David Willingham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Willingham has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Nicholas Winograd
Department of Chemistry, Pennsylvania State University, University Park, PA 16802, USA
9 shared publications Benjamin E. Naes
Pacific Northwest National Laboratory, Richland, USA
6 shared publicationsAlbert J. Fahey
Microscopy & Surface Analysis, Corning, Inc., Corning, USA
4 shared publications- Evan E. Groopman
Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA
4 shared publications - Jay Gage Tarolli
Ionpath, Inc., 960 O’Brien Dr., Menlo Park, California 94025, United States
3 shared publications A. Kucher
2 shared publications
Latest Publications
- 11 August 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (4) , 893-906
Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials
We present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post‐detonation nuclear forensics. The glasses were generated by melting and then quenching SiO2, Al2O3 and CaCO3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g‐1. Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry‐single stage accelerator mass spectrometry [SIMS‐SSAMS], large geometry [LG] ‐ SIMS, and laser ablation‐inductively coupled plasma‐mass spectrometry [LA‐ICP‐MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.
- 11 August 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (4) , 893-906
Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials
We present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post‐detonation nuclear forensics. The glasses were generated by melting and then quenching SiO2, Al2O3 and CaCO3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g‐1. Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry‐single stage accelerator mass spectrometry [SIMS‐SSAMS], large geometry [LG] ‐ SIMS, and laser ablation‐inductively coupled plasma‐mass spectrometry [LA‐ICP‐MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.
- 18 June 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (8) , 1647-1655
U–Pu Mixed Oxide Particle Analysis by NAUTILUS and Implications for Next-Generation Verification Challenges
Precise and accurate measurement of U and Pu isotopes from micrometer-sized particles represents new verification challenges for the International Atomic Energy Agency. The U and Pu isotopes and U–Pu elemental ratio provide valuable information about the intended use, the production process, and the purification process of Pu and mixed oxide (MOX) fuels. We demonstrate the ability to directly measure U and Pu isotopes from MOX fuel particles using the U.S. Naval Research Laboratory’s Naval Ultra-Trace Isotope Laboratory’s Universal Spectrometer (NAUTILUS). Reactor-grade MOX reference materials with well-characterized U and Pu isotopic composition (e.g., UKMOX10 and UKMOX100) were prepared using standard sample preparation methods for large geometry-secondary ion mass spectrometry (LG-SIMS). The results show that the NAUTILUS can discriminate the 238U1H+ signal from 239Pu+, enabling the accurate measurement of the 240Pu/239Pu ratio for MOX particles within 2σ of the certificate value for U–Pu ratios from 3:1 to 300:1. The accuracy of previously reported LG-SIMS measurements was limited to U–Pu ratios 234U/238U, 235U/238U, 236U/238U, 240Pu/239Pu, and 242Pu/239Pu ratios for UKMOX10 and UKMOX100 can all be measured accurately within 2σ of the reference values, directly, without correction. The application of the NAUTILUS to the accurate and precise determination of the elemental and isotopic composition of MOX particles in environmental samples may unravel some emerging verification challenges in international safeguards.
- 18 June 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (8) , 1647-1655
U–Pu Mixed Oxide Particle Analysis by NAUTILUS and Implications for Next-Generation Verification Challenges
Precise and accurate measurement of U and Pu isotopes from micrometer-sized particles represents new verification challenges for the International Atomic Energy Agency. The U and Pu isotopes and U–Pu elemental ratio provide valuable information about the intended use, the production process, and the purification process of Pu and mixed oxide (MOX) fuels. We demonstrate the ability to directly measure U and Pu isotopes from MOX fuel particles using the U.S. Naval Research Laboratory’s Naval Ultra-Trace Isotope Laboratory’s Universal Spectrometer (NAUTILUS). Reactor-grade MOX reference materials with well-characterized U and Pu isotopic composition (e.g., UKMOX10 and UKMOX100) were prepared using standard sample preparation methods for large geometry-secondary ion mass spectrometry (LG-SIMS). The results show that the NAUTILUS can discriminate the 238U1H+ signal from 239Pu+, enabling the accurate measurement of the 240Pu/239Pu ratio for MOX particles within 2σ of the certificate value for U–Pu ratios from 3:1 to 300:1. The accuracy of previously reported LG-SIMS measurements was limited to U–Pu ratios 234U/238U, 235U/238U, 236U/238U, 240Pu/239Pu, and 242Pu/239Pu ratios for UKMOX10 and UKMOX100 can all be measured accurately within 2σ of the reference values, directly, without correction. The application of the NAUTILUS to the accurate and precise determination of the elemental and isotopic composition of MOX particles in environmental samples may unravel some emerging verification challenges in international safeguards.
