Brad Holschuh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brad Holschuh has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Rachael Granberry
University of Minnesota
8 shared publications - Heidi Woelfle
Department of Design Innovation, University of Minnesota Twin Cities
7 shared publications - Alireza Golgouneh
Department of Electrical Engineering, University of Minnesota-Twin Cities, Minneapolis, MN 55455, United States of America
6 shared publications Esther Foo
University of Minnesota, St Paul, MN, USA
6 shared publicationsJ. Walter Lee
Human Factors and Ergonomics
6 shared publications- Julianna Abel
Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, Minnesota, 55455, UNITED STATES
6 shared publications
Latest Publications
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 549-553
SoloBand: A Maternity Support Band with the One-Handed Tightening System for Pregnant Individuals
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 549-553
Open AccessSoloBand: A Maternity Support Band with the One-Handed Tightening System for Pregnant Individuals
- Open Access
- 1 October 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (10) , 105017
Fatigue-aware force estimation for NiTi SMA actuators using LSTM recurrent networks
This study focuses on the force estimation of NiTi shape memory alloy (SMA) actuators, particularly addressing the challenges posed by material fatigue and force degradation over repeated actuation cycles. Traditional modeling approaches for SMAs, which typically include constitutive, phase transformation, and heat transfer sub-models, often fail to account for these degradation phenomena, leading to inaccuracies in long-term predictions. To overcome these limitations, we developed and implemented multivariate long short-term memory (LSTM) recurrent neural networks for accurate force estimation using measured parameters such as electrical power (current, voltage), strain, and temperature. An extensive experimental setup was designed to cyclically and electrothermally (Joule heating) activate the SMA actuators at varying strain levels, and the degradation in force production was quantified, with a reduction of up to 20.62% observed after 1000 cycles. The study introduced both single-stage and two-stage LSTM architectures, with the SLF model, which incorporates historical force data along with other measurements, achieving the highest accuracy (RMSE of 0.003 N). More sensor-limited and deployment-oriented variants also performed well: SLWF and SLWTF achieved RMSEs of 0.089 N and 0.110 N, respectively, and the two-stage MTSL (with learned temperature as a hidden state) achieved 0.096 N. The proposed LSTM-based models demonstrated their efficacy in providing reliable force estimations under conditions of actuator degradation, making them suitable for real-time applications where traditional analytical models fall short. These findings offer valuable insights for applications requiring stabilized forces and consistent actuation performance in the presence of material fatigue.
- 1 October 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (10) , 105017
Open AccessFatigue-aware force estimation for NiTi SMA actuators using LSTM recurrent networks
This study focuses on the force estimation of NiTi shape memory alloy (SMA) actuators, particularly addressing the challenges posed by material fatigue and force degradation over repeated actuation cycles. Traditional modeling approaches for SMAs, which typically include constitutive, phase transformation, and heat transfer sub-models, often fail to account for these degradation phenomena, leading to inaccuracies in long-term predictions. To overcome these limitations, we developed and implemented multivariate long short-term memory (LSTM) recurrent neural networks for accurate force estimation using measured parameters such as electrical power (current, voltage), strain, and temperature. An extensive experimental setup was designed to cyclically and electrothermally (Joule heating) activate the SMA actuators at varying strain levels, and the degradation in force production was quantified, with a reduction of up to 20.62% observed after 1000 cycles. The study introduced both single-stage and two-stage LSTM architectures, with the SLF model, which incorporates historical force data along with other measurements, achieving the highest accuracy (RMSE of 0.003 N). More sensor-limited and deployment-oriented variants also performed well: SLWF and SLWTF achieved RMSEs of 0.089 N and 0.110 N, respectively, and the two-stage MTSL (with learned temperature as a hidden state) achieved 0.096 N. The proposed LSTM-based models demonstrated their efficacy in providing reliable force estimations under conditions of actuator degradation, making them suitable for real-time applications where traditional analytical models fall short. These findings offer valuable insights for applications requiring stabilized forces and consistent actuation performance in the presence of material fatigue.
