Hadrien Courtecuisse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hadrien Courtecuisse has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Christian Duriez
Univ. Lille, Inria, CNRS, Centrale Lille, UMR 9189 CRIStAL, Lille, France
2 shared publications - Jean-François Witz
Centrale Lille
2 shared publications - Pauline Lecomte-Grosbras
Centrale Lille
2 shared publications - Zhifan Jiang
Children’s National Hospital
2 shared publications - Abbas Samani
School of Biomedical Engineering, Western University, London, ON N6A 3K7, Canada
1 shared publication Annie Morch
1 shared publication
Latest Publications
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Nouvelles architectures parallèles pour simulations interactives médicales
Cette thèse apporte des solutions pour exploiter efficacement les nouvelles architectures hautement parallèles, dans le contexte des simulations d'objets déformables en temps réel. Les premières contributions de ce document, se concentrent sur le calcul de la déformation des objets. Pour cela nous proposerons des solutions de parallélisations de solveurs linéaires, couplées à des techniques de preconditionnement asynchrone. Le second ensemble de contributions, repose sur le processeur graphique pour produire une nouvelle méthode de détection des collisions, basée sur le volume d'intersection entre les objets déformables.Enfin les derniers travaux apportent des solutions pour produire une réponse précise aux contacts, et compatible avec le temps réel. Nous aborderons notamment les problèmes liés à la découpe des organes, et à la prise en compte du couplage mécanique entre les contacts. Pour terminer, nous illustrerons nos contributions dans un ensemble d’applications médicales, qui tirent parti des contributions de ce document.
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Nouvelles architectures parallèles pour simulations interactives médicales
Cette thèse apporte des solutions pour exploiter efficacement les nouvelles architectures hautement parallèles, dans le contexte des simulations d'objets déformables en temps réel. Les premières contributions de ce document, se concentrent sur le calcul de la déformation des objets. Pour cela nous proposerons des solutions de parallélisations de solveurs linéaires, couplées à des techniques de preconditionnement asynchrone. Le second ensemble de contributions, repose sur le processeur graphique pour produire une nouvelle méthode de détection des collisions, basée sur le volume d'intersection entre les objets déformables.Enfin les derniers travaux apportent des solutions pour produire une réponse précise aux contacts, et compatible avec le temps réel. Nous aborderons notamment les problèmes liés à la découpe des organes, et à la prise en compte du couplage mécanique entre les contacts. Pour terminer, nous illustrerons nos contributions dans un ensemble d’applications médicales, qui tirent parti des contributions de ce document.
- Open Access
An efficient implicit constraint resolution scheme for interactive FE simulations
This paper presents a novel implicit scheme for the constraint resolution in real-time finite element simulations in the presence of contact and friction. Instead of using the standard motion correction scheme, we propose an iterative method where the constraint forces are corrected in Newton iterations. In this scheme, we are able to update the constraint directions recursively, providing more accurate contact and friction response. However, updating the constraint matrices leads to massive computation costs. To address the issue, we propose separating the constraint direction and geometrical mapping in the contact Jacobian matrix and reformulating the schur-complement of the system matrix. When combined with GPU-based parallelization, the reformulation provides a very efficient updating process for the constraint matrices in the recursive corrective motion scheme. Our method enables the possibility to handle the inconsistency of constraint directions at the beginning and the end of time steps. At the same time, the resolution process is kept as efficient as possible. We evaluate the performance of our fast-updating scheme in a contact simulation and compare it with the standard updating scheme.
