Kathryn Busch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathryn Busch has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Avolio
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
4 shared publications - Hosen Kiat
Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW 2109, Australia; College of Health and Medicine, Australian National University, Canberra, ACT 2601, Australia; NICM Health Research Institute, Western Sydney University, Westmead, NSW 2145, Australia
4 shared publications - Andrew Stewart Davidson
Neurosurgery, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, AUS
3 shared publications - Mark Butlin
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
2 shared publications Andrew Davidson
1 shared publicationGeoffrey White
Department of Vascular Surgery, RPA Hospital, Camperdown, NSW, Australia
1 shared publication
Latest Publications
- Open Access
- 31 December 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (S1) , S35
P.14 Transcranial Colour Duplex Reveals Haemodynamically Significant Venous Flow Alterations Following Resection of Arteriovenous Malformation of the Brain
- 31 December 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (S1) , S35
Open AccessP.14 Transcranial Colour Duplex Reveals Haemodynamically Significant Venous Flow Alterations Following Resection of Arteriovenous Malformation of the Brain
- Open Access
- 6 January 2020
- Published by Springer Nature in Cureus
- Vol. 12 (1) , c26
Obstructive Hydrocephalus Due to Unruptured Brain Arteriovenous Malformation: Demonstrating Transcranial Color Duplex Confirmation of Cerebral Venous Hemodynamic Alterations and Color Duplex Ultrasound Confirmation of Shunt Patency (vol 12, e26, 2020)
The following errors have been corrected (all located in the three paragraphs between Figures 6 and 7 in the Case Presentation section): First paragraph: "(Figure 4C)" reference removed and "(Figure 6A, 6B)" reference added. Second paragraph: "Pressure support ventilation" replaced with "peak systemic velocity", "volume" replaced with "velocity", and "(Figure 7)" reference added. Third paragraph: "VM" replaced with "mean velocity" and "(Figure 7)" reference removed.
- 6 January 2020
- Published by Springer Nature in Cureus
- Vol. 12 (1) , c26
Open AccessObstructive Hydrocephalus Due to Unruptured Brain Arteriovenous Malformation: Demonstrating Transcranial Color Duplex Confirmation of Cerebral Venous Hemodynamic Alterations and Color Duplex Ultrasound Confirmation of Shunt Patency (vol 12, e26, 2020)
The following errors have been corrected (all located in the three paragraphs between Figures 6 and 7 in the Case Presentation section): First paragraph: "(Figure 4C)" reference removed and "(Figure 6A, 6B)" reference added. Second paragraph: "Pressure support ventilation" replaced with "peak systemic velocity", "volume" replaced with "velocity", and "(Figure 7)" reference added. Third paragraph: "VM" replaced with "mean velocity" and "(Figure 7)" reference removed.
- Open Access
- 18 November 2019
- Published by Springer Nature in Cureus
- Vol. 11 (11) , e6181
Obstructive Hydrocephalus Due to Unruptured Brain Arteriovenous Malformation: Demonstrating Transcranial Color Duplex Confirmation of Cerebral Venous Hemodynamic Alterations and Color Duplex Ultrasound Confirmation of Shunt Patency
Given the rarity of arteriovenous malformations of the brain (bAVMs) with concomitant obstructive hydrocephalus, few papers have commented on the resultant hydrodynamic perturbations. To date, no study has specifically investigated the effect of ventricular shunting on intracranial venous parameters as measured by transcranial color duplex ultrasound (TCCD). This study investigates whether TCCD and color duplex ultrasound are useful modalities to elucidate the physiological and hemodynamic changes in a patient with bAVM following ventricular shunting. Using TCCD, this study demonstrates that preoperatively, there is a decrease in cerebral capacitance, manifesting in a decrease in cerebral inflow and reduced venous outflow. Following shunt insertion, intracranial compliance is increased, resulting in the dilatation of previously compressed capacitance vessels and restoration of venous compliance. Color duplex ultrasound (CDU) was a useful determinant of shunt patency in the neck. We report the first TCCD assessment of hemodynamic changes of the intracranial circulation in a patient with bAVM following ventricular-peritoneal shunting. The results lend conceptual support of a pressure gradient change with high pressure that occurs in the veins as compared to the subarachnoid space.
