Ying Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ying Zhu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Brian Bewer
Physics and Engineering Physics, University of Saskatchewan, 116 Science Place, Saskatoon, SK S7N 5E2, Canada
4 shared publicationsDean Chapman
Anatomy and Cell Biology, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK S7N 5E5, Canada
4 shared publicationsHonglin Zhang
Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
4 shared publications- Steven K. Boyd
McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary , Calgary, AB T2N 4Z6
4 shared publications Helen Nichol
Anatomy and Cell Biology, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK S7N 5E5, Canada
3 shared publicationsD Chapman
Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK, Canada
2 shared publications
Latest Publications
- 3 September 2020
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 62 (5) , 542-553
Contrast-enhanced x-ray microscopy of articular cartilage
Osteoarthritis is a common chronic disease of joints characterized by degenerative changes of articular cartilage. An early diagnosis of osteoarthritis may be possible when imaging excised tissue for research in situ at the cellular-molecular scale. Whereas cartilage histopathology is destructive, time-consuming, and limited to 2D views, contrast-enhanced x-ray microscopy (XRM) can image articular cartilage and subchondral bone in 3D. This study evaluates articular cartilage structure ex vivo using both techniques. Osteochondral plugs were excised from non-diseased bovine knees and stained in phosphotungstic acid for 0 to 32 hours. XRM imaging revealed an optimal staining time of 16 hrs and a saturated staining time of 24 hrs. Histology sections were cut and analysed by polarized light microscopy (PLM) and second-harmonic-generation dual-photon (SHG-DP) microscopy. Histology photomicrographs were aligned with matching XRM slices, and evaluated for features relevant in histopathological scoring of osteoarthritis cartilage, including the tidemark, collagen architecture and chondrocyte morphology. The cartilage collagen network and chondrocytes from the 3D contrast-enhanced XRM were correlated with the 2D histology. This technique has two distinct advantages over routine histopathology: (1) the avoidance of dehydration, demineralization, and deformation of histological sectioning, thereby preserving the intact articular cartilage and subchondral bone plate ex vivo, and (2) the ability to evaluate the entire osteochondral volume in 3D. This work explores several diagnostic features of imaging cartilage, including: visualization of the tidemark in XRM and SHG-DP microscopy, validating the morphology of chondrocytes and nuclei with XRM, SHG-DP and PLM, and correlating collagen birefringence with XRM image intensity.
- 3 September 2020
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 62 (5) , 542-553
Contrast-enhanced x-ray microscopy of articular cartilage
Osteoarthritis is a common chronic disease of joints characterized by degenerative changes of articular cartilage. An early diagnosis of osteoarthritis may be possible when imaging excised tissue for research in situ at the cellular-molecular scale. Whereas cartilage histopathology is destructive, time-consuming, and limited to 2D views, contrast-enhanced x-ray microscopy (XRM) can image articular cartilage and subchondral bone in 3D. This study evaluates articular cartilage structure ex vivo using both techniques. Osteochondral plugs were excised from non-diseased bovine knees and stained in phosphotungstic acid for 0 to 32 hours. XRM imaging revealed an optimal staining time of 16 hrs and a saturated staining time of 24 hrs. Histology sections were cut and analysed by polarized light microscopy (PLM) and second-harmonic-generation dual-photon (SHG-DP) microscopy. Histology photomicrographs were aligned with matching XRM slices, and evaluated for features relevant in histopathological scoring of osteoarthritis cartilage, including the tidemark, collagen architecture and chondrocyte morphology. The cartilage collagen network and chondrocytes from the 3D contrast-enhanced XRM were correlated with the 2D histology. This technique has two distinct advantages over routine histopathology: (1) the avoidance of dehydration, demineralization, and deformation of histological sectioning, thereby preserving the intact articular cartilage and subchondral bone plate ex vivo, and (2) the ability to evaluate the entire osteochondral volume in 3D. This work explores several diagnostic features of imaging cartilage, including: visualization of the tidemark in XRM and SHG-DP microscopy, validating the morphology of chondrocytes and nuclei with XRM, SHG-DP and PLM, and correlating collagen birefringence with XRM image intensity.
- Open Access
- 1 October 2015
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 3 (4) , 212-218
Cartilage imaging of a rabbit knee using dual-energy X-ray microscopy and 1.0 T and 9.4 T magnetic resonance imaging
- 1 October 2015
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 3 (4) , 212-218
Open AccessCartilage imaging of a rabbit knee using dual-energy X-ray microscopy and 1.0 T and 9.4 T magnetic resonance imaging
- 28 April 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (10) , 2485-2503
SpectralK-edge subtraction imaging
We describe a spectral x-ray transmission method to provide images of independent material components of an object using a synchrotron x-ray source. The imaging system and process is similar to K-edge subtraction (KES) imaging where two imaging energies are prepared above and below the K-absorption edge of a contrast element and a quantifiable image of the contrast element and a water equivalent image are obtained. The spectral method, termed 'spectral-KES' employs a continuous spectrum encompassing an absorption edge of an element within the object. The spectrum is prepared by a bent Laue monochromator with good focal and energy dispersive properties. The monochromator focuses the spectral beam at the object location, which then diverges onto an area detector such that one dimension in the detector is an energy axis. A least-squares method is used to interpret the transmitted spectral data with fits to either measured and/or calculated absorption of the contrast and matrix material-water. The spectral-KES system is very simple to implement and is comprised of a bent Laue monochromator, a stage for sample manipulation for projection and computed tomography imaging, and a pixelated area detector. The imaging system and examples of its applications to biological imaging are presented. The system is particularly well suited for a synchrotron bend magnet beamline with white beam access.
