Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dong-Ok Won has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A framework for earthquake seismic signal classification with the aid of hybrid feature selection schemes and robust machine learning models

    by Sunil Kumar Prabhakar, Dong-Ok Won

    One of the most catastrophic natural events is an earthquake, which causes huge destruction to humanity, thus necessitating the use of seismic signals to detect and classify them. Many machine learning models have been proposed that act as automated earthquake detection and classification methods by using seismic signals. However, the proposed method in this study utilizes the concept of learning-based feature extraction from seismic signals such as graph-embedding learning (GEL), through low-rank representation (LRR) and robust neighborhood embedding (RNE). In a parallel approach, statistical feature extraction approaches such as cross-correlation function (CCF) and partial CCF (PCCF) are implemented with multivariate variational mode decomposition (MVMD). Kriging model-based feature selection and K-best features selection techniques are then utilized, and the features are finally classified with the standard machine learning classifiers. This combined approach is considered a novel technique. The second technique proposed in this study utilizes the concept of reinforcement learning (RL) Bayesian networks (BNs) with the AdaBoost-based Elman neural network (ENN) model known altogether as the “RL–BN–AENN model” with extracted and selected features. Third, a differential evolution (DE)-based Bayesian classifier is proposed, the DE-BC model, with extracted and selected features. Finally, the concept of linear discriminant analysis (LDA) is utilized with a fuzzy weighted relevance vector machine, the LDA–FW–relevance vector machine (RVM) model, and the same LDA is utilized with a fruit fly optimization algorithm (FFOA) and support vector machine (SVM) concept, the LDA–FFOA–SVM model, which is utilized with extracted and selected features. The results show that a high classification accuracy of 98.89% is obtained for the two-class classification problem when LLR with Kriging model feature selection and the AdaBoost–ENN classifier are implemented. A high classification accuracy of 92.95% is obtained for the three-class classification problem when PCCF with MVMD and Kriging model feature selection classified with the LDA–FFOA–SVM classifier is implemented.

  • Open Access

    A Structured Comparison of the Coalition for Health AI Responsible AI Guide and South Korea’s Trustworthy AI Guideline for Health Care AI Assurance: Comparative Framework Analysis

    by Trevor Vigeant, Aidan Tam, Qiming Shi, Jeroan Allison, MinJin Kim, Jin-Ah Sim, Dong Ok Won, DongSoo Shin, David M McManus, Jae Jun Lee, et al.

    Background: Trustworthy artificial intelligence (AI) in health care requires assurance frameworks that translate ethical principles into measurable governance and evaluation practices. While a growing number of AI assurance frameworks have been proposed, they differ substantially in governance structure, institutional embedding, and implementation mechanisms, reflecting differences in intended purpose and use. To date, few studies have applied standardized, rubric-based evaluation criteria to systematically compare how assurance instruments with different institutional origins operationalize ethical principles across the AI lifecycle. Objective: This study aimed to develop and apply a structured, rubric-based evaluation instrument to compare 2 health care AI assurance instruments, including the Coalition for Health AI (CHAI) responsible AI guide, a voluntary consortium-based instrument, and South Korea’s Trustworthy AI guideline, a government-issued instrument. Methods: A 7-dimension evaluation rubric was developed based on a synthesis of established international AI assurance and governance instruments. The rubric covered core principles, AI lifecycle coverage, governance context, stakeholder breadth, operational maturity, instrument design and tools, and public accessibility. Seven independent evaluators with expertise in health care AI governance assessed each instrument using a 5-point ordinal rating scale (1=absent-5=comprehensive). Each evaluator independently scored the materials using a standardized rubric. Discrepancies were resolved through structured consensus discussions, with reference to rubric definitions and source documents. Final scores were determined based on documented evidence, requiring full consensus rather than averaging. Interrater reliability was assessed using Fleiss kappa. Results: Both instruments demonstrated strong alignment in core principles (CHAI: 4; Trustworthy AI Guideline: 5) and stakeholder breadth (both: 4). The government-issued Trustworthy AI Guideline exhibited broader AI lifecycle coverage (5 vs 4), a more formalized governance context (5 vs 3), and higher operational maturity (4 vs 2), reflecting stepwise oversight and formal embedded oversight mechanisms supported by legislation. In contrast, the voluntary CHAI instrument demonstrated greater emphasis on instrument design and implementation tools (4 vs 3) and higher public accessibility (5 vs 3), driven by open-access resources such as assurance standards guides and applied model cards. Interrater agreement of independent ratings was moderate to substantial (Fleiss kappa=0.47-0.64; P <.001), indicating consistent scoring patterns among evaluators. Conclusions: This comparative analysis indicates that voluntary and government-issued AI assurance instruments operationalize trustworthy AI principles in distinct but complementary ways. Voluntary instruments emphasize flexible tools and accessible implementation resources, while government-issued guidelines embed assurance functions within formal governance and oversight structures. Rather than representing competing models, these approaches address different assurance needs across the AI lifecycle. By identifying concrete areas of alignment and divergence, this study supports a more coherent comparison of assurance practices and highlights potential opportunities for alignment across documentation structures and evaluation approaches that can support safe, equitable, and scalable deployment of health care AI across diverse institutional contexts.