- 18 November 2019
- Published by Springer Nature in Cureus
- Vol. 11 (11) , e6181
Open AccessObstructive Hydrocephalus Due to Unruptured Brain Arteriovenous Malformation: Demonstrating Transcranial Color Duplex Confirmation of Cerebral Venous Hemodynamic Alterations and Color Duplex Ultrasound Confirmation of Shunt Patency
Given the rarity of arteriovenous malformations of the brain (bAVMs) with concomitant obstructive hydrocephalus, few papers have commented on the resultant hydrodynamic perturbations. To date, no study has specifically investigated the effect of ventricular shunting on intracranial venous parameters as measured by transcranial color duplex ultrasound (TCCD). This study investigates whether TCCD and color duplex ultrasound are useful modalities to elucidate the physiological and hemodynamic changes in a patient with bAVM following ventricular shunting. Using TCCD, this study demonstrates that preoperatively, there is a decrease in cerebral capacitance, manifesting in a decrease in cerebral inflow and reduced venous outflow. Following shunt insertion, intracranial compliance is increased, resulting in the dilatation of previously compressed capacitance vessels and restoration of venous compliance. Color duplex ultrasound (CDU) was a useful determinant of shunt patency in the neck. We report the first TCCD assessment of hemodynamic changes of the intracranial circulation in a patient with bAVM following ventricular-peritoneal shunting. The results lend conceptual support of a pressure gradient change with high pressure that occurs in the veins as compared to the subarachnoid space.
- 1 December 2017
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 46, 165-166
Improving the quality of the evidence – The necessity to lead by example
- 1 December 2017
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 46, 165-166
Improving the quality of the evidence – The necessity to lead by example
- Open Access
- 31 August 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (8) , e173
Ascertaining the Value of Noninvasive Measures Obtained Using Color Duplex Ultrasound and Central Aortic Pressure Monitoring During the Management of Cerebral Arteriovenous Malformation Resection: Protocol for a Prospective, Case Control Pilot Study
Dramatic hemodynamic changes occur upon removal of an arteriovenous malformation of the brain (bAVM) with a number of potentially serious perioperative complications, such as intracranial hemorrhage and venous occlusive hypertensive syndrome. As these complications largely occur in the postoperative inpatient period, a rapid, repeatable noninvasive investigation to serially monitor relevant intracranial hemodynamics may be of benefit. Though, transcranial Doppler (TCD) and transcranial color duplex (TCCD) are techniques used and available to provide hemodynamic measurements postoperatively, the time course of hemodynamic sequences following bAVM resection remains uncertain. This is a prospective, case control pilot study conducted in participants having elective bAVM resection surgery. Each participant will undergo a preoperative color duplex ultrasound (CDU) of the bilateral extracranial carotid arteries, a CDU of the circle of Willis including the bAVM vessels, and a central aortic pressure measurement, repeated daily, postoperatively, for a 2-week period. Patient accrual has commenced with anticipation of first results in 2018. This protocol aims to strengthen the work of previous authors by providing documentation of the time course of hemodynamic changes following bAVM resection. The protocol is designed to determine whether noninvasive technology, including CDU imaging of the extracranial carotid and intracranial arteries in the form of TCCD along with central aortic pressure measurements, can determine whether there are any hemodynamically significant prognostic markers that may provide insight into the process of vessel remodeling, including insight into venous changes following bAVM resection.
- 31 August 2017
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 6 (8) , e173
Open AccessAscertaining the Value of Noninvasive Measures Obtained Using Color Duplex Ultrasound and Central Aortic Pressure Monitoring During the Management of Cerebral Arteriovenous Malformation Resection: Protocol for a Prospective, Case Control Pilot Study
Dramatic hemodynamic changes occur upon removal of an arteriovenous malformation of the brain (bAVM) with a number of potentially serious perioperative complications, such as intracranial hemorrhage and venous occlusive hypertensive syndrome. As these complications largely occur in the postoperative inpatient period, a rapid, repeatable noninvasive investigation to serially monitor relevant intracranial hemodynamics may be of benefit. Though, transcranial Doppler (TCD) and transcranial color duplex (TCCD) are techniques used and available to provide hemodynamic measurements postoperatively, the time course of hemodynamic sequences following bAVM resection remains uncertain. This is a prospective, case control pilot study conducted in participants having elective bAVM resection surgery. Each participant will undergo a preoperative color duplex ultrasound (CDU) of the bilateral extracranial carotid arteries, a CDU of the circle of Willis including the bAVM vessels, and a central aortic pressure measurement, repeated daily, postoperatively, for a 2-week period. Patient accrual has commenced with anticipation of first results in 2018. This protocol aims to strengthen the work of previous authors by providing documentation of the time course of hemodynamic changes following bAVM resection. The protocol is designed to determine whether noninvasive technology, including CDU imaging of the extracranial carotid and intracranial arteries in the form of TCCD along with central aortic pressure measurements, can determine whether there are any hemodynamically significant prognostic markers that may provide insight into the process of vessel remodeling, including insight into venous changes following bAVM resection.
