Serdal Ayhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Serdal Ayhan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Akanksha Bhutani
Institute of Radio Frequency Engineering and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
4 shared publications- Mario Pauli
Institute of Radio Frequency Engineering and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
3 shared publications Steffen Scherr
Institute of Radio Frequency Engineering and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
3 shared publications- Thomas Zwick
Karlsruhe Institute of Technology
3 shared publications Benjamin Gottel
Institute of Radio Frequency Engineering and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publicationsMario Pauli
Institute of Radio Frequency Engineering and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications
Latest Publications
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (10) , 3640-3647
Influence of Radar Targets on the Accuracy of FMCW Radar Distance Measurements
Distance measurement tasks in micromachine tools need to be performed with micrometer accuracy. For such tasks, frequency-modulated continuous-wave (FMCW) radars with a combination of frequency and phase evaluations are a good choice. However, the accuracy cannot be indefinitely increased as there are constraints on the target size and placement imposed by the limited space inside micromachines. This paper investigates the influence of target geometry and position on the accuracy of its range estimation using a W-band FMCW radar with a bandwidth of 25 GHz. A relation between target geometry and accuracy is established through the Cramér-Rao lower bound (CRLB). Based on the measurements of different targets, an optimal shape and size is proposed, which provides an average accuracy in the single digit micrometer range. Furthermore, the influence of different bandwidths on the accuracy is investigated. It is also demonstrated how the CRLB can be used to optimize the size of a target, when a certain accuracy is needed. In addition, antenna field regions are analyzed for suitable target placements. Finally, the radar system is implemented in a machine tool and measurements with accuracies in the micrometer range are carried out.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (10) , 3640-3647
Influence of Radar Targets on the Accuracy of FMCW Radar Distance Measurements
Distance measurement tasks in micromachine tools need to be performed with micrometer accuracy. For such tasks, frequency-modulated continuous-wave (FMCW) radars with a combination of frequency and phase evaluations are a good choice. However, the accuracy cannot be indefinitely increased as there are constraints on the target size and placement imposed by the limited space inside micromachines. This paper investigates the influence of target geometry and position on the accuracy of its range estimation using a W-band FMCW radar with a bandwidth of 25 GHz. A relation between target geometry and accuracy is established through the Cramér-Rao lower bound (CRLB). Based on the measurements of different targets, an optimal shape and size is proposed, which provides an average accuracy in the single digit micrometer range. Furthermore, the influence of different bandwidths on the accuracy is investigated. It is also demonstrated how the CRLB can be used to optimize the size of a target, when a certain accuracy is needed. In addition, antenna field regions are analyzed for suitable target placements. Finally, the radar system is implemented in a machine tool and measurements with accuracies in the micrometer range are carried out.
- Top Cited Papers
- 23 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (5) , 1707-1715
Miniaturized Millimeter-Wave Radar Sensor for High-Accuracy Applications
A highly miniaturized and commercially available millimeter wave (mmw) radar sensor working in the frequency range between 121 and 127 GHz is presented in this paper. It can be used for distance measurements with an accuracy in the singledigit micrometer range. The sensor is based on the frequency modulated continuous wave (CW) radar principle; however, CW measurements are also possible due to its versatile design. An overview of the existing mmw radar sensors is given and the integrated radar sensor is shown in detail. The radio frequency part of the radar, which is implemented in SiGe technology, is described followed by the packaging concept. The radar circuitry on chip as well as the external antennas is completely integrated into an 8 mm × 8 mm quad flat no leads package that is mounted on a low-cost baseband board. The packaging concept and the complete baseband hardware are explained in detail. A two-step approach is used for the radar signal evaluation: a coarse determination of the target position by the evaluation of the beat frequency combined with an additional determination of the phase of the signal. This leads to an accuracy within a single-digit micrometer range. The measurement results prove that an accuracy of better than ±6 μm can be achieved with the sensor over a measurement distance of 35 mm.
- 23 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (5) , 1707-1715
Top Cited PapersMiniaturized Millimeter-Wave Radar Sensor for High-Accuracy Applications
A highly miniaturized and commercially available millimeter wave (mmw) radar sensor working in the frequency range between 121 and 127 GHz is presented in this paper. It can be used for distance measurements with an accuracy in the singledigit micrometer range. The sensor is based on the frequency modulated continuous wave (CW) radar principle; however, CW measurements are also possible due to its versatile design. An overview of the existing mmw radar sensors is given and the integrated radar sensor is shown in detail. The radio frequency part of the radar, which is implemented in SiGe technology, is described followed by the packaging concept. The radar circuitry on chip as well as the external antennas is completely integrated into an 8 mm × 8 mm quad flat no leads package that is mounted on a low-cost baseband board. The packaging concept and the complete baseband hardware are explained in detail. A two-step approach is used for the radar signal evaluation: a coarse determination of the target position by the evaluation of the beat frequency combined with an additional determination of the phase of the signal. This leads to an accuracy within a single-digit micrometer range. The measurement results prove that an accuracy of better than ±6 μm can be achieved with the sensor over a measurement distance of 35 mm.