Open AccessAn efficient implicit constraint resolution scheme for interactive FE simulations
This paper presents a novel implicit scheme for the constraint resolution in real-time finite element simulations in the presence of contact and friction. Instead of using the standard motion correction scheme, we propose an iterative method where the constraint forces are corrected in Newton iterations. In this scheme, we are able to update the constraint directions recursively, providing more accurate contact and friction response. However, updating the constraint matrices leads to massive computation costs. To address the issue, we propose separating the constraint direction and geometrical mapping in the contact Jacobian matrix and reformulating the schur-complement of the system matrix. When combined with GPU-based parallelization, the reformulation provides a very efficient updating process for the constraint matrices in the recursive corrective motion scheme. Our method enables the possibility to handle the inconsistency of constraint directions at the beginning and the end of time steps. At the same time, the resolution process is kept as efficient as possible. We evaluate the performance of our fast-updating scheme in a contact simulation and compare it with the standard updating scheme.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 4853-4860
Planning of Soft-Rigid Hybrid Arms in Contact With Compliant Environment: Application to the Transrectal Biopsy of the Prostate
In this study, a rigid robot is hybridized with a soft part to improve its properties of relative positioning and safe interaction. While the design of the device is quite simple, the kinematics, on the other hand, becomes complex. Pre-operative planning of such a robot is a challenge that is faced in this letter. The clinical context is the automation of transrectal prostate biopsy: a robot is connected to a thin ultrasound (US) probe instrumented with a needle through a flexible silicone part. The procedure consists of: moving the probe near the prostate through the rectum, aligning the probe with identified lesions in the prostate, and shooting the needle to collect tissue samples. In this letter we demonstrate in simulation the feasibility of our methods to solve the planning of the entire procedure. The approach we propose is based on numerical models of both robot and soft tissues, using the Finite Element Method (FEM) to model the soft parts, and a mapping mechanism to propagate the forces and displacements between the soft and rigid models. Finally, we extend the optimization algorithm proposed in previous work for the relative positioning of the hybrid robot on targets in the prostate, as it interacts with the soft tissues. With this formulation we can also set an upper limit to the force the robot is applying on its surroundings, which is particularly critical for the application we study in this letter.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 4853-4860
Planning of Soft-Rigid Hybrid Arms in Contact With Compliant Environment: Application to the Transrectal Biopsy of the Prostate
In this study, a rigid robot is hybridized with a soft part to improve its properties of relative positioning and safe interaction. While the design of the device is quite simple, the kinematics, on the other hand, becomes complex. Pre-operative planning of such a robot is a challenge that is faced in this letter. The clinical context is the automation of transrectal prostate biopsy: a robot is connected to a thin ultrasound (US) probe instrumented with a needle through a flexible silicone part. The procedure consists of: moving the probe near the prostate through the rectum, aligning the probe with identified lesions in the prostate, and shooting the needle to collect tissue samples. In this letter we demonstrate in simulation the feasibility of our methods to solve the planning of the entire procedure. The approach we propose is based on numerical models of both robot and soft tissues, using the Finite Element Method (FEM) to model the soft parts, and a mapping mechanism to propagate the forces and displacements between the soft and rigid models. Finally, we extend the optimization algorithm proposed in previous work for the relative positioning of the hybrid robot on targets in the prostate, as it interacts with the soft tissues. With this formulation we can also set an upper limit to the force the robot is applying on its surroundings, which is particularly critical for the application we study in this letter.
Three‐dimensional physics‐based registration of pelvic system using 2D dynamic magnetic resonance imaging slices
This paper introduces a method for dynamic 3D registration of female pelvic organs using 2D dynamic magnetic‐resonance images (MRIs). The aim is to provide a better knowledge and understanding of pathologies such as prolapsus or abnormal mobility of tissues. 2D dynamic MRI sequences are commonly used in nowadays clinical routines in order to evaluate the dynamic of organs, but due to the limited view, subjectivity related to human perception cannot be avoided in the diagnoses. A novel method for 2D/3D registration is proposed combining 3D finite element models with a priori knowledge of boundary conditions, in order to provide a 3D extrapolation of the dynamic of the organs observed in a single 2D MRI slice. The method is applied to the four main structures of the female pelvic floor (bladder, vagina, uterus and rectum), providing a full 3D visualisation of the organs' displacements. The methodology is evaluated with two patient‐specific data sets of volunteers presenting no pelvic pathology, and a sensitivity study is performed using synthetic data. The resulting simulations provide an estimation of the dynamic 3D shape of the organs facilitating diagnosis compared with 2D sequences. Moreover, the method follows a protocol compatible with current clinical constraints presenting this way potential short term medical applications.