- 5 February 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (3) , 600-625
An overview of NRL's NAUTILUS: a combination SIMS-AMS for spatially resolved trace isotope analysis
We present a description of the capabilities and performance of the NAval Ultra-Trace Isotope Laboratory's Universal Spectrometer (NAUTILUS) at the U.S. Naval Research Laboratory, a combination SIMS-AMS for trace, in situ analyses.
- 5 February 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (3) , 600-625
An overview of NRL's NAUTILUS: a combination SIMS-AMS for spatially resolved trace isotope analysis
We present a description of the capabilities and performance of the NAval Ultra-Trace Isotope Laboratory's Universal Spectrometer (NAUTILUS) at the U.S. Naval Research Laboratory, a combination SIMS-AMS for trace, in situ analyses.
- 7 September 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (22) , 5364-5371
Direct, uncorrected, molecule-free analysis of 236 U from uranium-bearing particles with NAUTILUS: a new kind of mass spectrometer
The Naval Ultra-Trace Isotope Laboratory's Universal Spectrometer (NAUTILUS) can measure 236 U directly from uranium-bearing particles free from molecular isobaric interferences.
- 7 September 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (22) , 5364-5371
Direct, uncorrected, molecule-free analysis of 236 U from uranium-bearing particles with NAUTILUS: a new kind of mass spectrometer
The Naval Ultra-Trace Isotope Laboratory's Universal Spectrometer (NAUTILUS) can measure 236 U directly from uranium-bearing particles free from molecular isobaric interferences.
- 31 March 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (9) , 1499-1511
Fully convolutional neural network for removing background in noisy images of uranium bearing particles
Removal of background signal with near 99% accuracy from particle SIMS images using a fully convolutional neural network.
- 31 March 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (9) , 1499-1511
Fully convolutional neural network for removing background in noisy images of uranium bearing particles
Removal of background signal with near 99% accuracy from particle SIMS images using a fully convolutional neural network.
- 27 May 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (7) , 1472-1479
High resolution isotopic analysis of U-bearing particles via fusion of SIMS and EDS images
Image fusion of secondary ion mass spectrometry (SIMS) images and X-ray elemental maps from energy-dispersive spectroscopy (EDS) was performed to facilitate the isolation and re-analysis of isotopically unique U-bearing particles where the highest precision SIMS measurements are required. Image registration, image fusion and particle micromanipulation were performed on a subset of SIMS images obtained from a large area pre-screen of a particle distribution from a sample containing a mixture of several certified reference materials (CRM) U129A, U015, U150, U500 and U850, as well as a standard reference material (SRM) 8704 (Buffalo River Sediment) to simulate particles collected on swipes during routine inspections of declared uranium enrichment facilities by the International Atomic Energy Agency (IAEA). In total, fourteen particles, ranging in size from 5–15 μm, were isolated and re-analyzed by SIMS in multi-collector mode identifying nine particles of CRM U129A, one of U150, one of U500 and three of U850. These identifications were made based on the measured isotopic composition which was accurate to a few percent of the certified value and which proved to be consistent with the respective National Institute of Standards and Technology (NIST) certified atom percent values for 234U, 235U, 236U and 238U for the corresponding CRMs. This work represents the first use of image fusion for nuclear safeguards application, resulting in improved accuracy and precision of isotope ratio measurements for U-bearing particles. Implementation of image fusion is essential for the identification of particles of interest that fall below the spatial resolution of the SIMS images.