  • Open Access

    A Consolidated Framework for the Detection of Alzheimer’s Disease Using EEG Signals and Hybrid Models

    by Sunil Kumar Prabhakar, Dong-Ok Won

    Alzheimer’s disease (AD) is a serious neurodegenerative disorder that can severely affect behavior and thinking patterns, and is accompanied by frequent memory loss. The early diagnosis of AD is essential, as this can benefit the patient, but detecting AD is a complex process due to the nature of its associated clinical data. Electroencephalography (EEG) serves as a promising and cost-effective technique for analyzing AD-related brain activity patterns. In this work, a consolidated framework for detecting AD using EEG signals and hybrid models is proposed that uses a dataset that is available online. For the feature extraction module, five efficient techniques—Principal Component Analysis (PCA), Kernel Partial Least Squares (KPLS), Kriging Model, Isomap, and K-means clustering—are used. For feature selection, with the help of biomimetics-based concepts, three efficient algorithms are used: hybrid Cuckoo Search Optimization–Rat Swarm Optimization (CSO-RSO), Zebra Optimization (ZOA), and hybrid Gravitational Search Algorithm–Particle Swarm Optimization (GSA-PSO). Four interesting hybrid classifiers are utilized here to detect AD using EEG signals—hybrid Extreme Learning Machine–Adaboost (ELM–Adaboost), hybrid Classification and Regression Trees–Adaboost (CART–Adaboost), and hybrid weighted broad learning system-based Adaboost (HWBLSA), followed by a hybrid machine learning classification model with a soft voting technique—and, finally, these are compared with other standard machine learning classifiers. The highest classification accuracy of 98.71% is found when the Kriging Model feature extraction concept is combined with the hybrid GSA-PSO feature selection method and classified with the ELM–Adaboost classifier.


  • Open Access

    A Unified Framework for Detection of ADHD Using EEG Signals and Coherent Models

    by Sunil Kumar Prabhakar, Dong-Ok Won

    A behavioral and neuropsychological disorder that develops in young children during their early school years is called attention-deficit hyperactivity disorder (ADHD). When young children are diagnosed with ADHD, they have a tendency not to concentrate on academic and extracurricular activities. Moreover, children affected with ADHD suffer from mood swings, so it becomes quite difficult for them to establish good connections with teachers and friends. In the field of clinical research, deploying Electroencephalography (EEG) signals, a rapid and accurate diagnosis of ADHD is essential so that an effective treatment can be given to the children affected with ADHD. In this work, a unified framework is proposed for the detection of ADHD using EEG signals and some coherent models. The framework initially employs the concept of normalization of EEG signals, followed by the usage of dimensionality reduction techniques such as Local Linear Embedding (LLE), Sammon Mapping (SM) and Locally Linear Coordination (LLC). The dimensionally reduced EEG values are further clustered using four techniques such as spectral clustering, K-means clustering, Fuzzy C-means (FCM) clustering, Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN), and finally, silhouette coefficient analysis is used to analyze the clustering effectiveness. The features are then extracted from the clustered values using an Improved Wavelet Transform (IWT) and then the features are selected with four efficient techniques such as the chi-squared test, Mutual Information (MI), Mahalanobis analysis and Binary Horse Herd Optimization (BHHO) techniques. Finally, the selected values are fed into classifiers for classification with the help of ten traditional machine learning classifiers. The work is tested on a publicly available ADHD dataset and the analysis shows that the best results are obtained when the LLC dimensionality reduction is utilized with FCM clustering and IWT feature extraction, BHHO feature selection, and classified with LGBA classifier reporting a high classification accuracy of 98.12%.