- 30 April 2025
- Published by Taylor & Francis in The Design Journal
- Vol. 29 (1) , 138-157
Haptic perception interaction effects between vibrotactile and compressive stimuli in wearable devices
- 30 April 2025
- Published by Taylor & Francis in The Design Journal
- Vol. 29 (1) , 138-157
Haptic perception interaction effects between vibrotactile and compressive stimuli in wearable devices
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13766-13776
Find the Gap: Multiband, Remote Measurement System to Quantify the Fit of Wearable Systems
We propose a technique for remotely measuring the gap between an external wearable device/clothing surface and the underlying (visually obstructed) body surface – which we refer to as the garment-body ’air gap’ – that commonly occurs in positive ease garments (i.e., garments that are larger in dimension than the underlying body dimension). To achieve this, we developed a triple-frequency band remote measurement system based on a 77-81 GHz FMCW radar, a 40kHz ultrasound sensor, and an infrared 344 GHz proximity sensor. When used synergistically, these sensors allow for remote measurement of the uniaxial distances to multiple layered surfaces simultaneously. To validate this approach, a test setup was developed to mount multiple surfaces at variable distances from the sensor suite. The sensor suite, when activated, can provide measurements at different configurations and distances from 3-60 cm. To provide a single measurement for the infrared/ultrasonic sensors, a logistic regression-based model was utilized, reducing the surface estimation error (RMSE) from 1.610 mm and 4.728 mm for the ultrasonic and infrared sensors, respectively, to 0.41 mm. Results show that the current first-generation multi-sensor system is able to find the air gap between a fabric surface and an underlying body-like surface with an accuracy of 2.6 mm (measured in RMSE). The developed system shows potential to allow non-invasive assessment of functional garments such as hazmat suits, PPE, space suits, and everyday clothing, offering valuable wearer interaction insights without relying on post-hoc simulations or physical sensors, enabling better design and evaluation of garments.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13766-13776
Find the Gap: Multiband, Remote Measurement System to Quantify the Fit of Wearable Systems
We propose a technique for remotely measuring the gap between an external wearable device/clothing surface and the underlying (visually obstructed) body surface – which we refer to as the garment-body ’air gap’ – that commonly occurs in positive ease garments (i.e., garments that are larger in dimension than the underlying body dimension). To achieve this, we developed a triple-frequency band remote measurement system based on a 77-81 GHz FMCW radar, a 40kHz ultrasound sensor, and an infrared 344 GHz proximity sensor. When used synergistically, these sensors allow for remote measurement of the uniaxial distances to multiple layered surfaces simultaneously. To validate this approach, a test setup was developed to mount multiple surfaces at variable distances from the sensor suite. The sensor suite, when activated, can provide measurements at different configurations and distances from 3-60 cm. To provide a single measurement for the infrared/ultrasonic sensors, a logistic regression-based model was utilized, reducing the surface estimation error (RMSE) from 1.610 mm and 4.728 mm for the ultrasonic and infrared sensors, respectively, to 0.41 mm. Results show that the current first-generation multi-sensor system is able to find the air gap between a fabric surface and an underlying body-like surface with an accuracy of 2.6 mm (measured in RMSE). The developed system shows potential to allow non-invasive assessment of functional garments such as hazmat suits, PPE, space suits, and everyday clothing, offering valuable wearer interaction insights without relying on post-hoc simulations or physical sensors, enabling better design and evaluation of garments.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 167-170
Quantifying Fit of Wearable Systems With a Multi-Band, Remote Measurement System
Garment fit is critical in wearable systems and functional clothing, including masks and other personal protective equipment (PPE), and yet no methods exist that can accurately and in real-time quantify their fit characteristics of non-translucent or non-form fitting garments. We propose a technique for remotely measuring the gap between an external wearable device or clothing surface and the underlying, visually-obstructed body surface - which we refer to as the garment-body "air gap" - that commonly occurs in positive ease garments (i.e., garments that are larger in dimension than the underlying body dimension). To do this, we developed a triple frequency band remote measurement system that is based on a millimeter wave radar, an ultrasound sensor, and an infrared distance sensor, which when used synergistically allows for remote measurement of the uniaxial distances to multiple layered surfaces simultaneously. Here this novel, first-generation system is tested and evaluated for the purpose of measuring garment fit.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 167-170
Open AccessQuantifying Fit of Wearable Systems With a Multi-Band, Remote Measurement System
