ACAndrzej Czerwinski

Andrzej Czerwinski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrzej Czerwinski has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sensitive Metal-Semiconductor Nanothermocouple Fabricated by FIB to Investigate Laser Beams with Nanometer Spatial Resolution

    by Adam Łaszcz, Andrzej Czerwinski, Emilia Pruszyńska-Karbownik, Marek Wzorek, Dariusz Szmigiel

    The focused ion beam (FIB) technique was used to fabricate a nanothermocouple (with a 90 nm wide nanojunction) based on a metal–semiconductor (Pt–Si) structure, which showed a sensitivity up to 10 times larger (with Seebeck coefficient up to 140 µV/K) than typical metal–metal nanothermocouples. In contrast to the fabrication of nanothermocouples which requires a high-tech semiconductor manufacturing line with sophisticated fabrication techniques, environment, and advanced equipment, FIB systems are available in many research laboratories without the need for a high-tech environment, and the described processing is performed relatively quickly by a single operator. The linear response of the manufactured nanothermocouple enabled sensitive measurements even with small changes of temperature when heated with a stream of hot air. A nonlinear response of the nanothermocouple (up to 83.85 mV) was observed during the exposition to an argon-laser beam with a high optical power density (up to 17.4 Wcm−2), which was also used for the laser annealing of metal–semiconductor interfaces. The analysis of the results implies the application of such nanothermocouples, especially for the characterization of laser beams with nanometer spatial resolution. Improvements of the FIB processing should lead to an even higher Seebeck coefficient of the nanothermocouples; e.g., in case of the availability of other suitable metal sources (e.g., Cr).


  • Open Access

    Terahertz Time-Domain Spectroscopy of Graphene Nanoflakes Embedded in Polymer Matrix

    by Anton Koroliov, Genyu Chen, Kenneth M. Goodfellow, A. Nick Vamivakas, Zygmunt Staniszewski, Peter Sobolewski, Mirosława El Fray, Adam Łaszcz, Andrzej Czerwinski, Christiaan P. Richter, et al.

    The terahertz time-domain spectroscopy (THz-TDS) technique has been used to obtain transmission THz-radiation spectra of polymer nanocomposites containing a controlled amount of exfoliated graphene. Graphene nanocomposites (1 wt%) that were used in this work were based on poly(ethylene terephthalate-ethylene dilinoleate) (PET-DLA) matrix and were prepared via a kilo-scale (suitable for research and development, and prototyping) in-situ polymerization. This was followed by compression molding into 0.3-mm-thick and 0.9-mm-thick foils. Transmission electron microscopy (TEM) and Raman studies were used to confirm that the graphene nanoflakes dispersed in a polymer matrix consisted of a few-layer graphene. The THz-radiation transients were generated and detected using a low-temperature–grown GaAs photoconductive emitter and detector, both excited by 100-fs-wide, 800-nm-wavelength optical pulses, generated at a 76-MHz repetition rate by a Ti:Sapphire laser. Time-domain signals transmitted through the nitrogen, neat polymer reference, and 1-wt% graphene-polymer nanocomposite samples were recorded and subsequently converted into the spectral domain by means of a fast Fourier transformation. The spectral range of our spectrometer was up to 4 THz, and measurements were taken at room temperature in a dry nitrogen environment. We collected a family of spectra and, based on Fresnel equations, performed a numerical analysis, that allowed us to extract the THz-frequency-range refractive index and absorption coefficient and their dependences on the sample composition and graphene content. Using the Clausius-Mossotti relation, we also managed to estimate the graphene effective dielectric constant to be equal to ~7 ± 2. Finally, we extracted from our experimental data complex conductivity spectra of graphene nanocomposites and successfully fitted them to the Drude-Smith model, demonstrating that our graphene nanoflakes were isolated in their polymer matrix and exhibited highly localized electron backscattering with a femtosecond relaxation time. Our results shed new light on how the incorporation of exfoliated graphene nanoflakes modifies polymer electrical properties in the THz-frequency range. Importantly, they demonstrate that the complex conductivity analysis is a very efficient, macroscopic and non-destructive (contrary to TEM) tool for the characterization of the dispersion of a graphene nanofiller within a copolyester matrix.