- 27 May 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (7) , 1472-1479
High resolution isotopic analysis of U-bearing particles via fusion of SIMS and EDS images
Image fusion of secondary ion mass spectrometry (SIMS) images and X-ray elemental maps from energy-dispersive spectroscopy (EDS) was performed to facilitate the isolation and re-analysis of isotopically unique U-bearing particles where the highest precision SIMS measurements are required. Image registration, image fusion and particle micromanipulation were performed on a subset of SIMS images obtained from a large area pre-screen of a particle distribution from a sample containing a mixture of several certified reference materials (CRM) U129A, U015, U150, U500 and U850, as well as a standard reference material (SRM) 8704 (Buffalo River Sediment) to simulate particles collected on swipes during routine inspections of declared uranium enrichment facilities by the International Atomic Energy Agency (IAEA). In total, fourteen particles, ranging in size from 5–15 μm, were isolated and re-analyzed by SIMS in multi-collector mode identifying nine particles of CRM U129A, one of U150, one of U500 and three of U850. These identifications were made based on the measured isotopic composition which was accurate to a few percent of the certified value and which proved to be consistent with the respective National Institute of Standards and Technology (NIST) certified atom percent values for 234U, 235U, 236U and 238U for the corresponding CRMs. This work represents the first use of image fusion for nuclear safeguards application, resulting in improved accuracy and precision of isotope ratio measurements for U-bearing particles. Implementation of image fusion is essential for the identification of particles of interest that fall below the spatial resolution of the SIMS images.
- 1 February 2016
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 22 (S3) , 228-229
Correlative Isotopic Analysis by Image Fusion of Electron Microscopy and Secondary Ion Mass Spectrometry Data
- 1 February 2016
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 22 (S3) , 228-229
Correlative Isotopic Analysis by Image Fusion of Electron Microscopy and Secondary Ion Mass Spectrometry Data
- Open Access
- 22 January 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (3) , 03H106
Image segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach
A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. Seeker) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five National Institute of Standards and Technology (NIST) uranium certified reference materials (CRM U129A, U015, U150, U500, and U850) were successfully identified in regions of SIMS image data (1) where a high variability in image intensity existed, (2) where particles were touching or were in close proximity to one another, and/or (3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by Seeker showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500, and U850. Additionally, comparison of the minor uranium isotope (234U, 235U, and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, Seeker could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, Seeker has application in addressing a broad set of image processing challenges.
- 22 January 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (3) , 03H106
Open AccessImage segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach
A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. Seeker) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five National Institute of Standards and Technology (NIST) uranium certified reference materials (CRM U129A, U015, U150, U500, and U850) were successfully identified in regions of SIMS image data (1) where a high variability in image intensity existed, (2) where particles were touching or were in close proximity to one another, and/or (3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by Seeker showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500, and U850. Additionally, comparison of the minor uranium isotope (234U, 235U, and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, Seeker could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, Seeker has application in addressing a broad set of image processing challenges.
- 1 March 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 97, 125-129
Secondary ion mass spectrometry signatures for verifying declarations of fissile‐material production
- 1 March 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 97, 125-129
Secondary ion mass spectrometry signatures for verifying declarations of fissile‐material production
- 6 February 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (5) , 1100-1107
Femtosecond laser ablation multicollector ICPMS analysis of uranium isotopes in NIST glass
We utilized femtosecond laser ablation together with multi-collector inductively coupled plasma mass spectrometry to measure the uranium isotopic content of NIST 61x (x = 0, 2, 4, 6) glasses. The uranium content of these glasses is a linear two-component mixing between isotopically natural uranium and the isotopically depleted spike used in preparing the glasses. Laser ablation results match extremely well, generally within a few ppm, with solution analysis following sample dissolution and chemical separation. In addition to isotopic data, sample utilization efficiency measurements indicate that over 1% of ablated uranium atoms reach a mass spectrometer detector, making this technique extremely efficient. Laser sampling also allows for spatial analysis and our data indicate that rare uranium concentration inhomogeneities exist in NIST 616 glass.
- 6 February 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (5) , 1100-1107
Femtosecond laser ablation multicollector ICPMS analysis of uranium isotopes in NIST glass
We utilized femtosecond laser ablation together with multi-collector inductively coupled plasma mass spectrometry to measure the uranium isotopic content of NIST 61x (x = 0, 2, 4, 6) glasses. The uranium content of these glasses is a linear two-component mixing between isotopically natural uranium and the isotopically depleted spike used in preparing the glasses. Laser ablation results match extremely well, generally within a few ppm, with solution analysis following sample dissolution and chemical separation. In addition to isotopic data, sample utilization efficiency measurements indicate that over 1% of ablated uranium atoms reach a mass spectrometer detector, making this technique extremely efficient. Laser sampling also allows for spatial analysis and our data indicate that rare uranium concentration inhomogeneities exist in NIST 616 glass.