Garment fit is critical in wearable systems and functional clothing, including masks and other personal protective equipment (PPE), and yet no methods exist that can accurately and in real-time quantify their fit characteristics of non-translucent or non-form fitting garments. We propose a technique for remotely measuring the gap between an external wearable device or clothing surface and the underlying, visually-obstructed body surface - which we refer to as the garment-body "air gap" - that commonly occurs in positive ease garments (i.e., garments that are larger in dimension than the underlying body dimension). To do this, we developed a triple frequency band remote measurement system that is based on a millimeter wave radar, an ultrasound sensor, and an infrared distance sensor, which when used synergistically allows for remote measurement of the uniaxial distances to multiple layered surfaces simultaneously. Here this novel, first-generation system is tested and evaluated for the purpose of measuring garment fit.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 342-346
Self-Tightening and Self-Fastening Belts and Shoes: Shape Memory Adaptive Apparel to Assist Individuals with Physical Limitations
People with physical disabilities face significant challenges in basic activities like dressing and undressing. The CDC reports that 3.6% of U.S. adults have self-care disabilities impacting dressing or bathing. Adaptive clothing, designed to facilitate dressing, includes features such as zip-off sleeves, Velcro shoes, and side-opening pants, which enhance autonomy and quality of life. Current adaptive shoes primarily use Velcro straps and wide openings with zippers. We seek to expand the adaptive clothing solution space by exploring garment-based soft robotics, such as shape memory alloy (SMA) springs, to offer advanced solutions. In this study, we developed and tested self-tightening and self-fastening belts and shoes using SMA actuators as tightening mechanisms and both hook-and-eye and electromagnetic components as fastening solutions, to improve accessibility and independence for individuals with physical limitations.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 342-346
Open AccessSelf-Tightening and Self-Fastening Belts and Shoes: Shape Memory Adaptive Apparel to Assist Individuals with Physical Limitations
People with physical disabilities face significant challenges in basic activities like dressing and undressing. The CDC reports that 3.6% of U.S. adults have self-care disabilities impacting dressing or bathing. Adaptive clothing, designed to facilitate dressing, includes features such as zip-off sleeves, Velcro shoes, and side-opening pants, which enhance autonomy and quality of life. Current adaptive shoes primarily use Velcro straps and wide openings with zippers. We seek to expand the adaptive clothing solution space by exploring garment-based soft robotics, such as shape memory alloy (SMA) springs, to offer advanced solutions. In this study, we developed and tested self-tightening and self-fastening belts and shoes using SMA actuators as tightening mechanisms and both hook-and-eye and electromagnetic components as fastening solutions, to improve accessibility and independence for individuals with physical limitations.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 71-81
Functional Now, Wearable Later: Examining the Design Practices of Wearable Technologists
Making a body-worn device wearable is a deceptively difficult challenge: it is not enough to make a functional device and simply put it on the body; it must also work with the wearer to create a positive body-product relationship. In order for a body-mounted device to achieve true wearability, proper attention must also be paid to a multitude of additional questions, including things like device size, mass, rigidity, comfort, aesthetics, and other critical design criteria above and beyond raw functionality. This paper reviews papers from the International Symposium on Wearable Computing (ISWC) and the Journal of Interactive, Mobile, Wearable and Ubiquitous Technologies (IMWUT) to understand the extent to which these professional communities acknowledge and incorporate fundamental questions of wearability into their work. The results found that while wearability is relatively present in the literature (84.44% of ISWC papers, 74.54% of IMWUT papers), there are many papers that fail to address wearability with the appropriate scientific rigor assuming they do address wearability at all. These results demonstrate the need for the wearables community to recognize the functional importance of wearability and its necessity to the design process.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 71-81
Open AccessFunctional Now, Wearable Later: Examining the Design Practices of Wearable Technologists
Making a body-worn device wearable is a deceptively difficult challenge: it is not enough to make a functional device and simply put it on the body; it must also work with the wearer to create a positive body-product relationship. In order for a body-mounted device to achieve true wearability, proper attention must also be paid to a multitude of additional questions, including things like device size, mass, rigidity, comfort, aesthetics, and other critical design criteria above and beyond raw functionality. This paper reviews papers from the International Symposium on Wearable Computing (ISWC) and the Journal of Interactive, Mobile, Wearable and Ubiquitous Technologies (IMWUT) to understand the extent to which these professional communities acknowledge and incorporate fundamental questions of wearability into their work. The results found that while wearability is relatively present in the literature (84.44% of ISWC papers, 74.54% of IMWUT papers), there are many papers that fail to address wearability with the appropriate scientific rigor assuming they do address wearability at all. These results demonstrate the need for the wearables community to recognize the functional importance of wearability and its necessity to the design process.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 323-327
