking, respectively). Simpler methods such as SoftImpute and KNN showed comparable performance across both masking approaches, and particularly under certain missingness levels. Artificially masking by random may underestimate the accuracy of time-series imputation in real-world scenarios. Our findings underscore the importance of context-based imputation strategies (i.e., masking approach and imputation method) and balancing model complexity with practical considerations (e.g., resources, costs, and level of missingness) for real-time deployment. Keywords: electrocardiogram, imputation model, machine learning, time series

  • Population-based beat-to-beat QT analysis from Holter recordings in the long QT syndrome

    by Alex Page, Scott McNitt, Xiaojuan Xia, Wojciech Zareba, Jean-Philippe Couderc


  • Validation of an automatic diagnosis of strict left bundle branch block criteria using 12‐lead electrocardiograms

    by Xiaojuan Xia, Anne-Christine Ruwald, Martin H. Ruwald, Nene Ugoeke, Barbara Szepietowska, Valentina Kutyifa, Mehmet K. Aktas, Poul Erik B. Thomsen, Wojciech Zareba, Arthur J. Moss, et al.


  • Selvester scoring in patients with strict LBBB using the QUARESS software

    by Xiaojuan Xia, Uzma Chaudhry, Björn Wieslander, Rasmus Borgquist, Galen S. Wagner, David G. Strauss, Pyotr Platonov, Martin Ugander, Jean-Philippe Couderc


  • Automatic QRS Selvester scoring system in patients with left bundle branch block

    by Xiaojuan Xia, Björn Wieslander, David G. Strauss, Galen S. Wagner, Wojciech Zareba, Arthur J. Moss, Jean-Philippe Couderc

    Aims The Selvester QRS scoring system uses quantitative criteria from the standard 12-lead electrocardiogram (ECG) to estimate the myocardial scar size of patients, including those with left bundle branch block (LBBB). Automation of the scoring system could facilitate the clinical use of this technique which requires a set of multiple QRS patterns to be identified and measured. Methods and results We developed a series of algorithms to automatically detect and measure the QRS parameters required for Selvester scoring. The ‘QUantitative and Automatic REport of Selvester Score’ was designed specifically for the analysis of ECGs from patients meeting new strict criteria for complete LBBB. The algorithms were designed using a training ( n = 36) and a validation ( n = 180) set of ECGs, consisting of signal-averaged 12-lead ECGs (1000 Hz sampling) recorded from 216 LBBB patients from the MADIT-CRT. We assessed the performance of the methods using expert manually adjudicated ECGs. The average of absolute differences between automatic and adjudicated Selvester scoring was 1.2 ± 1.5 points. The range of average differences for continuous measurements of wave locations and interval durations varied between 0 and 6 ms. Erroneous detection of Q, R, S, R′, and S′ waves (oversensed or missed) were 3, 1, 1, 16, and 6%, respectively. Seven percent of notches detected in the first 40 ms were misdetected. Conclusion We propose an efficient computerized method for the automatic measurement of the Selvester score in patients with the strict LBBB.


  • Fractionated repolarization velocity induced by sotalol in healthy subjects

    by Martino Vaglio, Jean-Philippe Couderc, Xiaojuan Xia, Wojciech Zareba