Timothy A. Bigelow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Timothy A. Bigelow has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Huaiqing Wu
Department of Statistics, Iowa State University, Ames, IA 50011, USA
5 shared publications Jin Xu
Eng., John Brown Univ., Siloam Springs, AR
5 shared publicationsYassin Labyed
Los Alamos National Lab
4 shared publications- Clayton L. Thomas
Center for Nondestructive Evaluation, Iowa State University, Ames, USA
3 shared publications Dan J. Stessman
Department of Genetics, Development, and Cell Biology, Iowa State University, Ames, Iowa 50011
2 shared publicationsDingiswayo A. Chikhwaza
2 shared publications
Latest Publications
- 7 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 171
Image-processing-based detection of defective ultrasound transducer elements using clinical B-mode images
- 7 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 171
Image-processing-based detection of defective ultrasound transducer elements using clinical B-mode images
- 1 August 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (2) , 1632-1641
Multimodal ultrasound-based localization of surgical mesh using Nakagami parametric imaging and shear wave elastography—An in vitro and ex vivo study
Surgical mesh is widely used in soft tissue reinforcement treatments as it results in a lower recurrence rate of complications. However, there is a possibility of abnormalities after mesh implantation. These problems can result in chronic discomfort and demand further surgical procedures and postoperative monitoring. Hence, mesh visualization and detection are essential for understanding postoperative outcomes and surgical planning. However, using traditional imaging modalities, these meshes are difficult to visualize after implantation against surrounding tissues. Therefore, it is challenging to locate the implanted mesh accurately. The hypothesis for this work was that ultrasound shear wave elastography (SWE) and Nakagami parametric imaging could be useful methods for localizing and assessing the implanted mesh, as the mesh differs in mechanical stiffness, along with its echogenicity and the statistical distribution of backscattered signals compared to the surrounding tissue. This study demonstrates the potential of Nakagami imaging and SWE for accurately localizing surgical meshes. While both methods allowed for accurate mesh location recognition, Nakagami imaging provided better localization for meshes located at larger depths. According to these findings, this method could especially be helpful for patients with thick abdominal walls. This could enhance the clinical evaluation of hernia mesh implantation and improve diagnostic accuracy.
- 1 August 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (2) , 1632-1641
Multimodal ultrasound-based localization of surgical mesh using Nakagami parametric imaging and shear wave elastography—An in vitro and ex vivo study
Surgical mesh is widely used in soft tissue reinforcement treatments as it results in a lower recurrence rate of complications. However, there is a possibility of abnormalities after mesh implantation. These problems can result in chronic discomfort and demand further surgical procedures and postoperative monitoring. Hence, mesh visualization and detection are essential for understanding postoperative outcomes and surgical planning. However, using traditional imaging modalities, these meshes are difficult to visualize after implantation against surrounding tissues. Therefore, it is challenging to locate the implanted mesh accurately. The hypothesis for this work was that ultrasound shear wave elastography (SWE) and Nakagami parametric imaging could be useful methods for localizing and assessing the implanted mesh, as the mesh differs in mechanical stiffness, along with its echogenicity and the statistical distribution of backscattered signals compared to the surrounding tissue. This study demonstrates the potential of Nakagami imaging and SWE for accurately localizing surgical meshes. While both methods allowed for accurate mesh location recognition, Nakagami imaging provided better localization for meshes located at larger depths. According to these findings, this method could especially be helpful for patients with thick abdominal walls. This could enhance the clinical evaluation of hernia mesh implantation and improve diagnostic accuracy.
- 5 July 2025
- Published by Elsevier in Ultrasonics
- Vol. 156, 107730
Impact of low-amplitude pulse interspersed with histotripsy treatment of Staphylococcus aureus biofilms on surgical mesh
- 5 July 2025
- Published by Elsevier in Ultrasonics
- Vol. 156, 107730
Impact of low-amplitude pulse interspersed with histotripsy treatment of Staphylococcus aureus biofilms on surgical mesh
- 27 July 2023
- Published by Springer Nature
- Vol. 1403, 67-84
Attenuation Compensation and Estimation
Estimating the loss of ultrasound signal with propagation depth as a function of frequency is essential for quantifying tissue properties. Specifically, ultrasound attenuation is used to correct for spectral distortion prior to estimating quantitative ultrasound parameters to assess the tissue. Ultrasound attenuation can also be used independently to characterize the tissue. In this chapter, we review the primary algorithms for estimating both the local attenuation within a region of interest as well as the total attenuation between a region of interest and an ultrasound source. The strengths and weaknesses of each algorithm are also discussed. Keywords Attenuation Local attenuation Total attenuation Spectral difference method Spectral-log difference method Hybrid method Spectral-fit method Multiple filter method
- 27 July 2023
- Published by Springer Nature
- Vol. 1403, 67-84
Attenuation Compensation and Estimation
Estimating the loss of ultrasound signal with propagation depth as a function of frequency is essential for quantifying tissue properties. Specifically, ultrasound attenuation is used to correct for spectral distortion prior to estimating quantitative ultrasound parameters to assess the tissue. Ultrasound attenuation can also be used independently to characterize the tissue. In this chapter, we review the primary algorithms for estimating both the local attenuation within a region of interest as well as the total attenuation between a region of interest and an ultrasound source. The strengths and weaknesses of each algorithm are also discussed. Keywords Attenuation Local attenuation Total attenuation Spectral difference method Spectral-log difference method Hybrid method Spectral-fit method Multiple filter method
- 27 February 2020
- Published by Springer Nature
- p. 1-33
Circuit Model Components
- 27 February 2020
- Published by Springer Nature
- p. 179-211
Reactive Circuit Transient Response
- 27 February 2020
- Published by Springer Nature
- p. 213-254
Phasor-Domain Circuit Analysis
- 27 February 2020
- Published by Springer Nature
- p. 345-362
Balanced Three-Phase Circuits