Soft Ro-bra-tics: Adaptive Bra Design Using Integrated Shape Memory Materials
Garment-based soft robotics is an emerging domain which seeks to integrate compliant mechanical actuators into textile/clothing form factors. There exists a significant opportunity to develop and deploy these garment-based technologies to overcome accessibility challenges in everyday clothing, providing a suite of adaptive solutions that can support and assist with the daily challenge of tightening/loosening or fastening/unfastening a garment. In this paper, we present two embodiments of adaptive bras with embedded shape memory materials to provide robotically-assisted adaptive / customizable fit - one embodiment is designed for individuals with dexterity limitations that are typical in conditions such as arthritis, and another embodiment is designed to be fully usable with one hand. This approach, which we define as 'Soft Ro-bra-tics', represents a novel solution to overcome bra-related accessibility issues.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 323-327
Open AccessSoft Ro-bra-tics: Adaptive Bra Design Using Integrated Shape Memory Materials
Garment-based soft robotics is an emerging domain which seeks to integrate compliant mechanical actuators into textile/clothing form factors. There exists a significant opportunity to develop and deploy these garment-based technologies to overcome accessibility challenges in everyday clothing, providing a suite of adaptive solutions that can support and assist with the daily challenge of tightening/loosening or fastening/unfastening a garment. In this paper, we present two embodiments of adaptive bras with embedded shape memory materials to provide robotically-assisted adaptive / customizable fit - one embodiment is designed for individuals with dexterity limitations that are typical in conditions such as arthritis, and another embodiment is designed to be fully usable with one hand. This approach, which we define as 'Soft Ro-bra-tics', represents a novel solution to overcome bra-related accessibility issues.
- 21 May 2024
- Published by ASME International in Journal of Medical Devices
- Vol. 18 (2) , 1-33
Usability and Performance Comparison of Active Shape Memory and Passive Stockings for Medical Compression
On-body compressive therapy is an essential treatment for a variety of health conditions. Traditional compression methods like pneumatics and knit stockings offer quality compression, but present issues with user experience (donning/doffing challenges or bulk/mass issues). This paper covers two studies related to active compression stockings, which utilize knitted shape memory alloy (SMA) wire to produce dynamic compression forces on the body. When these SMA knit panels are heated with an at-home heating pad, the knit contracts and creates dynamic compression. The first study characterizes the forces produced on the body by a new iteration of an SMA knit stocking. The second study compares two versions of the SMA knit garment with a commercially available knit compression garment. The results show that SMA knit compression garments are able to produce medical grade compression on the body, but that sizing and material properties can greatly impact the forces produced. In a comparison of different compression stockings, the user experience of the SMA compression garment was preferred over the alternative garments. Overall, the potential of SMA knit compression is further highlighted, with a clear need for further development to ensure consistent medical grade compression.
- 21 May 2024
- Published by ASME International in Journal of Medical Devices
- Vol. 18 (2) , 1-33
Usability and Performance Comparison of Active Shape Memory and Passive Stockings for Medical Compression
On-body compressive therapy is an essential treatment for a variety of health conditions. Traditional compression methods like pneumatics and knit stockings offer quality compression, but present issues with user experience (donning/doffing challenges or bulk/mass issues). This paper covers two studies related to active compression stockings, which utilize knitted shape memory alloy (SMA) wire to produce dynamic compression forces on the body. When these SMA knit panels are heated with an at-home heating pad, the knit contracts and creates dynamic compression. The first study characterizes the forces produced on the body by a new iteration of an SMA knit stocking. The second study compares two versions of the SMA knit garment with a commercially available knit compression garment. The results show that SMA knit compression garments are able to produce medical grade compression on the body, but that sizing and material properties can greatly impact the forces produced. In a comparison of different compression stockings, the user experience of the SMA compression garment was preferred over the alternative garments. Overall, the potential of SMA knit compression is further highlighted, with a clear need for further development to ensure consistent medical grade compression.
- 6 November 2023
- Published by Springer Nature
- p. 1-16
Mechanical Counter-Pressure