- 28 April 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (10) , 2485-2503
SpectralK-edge subtraction imaging
We describe a spectral x-ray transmission method to provide images of independent material components of an object using a synchrotron x-ray source. The imaging system and process is similar to K-edge subtraction (KES) imaging where two imaging energies are prepared above and below the K-absorption edge of a contrast element and a quantifiable image of the contrast element and a water equivalent image are obtained. The spectral method, termed 'spectral-KES' employs a continuous spectrum encompassing an absorption edge of an element within the object. The spectrum is prepared by a bent Laue monochromator with good focal and energy dispersive properties. The monochromator focuses the spectral beam at the object location, which then diverges onto an area detector such that one dimension in the detector is an energy axis. A least-squares method is used to interpret the transmitted spectral data with fits to either measured and/or calculated absorption of the contrast and matrix material-water. The spectral-KES system is very simple to implement and is comprised of a bent Laue monochromator, a stage for sample manipulation for projection and computed tomography imaging, and a pixelated area detector. The imaging system and examples of its applications to biological imaging are presented. The system is particularly well suited for a synchrotron bend magnet beamline with white beam access.
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (5) , 052010
A novel beam width doubling double crystal monochromator -some preliminary findings
The maximum useable beam width at the Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source (CLS) is suitable for most imaging applications. But access to a wider beam would benefit many programs especially computed tomography where the beam width defines the largest sample that can be imaged. A double crystal bent Laue monochromator capable of doubling the width of the incident beam is proposed; this is possible by taking advantage of symmetric off-axis, or skew reflections in the crystals. A preliminary experiment to establish proof of concept for this design has been completed using a double crystal unbent Laue system. Results are presented showing the beam width doubling from 28.3mm to 56.6mm and the effect of the skew reflections on the monochromaticity of the exit beam. Further work on this monochromator will include an investigation into the choice of reflections, a study of the effect on the change in energy across the exit beam, the development of strategies to minimize the effect of the beam overlap region downstream from the monochromator and the development of an alignment process for the double crystal bent Laue system.
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (5) , 052010
A novel beam width doubling double crystal monochromator -some preliminary findings
The maximum useable beam width at the Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source (CLS) is suitable for most imaging applications. But access to a wider beam would benefit many programs especially computed tomography where the beam width defines the largest sample that can be imaged. A double crystal bent Laue monochromator capable of doubling the width of the incident beam is proposed; this is possible by taking advantage of symmetric off-axis, or skew reflections in the crystals. A preliminary experiment to establish proof of concept for this design has been completed using a double crystal unbent Laue system. Results are presented showing the beam width doubling from 28.3mm to 56.6mm and the effect of the skew reflections on the monochromaticity of the exit beam. Further work on this monochromator will include an investigation into the choice of reflections, a study of the effect on the change in energy across the exit beam, the development of strategies to minimize the effect of the beam overlap region downstream from the monochromator and the development of an alignment process for the double crystal bent Laue system.
- 6 July 2010
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1234 (1) , 457-460
Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues—Preliminary Results
Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson’s disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X‐ray Absorption Spectroscopy (XAS) and in particular X‐ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra‐dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X‐ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.
- 6 July 2010
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1234 (1) , 457-460
Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues—Preliminary Results
Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson’s disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X‐ray Absorption Spectroscopy (XAS) and in particular X‐ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra‐dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X‐ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.
- 1 August 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (8) , 085102
Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals
A novel combined imaging system for small animals using dilute concentrations of iodine as a contrast agent was developed for wide and pencil photon beam image acquisitions. This combined imaging system used K-edge subtraction (KES) and fluorescence subtraction imaging (FSI) and was tested at the Hard x-ray Microanalysis beamline at the Canadian Light Source. The initial wide beam KES image acquired with a charge-coupled device camera was used to identify regions of interest for further investigation and determine the location and area of the raster scan for pencil beam imaging. The pencil photon beam scanning mode acquired simultaneously KES and FSI measurements with an ionization chamber measuring the KES data and a multielement germanium detector measuring the FSI data. A description of the system is given as well as preliminary results using an iodine test object.
- 1 August 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (8) , 085102
Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals
A novel combined imaging system for small animals using dilute concentrations of iodine as a contrast agent was developed for wide and pencil photon beam image acquisitions. This combined imaging system used K-edge subtraction (KES) and fluorescence subtraction imaging (FSI) and was tested at the Hard x-ray Microanalysis beamline at the Canadian Light Source. The initial wide beam KES image acquired with a charge-coupled device camera was used to identify regions of interest for further investigation and determine the location and area of the raster scan for pencil beam imaging. The pencil photon beam scanning mode acquired simultaneously KES and FSI measurements with an ionization chamber measuring the KES data and a multielement germanium detector measuring the FSI data. A description of the system is given as well as preliminary results using an iodine test object.