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 55 (2) , 854-861
Millimeter-Wave Radar Sensor for Snow Height Measurements
A small and lightweight frequency-modulated continuous-wave (FMCW) radar system is used for the determination of snow height by measuring the distance to the snow surface from a platform. The measurements have been performed at the Centre des Études de la Neige (Col de Porte), which is located near Grenoble in the French Alps. It is shown that the FMCW radar at millimeter-wave frequencies is an extremely promising approach for distance measurements to snow surfaces, e.g., in the mountains or in an Arctic environment. The characteristics of the radar sensor are described in detail. The relevant accuracy to measure the distance to a snow layer is shown at different heights and over an extended time duration. A dedicated laser snow telemeter is used as reference. In addition, the reflection from different types of snow is shown.
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 55 (2) , 854-861
Millimeter-Wave Radar Sensor for Snow Height Measurements
A small and lightweight frequency-modulated continuous-wave (FMCW) radar system is used for the determination of snow height by measuring the distance to the snow surface from a platform. The measurements have been performed at the Centre des Études de la Neige (Col de Porte), which is located near Grenoble in the French Alps. It is shown that the FMCW radar at millimeter-wave frequencies is an extremely promising approach for distance measurements to snow surfaces, e.g., in the mountains or in an Arctic environment. The characteristics of the radar sensor are described in detail. The relevant accuracy to measure the distance to a snow layer is shown at different heights and over an extended time duration. A dedicated laser snow telemeter is used as reference. In addition, the reflection from different types of snow is shown.
- Top Cited Papers
- 30 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (10) , 3290-3301
Impact of Frequency Ramp Nonlinearity, Phase Noise, and SNR on FMCW Radar Accuracy
One of the main disturbances in a frequency-modulated continuous wave radar system for range measurement is nonlinearity in the frequency ramp. The intermediate frequency (IF) signal and consequently the target range accuracy are dependent on the type of the nonlinearity present in the frequency ramp. Moreover, the type of frequency ramp nonlinearity cannot be directly specified, which makes the problem even more challenging. In this paper, the frequency ramp nonlinearity is investigated with the modified short-time Fourier transform method by using the short-time Chirp-Z transform method with high accuracy. The random and periodic nonlinearities are characterized and their sources are identified as phase noise and spurious. These types of frequency deviations are intentionally increased, and their influence on the linearity and the IF-signal is investigated. The dependence of target range estimation accuracy on the frequency ramp nonlinearity, phase noise, spurious, and signal-to-noise ratio in the IF-signal are described analytically and are verified on the basis of measurements.
- 30 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (10) , 3290-3301
Top Cited PapersImpact of Frequency Ramp Nonlinearity, Phase Noise, and SNR on FMCW Radar Accuracy
One of the main disturbances in a frequency-modulated continuous wave radar system for range measurement is nonlinearity in the frequency ramp. The intermediate frequency (IF) signal and consequently the target range accuracy are dependent on the type of the nonlinearity present in the frequency ramp. Moreover, the type of frequency ramp nonlinearity cannot be directly specified, which makes the problem even more challenging. In this paper, the frequency ramp nonlinearity is investigated with the modified short-time Fourier transform method by using the short-time Chirp-Z transform method with high accuracy. The random and periodic nonlinearities are characterized and their sources are identified as phase noise and spurious. These types of frequency deviations are intentionally increased, and their influence on the linearity and the IF-signal is investigated. The dependence of target range estimation accuracy on the frequency ramp nonlinearity, phase noise, spurious, and signal-to-noise ratio in the IF-signal are described analytically and are verified on the basis of measurements.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Radar sensor for waveguide based distance measurements in machine tool components
High-accuracy measurement systems are in high demand for industrial applications. Especially in machine tools, range measurement options close to the stage position are required. The main challenge of the measurement technique is the integration into the machine tool concept. In this paper, a novel measurement principle based on radar and on guided waves is presented for these applications, to achieve a high accuracy by avoiding disturbing reflections from the environment.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Radar sensor for waveguide based distance measurements in machine tool components
High-accuracy measurement systems are in high demand for industrial applications. Especially in machine tools, range measurement options close to the stage position are required. The main challenge of the measurement technique is the integration into the machine tool concept. In this paper, a novel measurement principle based on radar and on guided waves is presented for these applications, to achieve a high accuracy by avoiding disturbing reflections from the environment.