Three‐dimensional physics‐based registration of pelvic system using 2D dynamic magnetic resonance imaging slices
This paper introduces a method for dynamic 3D registration of female pelvic organs using 2D dynamic magnetic‐resonance images (MRIs). The aim is to provide a better knowledge and understanding of pathologies such as prolapsus or abnormal mobility of tissues. 2D dynamic MRI sequences are commonly used in nowadays clinical routines in order to evaluate the dynamic of organs, but due to the limited view, subjectivity related to human perception cannot be avoided in the diagnoses. A novel method for 2D/3D registration is proposed combining 3D finite element models with a priori knowledge of boundary conditions, in order to provide a 3D extrapolation of the dynamic of the organs observed in a single 2D MRI slice. The method is applied to the four main structures of the female pelvic floor (bladder, vagina, uterus and rectum), providing a full 3D visualisation of the organs' displacements. The methodology is evaluated with two patient‐specific data sets of volunteers presenting no pelvic pathology, and a sensitivity study is performed using synthetic data. The resulting simulations provide an estimation of the dynamic 3D shape of the organs facilitating diagnosis compared with 2D sequences. Moreover, the method follows a protocol compatible with current clinical constraints presenting this way potential short term medical applications.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (3) , 697-708
Robotic Insertion of Flexible Needle in Deformable Structures Using Inverse Finite-Element Simulation
This paper introduces a new approach for the control of a robotic system interacting with deformable structures. The method is applied to needle insertion procedures, which are among the least invasive surgical approaches to access deep internal structures with sometimes poor access conditions. Yet, during the insertion both tissues and needles deform resulting in a displacement of targets identified at the planning step and significantly raising the technical difficulty of these approaches. Robotic assistance may offer new possibilities to enforce the accuracy of the needle’s positioning, but the deformation of tissues remains an open problem. In this paper, we propose a numerical approach where finite-element (FE) models are used in a close-control robotic loop. We introduce a complete forward simulation of deformable structures (needle and environment) and constraint-based interaction models allowing for the simulation of needle insertion and complex nonlinear phenomena (friction, puncture, and insertion) at a high frequency. For the control, we numerically derive the so-called Jacobian of the Simulation using an inverse method. The most original aspect of this paper lies in the fact that inverse steps are performed in constraints space, allowing this way for fast estimation of the Jacobian (i.e., between 40 and 100 Hz). The method is validated both numerically and experimentally using a flexible needle inserted inside a deformable foam. We show that the robot is able to follow a given trajectory, defined during the planning step, taking into account any occurring deformation of both the needle and the foam during the insertion; without any need for tracking the needle neither the target nor the trajectory.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (3) , 697-708
Robotic Insertion of Flexible Needle in Deformable Structures Using Inverse Finite-Element Simulation
This paper introduces a new approach for the control of a robotic system interacting with deformable structures. The method is applied to needle insertion procedures, which are among the least invasive surgical approaches to access deep internal structures with sometimes poor access conditions. Yet, during the insertion both tissues and needles deform resulting in a displacement of targets identified at the planning step and significantly raising the technical difficulty of these approaches. Robotic assistance may offer new possibilities to enforce the accuracy of the needle’s positioning, but the deformation of tissues remains an open problem. In this paper, we propose a numerical approach where finite-element (FE) models are used in a close-control robotic loop. We introduce a complete forward simulation of deformable structures (needle and environment) and constraint-based interaction models allowing for the simulation of needle insertion and complex nonlinear phenomena (friction, puncture, and insertion) at a high frequency. For the control, we numerically derive the so-called Jacobian of the Simulation using an inverse method. The most original aspect of this paper lies in the fact that inverse steps are performed in constraints space, allowing this way for fast estimation of the Jacobian (i.e., between 40 and 100 Hz). The method is validated both numerically and experimentally using a flexible needle inserted inside a deformable foam. We show that the robot is able to follow a given trajectory, defined during the planning step, taking into account any occurring deformation of both the needle and the foam during the insertion; without any need for tracking the needle neither the target nor the trajectory.
- Open Access
- 1 February 2014
- Published by Elsevier in Medical Image Analysis
- Vol. 18 (2) , 394-410
Real-time simulation of contact and cutting of heterogeneous soft-tissues
- 1 February 2014
- Published by Elsevier in Medical Image Analysis
- Vol. 18 (2) , 394-410
Open AccessReal-time simulation of contact and cutting of heterogeneous soft-tissues