  • Open Access

    Efficient Blended Models for Analysis and Detection of Neuropathic Pain from EEG Signals Using Machine Learning

    by Sunil Kumar Prabhakar, Keun-Tae Kim, Dong-Ok Won

    Due to the damage happening in the nervous system, neuropathic pain occurs and it affects the quality of life of the patient to a great extent. Therefore, some clinical evaluations are required to assess the diagnostic outcomes precisely. A lot of information about the activities of the brain is provided by Electroencephalography (EEG) signals and neuropathic pain can be assessed and classified with the aid of EEG and machine learning. In this work, two approaches are proposed in terms of efficient blended models for the classification of neuropathic pain through EEG signals. In the first blended model, once the features are extracted using Discrete Wavelet Transform (DWT), statistical features, and Fuzzy C-Means (FCM) clustering techniques, the features are selected using Grey Wolf Optimization (GWO), Feature Correlation Clustering Technique (FCCT), F-test, and Bayesian Optimization Algorithm (BOA) and it is classified with the help of three hybrid classification models like Spider Monkey Optimization-based Gradient Boosting Machine (SMO-GBM) classifier, hybrid deep kernel learning with Support Vector Machine (DKL-SVM) classifier, and CatBoost classifier. In the second blended model, once the features are extracted, the features are selected using Hybrid Feature Selection—Majority Voting System (HFS-MVS), Hybrid Salp Swarm Optimization—Particle Swarm Optimization (SSO-PSO), Pearson Correlation Coefficient (PCC), and Mutual Information (MI) and it is classified with the help of three hybrid classification models like Partial Least Squares (PLS) variant classification models combined with Kernel-based SVM, ensemble classification model with soft voting strategy, and Extreme Gradient Boosting (XGBoost) classifier. The proposed blended models are evaluated on a publicly available dataset and the best results are shown when the FCM features are selected with SSO-PSO feature selection technique and classified with Polynomial Kernel-based PLS-SVM Classifier, reporting a high classification accuracy of 92.68% in this work.


  • Open Access

    Pragmatic Models for Detection of Hypertension Using Ballistocardiograph Signals and Machine Learning

    by Sunil Kumar Prabhakar, Dong-Ok Won

    To identify hypertension, Ballistocardiograph (BCG) signals can be primarily utilized. The BCG signal must be thoroughly understood and interpreted so that its application in the classification process could become clearer and more distinct. Various unhealthy habits such as excess consumption of alcohol and tobacco, accompanied by a lack of good diet and a sedentary lifestyle, lead to hypertension. Common symptoms of hypertension include chest pain, shortness of breath, blurred vision, mood swings, frequent urination, etc. In this work, two pragmatic models are proposed for the detection of hypertension using BCG signals and machine learning models. The first model uses K-means clustering, the maximum overlap discrete wavelet transform (MODWT) and the Empirical Wavelet Transform (EWT) techniques for feature extraction, followed by the Binary Tunicate Swarm Algorithm (BTSA) and Information Gain (IG) for feature selection, as well as two efficient hybrid classifiers such as the Hybrid AdaBoost–-Maximum Uncertainty Linear Discriminant Analysis (MULDA) classifier and the Hybrid AdaBoost–Random Forest (RF) classifier for the classification of BCG signals. The second model uses Principal Component Analysis (PCA), Kernel Principal Component Analysis (KPCA) and the Random Feature Mapping (RFM) technique for feature extraction, followed by IG and the Aquila Optimization Algorithm (AOA) for feature selection, as well as two versatile hybrid classifiers such as the Hybrid AutoRegressive Integrated Moving Average (ARIMA)–AdaBoost classifier and the Time-weighted Hybrid AdaBoost–Support Vector Machine (TW-HASVM) classifier for the classification of BCG signals. The proposed methodology was tested on a publicly available BCG dataset, and the best results were obtained when the KPCA feature extraction technique was used with the AOA feature selection technique and classified using the Hybrid ARIMA–AdaBoost classifier, reporting a good classification accuracy of 96.89%.