  • Open Access

    Elevated-temperature luminescence measurements to improve spatial resolution

    by Mariusz Pluska, Andrzej Czerwinski

    Various branches of applied physics use luminescence based methods to investigate light-emitting specimens with high spatial resolution. A key problem is that luminescence signals lack all the advantages of high locality (i.e. of high spatial resolution) when structures with strong built-in electric field are measured. Such fields exist intentionally in most photonic structures, and occur unintentionally in many other materials. In this case, as a result of beam-induced current generation and its outflow, information that indicates irregularities, nonuniformities and inhomogeneities, such as defects, is lost. We show that to avoid nonlocality and enable truly local luminescence measurements, an elevated measurement temperature as high as 350 K (or even higher) is, perhaps surprisingly, advantageous. This is in contrast to a widely used approach, where cryogenic temperatures, or at least room temperature, are recommended. The elevated temperature of a specimen, together with the current outflow being limited by focused ion beam (FIB) milling, is shown to improve the spatial resolution of luminescence measurements greatly. All conclusions drawn using the example of cathodoluminescence are useful for other luminescence techniques.

  • Detrimental nonlocality in luminescence measurements

    by Mariusz Pluska, Andrzej Czerwinski

    Luminescence studies are used to investigate the local properties of various light-emitting materials. A critical issue of these studies is presented that the signals often lack all advantages of luminescence-studies of high locality, and may originate from an extended spatial region of even a few millimeters in size or the whole sample, i.e., places other than intended for investigation. This is a key problem for research and development in photonics. Due to this nonlocality, information indicating defects, irregularities, nonuniformities and inhomogeneities is lost. The issue refers to typical structures with a strong built-in electric field. Such fields exist intentionally in most photonic structures and occur unintentionally in many other materials investigated by applied physics. We reveal [using test samples prepared with focused ion beam (FIB) on an AlGaAs/GaAs laser heterostructure with an InGaAs quantum well (QW)] that nonlocality increases at low temperatures. This is contrary to the widely expected outcome, as low-temperature luminescence measurements are usually assumed to be free from disturbances. We explain many effects observed due to nonlocality in luminescence studies and prove that separation of the investigated area by focused ion beam milling is a practical solution enabling truly local luminescence measurements. All conclusions drawn using the example of cathodoluminescence are useful for other luminescence techniques.


  • Dependence of cathodoluminescence on layer resistance applied for measurement of thin-layer sheet resistance

    by A. Czerwinski, M. Pluska, J. Ratajczak, A. Szerling, J. Kątcki

    The dependence of spatially and spectrally resolved cathodoluminescence in a scanning electron microscope on resistances in semiconductor structures, especially on the layer resistance, is reported. This previously unstudied dependence is utilized for thin-layer sheet-resistance measurement. The method is illustrated by an assessment of lateral confinements in semiconductor-laser heterostructures.


  • Separation of image-distortion sources and magnetic-field measurement in scanning electron microscope (SEM)

    by Mariusz Płuska, Andrzej Czerwinski, Jacek Ratajczak, Jerzy Kątcki, Łukasz Oskwarek, Remigiusz Rak


  • Why InGaN laser-diode degradation is accompanied by the improvement of its thermal stability

    by L. Marona, P. Wiśniewski, M. Leszczyński, I. Grzegory, T. Suski, S. Porowski, R. Czernecki, A. Czerwinski, M. Pluska, J. Ratajczak, et al.

    In this paper we present reliability study of violet, InGaN based laser diodes grown on low dislocation density bulk GaN crystals. We observe two main phenomena responsible for degradation in our laser diodes. One of them is the increase of nonradiative recombination in quantum wells which is visible on cathodoluminescence images. The second mechanisms is connected to the increase of leakage current seems to be responsible for the observed evolution of the characteristic temperature of laser diodes.


  • Resistance and sheet resistance measurements using electron beam induced current

    by A. Czerwinski, M. Płuska, J. Ratajczak, A. Szerling, J. Kątcki

    A method for measurement of spatially uniform or nonuniform resistance in layers and strips, based on electron beam induced current (EBIC) technique, is described. High electron beam currents are used so that the overall resistance of the measurement circuit affects the EBIC signal. During the evaluation, the electron beam is scanned along the measured object, whose load resistance varies with the distance. The variation is compensated by an adjustable resistance within an external circuit. The method has been experimentally deployed for sheet resistance determination of buried regions of lateral confinements in semiconductor laser heterostructures manufactured by molecular beam epitaxy.


  • Open Access

    In situelectron beam induced current measurements of the local thickness in semiconductor devices

    by A. Czerwinski, M. Płuska, J. Ratajczak, J. Katcki

    A quantitative electron beam induced current method is shown, applicable in situ for electron beam current measurement on a semiconductor sample without the need for a Faraday cup. As a validation technique, the measurement of top overlayer thickness in the semiconductor structure was chosen for two reasons. First, the measured thickness is easily verified using the same electron microscope in the secondary electron mode by measuring the layer thickness at the layer edges. Second, the measurement of a layer thickness and its local variations constitute an important issue in semiconductor processing and characterization. The proposed method is used in the planar view of the sample, and also for locations far from the layer edges. Quasi-three-dimensional maps of the thickness spatial distribution are presented.