- 14 March 2009
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 33 (1) , 36-39
Horseshoes Are Not Always Lucky: A Rare Cause of Varicose Veins
Introduction: Color duplex ultrasound (CDU) assessment for patients with varicose veins has increased in prevalence as new techniques for treatment continue to emerge. Occasionally, patients present with atypical varicosities that warrant the typical study to be extended to unveil the true underlying cause of the condition. Clinical Details: A 41 year old man presented to our laboratory for assessment of bilateral varicose veins. He had recently developed venous eczema. Examination of the patient revealed large varicose veins associated with the long saphenous system, especially prominent on the left side. Methods: Using a standard venous incompetence study protocol, CDU was performed with a Philips IU22 machine. The lower-extremity deep and superficial venous systems were assessed for patency and competency. Measurements of incompetent venous junctions and noteworthy vessel diameters were included. The examination was extended to include the pelvic and abdominal veins on the basis of unusual findings during the CDU imaging of the legs. Results: Superficial venous insufficiency was detected involving the saphenofemoral junctions (SFJs), long saphenous veins (LSVs), and tributaries bilaterally. Bilateral incompetent calf perforators were identified. On the left, two large SFJs were identified and the LSV measured up to 2.1 cm in diameter. On both sides, an incompetent superficial pelvic vein arising from the SFJ was identified tracking proximally. Examination of the iliac veins revealed normal right iliac veins. On the left, the common iliac vein was extrinsically compressed as was the inferior vena cava. Further examination revealed a horseshoe kidney. The confluence of the lower poles of the kidneys were anterior to the aorta, inferior vena cava, and left common iliac vein, compressing the venous vasculature, accounting for the venous hypertension and left sided prominence. Further management included confirmatory radiological imaging and intervention. Conclusion: Atypical varicose veins may be a result of a plethora of causes. It is crucial to the patient's outcome to reveal the true nature of the underlying cause. Abdominal sources of venous incompetence need appropriately tailored intervention to prevent recurrence and potential worsening of symptoms.
- 14 March 2009
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 33 (1) , 36-39
Horseshoes Are Not Always Lucky: A Rare Cause of Varicose Veins
Introduction: Color duplex ultrasound (CDU) assessment for patients with varicose veins has increased in prevalence as new techniques for treatment continue to emerge. Occasionally, patients present with atypical varicosities that warrant the typical study to be extended to unveil the true underlying cause of the condition. Clinical Details: A 41 year old man presented to our laboratory for assessment of bilateral varicose veins. He had recently developed venous eczema. Examination of the patient revealed large varicose veins associated with the long saphenous system, especially prominent on the left side. Methods: Using a standard venous incompetence study protocol, CDU was performed with a Philips IU22 machine. The lower-extremity deep and superficial venous systems were assessed for patency and competency. Measurements of incompetent venous junctions and noteworthy vessel diameters were included. The examination was extended to include the pelvic and abdominal veins on the basis of unusual findings during the CDU imaging of the legs. Results: Superficial venous insufficiency was detected involving the saphenofemoral junctions (SFJs), long saphenous veins (LSVs), and tributaries bilaterally. Bilateral incompetent calf perforators were identified. On the left, two large SFJs were identified and the LSV measured up to 2.1 cm in diameter. On both sides, an incompetent superficial pelvic vein arising from the SFJ was identified tracking proximally. Examination of the iliac veins revealed normal right iliac veins. On the left, the common iliac vein was extrinsically compressed as was the inferior vena cava. Further examination revealed a horseshoe kidney. The confluence of the lower poles of the kidneys were anterior to the aorta, inferior vena cava, and left common iliac vein, compressing the venous vasculature, accounting for the venous hypertension and left sided prominence. Further management included confirmatory radiological imaging and intervention. Conclusion: Atypical varicose veins may be a result of a plethora of causes. It is crucial to the patient's outcome to reveal the true nature of the underlying cause. Abdominal sources of venous incompetence need appropriately tailored intervention to prevent recurrence and potential worsening of symptoms.