  • Open Access

    O-CCR: oriented cervical canal region detection framework toward cervical change assessment in transvaginal ultrasound

    by Minseo Hwangbo, Yeong-Eun Jeon, Kyong-No Lee, Keun-Young Lee, Jae Jun Lee, Ga-Hyun Son, Dong-Ok Won

    The cervix undergoes morphological and structural changes during pregnancy in preparation for delivery. Assessing the progression of these changes using tr


  • Open Access

    Standard Visual and Ordinal Coronary Calcium Scoring on PET/CT: Agreement with Agatston Scoring and Prognostic Implications

    by Sehyun Pak, Hye Joo Son, Dongwoo Kim, Jung Won Moon, Yoo Na Kim, Ji Young Woo, Min-Kyung Kang, Dong-Ok Won, Suk Hyun Lee

    Background: Visual assessment of coronary artery calcium (CAC) on ungated chest CT has been described previously. However, its reliability and clinical utility remain uncertain, particularly in PET/CT studies that use low-dose, low-slice CT and are susceptible to respiratory artifacts. Methods: We retrospectively analyzed 106 patients (median age, 66 years [interquartile range, 60–75 years]; 67 men [63.2%]) who underwent PET/CT and electrocardiogram (ECG)-gated chest CT within a 90-day interval. Six readers (three radiologists and three nuclear medicine physicians) independently assessed CAC on PET/CT using a standard four-point visual scale and a 0–12 ordinal scale based solely on written instructions. Agatston scoring was also performed. Interobserver agreement and concordance with ECG-gated chest CT Agatston score categories were calculated. Major adverse cardiovascular events (MACE) were recorded over a median follow-up of 3.5 years. Results: Interobserver agreement was good for both the standard visual (κ = 0.761) and ordinal (κ = 0.779) scales. Concordance with ECG-gated CT Agatston categories was higher for standard visual (κ = 0.849) and ordinal (κ = 0.750) scoring than for PET/CT Agatston categories (κ = 0.464). Both qualitative scales tended to underestimate CAC categories compared with ECG-gated CT; however, severe CAC on PET/CT predicted MACE (hazard ratios: 4.41 standard visual; 6.59 ordinal), and the ordinal scale significantly stratified MACE-free survival (p = 0.047). Conclusions: Standard visual and ordinal CAC scoring on the ungated CT portion of PET/CT is quick, reproducible, closely mirrors ECG-gated-CT Agatston grading, and offers prognostic value for future MACE in cancer patients.


  • Open Access

    O-CCR: Oriented Cervical Canal Region Detection Framework for Biomechanical Cervical Assessment in TVUS

    by Minseo Hwangbo, Yeong-Eun Jeon, Kyong-No Lee, Keun-Young Lee, Jae Jun Lee, Ga-Hyun Son, Dong-Ok Won

    Background: The cervix undergoes biomechanical changes during pregnancy in preparation for delivery. Assessing the progression of these changes using transvaginal ultrasound (TVUS) is crucial for preterm birth prediction. However, existing methods such as cervical length have limitations in capturing subtle tissue changes. Although tissue analysis using TVUS has been explored to address these limitations, achieving consistent and reproducible results in quantitative analysis remains challenging due to high inter-observer variability and a lack of standardized region of interest (ROI) definitions. This study proposes an oriented cervical canal region (O-CCR) framework that identifies a standardized CCR with relevant sonographic features for evaluating biomechanical change. Methods: We utilized 1436 TVUS images for training, validation, and testing, with 189 additional images from a different hospital for external validation. CCR was defined to include the cervical canal and its surrounding region after aligning the IO and EO parallel to ensure anatomical consistency in the cervix. To validate the effectiveness of O-CCR in handling various orientations, we applied five oriented object detection models (Oriented R-CNN, ReDet, S\(^{2}\)A-Net, R\(^{3}\)Det, and Oriented RepPoints) and evaluated their CCR localization performance. Results: We compared the performance of five models implemented within O-CCR framework. Among them, Oriented RepPoints achieved the highest average precision (AP) of 0.981 at the intersection over union (IoU) threshold of 0.5, compared to Oriented R-CNN (0.968), S\(^{2}\)A-Net (0.962), ReDet (0.964), and R\(^{3}\)Det (0.980) on the test dataset. Notably, Oriented RepPoints demonstrated superior performance even at higher thresholds of 0.6 (0.931) and 0.7 (0.743) and the lowest average orientation error (AOE) of 9.1980 in CCR localization. Conclusions: O-CCR showed reliable performance to localize CCR despite various orientations and shapes, providing standardized regions for assessing biomechanical changes of the cervix. The consistent CCR could be applied to quantitative analysis of cervical tissue properties in future research. Ultimately, this approach could support the development of automated cervical change assessment for prenatal care.